| Sl. No. | Item Description |
| 1 | CIVIL WORK |
| 2 | Excavation of foundation in hard rock (Granite) removed by chiselling including dressing and levelling the bed not exceeding 1.5m in depth and depositing the soil within initial lead of 50m and as per the specification approved by the department. |
| 3 | Earth work in excavation of slushy soil in water upto 0.60m in water by Manually means in over areas excluding dewatering of wherever required, including all lifts, including getting out the excavated soil and disposal of surplus excavated soil as directed within all lead and lift including cost of all labours/ equipments , taxes, sundries and T&P etc all complete as per the direction of Engineer-in-charge. (Measurement be taken in level section only ). |
| 4 | Double under reamed pile foundation with R.C.C. M25 using 12mm size black hard granite (crusher broken)stone chips including cost of boreholes but excluding cost of M.S. rod/Tor steel and labour chrages for cutting, bending and binding of steel -300mm dia 6 mtr Length |
| 5 | Filling with available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering etc. including all lead and lift, cost of labour ,material, conveyance and taxes ,sundries ,T & P, complete as per the directions of Engineer-in-charge. |
| 6 | Filling in foundation, trenches and plinth with river sand, well watered and compacted in layers of with top surface dressed and leveled to proper gradient including cost of all materials, conveyance, all and royalties, loading and unloading, including cost of all labour, sundries ,T & P etc. complete as per directions of the Engineer -in-charge. |
| 7 | Disposal of building rubbish / malba /rock/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved dumping site or as approved /directed by Engineer-in-charge, including all lead and lifts involved, labour, etc. including all taxes as per the direction of Engineer-in-charge. |
| 8 | Providing and laying of Cement Concrete of grade 1: 3 :6 (1 cement : 3 sand : 6 graded stone aggregate of size 25mm to 40 mm hard granite crusher broken metal ), mixing in concrete mixer ,lowering and compacting in proper thickness, watering & curing for the required period. including all cost of labour ,material, conveyance, royalties and , sundries ,T & P etc. complete as per the directions of Engineer-in-charge. |
| 9 | RCC - 25 :- Providing ,Lifting, Hoisting & Laying Reinforced Cement Concrete of M-25 Grade in all type of Concrete works as per IS Specification, including cost of required steel /wood /ply centering and shuttering there after dismantling and removing the debrises away from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, stacking, royalties of all materials, cost of all labours, scaffolding, sundries, T&P required for the work etc. complete in all respect but excluding cost of Reinforcement and Binding wires etc. |
| 10 | Footing/Raft |
| 11 | Column |
| 12 | Rcc Wall |
| 13 | Plinth Beam |
| 14 | GROUND FLOOR |
| 15 | Roof Beam |
| 16 | Roof Slab |
| 17 | Roof Slab slope roof |
| 18 | Lintel & Sill |
| 19 | Staircase |
| 20 | RCC Wall |
| 21 | FIRST FLOOR |
| 22 | Column |
| 23 | Roof Beam |
| 24 | Roof Slab |
| 25 | Lintel |
| 26 | Supplying Cutting, straightening coiled or bent up M.S. Rod or tor steel of primary steel producers such as SAIL / Tiscon / RINL / JINDAL STEEL / SHYAM STEEL/ Rungta Steel/ Reliable Sponge/ Scan Steel/ SMC Power Generation/Shyam Metalics & Energy (grade Fe-500D) etc. including bending, binding, welding and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of Engineer-in-charge. |
| 27 | Flyash Brick Masonry in cement mortar of mix (1:6) using Flyash bricks of size 25 c.m x 12 c.m x 8 c.m having crushing strength not less than 75 kg per square c.m. with cement and screened & washed sharp sand for mortar after immersing the Flyash bricks for 6 (Six) hours in water before use in works such type of works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance, stacking, loading, unloading, royalties and of all materials,cost of all labour,scaffolding, sundries and T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge. |
| 28 | Foundation &Plinth |
| 29 | In Superstructure |
| 30 | First Floor |
| 31 | Flyash Brick Masonry for 125 mm width brick masonry wall in cement mortar of mix (1:4) using Flyash bricks of size 25 c.m x 12 c.m x 8 c.m having crushing strength not less than 75 kg per square c.m with provision of 2 ( Two nos ) of 8 m.m dia M.S. Round Reinforcement Bars at each 4th layers) with cement and screened & washed sharp river sand for mortar after immersing the bricks for 6 (Six) hours in water before use in works in superstructure and similar such type of works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance, loading, unloading, stacking, royalties and of all materials ,cost of all labour, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge. |
| 32 | Ground Floor |
| 33 | First Floor |
| 34 | 12MM THICK CEMENT PLASTER (1:6) :- Providing 12mm thick cement plaster to the surface of brick masonry wall with cement mortar (1:6) with mixing of water proofing compound etc. including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats only to proper plumbs and level and making grooves and beads to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, all and royalties, all labour, scaffolding, watering and curing, sundries and T&P etc all complete as per direction of the Engineer -in-charge. |
| 35 | GROUND FLOOR |
| 36 | FIRST FLOOR |
| 37 | 16MM THICK CEMENT PLASTER (1:6) :- Providing 16mm thick cement plaster to the surface of brick masonry wall with cement mortar (1:6) with mixing of water proofing compound etc. including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats only to proper plumbs and level and making grooves and beads to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, all taxes and royalties, all labour, scaffolding, watering and curing, sundries and T&P etc all complete as per direction of the Engineer -in-charge. |
| 38 | GROUND FLOOR |
| 39 | FIRST FLOOR |
| 40 | 12MM THICK CEMENT PLASTER (1:4) :- Providing 12mm thick cement plaster in cement mortar (1:4) with mixing of water proofing compound to the surface of half brick masonry wall including racking out joints, scraping and cleaning the surface and finisjing the plaster surface smooth using wooden floats ,bars, etc only to proper plumbs and level making grooves, beads and drip courses to give required ornamental finish as per the drawings including cost of all materials, conveyance, loading and unloading ,royalties, cost of all labours ,materials, scaffolding ,watering & curing, sundries, T&P etc. complete as per the direction of Engineer-in-charge . |
| 41 | GROUND FLOOR |
| 42 | FIRST FLOOR |
| 43 | 6MM THICK CEMENT PLASTER (1:4) :- Providing 6mm thick cement plaster with cement mortar of (1:4) with mixing of water proofing compound to RCC surface of roof slabs ceilings , stairs, landings, chajja, shelves, columns, beams and lofts etc. including roughening, scraping and cleaning and finishing the plastered surface smooth using wooden floats only to proper plumbs and level, making grooves and beads to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, all and royalties, all labour, scaffolding, watering and curing , sundries and T&P etc all complete as per direction of the Engineer -in-charge. |
| 44 | GROUND FLOOR |
| 45 | FIRST FLOOR |
| 46 | TERRACE GRADING CONCRETE :- Providing average 40mm thick grading Concrete with (1:2:4) using 12mm & down graded size black hard granite chips mixing of water proofing cement compound of approved quality over top of Roof, Terrace, including cost of scaffolding, scraping and cleaning the roof surface, plastering and finishing smooth to proper slope and gradient including cost of all materials, conveyance, taxes and sundries, T&P etc. All complete in all respect as per direction of the Engineer -in-charge. |
| 47 | VITRIFIED TILE FLOORING :- Providing and fixing Vitrified tile of specified size in floors on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 sand) with neat cement slurry . finishing the joint with epoxy based water proof grout to match the shades of the tiles, including 3 mm width or required spacer etc.including cost of all materials ,labours, taxes & royalties, conveyance, loading and unloading ,sundries , T&P etc . complete as per the specification & direction of Engineer-in-charge. (Note- Sample of tiles shall be approved before procurement and use) |
| 48 | VITRIFIED TILE SKIRTING :- Providing & laying vitrified tile of specified size in skirting cut from approved make confirming to IS-15622 specifications over 12mm thick cement mortar (1: 3) to proper line and level to a height as per design including cutting to required size and shape, fixing at corners and splays etc. including finishing the joints with epoxy based water proofing grout to match the color and shade of tiles and complete as per the design & drawing with cost of all materials, labour, taxes, conveyance ,royalties ,sundries and T&P etc. All complete as per the direction of Engineer -in-charge. (Note- Sample of tiles shall be approved before procurement and use) |
| 49 | KOTA STONE FLOORING :- Providing & laying Kota stone slab flooring of 16mm (average) thick over a 20mm thick based of cement mortar 1:4 to a proper slope, line and level including cutting to required size and shape, fixing at corners and splays etc. including finishing the joints with epoxy based water proofing grout to match the colour and shade of the flooring complete as per the design and drawings. Including cost of all labour, materials, royalties, loading and unloading, conveyance, sundries, T & P etc. All complete as per drawing and direction of the Engineer -in-charge. |
| 50 | GROUND FLOOR |
| 51 | FIRST FLOOR |
| 52 | KOTA STONE SKIRTING:- Providing & fixing Kota stone in skirting using 16mm thick Kota stone of approved quality, colour and size over 12mm thick cement mortar (1:3) jointed with neat cement slurry mixed and finishing the joint with epoxy based water proof grout to match the colour & shade of stone including cutting to a proper shape and size, Including cost of all labour, materials royalties, loading and unloading, conveyance, sundries, watering and curing etc. All complete as per drawing and direction of the Engineer -in-charge. |
| 53 | GROUND FLOOR |
| 54 | FIRST FLOOR |
| 55 | Providing & laying best quality Antiskid Ceramic floor tile of specified size of thickness 8-10mm of approved make confirming to IS-15622 specifications in floor over 20mm thick cement mortar (1:4) to proper slope, line and level including cutting to required size and shape, fixing at corners and splays etc. Including finishing the joints with epoxy based water proofing grout to match the color and shade of tiles complete as per the design & drawing with cost of all materials, labour, conveyance T&P etc. All complete as per the direction of Engineer -in-charge. |
| 56 | GROUND FLOOR |
| 57 | FIRST FLOOR |
| 58 | Providing and fixing ceramic glazed wall tiles of specified size of thickness 6-10mm conforming to IS: 15622 specifications of approved make and shade, in skirting and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and finishing the joint with epoxy based water proofing grout to match the shade. All complete as per the direction of Engineer-in-charge |
| 59 | GROUND FLOOR |
| 60 | FIRST FLOOR |
| 61 | GRANITE FLOORING :- Providing & laying Flame finish granite in floor using 16-18mm thick granite slab of approved quality, colour and size over 20mm thick cement mortar (1:4) and finishing the joints with epoxy based water proofing grout to match the colour & shade of tiles including cutting to shape, grinding and wax polishing, cost of all labour, taxes, materials, royalties, loading and unloading, conveyance, sundries, watering and curing etc. complete as per drawing and direction of the Engineer -in-charge. |
| 62 | GRANITE SKIRTING :- Providing & laying granite in Skirting using 16-18 mm thick granite slab of approved quality, colour and size over 12 thick cement mortar (1:3) and finishing the joints with epoxy based water proofing grout to match the colour & shade of tiles including cutting to shape, grinding and wax polishing, cost of all labour, materials, royalties, loading and unloading, conveyance, sundries, watering and curing etc. complete as per drawing and direction of the Engineer -in-charge. |
