| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed PVC conduit(heavy) with modular switch modular plates suitable size modular GI box of specified Category and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.;(a) Group A -- with Cat A Modular Accessories |
| 2 | Wiring for group controlled light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed PVC conduit(heavy) and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 3 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent recessed PVC conduit(heavy) of appropriate size as required.;(a) 2 x 1.5 sq.mm + 1 x 1.5 sq.mm earthwire (20mm Conduit) |
| 4 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent recessed PVC conduit(heavy) of appropriate size as required.;(b) 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earthwire (20mm Conduit) |
| 5 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent recessed PVC conduit(heavy) of appropriate size as required.;(k) 4 x 10 sq.mm + 2 x 10 sq.mm earthwire (32mm Conduit) |
| 6 | Wiring for 5A /15A power plug with 2 x 4 sq.mm FRLS PVC insulated copper conductor single core cable in recessed PVC conduit(heavy) alongwith 1 No 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 7 | Supplying and fixing 3 pin 5/6 A modular socket outlet and 5/ 6 A modular switch on board the modular surface/recessed PVC/GI modular box by suitably increasing its modular capacity modular plate and cover including connection painting etc. as required.;(a) Cat A |
| 8 | Supplying and fixing suitable size modular PVC box with modular plate and cover in front on surface or in recess including providing and fixing 4 nos 3 pin 5/6 A modular socket outlet and 4 nos 5/ 6 A modular switch connection painting etc. as required. The scope of work includes alternate arrangement if required as per site conditions to provide switches and sockets seperately above and below the table respectively. (For workstations);(a) Cat A |
| 9 | Supplying and fixing suitable size modular PVC box with modular plate and cover in front on surface or in recess including providing and fixing 1 no 6 pin 15/16 A modular socket outlet and 1 nos 15/ 16 A modular switch connection painting etc. as required. ( For workstations);(a) Cat A |
| 10 | Supplying and fixing modular blanking plate on the existing modular plate switch box excluding modular plate etc. as required;(a) Cat A |
| 11 | Supplying and fixing suitable size modular GI box with modular plate and cover in front on surface or in recess including providing and fixing required number of modular switches connection painting etc. as required. ( For group controlled points);(a) Cat A |
| 12 | Supplying and fixing following size modular PVC box alongwith modular base and cover plate for modulator switches in recess etc. as required;(a) 1 or 2 Module Cat A |
| 13 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required;(a) Cat A |
| 14 | Installationearthing testing and commissioning of ceiling fan including wiring the down rod of standard length ( upto 30 cm) with 1.5 sq .mm FRFRLS PVC insulated copper conductor single core cable etc. as required. |
| 15 | Supply and erecting of 48 inch (1200mm sweep) ceiling fan double ball bearing type complete with all accessories.;(a) Cat A |
| 16 | (c) For 6 inches rafter size |
| 17 | Supplying and fixing extra down rod of 20 cm length GI pipe 15 cm dia heavy gauge including painting etc as required |
| 18 | Supplying and fixing following way TPN sheet steel double door Verticle type MCB distribution board 415 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required ( but without MCB/RCCB/Isolator)interconnection between incomer MCB and busbars of following ways (but without MCBs as required);(a) 4 way (8+12) double door Vertical type Cat A |
| 19 | Supplying and fixing following way SPN sheet steel MCB distribution board Consumer Unit 240 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar hinged front acrylic cover for the MCB knobs detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required (but without MCB/RCCB/Isolator);(a) 2 + 4 way Cat A |
| 20 | Supplying and fixing 63 A C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.;(d) TP Cat A |
| 21 | Supplying and fixing following rating four pole 415 V isolator in the existing MCB DB complete with connections testing and commissioning etc as required;(b) 63 A Cat A |
| 22 | Supplying and fixing 6 A to 32 A C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.;(a) SP Cat A |
| 23 | Supplying and fixing 40 A C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.;(c) DP Cat A |
| 24 | Earthing with GI earth pipe 2 mts long 40 mm dia medium class with ISI mark of approved brands including accessories and providing masonry enclosure with CI/RCC cover having locking /Lifting arrangement and watering pipe etc. (but without charcoal or coke and salt) as required as per the Earthing Drawing provided by the Engineer-Incharge.The scope of work includes the following: a) Excavation of pit of size not less than 1.0x1.0x 2.0 mtrs(min) and disposal of excavated soil. b) Class B GI pipe 40mm diameter as per specifications. c) Charcoal/salt as per specs ( paid seperately). d) Refilling the pit of size not less than 1.0x1.0x 2.0 mtrs(min) with soft black soil of minimum resistivity i/c transportation. e)Masonary chamber with proper foundation cover plate and locking arrangement. f) Testing of earth value with earth megger and certifications of its value. Aluminium tag with embossed earthing value to be attached to the pipe. g)watering arrangement(plumbing will be paid seperately).;(b) In rocky strata |
