| 1 | Boring/drilling bore well of required dia for casing/ strainer pipe, bysuitable method prescribed in IS: 2800 (part I), including collectingsamples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools,plants & machineries required for the job, all complete as per directionof Engineer-in-charge, upto 90 metre depth below ground level. All types of soil 350 mm dia. |
| 2 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. All types of soil 350 mm dia |
| 3 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in charge.200 mm nominal size dia metre. |
| 4 | Supplying, assembling, lowering and fixing in vertical position in borewell unplasticized PVC medium well screen (RMS) pipes with ribs,conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.200 mm nominal size dia metre. |
| 5 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. |
| 6 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia. |
| 7 | Providing and fixing M.S. clamp of required dia to the top of casing/ousing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete 100 mm clamp each. |
| 8 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia each. |
| 9 | Providing, assembeling and lowering to proper levels 50 mm G.I. pipe for tube well including fittings inside the borewell. |
| 10 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc.,all as per requirement and direction of Engineer-in-charge. |
| 11 | Providing and Assembeling 5 HP 3 phase motor of KSB, Crompton, Kriloskar, or equivelent of 10 stage or as required |
| 12 | Providing and Assembeling 3 HP 3 phase motor of KSB, Crompton, Kriloskar, or equivelent of 10 stage or as required |
| 13 | Providing and Assembeling 10 HP 3 phase motor of KSB, Crompton, Kriloskar, or equivelent of 10 stage or as required |
| 14 | Providing and supplying of L&T or equivalent for 10 HP 3 phase pump starter |
| 15 | Providing and supplying of L&T or equivalent for 5 HP 3 phase pump starter |
| 16 | Providing and supplying of L&T or equivalent for 3 HP 3 phase pump starter |
| 17 | Providing and fixing of 3 core 4 sq. mm (each core) flat submersible copper cable (ISI/ Branded). |
| 18 | Providing and fixing of supporting wire of 10 mm dia. (ISI/ Branded). |
| 19 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40 mm nominal dia Pipes |
| 20 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 32 mm nominal dia Pipes |
| 21 | CPVC stop cock 32 mm |
| 22 | CPVC stop cock 40 mm |
| 23 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 50 to 80 mm nominal bore. |
| 24 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 25 | Installatation of 3 corex2.5 sqmm copper submersible pump cable Please Enable Macros to View BoQ information |