| 63 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. ( Area of slab over 0.50 sqm) |
| 64 | GROUND FLOOR |
| 65 | FIRST FLOOR |
| 66 | DOUBLE LEAF ALUMINUM OPENABLE GLASS DOOR :- Providing and fixing Anodized System Aluminum double leaf openable glass door made of TOSTEM / NCL ALLURO / ALUMIL make suitable for 1.6 KPA wind load with 50mm visible aluminium section width in the centre interlock. The system offered must be ride-in system with two glass panels moving inside the channel without any external overhung along with a provision for mesh panel on the third track. The extruded aluminium sections should be made from Grade 6063-T5 & Anodized with Tex guard coating. Corner connection will be Butt joint with using Nano gaskets for sealing. All other major Accessories should also be made by the same manufacturer. All Slider doors & windows will be centre locking with integrated Anti-lift in slider panel. Only EPDM gaskets should be used in all meeting points instead of Brush Pile. The outer frame Depth will be 72 mm +/- 3 mm The bottom frame must use a subframe and no direct grouting will be permitted on bottom frame directly. All glasses will be 5 mm clear toughened.The system should qualify Airtightness ASTM E283: 10.7m3/h.m2 at 75Pa of pressure, Water tightness ASTM E300: 240 Pa, Wind load resistance ASTM E330: 1600 Pa. |
| 67 | GROUND FLOOR |
| 68 | FIRST FLOOR |
| 69 | FIRE DOOR :- Providing and fixing of fire steel door of Wall Opening Material Specifications :- *Frame : GI 1.60 mm Shutter : GI 1.20 mm *Shutter Width / Active Shutter Width : 1,104.00 mm *Frame Profile (D X H):125.00 mm X55.00 mm *Frame Profile type : Kerf *Frame Joint Type: Miter Joint *Frame Rebate : Single Under Cut: 9.00 mm *Door type : Single leaf door Infill Material : Honey Comb *Vision Panel Active (VPW X VPH):200 mmX300 mm *Glazing type : Single *Vision Panel Type:Glazing Kit Kerb : NO *Handing : LH *Shutter Color :Ral 9001 Frame Color : Ral 9001 *Fixing Shield: Universal Anchor & including all cost of materials ,labour, conveyance, loading & unloding, T&P etc. complete as per direction of Engineer-in-charge etc. |
| 70 | Providing and fixing ISI Marked 35mm thick flush door shutters confirming to IS:2202(Part-1) decorative type, core of block board construction with frame of 1st class hard wood and well teak three ply veneering with vertical grains or cross bands and face veneers on both faces of shutters of approved design including cost of all door fittings, and fixtures etc. complete. |
| 71 | Ground Floor |
| 72 | First Floor |
| 73 | WPC DOOR FRAMES :- Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite /borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. |
| 74 | GROUND FLOOR |
| 75 | FIRST FLOOR |
| 76 | WPC DOOR :- Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water /moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge.. |
| 77 | GROUND FLOOR |
| 78 | FIRST FLOOR |
| 79 | Supplying, fitting and fixing of UPVC openable door with door frames of approved make with 6mm thick glass of approved quality complete with frame,fitting and fixtures etc. |
| 80 | Supplying and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with farme ,shutters, and all fitting and fixtures. |
| 81 | ROLLING SHUTTER :- Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.S/F rolling shutters required size M.S. laths including p/f 27.5cm long wire springs M.S. top cover -80x1.25mm M.S. laths with 1.25 mm thick top cover. |
| 82 | CONCRETE RAILING :- Providing and fixing Concrete hand rail of approved size,design and specification etc. to fixed with existing brick or rcc wall by using of cement concerete 1:2:4 etc. including painting with adequate primer and two coat of acrylic paint etc with cost ,conveyance of all materials, labours, fitting and fixture , T&P etc complete in all respect as per the direction of Engineer-in-charge. |
| 83 | Supplying, fitting and fixing of stainless steel of 304 grade in hand rail using 50mm dia of 2mm thick circular pipe with balustrade of size 32mm x 32mm x 2mm @ 0.90 mt c/c and stainless square pipe bacing of size 32mm x 32mm x 2mm in three rows in staircase as per approved design and specification, buffing, polishing etc with cost, conveyance,of all materials, labour T&P etc. required for the complete in all respect as per the direction of Engineer -in- charge. |
| 84 | M.S GRILLS FOR WINDOW :- Supplying, Fitting and Fixing M.S Grills of approved designs made out of M S Flat, Square bars/Round bars etc. of approved specifications / dimensions with necessary welded clamps fixed in proper position & plumb including a single coat of priming of approved quality metallic primer, making required holes in Masonary Walls / R.C.C Structures (where necessary) and grouting the clamps with C.C(1:2:4) with 12mm size black hard crusher broken granite stone chips, making good to the damages of Masonary Walls / R.C.C Structures including cost, conveyance, loading, unloading, stacking, of all materials , cost of all labours, staging, scaffolding, sundries, T&P etc. complete as per the direction of the Engineer-in-charge. |
| 85 | GROUND FLOOR |
| 86 | FIRST FLOOR |
| 87 | SYNTHETIC ENAMEL PAINT :- Painting with synthetic enamel paint of approved brand and manufacturer of required colour to give an even finish with two or more coats on new work of wood /steel over a coat of suitable shade with primer of approved brand and manufacturer's instructions including cost of all materials with taxes and transportation, all labour, scaffolding, sundries, T&P etc. All complete as per the direction of the Engineer -in-charge. |
| 88 | GROUND FLOOR |
| 89 | FIRST FLOOR |
| 90 | PUTTY WORK :- Finishing surface of walls with cement based wall putty of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of scaffoding staging charges with cost of all materials,taxes,labour T&P etc complete as per the direction of the Engineer -in-charge. |
| 91 | GROUND FLOOR |
| 92 | FIRST FLOOR |
| 93 | ACRYLIC EMULSION PAINT :- Wall painting with two or more coats of premium acrylic emulsion paint (Two or more coats ) of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour including cost, coveyance, loading and unloading, cost of all labour, sundries, T&P, scaffolding etc. required for the work and complete in all respect as directed by the Engineer in charge. |
| 94 | GROUND FLOOR |
| 95 | FIRST FLOOR |
| 96 | Providing and applying 2 coats of Plastic Emulsion Paint of approved quality and shade over Putty & wall primer of approved quality to surfaces (interior) including throughly brushing the surface free from foreign materials, sand papering smooth the intermediate coats,including of all materials, labour, conveyance, royalties, scaffolding, watering, curing, sundries, tools and plants etc as per the direction of Engineer-in-charge. (colour & shade to be approved before procurment & use) |
| 97 | WEATHER COAT PAINT :- Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat (Two or more coats ) of exterior primer applied @ 0.90 litre/10 sqm |
| 98 | GROUND FLOOR |
| 99 | FIRST FLOOR |
| 100 | TEXTURED PAINT :- Providing Two coat of Textured paint of approved make, quality and shade over the wall surface of the building over (Two or more coats ) of primer of approved make including cost of material, brushes, all labour, loading, unloading, scaffolding, T&P etc. as required for the work as per the direction of Engineer-in-charge. (colour & shade to be approved before procurment & use) |
| 101 | GROUND FLOOR |
| 102 | FIRST FLOOR |
| 103 | WIRE CUT BRICK :- Brick masonry work using Exposed Wire cut brick of size( 230x115x80) mm strength not less than 75kg/sqcm in cement mortar (1:3) as per the direction of Engineer in charge |
| 104 | GROUND FLOOR |
| 105 | FIRST FLOOR |
| 106 | MCM SLATE STONE CLADDING.:- Supply of MCM modified clay material - MCM slate stone -575x286 mm & 1150x575 of PHOMI make as per cpmpany standard dimension pattern colour as specified manufactured through unfired patented (Ref: US PATENT 8505840 B2 & European patent 2157139) manufacturing technology, bonded together by using low heat temperature and having CE approval with the thermal conductivity of 0.0590 W/M.K- EN 12667 (2001), thermal resistance 0.0568 m2 K/W- EN 12667 (2001) and fire insulation - class A- ASTM E84-15. The product should be patented from united states and europe and with certifications by IGBC, singapore green label and china green building material .MCM matrials should be fixed with suitable cement / polymer /epoxy based adhesive as per adhesive chart and aubstrate and per direction of engineer in-charge .Grouting should be done using filling and pointing method as per installation drawing provided ,and color of the grout should be as per the architects specification depending on the substrate and as per the direction of Engineer in-charge |
| 107 | Providing, supplying, and fixing Monier concrete roof tiles, ensuring a durable and weather-resistant roofing system. The tiles shall be high-quality, made of Portland cement, fine sand, water, and UV-resistant pigments, available in profiles like Elabana, Plano, Perspective, and Double Roman. Each tile, approximately 420 mm x 330 mm in size and weighing 4-5 kg, shall be installed with proper batten spacing (320-345 mm), corrosion-resistant nails or clips, and Monier underlay for waterproofing. Ridge and hip tiles shall be secured using the Monier Dry Ridge System to ensure proper sealing. The installation must follow IS 13801 standards, with correct alignment and overlap for optimal drainage and durability. Payment shall be based on the completed and accepted roofing area measured per square meter |
| 108 | Providing and laying cement concrete 1:2:4 using 12mm downgrade size chips etc including cost of all materials, conveyance, loading and unloading, all taxes and royalties, all labour, scaffolding, watering and curing, sundries and T&P etc. complete as per direction of the Engineer -in-charge |
| 109 | Supplying and fixing of 60mm thick cement concrete interlocking paver block of M-30 grade of approved make,design,colour and size made by block making machine with proper compaction laid in required pattern etc. complete in all respect confirming to IRC SP63:2018 |
| 110 | Supplying and fixing of precast kerb stone of size 600mm x 300mm x 150mm of M-30 grade of approved make ,design,colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect conforming to IS 5758:1984 |
| 111 | Trenching in ordinary soil upto a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling with a lead of 50m and making up the trenched to proper levels by filling with earth or earth mixed with sludge or/and manure before and after flooding trench with water (excluding cost of imported earth,sludge or manure). |
| 112 | Supplying and stacking of good earth at site including royalty and carriage(earth measured in stacks will be reduced by 20% for payment). |
| 113 | Supplying and stacking sludge at site including royalty and carriage upto 5 km lead complete (sludge measured in stacks will be reduced by 8% for payment). |
| 114 | Supplying and stacking at site dump manure from approved source, including carriage upto 1 km (manure measured in stacks will be reduced by 8% for payment). |
| 115 | (i)Screened through sieve of I.S designation 20mm |
| 116 | (ii)Screened through sieve of I.S designation 16mm |
| 117 | Spreading of sludge, dump manure and/ or good earth in required thickness as per the direction of the officer-in-charge (cost of sludge, dump manure and /or good earth to be paid separately) |
| 118 | Interpretation Centre |
| 119 | Grassing with selection no.1 grass including watering and maintainance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for moving including supplying good earth,if needed (the grass & good earth shall be paid separately) |
| 120 | Interpretation Centre |
| 121 | Anti termite treatment of lawn area through premise 30.50% I P. one liter premise diluted in 499 liters water and applying solution @ 1.00 litre solution per sqm lawn or bed area.(two application) i/c cost of chemical)and as per direction of officer-in-charge. |
| 122 | Interpretation Centre |
