Tender For Repair/ Maintenance Of External Water Supply, Distribution Lines And Certain Connected Works At Ticca And 2T Det Gemini Area Under Age(I) Dalhousie
Tender Overview
Project Description
Tender for Repair/ Maintenance Of External Water Supply, Distribution Lines And Certain Connected Works At Ticca And 2T Det Gemini Area Under Age(I) Dalhousie
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 06-Jul-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 13-Jul-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | M&L for draining out water from semi undergroung water storage tank of capacity 41000 Gallon scraping out bleachin residual, sediments, sand, fungues scaling etc from inside, bottom and wall of water storage tank with the help of wire brush, steel Patti broom and jute bags and taking out same from the water storage tank and throwing at a distance not less than 25 mtr away from the water storage tank, cleaning inside the water storage tank and then washing and flushing out with fresh water till the entire satisfaction of Engr-in-Charge and writing the date of cleaning on water tank wall with black/white enameld paint after cleaning of external wall surface of the tank with wire brush and remove all busses and algae neatly and painting of GI sheet of the top of the tank with green colour 2 coat of enameled paint all as specified and directed by Engineer-in-Charge (At Ticca Area - 02 Nos) |
| 2 | All as per above srl Item No. 1 here in before but 600000 Galon Capacity complete all as directed by Engineer-in-Charge. (At Ticca Area - 01 Nos ) |
| 3 | All as per above srl Item No. 1 here in before but 20000 Galon Capacity complete all as directed by Engineer-in-Charge. (At Ticca Area - 01 Nos ) |
| 4 | All as per above srl Item No. 1 here in before but 10000 Galon Capacity complete all as directed by Engineer-in-Charge. (At Ticca Area - 02 Nos ) |
| 5 | All as per above srl Item No. 1 here in before but 10000 Ltr Capacity PVC tank including changing of broken tank cover with locking arrangement complete all as specified and directed by Engineer-in-Charge. (At Ticca Area - 03 Nos) |
| 6 | Excavation in trenches for not exc 1.5 mtr wide and not exc 1.5 mtr depth and getting out in Hard/dense soil for laying of GI pipe complete all as specified and directed. |
| 7 | Returning filling in including spreading levelling watering and well ramming in layers n.exc 25cm complete all as specified & directed. |
| 8 | Removing excavated materials n.exc 50m and depositing where directed at a level n.exc 1.5m above the Starting point. |
| 9 | M&L for Taking up or down galvanized steel tubing with complete fitting for refixing or removal of worksite complete all as specified and directed by Engineer-in-charge. |
| 10 | (a) 15mm bore |
| 11 | (b) 20mm bore |
| 12 | (c) 25mm bore |
| 13 | (d) 40mm bore |
| 14 | (e) 50mm bore |
| 15 | (f) 80mm bore |
| 16 | (g) 100mm bore |
| 17 | Supply and laying in trench/fixed on wall/floors galvanized steel water tubing medium grade ISI marked of the following sizes incl all fittings such as bends elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps and pigs, unions etc. complete all as directed.Note :- Necessary excavation and earth work shall be measured and paid separately |
| 18 | (a) 15mm bore |
| 19 | (b) 20mm bore |
| 20 | (c) 25mm bore |
| 21 | (d) 40mm bore |
| 22 | (e) 50mm bore |
| 23 | (f) 80mm bore |
| 24 | (g) 100mm bore |
| 25 | S&F gunmetal globe or gate valve with iron wheel head screwed bolt ends for iron pipe of the following sizes complete incl taking down old gate valves all as specified and directed by Engineer-in-charge. |
| 26 | (a) 15mm bore |
| 27 | (b) 20mm bore |
| 28 | (c) 25mm bore |
| 29 | (d) 40mm bore |
| 30 | (e) 50mm bore |
| 31 | Taking out U/S CI sluice valve for the following sizes, supply and fixing new CI sluice valves Class PN1.6 confirming to ISI with flaged ends both ends with gun metal/steel spindle, round wheel incl jointing materials complete all as directed. |
| 32 | (a) 80mm bore |
| 33 | (b) 100mm bore |
| 34 | Removing the existing sluice valve of the following sizes and taking out the worn out gate and spindle refixing back the gate supply and fixing the new spindle made out of stainless steel rod of suitable size to fix the existing gate inc check nut regrinding of the gate fixing of nuts bolts gaskets etc complete all as specified: |
| 35 | (a) 80mm bore |
| 36 | (b) 100mm bore |
| 37 | Supply and fixing Ball brass valves high pressure with polythene flote and flynut complete secewed for iron pipe or brass feerrule 20mm dia including taking down u/S valve complete all as specified and directed by Engineer-in-Charge. |
| 38 | M&L for Cutting the existing CI/GI pipe 80/100 mm bore or screwing existing CI/GI pipe for addn or altn as required on site including GI fiitings complete all as directed.Note: Necessary earth work shall be measured and paid separately. |
| 39 | Repairs to Mechanical water level indicator including replacing steel wire rope, float valve and welding of broken stand, scrapping of existing paint and painting with enamel paint over a coat of redoxide and marking of level for sump of any capacity complete all as specified and directed by Engineer-in-Charge. |