| 25 | Extra for using salt and charcoal for pipe earth electrode as required( 65 Kgs of Charcoal and 5 Kgs of Salt). |
| 26 | Providing and fixing 4 mm dia copper wire on surface or in recess for loop arthing along with existing surface/ recessed conduit/ submain wiring/ cable as required |
| 27 | Supply of 3 core unarmoured PVC/XLPE insulated PVC sheathed copper conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) IS:7098(Part I) with latest amendments of following size.;3 Core 2.5 sq.mm |
| 28 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Inchargesand cushioning with screened sand bed of 20mm thick protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable) and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required.;(b) In rocky strata |
| 29 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm on surface etc. complete as required |
| 30 | Supply Installation Testing & Commissioning of of Round Ceilling Mounted Surface LED light fixture as required of make havells model no.ZIVASURRDDLR24WLED857S (210 mm dia 24W or above) or Equivalent in similar pattern in recognised ISO certified brands only & to be approved by the Engineer in charge. |
| 31 | S.I.T.C. of 60W LED 5700k. or above, Streetlight luminaire with efficient high performance power LEDs, integral driver in pressure die cast metallic housing with heat resistance toughened glass, having IP-66 protection, better optics for uniform light distribution, suitable for mounting on a pole arm brackets of outer dia as required, along with terminals and other accessories etc, including connections complete as required of makes Retek, or equivalent in Bajaj, Jaguar, Sanctity, Philips, Crompton or any other ISO Certified brand etc.as per directions of the engineer in charge. Transportation from factory to site is inclusive. |
| 32 | Supplying and fixing DK thermoplastic Cable Junction Boxes130 x 130 x 77mm IP 66/69 weather proof for outdoor installation (with knockouts for cable entry) including connections etc & inbuilt 4 way stud type connectors of make Hensel cat no. DK 0604 G / spelberg and fixing of 32 mm dia Gi pipe including, clamps nut bolts, cement, sand, excavation for mounting etc. as required. |
| 33 | SITC of 4Mtr length octagonal hot dip galvanised pole, with top dia of 70mm, having 3mm sheet section thickness alongwith base plate of size 220x 220x12mm (LxBxT), including J-type M16 x450 MM foundation bolts set along with required tamplate, a Smart pack junction box shall be provided with 1no 6A MCB on DIN rail and 4pole red strip connector /terminal block (60Arating) suitably enclosed with watertight door with locking arrangement, mounted flushed inside base compartment, having suitable entry for drawing two or more cables upto 16sqmm. The poles shall be of make: Consul, RR ipat, or equvivalent in Bajaj, Jaquar, Suncity, phillips, crompton or any other ISO Certified brand etc. as per directions of the Engineer incharge. Transporation from factory to site is inclusive. |
| 34 | Supply and Fixing of Single arm bracket of 1m Standard length, of appropriate dia suitable for 4mtr or 6Mtr hieght poles for top section (70mm) of make: Consul, RR ipat, or equvivalent in Bajaj, Jaquar, Suncity, phillips, crompton or any other ISO Certified brand etc. as per directions of the Engineer incharge. Transporation from factory to site is inclusive. |
| 35 | Earthwork in excavation by mechanical means (hydraulic excavator)/manual means in foundation pipeline trenches drain (not exceeding 1.5 m in width or 10 sq.m. on plan) including dressing of sides and ramming of bottoms lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m.;All kinds of soil;All types of Ordinary rock including all types of laterite rock blasting prohibited |
| 36 | Providing and laying cement concrete 1:4:8 (1 cement: 4 coarse sand: 8 graded granitic a basaltic stone aggregate 40 mm nominal size) excluding cost of centering shuttering and finishing in;All works upto plinth level |
| 37 | Providing TMT steel reinforcement bars of (SAIL TATA. VIZAG JSW Steel Ltd.) ) (Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending binding & placing in position in all the floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member. |
| 38 | Supplying and fixing of following sizes of rigid PVC conduit alongwith accessories in surface(medium)/recess(heavy) including cutting the wall and making good the same in case of recessed conduit as required.;(b) 25 mm |
| 39 | Supplying and fixing of following sizes of PVC casing caping alongwith accessories on surface as required.;(b)25mm casing capping |
| 40 | Dismantling, removal & stacking of old wiring including removal of wires , old fans & lighting fixtures cable ,DB's, down rods, Switch Boards etc. and handing over to the Sub health centre Please Enable Macros to View BoQ information |