| 123 | Construction of granular sub-base by providing Close graded Granular subbase Grading-III material as per table 400-1, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density complete as per Clause 401 of MoSRT&H Specifications for Road & Bridge works (4th Revision) |
| 124 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, laying in uniform layers with paver in subbase/ base course on well prepared surface and compacting with vibratory roller to achieve the desired density as per Clause 406 of MoSRT&H Specifications for Road & Bridge works (4th Revision) |
| 125 | Supplying and fixing of 80mm thick cement concrete interlocking paver block of M-40 grade of approved make,design,colour and size made by block making machine with proper compaction laid in required pattern etc. complete in all respect confirming to IRC SP63:2018 |
| 126 | Supplying and fixing of precast kerb stone of size 600mm x 300mm x 150mm of M-30 grade of approved make ,design,colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect conforming to IS 5758:1984 |
| 127 | Rough stone dry packing in approns and revetments with hard granite stones (15cm to 30cm ) compacted and leveled to proper gradient including cost of all materials, conveyance and royalties, loading and unloading, including cost of all labour, sundries ,T & P etc. complete as per directions of the Engineer -in-charge. |
| 128 | Providing and fixing Dewatering Discel pump having discharge 40cum/hour including cost of operator, helper , maintenace of pump, shifting location, fuel cost etc as per direction of engineer in charge.(Pump with 20HP diesel engine for pumping of water. ( Measurement to be taken on actual hour basis based on the record in Lob book issued by the concerned department and signed by both parties) |
| 129 | Providing and placing LDPE Sheet of 5mm thickness inside the pond as per the direction of Engineer-in-charge. |
| 130 | Supplying, stacking and spreading of black cotton soil etc at site including royalty and carriage upto 5 km complete |
| 131 | Location based signage: The signage structure is a combination of wrought/cast iron pipe structure with sandstone base and iron brackets. Stainless Steel Panel flags with symboland text digitally H1625-RS printed on micro prismatic retro reflective boards conforming to type XI DG3 (diamond grade) 4000 series. Text language: Odia and English. Text height: Odia 55-60 mm; English 55-60 mm as per drawings & direction of Engineer in charge. |
| 132 | Wayfinding signage: Mild steel panels (with/without wrought iron frame) screwed directly on wall. Text printed digitally H1625 -RS printed on micro prismatic retro reflective boards conforming to type XI DG3 (diamond grade) 4000 series. Text language: Odia and English. Text height: Odia 40-45 mm English 40 - 45 mm Century 30 -35 mm. Icon height: 155 -175 mm as per drawings & direction of Engineer in charge. |
| 133 | Story signage: DG3 digital printing series (super high efficiency reflective sheeting) with alphabets/ numerical/ pictorials digitally printed and laminated using 1170c laminate in matt finish. The base corresponds to a specific kind of pedestal i.e. Kani Pista, with three mouldings with 4:5:6 proportion. Concrete structure with text etched and painted on top. Sandstone cladding at the base text. Language: Odia and English. Text height: Heading - 10 mm Supporting text - 8 mm as per drawings & direction of engineer in charge. |
| 134 | Cultural marker: Providing and fixing 600 x 600 x 1800 mm (LXWXH) culture marker made of stone block with CNC etching and carving designs fixed over MS support structure made up of 150 X150 mm MS pipes with weather proof paint and primer fixed on the sub structure inclusive of all necessary hardwares to make structure stable as per site with complete base work and foundation and research, scriptwriting, proofreading and copywriting of all the content in 3 language (Oriya , Hindi & Englidh )with designing the and developing the infographics of all the graphical representation, illustration, theoraticaland textual content placement of provided content along with development of print ready files for the fabrication and production as/design/drawing with complete work as per site engineer incharge. |
| 135 | Providing and fixing 2000 x 2000 x 3000 mm (LXWXH) culture marker made of Khandolite stone block with CNC etching and carving designs fixed over RCC structure with weather proof paint and primer fixed on the sub structure inclusive of all necessary hardwares to make structure stable as per site with complete base work and foundation and research, scriptwriting, proofreading and copywriting of all the content in 3 language (Oriya , Hindi & Englidh )with designing the and developing the infographics of all the graphical representation, illustration, theoraticaland textual content placement of provided content along with development of print ready files for the fabrication and production as/design/drawing with complete work as per site engineer incharge. |
| 136 | INTERIOR WORKS |
| 137 | PLAIN GYPSUM CEILING :- Providing fitting and fixing of false ceiling with aluminium anodised T section No - 3215 with 2'-0\\" center to center , l section No -1705 upto 15 micron on 4 walls to be fixed by means of steel screw and pvc plug and alluminium grid 2'-0\\"x2'-0\\" with 12. 5 mm th gypsum board suspended from ceiling etc complete excluding gst . The rate shall be exclusive of trap door which shall be paid for separately. including all cost of materials , labour, overheads T & P etc. |
| 138 | GROUND FLOOR |
| 139 | FIRST FLOOR |
| 140 | PAINTING ON PLAIN CEILING :- Providing and applying two coats of Plastic Emulsion Paint of approved quality and shade over a coat of putty & primer of approved quality to surfaces (interior) including throughly brushing the surface free from foreign materials, sand papering smooth the intermediate coats, including of all materials, labour, conveyance, royalties, scaffolding, watering, curing, sundries, tools and plants etc as per the direction of Engineer-in-charge. (colour & shade to be approved before procurment & use). |
| 141 | GROUND FLOOR |
| 142 | FIRST FLOOR |
| 143 | ACCOUSTIC GRID CEILING:-Providing & Fixing of Knauf Fibre Glass Acoustical Suspended Ceiling System Optra Microlook 90 Edge Tiles with Knauf Silhouette BR 15mm face exposed grid. The tiles shall have smooth laminated visual with Humidity Resistance (RH) of 95%, NRC 0.85 – 0.95(Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 standard, , Light Reflectance ≥88% as per ASTM E-1477, Colour Pebble White, Fire Performance of Class 0/1 as per BS 476 Part 6/7 with 15mm Square Microlook 90˚ edge and 8mm drop in module size of 600 x 600mm. It shall be suitable for Green Building application, with Recycled content of 85% Tiles Size 1200x300.. Test certificate of the use products shall be submitted after procurement of materials. including cost of all labours, materials, conveyance, fixing & fitting ,loading and unloading, scaffoldings, sundries and T&P etc all complete as per direction of the Engineer -in-charge. |
| 144 | FIRST FLOOR |
| 145 | WOODEN PANELING WITH LAMINATE :- Providing and fixing wooden panelling suitably fixed to the walls with 19 mm thick WPC, ply finished with 1 mm thick texture / suede laminate complete with necessary Hardwood, skirting , mouldings & teak wood beading on the edge etc. as per the detail design including the cost of all materials, labour, overheads and T & P etc. complete. The exposed frame work shall be finished with matt finsish enamel paints / polish with mellamine to match with the shade of the Laminates. excluding gst . |
| 146 | GROUND FLOOR |
| 147 | FIRST FLOOR |
| 148 | ACCOUSTIC PANELLING : Providing and Fixing Knauf Channeled Woodworks perforated panels of width 192mm, thickness of 15mm and length 2400 mm, made of a Moisture resistant fibre board substrate with a laminated facing as per the approved shade (Portland Maple, Sea Beech, Siam Wood & Mystique Walnut, Interior White, Alumina Pearl) and a melamine balancing layer on the reverse side. The boards shall have a special perforation pattern where the reverse surface has a “Helmholtz” fluted perforation with consecutive 3mm wide groove followed by 13mm of visible pane. The edges of the panel shall be “tongue-and-grooved” to fix special clips for installation and seamless visual. The back of the perforated panel shall have sound absorbing non-woven Soundex acoustic fleece hot pressed to achieve NRC of 0.6. (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 and Humidity Resistance (RH) of 70% with camber limit less than 1mm/1000mm and bow less than 1mm/300mm.The panels shall be mounted on special aluminium splines (keel) using inside clips provided by Knauf and approved by the Architect/ Engineer-in-Charge |
| 149 | Providing & supplying of painting & art work made out of acrylic painting on canvas with pvc framing , 5 mm th glass on top & 6 mm ply on back side of the painting as per design approved by eic . |
| 150 | Supplying and fixing walldecals/ wallpapers which are smooth / textured/ linear textured & 100% eco friendly , Non woven based . The film type is non woven based & vinyl coated . Overall length is 45.72 metre & overall width is 1220mm , 1524 mm , 610 mm . The product colour is white /offwhite and can be removed with water . Its shading coefficient is 0.93 & substrates are ABS, GlasS, Paint, PMMA , Polycarbonate . Surface finish is matte finish . as per design approved by eic . |
| 151 | Providing & fitting fixture of Non Woven Wrapper for Wall & Rigid Part 248 GSM Non woven Material with Water Resistant Coating as per the approved shade and design Including all cost of labour, taxes T & P etc as per the detail design & specifications approved by EIC . |
| 152 | Providing & fitting fixture of Frosted Film For Glass Brand: 3M Monomeric Calendered, White With Matt Finish, Thickness:- With adhesive: 3.5-4.5 mils (0.09-0.11 mm) Glue: Permanent, Pressure Sensitive Acrylic Glue , With Polycoated Craftpaper based Liner as per the approved shade and design Including all cost of labour , taxes T & P etc as per the detail design & specifications approved by EIC . |
| 153 | Providing & fitting fixture of Frosted Film For Glass Brand: 3M 3M™ Scotchcal™ Crystal Film Series Cast Premium Calendered, White With Matt Finish, Thickness: With adhesive: 3.5-4.5 mils (0.09-0.11mm) Glue: Permanent, Pressure Sensitive Acrylic Glue, With Polycoated Craftpaper based Liner as per the approved shade and design Including all cost of labour , taxes T & P etc as per the detail design & specifications approved by EIC . |
| 154 | Providing & supplying ss sinage of size 150mmx150 mm as per the approved shade and design Including all cost of labour , T & P etc as per the detail design & specifications approved by EIC |
| 155 | Providing & supplying of sinage made out of lazer cut retro letter on acp with ms frame & all necessary asscories Including all cost of labour , T&P etc as per the detail design & specifications approved by EIC |
| 156 | Supplying and fixing of following modular furniture, as per the detail design and specification adjustment required to material with the shade and finish etc. including cost of all material, loading and unloading ,installing etc all complete as for the as per the direction of Engineer-in-Charge/Architects. (MAKE :- GODREJ, FEATHERLITE, SPACEWOOD OR EQUIVELENT) |
| 157 | FINESE 5026+ ERU+ PEDESTAL+ BACK UNIT (TABLE SIZE - 1500Wx 750Dx 740H, ERU SIZE - 1050W x 450D x 705H, BACK UNIT SIZE - 1280W x 425D x 705H) IN MM |
| 158 | AERO HIGH BACK CHAIR |
| 159 | OXBO VISITOR CHAIR |
| 160 | BROADWAY V2 3SEATER WITH ARMS |
| 161 | OPULENT CENTRE TABLE |
| 162 | DUSTBIN 12X16 |
| 163 | ARCATIC ROUND DINING TABLE WITH 2 NOS ALURE DINIGN CHAIR |
| 164 | E 4 SEATER DINING TABLE WITH CHAIR MODEL - GRANDE 4 SEATER DINING TABLE WITH GRANDE CHAIR |
| 165 | GREET CHAIR |
| 166 | GRAPH SOFA 1800 GREEN |
| 167 | EASY RACK 6615 (SIZE - 1800Hx900Wx450) IN MM |
| 168 | LANDSCAPE |
| 169 | Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly leveling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with Vermi compost or / and manure before and after flooding trench with water |
| 170 | Supplying and stacking of good earth at site including royalty and within all lead and lift complete . The soil should be labrotary tested for fertility as per the direction of E-I-C at the own cost of bidder. |
| 171 | Supplying and stacking sludge at site including royalty and carriage upto 5 km lead complete (sludge measured in stacks will be reduced by 8% for payment). |
| 172 | Rough dressing the trenched ground including breaking clods. |
| 173 | Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation. |
| 174 | Fine dressing of the ground. |
| 175 | Supplying and stacking at site dump manure from approved source, including carriage upto 1 km (manure measured in stacks will be reduced by 8% for payment). |
| 176 | (i)Screened through sieve of I.S designation 20mm |
| 177 | (ii)Screened through sieve of I.S designation 16mm |
| 178 | Spreading of sludge, dump manure and/ or good earth in required thickness as per the direction of the officer-in-charge (cost of sludge, dump manure and /or good earth to be paid separately) |
| 179 | Grassing with selection carpet lawn grass including watering and maintainance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for moving including supplying good earth |
| 180 | Anti termite treatment of lawn area through premise 30.50% I P. one liter premise diluted in 499 liters water and applying solution @ 1.00 litre solution per sqm lawn or bed area.(two application) i/c cost of chemical)and as per direction of officer-in-charge. |
| 181 | Grassing with selection carpet lawn grass including watering and maintainance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for moving including supplying good earth |
| 182 | Anti termite treatment of lawn area through premise 30.50% I P. one liter premise diluted in 499 liters water and applying solution @ 1.00 litre solution per sqm lawn or bed area.(two application) i/c cost of chemical)and as per direction of officer-in-charge. |
| 183 | Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) |
| 184 | Holes 90 cm dia, and 90 cm deep |
| 185 | Holes 45 cm dia, and 45 cm deep |
| 186 | Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water) |
| 187 | Trees Plant |
| 188 | plantation per Shrub |
| 189 | Providing and stacking of Beloperone species of height 30-45 cm. in poly bags of size 20 cm as per direction of the officer-in-charge. |
| 190 | Providing and stacking of Calliandra hybrida of height 105-120 cm., well branched, bushy in big size HDPE bag as per direction of the officer-in-charge. |
| 191 | Providing and stacking of Cassia biflora of height 90-105 cm., well branched, bushy in big size HDPE bag as per direction of the officer-in-charge. |
| 192 | Providing and stacking of Dombeya mastersii of height 60-75 cm. with 4- 5 branches in bag of size 25 cm as per direction of the officer-in-charge. |
| 193 | Providing and stacking of Ficus panda of height 60-90 cm, with 8-10 branches, and healthy foliage, bushy in big size HDPE bag as per direction of the officer-in-charge. |
| 194 | Bottle palm ht. 210-240 cm bottom girth 30-35 cm well developed in big HDPE bag |
| 195 | Ficus benjamina (green) height 150-165 cm., bushy with healthy branches and lush green foliage in big size HDPE bag |
| 196 | Foxtail palm ht. 240-270 cm bottom girth 35-40 cm well developed in big size HDPE bag |
| 197 | Supplying and planting below mentioned best quality container- grown healthy trees of species as specified and with an average height and as age as mentioned as per Schedule of Rates,Analysis of Rates and Specifications (Horticulture & Landscaping) 2020 and direction of Engineer in Charge. All trees to be approved by Engineer-in-Charge before planting. |
| 198 | Neem of height 3m - 4m (3 to 4 years old) well developed with thick stem |
| 199 | Karanja of height 4m -5m (3 to 4 years old) well developed with thick stem |
| 200 | Akashmalli of height 3m - 4m (3 to 4 years old) well developed with thick stem |
| 201 | Amla of height 3m - 4m (3 to 4 years old) well developed with thick stem |
| 202 | Mango of height 4m -5m (3 to 4 years old) well developed with thick stem |
| 203 | Kochila of height 4m -5m (2 to 3 years old) well developed with thick stem |
| 204 | Champa (white,red, pink) of height 3m-4m (2 to 3 years old) well developed with thick stem |
| 205 | Baul of height 4m -5m (3 to 4 years old) well developed with thick stem |
| 206 | Ashoka of height 4m -5m (3 to 4 years old) well developed with thick stem |
| 207 | Arjun of height 3m-4m (2 to 3 years old) well developed with thick stem |
| 208 | Bahunia purpurea (kanchan) of height 4m-5m (3 to 4 years old) well developed with thick stem |
| 209 | Peepal/ Banyan Tree of height 4m -5m (3 to 4 years old) well developed with thick stem |
| 210 | Supplying and planting below mentioned best quality container- grown healthy shrubs/plants of species as specified and with an average height and as age as mentioned as per Schedule of Rates,Analysis of Rates and Specifications (Horticulture & Landscaping) 2020 and direction of Engineer in Charge. All trees to be approved by Engineer-in-Charge before planting. |
| 211 | Aparajita (black & height) of height up to 1 mtr (1 to 2 yrs) old |
| 212 | aswagandha of height up to 2 mtr (1 to 2 yrs) old |
| 213 | dhannantari of height up to 2 mtr (1 to 2 yrs old) |
| 214 | ganga siuli of height up to 2 mtr (1 to 2 yrs old) |
| 215 | kamini of height up to 1 mtr (1 to 2 yrs old) |
| 216 | rukunaa hatapochaa of height up to 1 mtr (1 to 2 yrs old) |
| 217 | sadabihari (red & white) of height up to 1 mtr (1 to 2 yrs old) |
| 218 | Jasmine of height up to 1 mtr (1 to 2 yrs old) |
| 219 | Supply and applying of chemical fertilizer before or after as per requirement, as per Schedule of Rates,Analysis of Rates and Specifications (Horticulture & Landscaping) 2020 and direction of Engineer in Charge. |
| 220 | Urea / Ammonium Sulphate (30gm/M²) |
| 221 | Bone Meal (150gm/M²) |
| 222 | Potassium Sulphate or Murate of Potash (20gm/M²) |
| 223 | Provision of insecticides (10ml IN 10 ltr/M²) |
| 224 | Providing, supplying, transporting, dressing, polishing, erecting and fixing stone benches of approved design and dimensions, made of machine-cut natural stone/granite/sandstone with suitable supports, including all labour, materials, tools, tackles, loading, unloading, carriage, foundation, fixing with cement mortar/concrete, finishing, cleaning and all incidental works complete in all respects as per approved drawing, specification and direction of the Engineer-in-Charge. |
| 225 | INTERNAL & EXTERNAL ELECTRIFICATION AND ALLIED WORKS FOR CONSTRUCTION OF PROPOSED RANIPUR JHARIAL PART 2 |
| 226 | Sub-Head I (modular Wiring Items) |
| 227 | The GFC Electrical drawing must be approved by Engineer in charge of OTDC before commencement of electrical work |
| 228 | Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 229 | GROUP-A |
| 230 | GROUP-B |
| 231 | GROUP-C |
| 232 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( ( flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 233 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( ( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius ) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 234 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)(( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 235 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 236 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) |
| 237 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5) |
| 238 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(LFDB TO LBDB) (4X6+2X4) |
| 239 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit .(LFDB TO FLOOR PANEL TO TPN BDB power) (4X10+2X6) |
| 240 | Supplying and installation of AC Point having 16-20A DP MCB, C series with enclosure, Schneider/Siemens/Legrand/ABB c of suitable size as required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 1 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 241 | Supplying,fixing of 2 nos 6A Plug on the separate board with complete fitting by 02 no of 6A switch & socket(modular type)( (flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 242 | Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make- Havells/Anchor as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 243 | S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 244 | S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) |
| 245 | Sub-Head II (Light fitting Fixture & Fan) |
| 246 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 247 | Supply, Installation, Testing and Commissioning of Duct mounted Single skinned Circular Inline Centrifugal Fan for Toilet Ventilation with direct driven Backward-curved impellers.The Fan has external rotor motor suitable for 1~, 230V, 50 Hz power supply. MAKE - SYSTEMAIR/ GREENHECK/ ELTA/Airflow6000 CFM @ 15mm MMWG static pressure |
| 248 | Supply & Fixing of Air Distribution Duting fabricated with Class VI GI Sheet(180 GSM) Complete With Supports, dampers, guiding vanes, access doors, MS Angle, Fire inhibiting gaskets, Nuts, bolts and all oyher accessories in accordance with approved drawing and the Specification. (Make:- Jindal/ Sail/ Tata)22 gauge (0.80 mm thickness) |
| 249 | 24 gauge (0.63 mm thickness) |
| 250 | Supply, erection, testing & commissioning of Aluminium powder coated grills/diffuser without VCD having flange all around.Make-Glenstorm/Airflow/Systemaire |
| 251 | Supply, Installation, Testing and Commissioning of bird screen made by stain less steel for fans |
| 252 | Supplying, installation, testing and commssioning of 1200 mm sweep Copper wound BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix /Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years. |
| 253 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 254 | SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years . |
| 255 | SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years |
| 256 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge .(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved. |
| 257 | SITC of recess/surface mounted 2'x2'(595mmx595mmx70mm(+/-5%) square shaped LED made up of CRCA powder coated housing with lumen efficacy not less than 140lm/W and lumen output not less than 3600 lumens , CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty) as required as per direction of Engg.-in-Charge (Make: Panasonic/ LT/ Havells / Philips/ Wipro/ Crompton/ Bajaj) . The luminaire must be Replacement Warranty will be 5 years. |
| 258 | SITC of indoor rated IP20 5mtr LED Strip, operating in an ambient temperature of 0⁰C to 45⁰C. Operating at 50Hz frequency, housing of Polymide double sided PCB. LEDs used in the product shall comply with IEC 62471 for Photo-biological safety. Luminaire should have 70lm/mtr and total 350lumen in maximum 25Watt for 5mtr role. The LED shall comply with L70 life of 35000 burning hours tested at maximum current. The LEDs used should be with CCT of 3000/4000/5700 K. LED Driver shall be external type, suitable to operate in input voltage range of 140V to 300V (nominal rated voltage – 240V) with 3KV internal surge protection, Power factor of minimum 0.9, driver efficacy of minimum 85% and total harmonic distortion (THD) of less than or equal to 20% should be integral to the luminaire. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 259 | SITC of 20 watt LED focus track light with 1mtr track as per the direction of Engineer-in-charge. (Make:K-LITE Model No- 23678 Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years . |
| 260 | SITC of 12 watt LED COB light made up of die cast aluminium body & Clear polycarbonate diffuser with 100Lm/Watt, Citizen COB, IP-54, SDCM<3, CRI 90, CCT - 3000K, as per the direction of Engineer-in-charge. (Make: K-Lite Model No - 28178 / Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years . |
| 261 | BDBS,DB,AC DB,FLOOR PANELS,MCBS |
| 262 | Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB Itus as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years |
| 263 | Supply and fixing of 8 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator).Warranty on DB is 3 years |
| 264 | 4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years (FOR LIGHT,ComputerDB) |
| 265 | 8 Way(8+24) Way TPN MCB DD DB Horizontal Type suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door(FOR POWER & INDOOR AC DB)Warranty on DB is 3 years |
| 266 | 2+4 way MCB Enclosure DB (GLAZED door)(only each EM. CONNECTION UPS LOAD)Warranty on DB is 3 years |