| 40 | Supply and laying in trench/fixed on wall/floors 3 layer PP-R polypropylene Random Concealed pipeUV Stailized and antimicrobial thermotech PN-1.6 of size 16mm bore ISI marked of the following sizes incl all fittings such as bends elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps and pigs, unions etc. complete including taking down old pipe all as directed. Note :- Necessary excavation and earth work shall be measured and paid separately |
| 41 | (a) 20 mm bore |
| 42 | (b) 25 mm bore |
| 43 | (c) 32mm bore |
| 44 | (d) 40 mm bore |
| 45 | (e) 50 mm bore |
| 46 | S&F gunmetal PPR-C gate valve with MS head screwed fixed with PPR pipe of the following sizes complete incl taking down old gate valves all as specified and directed by Engineer-in-charge. |
| 47 | (a) 20mm bore |
| 48 | (b) 25mm bore |
| 49 | (c) 32 mm bore |
| 50 | (d) 40mm bore |
| 51 | (e) 50mm bore |
| 52 | M&L construction of brick masonary valve pit built in cement mortar 1:6 including all excavation and earth work in any type of soil and disposal of surpluse soil to a distance not exc. 50 mtr all as directed by Engineer-in-charge including 10mm thick plastering internally in CM 1:4 and flush pointing in same mortar to brick work externally as work proceeds and cement concrete in foundation PCC (1:4:8) type D-2 15 cm thick & PCC 1:3:6 type C-1 coping, including 75 mm thick & hard core of gauge and exc. 63mm using broken stone /bolder, MS sheet cover 3.15 mm thick MS angle iron frame, handle locking arrangement and painting to steel surfaces including dismantling of old valve pit complete all as specified and directed by Engineer-in-Charge. incl necessary excavation earth work of the following sizes :- |
| 53 | (a) 900 mm x 900mm x 900mm |
| 54 | (b) 1200mmx1200mmx1200mm |
| 55 | Supply only chlorine chemical test kit in replacement of old u/s kit for testing of water complete all as specified and directed by Engineer-in-Charge. |
| 56 | M&L 75mm thick PCC type B-2 (1:2:4) using 40mm graded stone aggregate as in sub floor, sub, floors and pavings etc complete all as sprecified and directed |
| 57 | M&L for chequred cement concrete tiles 20cm x20cmx25mm thick set, joined and pointed in neat cement slurry in floors with grey cement and pigment including 15 mm thick screed bed in CM 1:6 including taking down old surface complete all as specified and directed |
| 58 | Supply and fix Non return sluice valve of size 80mm dia complete all as specified and directed. |
| 59 | Testing of water sample for Main water supply installation Ticca Area, considering all parameter of drinking water as per IS Specification through authorised Govt laboratory and produced to the Engr-in-charge for records. |
| 60 | Supply and fixing Ductile iron pipe (Conforming to IS 8329) with spigot and socket ends of bore 150 mm special class K-9 suitable for tyton joint including jointing material /joints laid in trenches complete all as specified and directed by Engr-in-charge. |
| 61 | Supply and fixing Ductile Iron fittings for ' DI ' pipe (Conforming to IS 9523) such as Bends ,collars ,Tapers,Tee pieces (single & double branch) any type and angle /radius and straight connecting pieces upto 250 dia includings jointing material/joints complete all as specified and directed by Engr- in charge. |
| 62 | M & L disconnection of DI existing pipe line 100/150/80mm dia with dismentling of thrust block and disconnection of titen joint of DI pipe line and refixing with PCC thrust with complete plaster and refixing again on same place for proper alignment/arrangement of DI Pipe line with complete testing all as specified and directed.Note : Thrust Block PCC will be measured and paid separately. |
| 63 | M&L for construction of Thrust block of size shuld be required as per site made out of PCC 1:2 :4 using 20mm graded stone aggregate grade B-2 for holding of raising mains of CI/GI pipe line complete all as specified and directed. |
| 64 | Supply and fixing LED Street light fitting 35/45watt 230 V, AC, outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant includng thermal management in multiple optic complete with IP 65/66 protection complete, all as specified and directed by Engineer-in-Charge. |
| 65 | Supply and fixing LED Street light fitting 60 watt 230 V, AC, outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant includng thermal management in multiple optic complete with IP 65/66 protection complete, all as specified and directed by Engineer-in-Charge. |
| 66 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor,served with inner sheathing of PVC tape and overall PVC Sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4 mm suspension wire,one twin core 4 sqmm cable complete and all as specified and directed by Engineer-in-charge. |
| 67 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor,served with inner sheathing of PVC tape and overall PVC Sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4 mm suspension wire,one twin core 6 sqmm cable complete and all as specified and directed by Engineer-in-charge. |
| 68 | S&F Rotational moulded polyethelyne water storage tank three layered (cylindrical vertical with closed top hoisted fixed in position all as specified in SSR part-I, capacity of tank 1000 ltr incl inlet and outlet connection 20mm dia and 15mm dia GI pipes medium grade respectively and dismantling water tanks (Capacity of tank exc 500 Ltr but n exc 1000 Ltr) and removing from site,complete all as specified. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 4 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender