| 1 | Supplying of XLPE insulated PVC sheathed aluminium conductor armoured cable working voltage 1100 volts grade as per IS 7098 |
| 2 | 16 sqmm (4.0 core) |
| 3 | Laying of one no. PVC sheated/XLPE power cable of 1.1kv grade of follwing size on wall surface as required |
| 4 | upto 35 sq. mm |
| 5 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. |
| 6 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 7 | Supplying and making indoor termination wirth brasscompression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 8 | 4 X 16 sq. mm (28mm) |
| 9 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. |
| 10 | Above 8.0 Meter and upto 10.0 Meter |
| 11 | Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required. |
| 12 | 32 mm dia |
| 13 | Supplying of 08 mtr high hot galvanised octagonal pole, continously tapered (bolt fixing type) in single section made out of 3mm thick sheet suitable for bracket having top dia 70-75mm and bottom dia 130-150 mm, base plate size 220X220X12 to 240X240X16 mm with door and locking arrangement complete with minimum 1 mtr long MS/GI street light bracket, bakelite sheet,neutral link, suitable MCB or any other electrical accessory,suitable foundation bolts of diameter 16 to 20 mm,700mm apprx length, \\"J\\" type,4 pcs set, LED lights fitting including all connections,interconnections,earthing , testing and commissioning. Make : Bajaj/Philips/Surya/BPP |
| 14 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and 85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time(LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not morethan the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junctiontemperature shall not rise above 90°C) |
| 15 | 250 watt |
| 16 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 17 | 40A Please Enable Macros to View BoQ information |