| 267 | Supplying and fixing 6- 32 amps rating, 240 volts, C series, Double poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 years . |
| 268 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series, single poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 . the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 years. |
| 269 | Supplying and fixing 40Amps 4P 415 volts, MCB Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 years |
| 270 | Supplying and fixing 40 Amps rating, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year. |
| 271 | Supplying and fixing 40 amps rating, 240 volts, C series,10KA breaking capacity, Double poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year. |
| 272 | Supplying and fixing 63Amps 4P 415 volts MCB 415 volts, C series,10KA breaking capacity, Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB with connections as per direction of Engg.-in-Charge..Warranty on MCB is 3 years. |
| 273 | Supplying and fixing 63Amps 4P 415 volts RCCB 30 mA Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The RCCB should be Replacement Warranty will be 1 year. |
| 274 | Supplying and fixing 40 Amps rating,C series,10KA breaking capacity, 2P, 415 volts, RCCB 30mA . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year |
| 275 | CABLING AND END TERMINATION MAIN AREA |
| 276 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. |
| 277 | 4core x 16 sq mm |
| 278 | 3.5core x 150 sq mm intp panel ic |
| 279 | 3.5core x 95 sq mm |
| 280 | 3.5core x 50 sq mm |
| 281 | 3.5core x300 sq mm |
| 282 | LAYING OF CABLE |
| 283 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 284 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 120 SQ. MM but not exceeding 400 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 285 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 286 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 287 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in open duct etc as required as per direction of Engg.-in -charge. |
| 288 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM in open duct 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 289 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 290 | Supplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
| 291 | Supplying and making end termination with 4 core x16 sq mm brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
| 292 | Supplying and making end termination with 3.5 core x95 sq mm brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
| 293 | Supplying and making end termination with 3.5 core x150 sq mm brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
| 294 | Supplying and making end termination with 3.5 core x50 sq mm brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
| 295 | Supplying and making end termination with 3.5 core x300 sq mm brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
| 296 | Providing,fixing and laying of following dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. |
| 297 | 50 mm dia |
| 298 | Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials(make-Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster ) |
| 299 | Supplying,laying of 3cx2.5 sq.mm AL armoured XLPE cable with insulated cover with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials(make-Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster ) |
| 300 | Supplying,laying of 3cx6 sq.mm AL. armoured XLPE cable with insulated cover with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials(make-Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster ) |
| 301 | Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials |
| 302 | 50 mm dia |
| 303 | PANELS |
| 304 | MAIN CONTROL PANEL NEAR HALL AREA |
| 305 | S/I/T&Commissioning of LT OUTDOOR floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.3P+N Type 1+2 SPD 65 kA with 63A 4P MCB,10kA, Cseries shall be installed in the incomer. 80X10MM Separate Aluminium Earth bus bar should be installed.Provision of cable alley chamber is mandatory. All the feeders shall have ON/OFF/TRIP indication. |
| 306 | In commer-1-01 number of 800A 4P Icu=100%Ics,36Ka LSIG MCCB with microprocessor release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula In commer-2- 01 number of 160A 4P Icu=100%Ics,25Ka MCCB with TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula Changeover- 01 no of 160A 4P onload changeover switch ( DG 01 NO)(Make-Legrand/Siemens/Schneider/ABB) Busbar-1&2 04 numbers of 900Amps Aluminium busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing) Out going- 02 numbers of 400 Amps 4P MCCB.Icu=100%Ics,25Ka TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula Out going- 01 numbers of 200 Amps 4P MCCB.Icu=100%Ics,25Ka TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula Out going- 02 numbers of 125Amps 4P MCCB.Icu=100%Ics,25Ka TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula Out going- 02 numbers of 160Amps 4P MCCB.Icu=100%Ics,25Ka TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula Out going- 6 numbers of 100-63Amps 4P MCCB.Icu=100%Ics,16Ka TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula Outgoing- 4 nos. 32A 4P MCB, C series, 10 ka , Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 Outgoing- 8 nos. 32A 2P MCB, C series, 10 ka , Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 Instrument- (i) 06 numbers phase indicating lamp with toggle switch & HRC fuse.(ii) 02 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication(iii) All the MCCB outgoing feeders shall have digital ammeter with CT of suitable class 1 rating.(Make-Legrand/Siemens/Schneider/ABB) |
| 307 | MAIN CONTROL PANEL INTERAPETION CENTER |
| 308 | S/I/T&Commissioning of LT INDOOR floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.3P+N Type 2 SPD 40 kA with 63A 4P MCB,10kA, Cseries shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed.Provision of cable alley chamber is mandatory.All the feeders shall have ON/OFF/TRIP indication. |
| 309 | In commer-1-01 number of 200A 4P Icu=100%Ics,25Ka MCCB with TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula In commer-1-01 number of 125A 4P Icu=100%Ics,25Ka MCCB with TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula Changeover- 01 no of 125A 4P onload changeover switch ( DG 01 NO)(Make-Legrand/Siemens/Schneider/ABB)Busbar-1&2 04 numbers of 300Amps Aluminium busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing) Out going- 6 numbers of 6-32A 2P MCB10KA,C series ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) Out going- 4 numbers of 6-32A 4P MCB10KA,C series ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) Out going- 8 numbers of 63A 4P MCB10KA,C series ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) Out going- 8 numbers of 40A 4P MCB10KA,C series ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse. (ii) 01 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication |
| 310 | MAIN CONTROL PANEL 6 NOS SHOP |
| 311 | S/I/T&Commissioning of LT INDOOR floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.3P+N Type 2 SPD 40 kA with 63A 4P MCB,10kA, Cseries shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed.Provision of cable alley chamber is mandatory.All the feeders shall have ON/OFF/TRIP indication. |
| 312 | In commer-1-01 number of 100A 4P Icu=100%Ics,25Ka MCCB with TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula Busbar-1&2 04 numbers of 200Amps Aluminium busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing) Out going- 8 numbers of 6-32A 2P MCB10KA,C series ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) with provission for 1PH KWH meter(10-40A) Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse. (ii) 01 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication |
| 313 | CABLE TRAY /RACE WAY FOR DISTRIBUTION OF POWER |
| 314 | Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. |
| 315 | Supply ,installation ,testing & commissioning of 10 KVA UPS SYSTEM WITH IGBT based inverter system, true online double conversion system, inbuilt isolation transformer & automatic phase sequence corrector of 3ph in put to 1 ph output,415V, with built in BMS with battery back up up to 30 minutes with MS Rack for battery Housing, DC cable 7 Mtr with SFU and links for installation (Battery required: 12V, 42AH, 20 No.s) protection for fault by OL,UV,EF,GF,OC,Ph. (Make:Numeric/APC/ Vertiv/) , as per direction of Engg.-in-Charge. Warranty period of all accessories & component & system must be 2 years & complete test certificate must be submitted along with ups including component list & SLD. for INDOOR HALL building |
| 316 | EARTHING |
| 317 | Supplying,installation,testing & commissioning Of Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required as per direction of Engg. in charge. |
| 318 | Supplying & laying of 6 swg GI WIRE at 0.5m below the ground as strip earth electrode including connection/termination with nut ,bolt ,spring washer etc as required(jointing shall be done by over laping and with 2 sets of brass nut ,bolt & spring washer spaced at 50mm . as required as per direction of Engg. in charge. |
| 319 | Supplying & laying of 25mm x 5 mm GI strip at 0.5m below the ground as strip earth electrode including connection/termination with nut ,bolt ,spring washer etc as required(jointing shall be done by over laping and with 2 sets of brass nut ,bolt & spring washer spaced at 50mm . as required as per direction of Engg. in charge. |
| 320 | LIGHT SYSTEM EXTERNAL |
| 321 | S/F of Street light- 90W,120 lm/w efficacy ,IP PC Lens new generation energy saving & environmental friendly long life versatile pressure die-cast alluminium IP66, IK 08 roadway luminaire with high power LED as light source with acrylic cover (Make-Panasonic/LT/Havells /Philips/Wipro/Crompton/Bajaj) (5Years Warranty) |
| 322 | Supply of 8 mtr long hot dip Galvanized Octagonal pole manufactured from HT steel(with decorative single arm) as per BS EN 10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 155 MM A/F of 3 mm thick or more , base plate as per IS 2062 complete with 4 nos. En 8 grade foundation bolts to withstand basic wind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles: Utkarsh/Bajaj/RR Ispat/Vakarangee as per direction of Engg. in Charge. |
| 323 | Supply of 8 mtr long hot dip Galvanized Octagonal pole manufactured from HT steel(with decorative DOUBLE arm) as per BS EN 10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 155 MM A/F of 3 mm thick or more , base plate as per IS 2062 complete with 4 nos. En 8 grade foundation bolts to withstand basic wind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles: Utkarsh/Bajaj/RR Ispat/Vakarangee as per direction of Engg. in Charge. |
| 324 | Installation of pole by making the suitable size foundation by embeding the pole 1 mtr into the ground with necessary civil work and fixing the light on the pole equievalant make ISI marked as approved as per direction of Engg. in Charge. |
| 325 | Supply, Installation, Testing & Commissioning of of IP66 LED (50-60)w Post Top Fixture with Body made of Pressure Die Cast Aluminium Housing for Optimal thermal Conductivity. With UV Stabilized PC Compound Lens for Good Impact Resistance. High Efficiency Driver with necessary safety Protection against Short Circuit, Miswiring,Over Voltage and Surge Protection of upto 10kV ( 6kV Internal and 10kV External SPD of IP67). System Efficacy>100lpw. THD<10%.Submission of LM79,LM 80 report from State/central accredited NABL laboratory).CRI>=80, PF>.95. CCT - 5700/4000K.Impact Resistance IK07.Operating Voltage Between (140-270)V. Avg life of 50,000 Burning [email protected] the light fixture and the Driver Should be BIS Approved. Before final procurement, the final design shall be approved by the concerned client and Engineer-in-charge.The price inclussive of 3 meter long aesthetically designed decorative light pole with Cast Aluminium base and cast aluminium in middle of the Pole . Pole shall made up of Mild Steel Body and coated with zinc rich primer & pure polyester powder coating and finished with black & gold embellishment. The pole shall be suitable for fitting of 50-60W decorative Heritage Light . Dimension of light must be Ø400mm dia and 800mm height. Body size of the pole will Ø88mm dia. The Pole shall have base Plate Ø230x12mm thick with provision for founation bolt fittings. Pole is Compatible for 70mm size for cable entry & exist. Junction Box service door is made up cast aluminium of size 325 X 90mm and the control gear tray only is prewired with 2.5sq mm cable, 6A SP MCB and 4pole studd connector for loop-in loo-out arrangement. The lighting manufactor must have own NABL Approved lab to justify the lumen efficacy, IP-66 protection and other parameters as required by the Engineer-in- Charge.(Make: K -lite Pole KP-12011-300 + KL-5444 Luminaries / LT/panasonic/Havells /Philips/Wipro /Crompton/Bajaj). |
