Tender For Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For C, Khurd-Haryana
TDR : 55924338
Tender Notice
BOQ
Expired
Khurd
Haryana
Tender For Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For C
COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3 core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2 Outer Sheathed, /1100 V grade as per IS 7098 (Part 1) 1988 with up to date amendments along with all accessories like thimble lugs etc for motors as per entire satisfaction of Engineer-in-charge complete in all respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / RR Cables / CAPP / Gloster / Universal / Fort Gloster Industries Ltd./ Asian Cables Corporation Ltd 16 mm2 3core
2
Raw Water Pump set : Supply erection, Testing and commissioning of Horizontal Motor Pumping Set for Raw Water having head as per indicating requirement of discharge in LPM and power capacity in BHP as per IS marked complete in all respect 500 LPM x 12.00 Mtr Head = 5.00 BHP..
3
PANEL BOARDS FOR MOTOR: - Supply Erection, Testing and Commissioning of wall mounted electrical LT Panel board, fabricated from SWG CRCA sheet duly stoten with suitable angle iron frame work and completely powder coated of suitable size deep having following item for 1 Non clog submercible pumping) START DELTA STARTER :- 1. Main MCCB (ABB/LandT/SCHNEIDER - 01nos 2. Controlling MCB - 01nos 3.THERMAL OVER LOAD RELAY (ABB/LandT/SCHNEIDER) - 01 nos 4. AUXILARY CONTACTOR (ABB/LandT/SCHNEIDER) - 03 nos 5. START/STOP PUSH BUTTON (SCHNEIDER/SALZAR/SEIMENS) 6. EMERGENCY SWITCH (SCHNEIDER/SALZAR/SEIMENS) - 01 nos 7. DIGITAL VAF METER (SECURE/SELEC/TECHNO/ABB) - 01 nos 8.CT RATIO - 100/5 (AE/KAPPA/LandT) - 01 nos 9. CAPACITOR BANK AS PER LOAD REQUIREMENT 10. CHANGE OVER SWITCH AS PER LOAD (SCHNEIDER/SALZAR/SEIMENS) - 01 nos 11. SELECTOR SWITCH (SECURE/SELEC/TECHNO/ABB) - 01 nos 12. SINGLE PHASE PREVENTER (SECURE/SELEC/TECHNO/ABB) -01 nos 13. ELCB BREAKER (ABB/LandT/SCHNEIDER)500 x 45 Mtr. Head..
4
PANEL BOARDS FOR MOTOR: - Supply Erection, Testing and Commissioning of wall mounted electrical LT Panel board, fabricated from SWG CRCA sheet duly stoten with suitable angle iron frame work and completely powder coated of suitable size deep having following item for 1 Non clog submercible pumping) START DELTA STARTER :- 1. Main MCCB (ABB/LandT/SCHNEIDER - 01nos 2. Controlling MCB - 01nos 3.THERMAL OVER LOAD RELAY (ABB/LandT/SCHNEIDER) - 01 nos 4. AUXILARY CONTACTOR (ABB/LandT/SCHNEIDER) - 03 nos 5. START/STOP PUSH BUTTON (SCHNEIDER/SALZAR/SEIMENS) 6. EMERGENCY SWITCH (SCHNEIDER/SALZAR/SEIMENS) - 01 nos 7. DIGITAL VAF METER (SECURE/SELEC/TECHNO/ABB) - 01 nos 8.CT RATIO - 100/5 (AE/KAPPA/LandT) - 01 nos 9. CAPACITOR BANK AS PER LOAD REQUIREMENT 10. CHANGE OVER SWITCH AS PER LOAD (SCHNEIDER/SALZAR/SEIMENS) - 01 nos 11. SELECTOR SWITCH (SECURE/SELEC/TECHNO/ABB) - 01 nos 12. SINGLE PHASE PREVENTER (SECURE/SELEC/TECHNO/ABB) -01 nos 13. ELCB BREAKER (ABB/LandT/SCHNEIDER) 500 LPM x 12 Mtr Head
5
Operation and Maintenance for complete scope of work mentioned in the DNIT (Disinfection material supplied by PHED) as per schedule-IV for a period of 5 year after 12 month during defect liability period and 03 Months trial run period will be charged to the A/ Mtc. estimate complete in all respect as per Approved NIT.(i) During defect liability period (Operation only) after 3 month trial run period.
6
(ii) During 1st year after defect Liability period.
7
(iii) During 2nd year.
8
(iv) During 3rd year.
9
(v) During 4th year.
10
(vi) During 5th year.
11
Item Description HSR Item
12
H.S.R. Items DNIT Name :AZADNAGAR:- DNIT for Providing Independent Water Works and Distribution System in village Azad Nagar, District. Bhiwani. “Const of 1 No SandS Tank, 1 No Clear Water Tank, 2 No Filter Beds, 1 No High Level Tank, 1 No Pump Chamber, Boundary Wall, CC Path, Suction well for Raw Water and Clear Water, Prov. and erection of Pumping Machinery for RW and CW, Laying of Raw Water rising Main, Laying of Distribution System, providing FHTC in village Azad Nagar and Operation and Maintenance during defect liability period of 12 months after successful completion of 3 Months trial run and thereafter for 5 years complete in all respect and all other works contingent thereto” Please Enable Macros to View BoQ information
We takes all possible care for accurate & authentic tender information, however Users
are requested to refer Original source of Tender Notice / Tender Document published by
Tender Issuing Agency before taking any call regarding this tender.