| 1 | Earth work in excavation of ordinary rock by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, complete all as specified and directed.Note:- Removal of surplus soil upto 50 mtrs is already included in the above item and distance beyond 50 m shall be measured and paid separately. |
| 2 | All as per Item No.01 above,but exceeding 1.50 m in depth and n.exc 3 m depth complete all as specified and directed. |
| 3 | All as per Item No.01 above,but exceeding 3 m in depth and n.exc 4.50 m depth complete all as specified and directed. |
| 4 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth for laying of foundations,drain pipes,manholes,etc and getting out in hard/dense soil complete all as specified and directed. |
| 5 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. |
| 6 | Removing excavated materials in soil to a distance n.exc 50 m and depositing where directed at a level n.exc 1.50 m above the starting point complete all as specified and directed. |
| 7 | Removing excavated materials in soil to a distance exc 50 m and n.exc 250 m depositing where directed at a level n.exc 1.50 m above the starting point complete all as specified and directed. |
| 8 | M & L PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in foundations filling and mass concrete complete all as specified and directed. |
| 9 | M & L PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in surface channels and drains complete all as specified and directed. |
| 10 | M&L Precast cement concrete block masonry with solid blocks exceeding 10cm in width by using precast cement concrete (1:3:6) type C1 (using 20 mm graded stone aggregate) and set in CM (1:6) complete all as specified and directed. |
| 11 | M&L PCC (1:2:4) type B0 (using 12.50mm graded stone aggregate) as in roof kerbs,or mud stops and the like including weathering, slightly rounded or chamfered angles and throating as directed chamfered complete all as specified and directed. |
| 12 | M&L Providing PCC (1:2:4) type B0 (using 12.50 mm graded stone aggregate) as in sub base filling,mass concrete complete all as specified and directed. |
| 13 | Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping),complete all as specified and directed. |
| 14 | Use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, opening in concrete walls, floors and roofs exc. 10 cm but n. exc. 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar works for rough finished surfaces of concrete complete all as specified and directed. |
| 15 | M&L Providing RCC M-30 (Design Mix) (using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelve and like complete all as specified and directed. |
| 16 | M&L Providing RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) as in in lintels/bands etc upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed. |
| 17 | M&L Providing Pre-cast RCC M-30 (Design mix) (using 20mm graded stone aggregates) as in manholes covers set in CM (1:6) including necessary form work complete all as specified and directed. |
| 18 | M& L Rendering 15 mm thick CM (1:4) on stone masonry surfaces finished even and smooth with using extra cement incl sandwitched with chicken mesh wire netting of galvanised steel wire, 1.40mm dia size of mesh 20 mm complete all as specified and as directed. |
| 19 | M&L Filling coarse sand in trenches laid in layers, complete all as specified and as directed. |
| 20 | M&L Gravel packing incl jute as filter media 4mm to 6mm size around the PVC pipe complete all as specified and as directed. |
| 21 | M&L Filling of gravel in trenches of size 6mm to 10m., complete all as specified and as directed. |
| 22 | M& L Filling of gravel in trenches of size 2mm to 4mm,complete all as specified and as directed. |
| 23 | M&L Preparation of new surfaces of steel, of any description, not otherwise described, over 10 cm in width or girth and applying two coats of black bituminous paint over a coat of red oxide primer complete all as specified and as directed. |
| 24 | M&L RCC pipes of size 300 mm dia class NP3, laid and jointed complete with collars complete all as specified and as directed. |
| 25 | S & F MS Jali for Filtration of water and allow to move along the bore Complete all as specified and directed by Engineer-incharge. |
| 26 | M&L TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips,complete all as specified and directed. |
| 27 | All as per Item No.26 above,but 5mm dia and over upto and including 10mm dia as in stirrups , spacers and binders etc., |
| 28 | M&L Rendering 15mm thick in CM (1:4) on brick or concrete or block masonry with finishing the surface even and smooth without using extra cement complete all as specified and directed. Please Enable Macros to View BoQ information |