| 326 | Supply, Installation, Testing & Commissioning of of IP66 LED (50-60)w Post Top Fixture with Body made of Pressure Die Cast Aluminium Housing for Optimal thermal Conductivity. With UV Stabilized PC Compound Lens for Good Impact Resistance. High Efficiency Driver with necessary safety Protection against Short Circuit, Miswiring,Over Voltage and Surge Protection of upto 10kV ( 6kV Internal and 10kV External SPD of IP67). System Efficacy>100lpw. THD<10%.Submission of LM79,LM 80 report from State/central accredited NABL laboratory).CRI>=80, PF>.95. CCT - 5700/4000K.Impact Resistance IK07.Operating Voltage Between (140-270)V. Avg life of 50,000 Burning [email protected] the light fixture and the Driver Should be BIS Approved. Before final procurement, the final design shall be approved by the concerned client and Engineer-in-charge.Make-Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj/K-Lite.The price inclussive of of 4 meter long aesthetically designed decorative light pole with Cast Aluminium base and cast aluminium in middle of the Pole . Pole shall made up of Mild Steel Body and coated with zinc rich primer & pure polyester powder coating and finished with black & gold embellishment. The pole shall be suitable for fitting of 50-60W decorative Heritage Light . Dimension of light must be Ø400mm dia and 800mm height. Body size of the pole will Ø88mm dia. The Pole shall have base Plate Ø230x12mm thick with provision for founation bolt fittings. Pole is Compatible for 70mm size for cable entry & exist. Junction Box service door is made up cast aluminium of size 325 X 90mm and the control gear tray only is prewired with 2.5sq mm cable, 6A SP MCB and 4pole studd connector for loop-in loo-out arrangement. The lighting manufactor must have own NABL Approved lab to justify the lumen efficacy, IP-66 protection and other parameters as required by the Engineer-in- Charge.(Make: K -lite Pole KP-12011-400 + KL-5444 Luminaries/LT/panasonic/Havells /Philips/Wipro /Crompton/Bajaj). |
| 327 | Supplying, Erection, Fixing, connection & testing of 50W LED Heritage GATE Light, Dimension of light must be Ø400mm dia and 800mm height, IP 66, IK07, amb. temp -10 to 45 degree celcious, CT 3000-5700K,,50000 HRS, CRI 70, 120 Lm/W system efficacy,driver efficiency >/ 85%,dia case aliminium housing,Clear Acrylic diffuser of Make-K-LITE Model No - 25444/LT/panasonic/Havells /Philips/Wipro /Crompton/Bajaj as approved maintenance free having 2 years warranty G.I P ipe with braket including MCB box & including with foundation as per the Drawing for inspection as required & as per direction of Engg.-in-Charge. |
| 328 | Supply, Installation, Testing & Commissioning of of IP65 (16)w Bollard Fixture with Body made of Extruded Aluminium /Mild steel Pole & PDC Aluminium Housing for Optimal thermal Conductivity. With UV Stabilized Injection Moulded Diffuser for Soft and even light distribution. High Efficiency Driver with necessary safety Protection against Short Circuit, Miswiring,Over Voltage and Surge Protection of upto 10kV ( 4kV Internal and 10kV External SPD of IP67) THD<10%. CRI>70, PF>.95. CCT - 5700/4000/3000K.Impact Resistance IK05.Operating Voltage Between (100-275)V. Avg life of 50,000 Burning [email protected] the light fixture and the Driver Should be BIS Approved.Before final procurement, the final design shall be approved by the concerned client and Engineer-in-charge. Make-K-K -lite Bollard KL-25582/Philips/LT/PANASONIC/Havells/Bajaj/Crompton/Wipro |
| 329 | FOCUS LIGHT |
| 330 | Supply, Installation, Testing and Commissioning of 18W LED Focus Light having CCT 3000K +/-355K as per ANSI , CRI>80, SDCM<3. The fixture housing must be Made of extruded Aluminium housingfor better thermal healing & Powder coated by Corrosion resistant Nano coating technology. Luminaire must have minimum Ingress protection of IP66. The fixture should be equiped with stabilized Injection moulded special PC diffused optics ensuring low glare. The luminaire must have Integral high efficiency electronic thermally isolated constant current IP66 driver with operating voltage range of 90-205V, power factor > 0.95, THD < 10%, with Inbuilt surge protection of : 3kV and upgraded with integrated External IP67 protected SPD of 10KA surge protection .Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, EMC : EN 55015. CE Certified, ROHS compliant, BIS Certification for Luminaires & Drivers. The lighting manufactor must have own NABL Approved lab to justify the lumen efficacy, IP-66 protection and other parameters as required by the Engineer-in- Charge. Make: K -lite Nebula KL-22782/LT/Havells/panasonic/Philips/Wipro /Crompton/Bajaj). |
| 331 | Supply, Installation, Testing and Commissioning of 50W LED Focus Light having CCT 3000K +/-355K as per ANSI , CRI>80, SDCM<3. The fixture housing must be Made of extruded Aluminium housingfor better thermal healing & Powder coated by Corrosion resistant Nano coating technology. Luminaire must have minimum Ingress protection of IP66. The fixture should be equiped with stabilized Injection moulded special PC diffused optics ensuring low glare. The luminaire must have Integral high efficiency electronic thermally isolated constant current IP66 driver with operating voltage range of 90-205V, power factor > 0.95, THD < 10%, with Inbuilt surge protection of : 3kV and upgraded with integrated External IP67 protected SPD of 10KA surge protection .Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, EMC : EN 55015. CE Certified, ROHS compliant, BIS Certification for Luminaires & Drivers. The lighting manufactor must have own NABL Approved lab to justify the lumen efficacy, IP-66 protection and other parameters as required by the Engineer-in- Charge. (Make: K -lite Navi KL-26805/LT/Havells/panasonic /Philips/Wipro /Crompton/Bajaj). |
| 332 | CABLING |
| 333 | Supplying and laying of one number PVC insulated armoured and PVC sheathed XLPE AL. conductor power cable of 1.1 KV grade POLYCAB/FINOLEX/HAVELLS/KEI/RR Kabel/Gloster of following size cables as per direction of Engg.-in-Charge.Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials |
| 334 | 4core x 16 sq mm (OFP TO IND. TIMER PANEL) |
| 335 | 4 core x 4 sq mm (for small power/LIGHT TO POLE) |
| 336 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 337 | Supplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
| 338 | Supplying and making end termination with 4 core x16 sq mm brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
| 339 | Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of reputed make,ISI marked with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. Make-POLYCAB/FINOLEX/HAVELLS/KEI/RR Kabel/Gloster |
| 340 | Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials |
| 341 | 50 mm dia |
| 342 | S/I/T&Commissioning of LT OUT DOOR FLOOR mounted cubical type IP66 based panel made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. (FOR USE) with 63A TPN MCB 01 NO,1 no. Astronomical digital timer, AUTO MANUAL(with start and stop push button) SELECTOR 63 A 3P contactor, OLR,RYB,ON,OFF trip indication, Type-II SPD 40ka ,,04 nos 10A 4P MCB,C,10KA as outgoing MCB( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period 1 years of acceptance of materials |
| 343 | Highmast lighting |
| 344 | Supply,installation,testing and commissioning of 12M high mast shaft in two sections suitable for 55 m/sec wind speed along with head frame, luminaires carriage suitable for 6 luminaires in symmetrical arrangement and other accessories manufactured in factory. ( Bottom 360mm / Top -150mm, 3mm thickness, 445PCD, diameter of base plate 520mm including supplying of raising lowering system comprising double drum winch, 6mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box, lightning finial. (Wiring material from JB to individual luminaire & MCB in base compartment are not included and are a part of installation)along with foundation bolts manufactured from special steel along with nuts, washers, anchor plate and common template along with Construction of shallow foundation with M20 grade concrete for the highmast considering the safe soil bearing capacity at site as 10 T/sqmtr at 2 metre depth with all materials and labour.Erection of the high mast with the help of suitable tools and plants, wiring of luminaires with all wiring materials like PVC insulated PVC sheathed flexible cable of suitable copper conductor cores of 1.5 sq. mm, lugs, MCB and all labour . Provision of GI pipe earthing for High mast with 2.5 M long 40 mm dia GI Pipe including connection to High mast earth terminal with 25 x 3 mm GI flats with all materials and labour. (2nos per mast required) Approved colour after treatment along with provision of masonary pedestal duly finished with plaster and painting with GI pipe for cable entering as required.. (2nos per mast required) (Make:-Bajaj/ Utkarsh/ Vakrangee/RR ISPAT/Valmont |
| 345 | SITC of 250W Outdoor Flood LED lights with polycarbonate module lens provided with silicon gasket for efficient ingree protection with silicon potted driver, IP66, IK08 , bottom opening maintanance , LPW not less than 120.Input Voltage: 85-265V AC ,Body : pressure Die cast Aluminium housing designed to act as heat sink for proper heat dissipation, IP66, CRI greater than eual to 70, burning hours 50,000 hrs, pf greater than 0.95, THD less than 10% as per the Drawing for inspection as required Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj as rerquired & as per direction of Engg.-in-Charge.The luminaire should be Replacement Warranty will be 2 years . |
| 346 | LED type single dome aviation obstruction light. (Make:-Bajaj/ Utkarsh/ Vakrangee/RR ISPAT |
| 347 | S/I/T&Commissioning of LT OUT DOOR FLOOR mounted cubical type IP66 based panel made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. (FOR USE) with 63A TPN MCB 01 NO,1 no. Astronomical digital timer, AUTO MANUAL(with start and stop push button) SELECTOR 63 A 3P contactor, OLR,RYB,ON,OFF trip indication, Type-II SPD 40ka ,,04 nos 10A 4P MCB,C,10KA as outgoing MCB( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period 1 years of acceptance of materials |
| 348 | Solar light |
| 349 | Supply of Elegant look 60 W(>=190lm/W) AIO LED Solar Street lights having extruded alluminium housing, 180Wp or more (subjected to final panel backup calculation with dimming profile of 100% output for 2 hrs, 90% output for 1 hr, 60% output for 1 hr and 50% output for 8 hrs per day. The calculation is to approved by SE,Electrical Circle (R&B) and CE ,Buildings, Odisha, BBSR before final procurement of the product.) Mono Crystalline Panel/Laminates fixed on the top of the luminaire housing, maintenance free 12.8 volts 96 Ah or more (subjected to final battery calculation with dimming profile of 100% output for 2 hrs, 90% output for 1 hr, 60% output for 1 hr and 50% output for 8 hrs per day. The calculation is to approved by SE,Electrical Circle (R&B) and CE ,Buildings, Odisha, BBSR before final procurement of the product.) LiFePO4 battery(BIS certified) , BMS, MPPT charge controller, PIR sensor( when there will be no movement the lumens output will be 30% output).The solar panel and battery should be designed to provide 2 days (24 hrs ) back up . The luminaire is having IP 65 protection for critical components, IK 08 and having lumen output of >=11400 lumens as per LM 79 report third party/central/state govt accredited NABL lab to justify the lumen output & lumen efficacy . Lenses should be provided on the LED chip for better lighting dstribution to avoid glare on human eyes. Both the luminaire and Mono Crystalline Panel must be manufactured in India. The Solar lighting company must submit the third party central/state govt accredited NABL lab reports to justify the lumen efficacy,luminaire output , IK 08 and IP 65 protection.The Luminaire should be supplied along with adjustable type mounting bracket which can be fitted directly on the pole.The Solar lighting manufacturer must submit the declaration letter by mentioning that complete solar light and the solar panel are manufactured in India and warranty certificate on their company's letterhead by mentioning warranty period as 5 years and necessary aftersales Service will be provided through their tollfree base service network located within 100 KM from the project site. The Solar Street light manufacturer should have own NABL accredieted laborotory. The following test reports must be submitted and approved from SE,Electrical Circle (R&B) and CE ,Buildings, Odisha, BBSR for the technical acceptance of the products.1.LM 79 REPORT and LM 80 Report ( from third party/central/state govt accredited NABL lab of AIO solar light) , 2. IK 08 ( from third party/central/state govt accredited NABL lab of AIO solar light ) , 3. IP 65 (Report of third party/central/state govt accredited NABL lab of AIO solar light 4. EN50530 – MPPT Efficiency , 5. IEC61547 , 6. IEC61000-3-2 – EMC , 7. IEC 60598-2-3 ,8. IEC 62109-1, ( The necessary test reports of third party/central/state govt accredited NABL lab from sl no. 4 to sl no.8 must be submitted for any wattage of AIO solar light )Make-(Philips/Panasonict/Wipro/Crompton/Bajaj/Havells/LT ). NB: The cost includes 5 years CMC including repair/ Maintenance/ replacement of the product in case of any defect. |
