| 1 | 1.10.1Wiring for light point/ fan point/exhaust fan point/ call bell point with 1.5 FRLS PVC insulated copper conductor single core cable in surface / recessed medium class conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group A |
| 2 | 1.11Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 3 | 1.14.1Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2x1.5 sq.mm + 1x1.5 sq.mm earth wire |
| 4 | 1.17.3Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 X 1.5 sq.mm |
| 5 | 1.17.32Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 5 x 6 sq. mm |
| 6 | 1.21.2Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm |
| 7 | 1.24.2Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 2 way 5/6 amps switch |
| 8 | 2.10.1Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, 'C' curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 9 | 2.10.4Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, 'C' curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole |
| 10 | 2.11Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 11 | 2.13.3Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 100 amps |
| 12 | 2.15.3Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps |
| 13 | 2.2.14Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel. making connections. etc. as required. 125 Amp, 36 KA |
| 14 | 2.2.16Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel. making connections. etc. as required. 250 Amp, 36 KA |
| 15 | 7.9Supplying and making cable route marker with cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. |
| 16 | 9.1.24Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 1/2X 95 sq. mm (45mm) |
| 17 | 9.1.27Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 1/2X 185 sq. mm (57mm) |
| 18 | 9.1.32Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 10 sq. mm (25mm) |
| 19 | 9.1.33Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 16 sq. mm (28mm) |
| 20 | 9.1.34Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 25 sq. mm (28mm) |
| 21 | 9.1.35Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 35 sq. mm (32mm) |
| 22 | 90.11.1.14Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall, making good the damages, colour washing etc. as required 4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/RCCB/RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 23 | 90.12.6.40Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required. 4 core 10 sq mm |
| 24 | 90.12.7.40Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages, colour washing etc. as required. 4 core 10 sq mm with factory made clamp |
| 25 | 90.12.9.2Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench 50/38 mm or nearest size |
| 26 | 90.14.1.1Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubical type MV panel board comprising of the following compononents/devices and complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all swich gear compartments, earthing the doors using 4 sp mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, and indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/flats/slotted angles etc shall not be used for the fabrication of panel assembly. The measurements will be taken the area of the complete sheets used for panel board including partions, folding, shrouding etc. Supply and fabrication of MV panel board using 2.00mm CRCA sheet, powder coated (excluding base frame) |
| 27 | 90.14.10.3Supply, conveyance and fixing the following types &am;: current rated control gears & swithgears conforming to IS 13947 suitable for 440 V, 50Hz, AC supply in the existing panel assembly as required. 16 A-100A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80-100% with thermal magnetic release having adjustable OL |
| 28 | 90.14.11.13MCCB Accessories Supply and fixing rotary handle, External type (including BUC handle with door interlock) in the existing MCCB of rating up to 250 A |
| 29 | 90.14.2.1Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc. |
| 30 | 90.14.3.2Supply and providing heavy duty 'A' section neoprene gasket in the panel board U' section rubber beeding suitable for 1.60/ 2.00 mm sheet |
| 31 | 90.14.5Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board |
| 32 | 90.14.6Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providing heat shrink sleeves etc. as required. |
| 33 | 90.14.7Supply and providing copper earth bus in the panel board |
| 34 | 90.16.1.3Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 3.15 mm copper conductor (10 SWG) |
| 35 | 90.16.1.4Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 4.00 mm copper conductor (8 SWG) |
| 36 | 90.16.5.4Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required. 4.00 mm (8 SWG) |
| 37 | 90.12.5.40Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME/STONE WARE/GI/DWC pipe as required. 4 core 10 sq mm |
| 38 | 90.3.20.3Supply & Installation of light fittings on TW round blockSupply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. diretly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required. 1200 mm 1X20W LED Lamp with box type fixture |
| 39 | OD268977/2025-2026Supply and Installing the following accessories to existing Fabricated MCCB panel Board 1) 1 no Multifunction meter to read V, A, F, PF & kWh 2) 3 Nos RYB Led indication Lamp with MCB including connection etc completed |
| 40 | OD268978/2025-2026Dismantling of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade up to 150 sq. mm. (Dismantling two no 39 end termination also |
| 41 | OD268979/2025-2026Supplying and providing following size of electrical grade rubber mat to site location 1000 mm X 2000 mm X 12 mm. etc completed |
| 42 | OD268980/2025-2026Supply & Laying of DWC pipe in Hard Soil 0.7 m below ground level including excavation. 50/38 mm or nearest size |
| 43 | OD268981/2025-2026Earthing with G.I. earth pipe 2.5 metre long (Hard soil), 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/coke and salt) as required |
| 44 | OD270478/2025-2026Dismantling and re-installing the existing 10 hp motor starter |
| 45 | OD270560/2025-2026Charges for dismantle the damaged Panel board and reconnecting the AUG Cable to new installed panel board. And dismandled panel to be return to electrical store etc including transportation. Please Enable Macros to View BoQ information |