| 1 | SH-I: (RMO EI , Fans , Pumpsets , Street Light ) Providing day to day maintenance of EI & fans comprising of light point, fan point call bell point, power point ,submain wiring ,fans, fittings, DBs and Panel i/c all electrical works , security lights, pole light , pumpsets & DG sets etc on all working days excluding Sunday and Holidays as per terms and condition attached and timing as per direction of Engineer -in- charge at labour court nimri colony (B) Staff required for Old Age Home:- a) Wireman Cum Lift Operator :- 02 Nos. (10:00 AM to 6:00 PM, 10:00 PM to 6:00 Am) |
| 2 | SH-II (Material) Supplying and fixing of following electrical accessories for day maintenance in the existing electrical installation etc. as reqd ( Labour for fixing is already include in above item) (Material consumption statement will be maintained by agency in Task Register). a) SP 5/6 A, one way modular switch, ISI marked |
| 3 | b) SP 15/16 A, one way modular switch, ISI marked |
| 4 | c) 3 pin 5/6 A modular socket outlet, ISI marked |
| 5 | d) 6 pin 15/16 A modular socket outlet, ISI marked |
| 6 | e) 15 Amp 3 Pin plug Top (ISI Marked) |
| 7 | f) 25A Modular SPMCB 'C' Curve |
| 8 | g) 6A, to 32 A, ratings, SP MCB, \\"C\\" Curve, 10 KA Breaking Capacity |
| 9 | h) 6A, to 32 A, ratings, DP MCB, \\"C\\" Curve, 10 KA Breaking Capacity |
| 10 | i) Call bell/ buzzer, single phase |
| 11 | j) Modular bell push, ISI marked |
| 12 | k) 63 Amp DPMCB 10 kA breaking capacity |
| 13 | l) 63 Amp TPN MCB 10 kA breaking capacity |
| 14 | m) 400 mm sweep wall fan |
| 15 | n) 300 mm 1400 RPM heavy duty exhaust fan ISI Mark |
| 16 | o) Supplying & replacement of 2.5 MFD capacitor |
| 17 | p) two module stepped fan regulator |
| 18 | q) 125 Amp, 16 KA, TPMCCB |
| 19 | r) 1.5 sq. mm ISI marked, FRLS/HFFR PVC insulated, single core copper conductor cable |
| 20 | s) 4.0 sq. mm ISI marked, FRLS/HFFR PVC insulated, single core copper conductor cable |
| 21 | t) LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt ) of following body materials. Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector i) 30 watt |
| 22 | u) LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt) of following body materials. Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) i) 40 watt |
| 23 | v) LED Batten light (System lumen efficacy ≥105 <120 lm/Watt) of following body materials. Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) i) 36 watt |
| 24 | w) LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy 105 <120 lm/Watt) of following body materials. i) 200 watt |
| 25 | x) ceiling fan with Brush Less Direct Current (BLDC) Motor, etc. complete as req i) 1200mm, BEE 5 star rating, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 26 | SH-III (Minor EI & Pumpset Repair Work) Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. a) Group C |
| 27 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. a) Group C |
| 28 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. a) 3 x 1.5 sq. mm |
| 29 | b) 6 x 1.5 sq. mm |
| 30 | c) 3 x 4 sq. mm |
| 31 | d) 6 x 4 sq. mm |
| 32 | Wiring for light/ power plug with 2X4 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required |
| 33 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) 16 way, Double door |
| 34 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. a) 25 mm |
| 35 | New Generation IP65 LED, 25 Watt post top family, energy saving, enviromental friendly, long life aesthetically designed with symmetrical light distribution spun aluminium landscape luminaire with high power LEDs as light source. Opal Cover offers soothing uniform ilumination for different applications etc. as required at site. |
| 36 | SH-IV (Fire Fighting) Repair & Minor Maintenance Work Dismantling existing fire extinquishers and refilling of following capacity and type from installed position removing old gas/other extinguishing material from from cylinder hydraulic pressure testing taking to workshop,refilling of gas/catridge/other extinguishing material,pasting of stickers,bring back to site and reinstalltion etc as required. a) ABC powder type fire extingusher 6 kg capacity |
| 37 | b) Co2 gas type fire extinguisher 4.5 kg capacity |
| 38 | Rewinding of following size Submersible/Mono submersible/monoblock pumpset i/c dismantling of pumpset from site, cartage from site to work shop and return back, cutting the burnt winding wire (credit for old winding wire) & rewinding the same with PVC insulated copper winding wire etc. as reqd. a) 5 Hp |
| 39 | S/I/T/C of Starter Control panel for 3 phase motor upto 7.5 HP having DOL starter of relay range 9 to 14 Amp. on the wall mounting comprising of contactor, relay, single phase preventor, auto-manual On/Off voltage selector switch, voltmeter, ammeter, push buttons etc. as reqd. |
| 40 | Lowering of upto 3/5/7.5/10/20 HP Mono Submersible/Sewage/ Submersible P/set along with G.I. pipe in existing well/underground tank with the help of chain pulley and tripod etc. as reqd. |
| 41 | Taking out of upto 3/5/7.5/10/20 HP Mono Submersible/Sewage/ Submersible P/set along with G.I. pipe in existing well/underground tank with the help of chain pulley block and tripod complete as reqd. |
| 42 | Repairing of existing burnout Sub panel Dismantling/ Disconnection of All Cable Connection from bus bar MCCB, removing all melted/ Damaged alluminium bus bar solid connecton link to switchgears cleaning of all terminals of MCCB/MCB Bus bar with thinner CTC removing carbon dust dirt by sand paper including replacement of all damaged aluminium bus bar solid connection link, suitable for 250 & 100AMP MCCB with Fabricaton, Drilling, Replacing deffective nut, Bolt, washer i/c interconnection with 10 Sq.mm FRLS copper wire for MCB and reconnections all the cable to bus bar/MCCB after repairing the Sub panel, Providing missing front cover i/c making good the same for suitable for 415 Volt 50Hz AC supply complete with testing Etc as reqd. |
| 43 | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). a) 1.5 TR with 5 Star BEE Rating |
| 44 | Supplying, Laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor armoured power cable of 1.1 kV grade of following size on wall surface as required. (a) 3 X 16 sq. mm Alu. Cable. Please Enable Macros to View BoQ information |