| 350 | Supply of 8 mtr long hot dip Galvanized Octagonal pole manufactured from HT steel as per BS EN 10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 155 MM A/F of 4 mm thick or more , base plate as per IS 2062 complete with 4 nos. En 8 grade foundation bolts to withstand basic wind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles: Utkarsh/Bajaj/RR Ispat/Vakarangee as per direction of Engg. in Charge. |
| 351 | Installation of pole by making the suitable size foundation by embeding the pole 1 mtr into the ground with necessary civil work and fixing the light on the pole equievalant make ISI marked as approved as per direction of Engg. in Charge. |
| 352 | Installation of 60W AIO LED solar street light on 8 mtr octagonal pole. |
| 353 | ELV-CCTV ,PA SYSTEM |
| 354 | Supply, Installation, Testing & Commissioning of 5MP IP Network TDN Low-Light IR Fixed Lens Dome/Bullet Camera, 1/2.8\\" CMOS or better, 5MP (2592 x 1944) @ 25fps or better, four stream at various resolution & Frame Rates, Min. Illumination required 0.005 lux (color), 0 Lux IR On, 3 IR LEDs, Smart IR with upto 50m(bullet)/40m(dome) IR distance, Auto ICR (Infrared Cut Filter) 130dB True WDR, S/N Ratio 55db, Shutter Speed 1/3 - 1/100,000; Adavance Video Compression technology such as H.265 HEVC/ H.264 / MJPEG , Fixed Lens 2.8mm(Dome)/3.6mm(bullet), Field of View FoV H:96.5°, V:73.8°(dome)/ Field of View FoV H:94.1°, V:71°(bullet), BLC, HLC, WDR, 2D/3DNR, White Balance - Auto/Manual/Day/Night/timing, Minimum Edge Intelligence Video Analytics : Video Motion Detection, Tampering, Loitering, Intrusion, & People Counting, 5 Privacy Mask, 6 Region Of Intreset, Defog, HTTPS, IP Filter, TLS1.2, AES-128/256, SSH/Telnet closed, Stream Encryption, 2TB SD card support, PoE (802.3 af) and 12V DC, IP 66/67 & IK10 Vandal proof with Die Cast Aluminium Housing, Having Operating temp range : –30°C to 60° C. Certifications: ONVIF Profile S/G/T compliant,, CE (EN 50130-4), FCC Part 15, EN 55032 & RoHS (EN63000),NDA,STQC compliant. Make-Honeywell Value series/Pelco/Axis/Bosch |
| 355 | Supply, Installation, Testing & Commissioning of 5MP IP Network TDN Low-Light IR motorized Lens Dome/Bullet Camera, 1/2.8\\" CMOS or better, 5MP (2592 x 1944) @ 25fps or better, four stream at various resolution & Frame Rates, Min. Illumination required 0.005 lux (color), 0 Lux IR On, 3 IR LEDs, Smart IR with upto 70m(bullet)/50m(dome) IR distance, Auto ICR (Infrared Cut Filter) 130dB True WDR, S/N Ratio 55db, Shutter Speed 1/3 - 1/100,000; Adavance Video Compression technology such as H.265 HEVC/ H.264 / MJPEG , Fixed Lens 2.7-13.5mm motorized, Field of View FoV H:100-28.5°, V:73-21.4°, BLC, HLC, WDR, 2D/3DNR, White Balance - Auto/Manual/Day/Night/timing, Minimum Edge Intelligence Video Analytics : Video Motion Detection, Tampering, Loitering, Intrusion, & People Counting, 5 Privacy Mask, 6 Region Of Intreset, Defog, HTTPS, IP Filter, TLS1.2, AES-128/256, SSH/Telnet closed, Stream Encryption, 2TB SD card support, PoE (802.3 af) and 12V DC, IP 66/67 & IK10 Vandal proof with Die Cast Aluminium Housing, Having Operating temp range : –30°C to 60° C. Certifications: ONVIF Profile S/G/T compliant,, CE (EN 50130-4), FCC Part 15, EN 55032 & RoHS (EN63000),NDA,STQC compliant. Make-Honeywell value series/Pelco/Axis/Bosch |
| 356 | Supply , Installation, testing , commissioning of 64 Channel NVR with 8 SATA; 384 Mbps incoming bandwidth, Up to 8 Megapixels Resolution Display and Recording, H.265 video compression technology with real time encoding, Full function CMS (Central monitoring software) supported, Two way audio supported, Dual streaming technology to encode recording stream and network stream separately, Supports remote monitoring on Mobile Client (Android, IOS), TCP / IP, PPPoE, DHCP, DNS, DDNS, UPnP, NTP, SMTP, Time/ Date, Alarm, Motion Detection & Exact Search (accurate to second), Record Snapshot, FTP, Preset Calling, Email notification supported, Manual/ Alarm/ Motion Detection/ Continuous, CE, FCC, RoHS). Make-Honeywell value series/ Pelco/ Axis/ Bosch |
| 357 | Supply, Installation,Testing & Commisioning of Surveliance 10 TB HDDMake:- WD/Segate/Toshiba |
| 358 | SITC of Certified HDMI® Interface Cable, 18 Gbps, 15 m Makes: Honeywell, Extron, Kramer |
| 359 | SITC of 55\\" UHD IPS Commercial Digital Display for Small Size Discussion & Chambers: Brightness (440 nits or higher), Dynamic Contrast Ratio (Dynamic MCI (Hz)):1000000:1), 1000000:1, Static (Panel) Contrast Ratio-1200:1, Response Time (G to G)-8 ms, Refresh Rate.-60 Hz, Life span (hrs)-30,000, Speaker (Sound Output):10W + 10W, Speaker System: 2.0 ch, DVB-T2/C Broadcasting System, Commercial Smart UX, webOS version (webOS 6.0), BIS Certification with 3 years onsite warrenty. Make: LG/Samsung/Sony |
| 360 | SITC of outdoor type double jacketed 4 pair Cat6 23 awg U/UTP LSZH Cable in the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from -20° to +70°C Cable support Conductor Resistance ≤ 9.38 Ω/100m Max., Cable support Delay Skew: < 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ± 15 Ω @100 MHz. and Propagation Delay @250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Systimax, Legrand, Panduit |
| 361 | SITC of Cat6 I/O with Dual Face plate: The Outlet shall meet or exceed requirement as per ANSI/TIA 568C.2,ISO/IEC 11801, & EN50173. The information outlet NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT and return loss should be verified for CAT6 @ 250Mhz & CAT6A @ 500Mhz. The information outlet connector shall be of gold/nickel, thickness of gold > 0.8 μm. The connectors shall be compatible as per IEEE 802.3af standard for POE application. The PVC material of Face plate should complie ABS /UL94-V-O certified. Make: Systimax, Legrand, Panduit |
| 362 | SITC of Rack mount Draw Type Loaded 6 port LIU available in Standard 19” ,Dimensions (mm) : 430 X 220 X 1U , Cold Rolled Steel as Raw Material , Consist of Top Cover and Bottom Panel , Easy to Assemble and Dissemble , Three Types of Input Holes Cable Entry Through Water Proof Cable Clamp , 12 Duplex SC or LC Adapter Interface , Splice 24 Fibers at Most with 1 Tray ,Adaptor, SM, Duplex SC, PC Type ,Pigtail, Support the TIA/EIA Telecommunication Wiring Standards. Compact Design , Telcordia GR-326-Core . Make: Systimax, Legrand, Panduit |
| 363 | SITC of Cat 6, 24-port loaded, 1U Modular Jack Panel Should accommodate Cat6 with Rear Cable Management and Front removable Tooless Information outlet. Should have easy clip management with labels and clear label covers, Made with of Dicast Aluminium Alloy Material and Non Corrosive with Cat6 toolless RJ45 x 24 ports with color code front panel with patch cord locking. Make: Systimax/ Legrand/ Panduit |
| 364 | SITC of Cat6 UTP 23 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50μ’’ Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax/ Legrand/ Panduit(1 mtr length) |
| 365 | SITC of Cat6 UTP 23 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50μ’’ Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax/ Legrand/ Panduit (2 mtr length) |
| 366 | SITC of 1G-LX/LH SFP transceiver module,SMF, 1310nm, 9/125 um Single mode Fiber Type up to 20 KM. Make: Cisco/ Digisol/ Netgear |
| 367 | SITC of 6 core Single mode OS2 Unitube Armoured Optical fiber cable through existing conduit: The Fiber should be OS2 Single Mode Optical Fiber Cable of Size 9/125µm. Outdoor Corrugated Steel tape Central loose tube. ( Standard Approved: ISO 11801 2nd edition/ EN 50173-1:2002 / IEC 60794-1/IEC 60793-2-50 class B1.3 / EN 60793-2-50: class B1.3 / ITU Recommendation G.652.D - the oder ITU designations A, B and C are also fulfilled / OS1/ISO/IEC 24702:2006, cat. OS2; also OS1 requirements are fulfilled/IEEE 802.3 - 2002 incl. 802.3ae ) Jacket. Make: Systimax/ Legrand/ Panduit |
| 368 | SITC of OFC Patch Cor, SM (OS2), Duplex LC-SC, LC-LC PC Type, 3M, LSZH Fiber Optic Single Mode OS2 Patch Cords are offered in LSZH Jackets with Corning Fiber,Insertion Loss : <= 0.2 db, Max 0.3db/MTRJ: Max 0.5db Return Loss : PC>= 45db, UPC>=50db, APC>=60db. Make: Systimax/ Legrand/ Panduit |
| 369 | SITC of 9U/500D outdoor type IP 55 Wall Mount Rack with Accessories: The rack size should be 600W x 500D, Front frame integrated with top, bottom, front and two side panels for better rigidity and strength, Front Glass Door with Lock loaded, Compliance with standards shall be UL 2416., DIN 41494, IEC EN 60529, IEC EN 62262 , IEC EN 60068-2-11 , ISO 9001:2008 including Power Distribution Unit (06/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Lengt), 1 cooling Fan(230V AC - 90 CFM, dB 42), 2nos 1U Metal Cable manager with Plastic cable loops and H/W screw. Make: Valrack/ Rittal/ Legrand |
| 370 | SITC of 24 Port Layer 2 PoE+ Switch having 24 x 10/100/1000 Mbps Ethernet PoE+ ports with 4 x 1/10Gig SFP+ ports ,1 x RJ45 port console port ,Switching Capacity 128 Gbps , Throughput 96 Mpps ,MAC Address 16k , Switch should support IEEE 802.3af (15.4W) & IEEE 802.3at (30W). Total PoE power: 370W or above , Switch should support DHCP server/relay/client, DHCP snooping/option82 , Switch should support Console, Telnet, SSH v1/2, HTTP, HTTPS, SNMP v1/v2/v3, RMON , TFTP, FTP, SFTP, NTP, ZTP, SPAN, RSPAN,Switch should support support ICMPv6, DHCPv6, ACLv6 ,IPV6 Telnet ,Temperature 0°C -50°C ,Power Supply AC: 100-240V. Make: Digisol, Cisco, HP |
| 371 | EV CHARGE STATION |
| 372 | EV CHARGER |
| 373 | SITC of 60 KW, 415 V AC,50 Hz, DC charger (Dual Gun) with DC O/P 200-1000 VDC, 200 A DC A as per IS17017 with 5 years of comperhensive warranty, guarantee, AMC and ARAI certificate.charging mode4:CCS2,Auto charge, IP54 or above, forced air cooled, outdoor type in complete as per the direction of Engineer-in-charge. The price is inclusive of 2 nos.GI earth plate 600mmx600mmx6mm thick ISI marked with G.I.nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required, 25x5 mm GI strip and 50x6 mm GI strip for each plate earthing as per site requirement.Make-TATA Power/Statiq/Verde-mobility/ElectriVa/Panasonic/Siemens/ABB/Schneider |
| 374 | SITC CMS (A cloud- based charging management service with Android/IOS application and CMS portal)For 5 year.Make-TATA Power/Statiq/Verde-mobility/ElectriVa/Panasonic/Siemens/ABB/Schneider |
| 375 | SITC of 160 A outdoor Sub panel with 2mm CRCA having 200A Cu. busbar 1nos 160 A ,4p mccb 25 ka adjustable thermal based release with Ics=100%Icu as Incomer & 200 A Cu. Bus bar as outgoing feeder as required as per direction of Engg.-in -charge. Type 2 40kA 3P+N SPD with 63A 4P MCB,C series,10kA shall be provided in the incomer.Make of MCCB-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider-CVS/ ABB FormulaMake of MCB-LEGRAND-DX3 / Siemens-Betaguard Model/ Schneider-Acti 9/ ABB SB200Make of SPD-Legrand/Siemens/Schneider/ABB/OBO/Dehn |
| 376 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade POLYCAB/HAVELLS/Finolex/kei/RR Kabel/Gloster ISI marked as approved of size 3.5core x 95 sq mm . |
| 377 | Laying of one number of PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm direct in ground including excavation, sand cushing, protective covering and refilling the trench etc. as required. |
| 378 | Supervision and Commissioning of DC Charging Station. |
| 379 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type) with suitable size modular box & cover including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. (For bike charging) |
| 380 | TWO WHEELER CHARGING PANEL |
| 381 | S/I/T&Commissioning of LT OUTDOOR floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.3P+N Type 2 SPD 40 kA with 63A 4P MCB,10kA, Cseries shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed.Provision of cable alley chamber is mandatory.All the feeders shall have ON/OFF/TRIP indication. |
| 382 | In commer-1-01 number of 125A 4P Icu=100%Ics,25Ka MCCB with TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula Busbar-1&2 04 numbers of 200Amps Aluminium busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing) Out going- 10 numbers of 40A 2P MCB10KA,C series ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse. (ii) 01 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication |
| 383 | CASSETTE TYPE SPLIT UNITS |
| 384 | Supply,installation, testing and commissioning of Air Cooled Cassette type Air conditioners complete with Indoor unit(IDU),Out door unit (ODU), R-32/R410A/R-407 Green Refrigerant, wireless Remote, inbuilt drain pump, suitable for 400/230V, 50Hz, 1/3 phase AC supply. the system shall be capable of performing cooling, dehumidification, Air circulation, filtration & ventilation of following capacity with Scroll/ rotary compressor with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB) as specified. The system shall be able to deliver 100% of the rated capacity asper relevant IS Code. The lab testing reports as per IS: 1391shall be submitted from National Accreditation Board for Testing and Calibration Laboratories (NABL) accredited as per International Electro technical Commission (IEC) 17025 standards/ Central Power Research Institute (CPRI)/ Electrical Research and Development Association (ERDA) with Original Equipment Manufacturer (OEM) etc. complete as per IS: 1391 as required. 5 Star Inverter Type- Cooling only |
| 385 | 4.0 TR with 5 Star BEE Rating (LG-ZTNQ48GMLH2/ O General-AUGG48CRAA-B/ Daikin-FCMF140ARV169) |
| 386 | AIR CONDITIONER SPLIT |
| 387 | Supply,installation, testing and commissioning of Air Cooled HI Wall split type Air conditioners complete with Indoor unit (IDU), Out door unit (ODU), i/c R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cut off and50 hz ,1 phase AC Supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll /rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS694 or IS 9968 temperature sensing control IS/ International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per IS :1391 Part II 2023. The system shall be able to operate up to 50 Degree C (out door ambient temperature). The indoor outdoor must be Blue Fin coated. The unit price included with 3mtr Copper piping with insulation, drain Pipe and copper Power cable. The indoor should have 4 way swing . |
| 388 | 1.5 TR with 5 Star BEE Rating (LG-AS-Q20JWZE/ O General-ASGG18CGWA-B/ Daikin-FTKU50XV16) |
| 389 | 2.0 TR with 5 Star BEE Rating (O General-ASGG24CGWA-B/ Daikin-FTKM60XV16) |
| 390 | REFRIGRANT PIPING |
| 391 | Supply,installation of hard/soft ISI marked copper refrigerant piping of size 5/8 inch and 1/4 inch for suction and liquid line with 3 corex4 sqmm FRLS Copper control cable alongwith 25 mm weather proof closed cell nitrile insulation ,complete with fitting of bends and other nesessary material to complete the job. |
| 392 | 1 TR to 3 TR high wall split A.C |
| 393 | Supply & Installation of interconnecting following sizes of refrigerant copper pipe work of following outer diameter, insulated with 25mm thick closed cell electrometric Nitrile rubber tubular insulation between each set of indoor & outdoor units . The pipe dia upto 25 shall be soft seamless & above 25mm dia shall be hard seamless . All piping inside the room shall be properly fixed/supported with suitable size of clamp/ M.S. hanger and all external piping shall run in GI. cable tray etc. as reqd. Make of insulation-K Flex/Armacell/Vidoflex/Eurobatex/Isoline Make of pipe-Rajco/Mandev/Maxflow (for 4 TR CASSETTE ac) |
| 394 | 9.5 mm with 0.8 mm thick |
| 395 | 15.9 mm with 1.00 mm thick |
| 396 | FRAME WORK |
| 397 | Supply,installation & fabrication of MS base frame for outdoor unit and other nesessary material to complete the job. |
| 398 | 1 TR to 3 TR high wall split A.C |
| 399 | DRAIN PIPING |
| 400 | Supply,installation & fabrication of Insulated drain water piping from indoor to nearestdrain point separate to all and other nesessary material to complete the job. |
| 401 | 25mm nom. Dia pipe |
| 402 | Supply and fixing of 4kVA Voltage stabilizer (Make-V-Guard/Microtek |
| 403 | Supply and fixing of 5kVA Voltage stabilizer (Make-V-Guard/Microtek |
| 404 | FIRE SAFETY EQUIPEMENT |
| 405 | Providing and fixing carbon-di-oxide type fire extinguishers consisting of welded M.S cylindrical body, squeeze lever dischange valve fitted with pressure indicating gauge internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS : 2878 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.Make- Safex/Supremex/ Ceasefire/Flameklog .4.5 kg capacity |
| 406 | Providing and fixing ABC type fire extinguishers consisting of welded M.S cylindrical body, squeeze lever dischange valve fitted with pressure indicating gauge internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.Make- Safex/Supremex/ Ceasefire/Flameklog.6 kg capacity |
| 407 | SIGNAGES: SITC of flexyl Photoluminescent based Glow-in-the-dark sheeting with luminious properties enclosed in a weather-proof UV stabilized film with UV screen printing by imported inks pasted over 3 mm Thick Cast Acrylic Sheet with the Protection of 3 mm Thick Cast Acrylic from Front side with stud type mirror screw with lifespan of 5 years, visible upto 4-6 hrs in total darkness for floor indication, fire exit, hydrant, hose reel, fire extinguisher, MCP, fire alarm panel, in case of fire, lift, alarm valve signages |
| 408 | SITC of Illumination Glow light for Exit Indication with Battery Back-up.Make-Prolite/Bajaj |
| 409 | 58.5 KVA DG |
| 410 | Supply, Transportation, erection, testing and commissioning of 3 Phase, 415V, 50Hz, water cooled multi cylinder diesel generator set with alternator of 58.5KVA ( Make -Kirloskar / Jakson/TMTL/Mahindra/Captiva/Sterling) out put contineous rating directly coupled Engine and Alternator with guard and mounted on a common base plate of Robust construction and complete with AMF panel having IP-52 protection, Acoustic Enclosure as per CPCB IV+ norms , sound absorbing material, to restrict sound level up to 75 dB up to 1 mtr distance and as per CPCB IV+ norms etc as per following specifications mentioned below. Warrentee period must be 2 years ALTERNATOR:The alternator of the output rating shall be 3 Phase, 415V, 50Hz, Ac , 0.8 P.F. lagging at 1500 RPM. The alternator is self excited, self regulated, and shall confirm to IS: 13364 of 1992 with regulation of +5% from no load to full load. degree of protections shall be IP21.ENGINE: Diesel Engine start, developing suitable BHP output at 1500 RPM with mechanical / electronic governing so as to enable the alternator to give 58.5KVA continuous output at 0.8 P.F. lagging at NTP conditions. The diesel engine shall be capable of providing 10% O/L for 1 Hr for every 12 Hrs of continuous running at full load. The engine with 1st filling of oil and Diesel etc.01. Exhaust pipe of required size and length with insulation or clading.02. Diesel tank suitable for 8 to 10 Hours running capacity.03. Residential Silencer.04. SMF Batteries with leads as per the Manufacturer standardsAMF PANEL: Cubical, Compartmentalized, AMF Panel Baord with all Power & Control Contractors, Switches, Meters and other accessories, Internal Wiring, connection, inter-connection etc. for Trouble Free smooth function for 58.5 KVA DG Set complete with Battery Charger & leads as required. BASE PLATE: Common Base Plate of required size for mounting of Engine Alternator Set fabricated from MS Channel and vibration damping arrangement with cushy foor mounting including paintng etc. as required. FOUNDATION: Suitable size Cement Concrete (1:2:4) foundation duly plastered and finished with neat coat Cement as required along with smoke exhaust system piping including base frame of structure & lightening protection system. , control cable of 15mtr 2.5sqmm 6core , civil foundation work. (The Manufacturing of DG set shall not in any case be more than six months old from the date of award of work) |
| 411 | LIGHTENING PROTECTION SYSTEM--- Lightning Protection :- Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB |
| 412 | Supply of Roof conductor holder for parapet- PolyamideConductor holder:With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB |
| 413 | Supply of Polyamide roof cable holder for flat roof:DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 414 | Supply of Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Tested as per IEC 62561. (2nos/expansion piece ). Make-OBO/Dehn/ABB |
| 415 | Supply of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305. Tested for Electrical , mechanical and chemical as per IEC 62561. Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 416 | Supply of Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3 Nominal size Ø10/16 mm aluminium rod: 2 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 417 | Supply for Providing of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete and clamp tested upto 100KA lightning current . Make-OBO/Dehn/ABB |
| 418 | Supply for Providing of Stand for Fang Fix system 16 kg made up of frost resistant concrete. Make-OBO/Dehn/ABB |
| 419 | Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer.Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 420 | Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr Height For Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn/ABB |
| 421 | Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 422 | Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 423 | Supply of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 424 | Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn/ABB |
| 425 | Supply of UL Listed maintenance free ,Low carbon coppercoated earth rod of 3 metre electrode having diameter of 17.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 Make-OBO/Dehn/ABB |
| 426 | Supply of universal clamp made of SS to connect rod with flat conductor Make-OBO/Dehn/ABB |
| 427 | Supply of Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO/Dehn/ABB |
| 428 | Supply of The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system Make-OBO/Dehn/ABB |
| 429 | Installation of The above arrangements including all accessories as per Direction of Engg. In charge. |
| 430 | SITC of 5200 ANSI Lumens, 3 LCD system Laser Projector with 16:10 Aspect Ratio, WUXGA (1920X1200 Pixels) Resolution. Contrast Ratio 3,000,00:1, Lens 1.6x manual zoom. With mounting bracket.Make: Panasonic model-PT-VMZ51S , Veiwsonic, Barco |
| 431 | SITC of imported allmost seamless join, screen size 18' X 32', microperforated fabric, completed aluminium frame screen with a velvet covered.Make: Suvira, Elite, Lumina |
| 432 | SITC of loudspeaker which provides a high quality high performance speaker system for behind the screen home theatre systems.The loudspeaker incorporates true point source technology and is a 2-Way passive loudspeaker containing a 1” exit compression driver assembled in a coaxial configuration along with a 12” LF driver providing a conical 90° opening. 12″ (308 mm) Low Frequency Driver and 1.5″ (38 mm) High Frequency Driver. High performance coaxial driver. 90° conical dispersion. High SPL. Smooth frequency response on and off axis. Frequency Response 65Hz to 20kHz. Power Rating 400W AES, 1600W peak. Sensitivity 98dB 1W/1m. Maximum SPL 124dB continuous, 130dB peak @1m. Finish: Black impact resistant structured coating. Make: Pulz,model-CX12SMP, Martin Audio, L-Acoustic |
| 433 | SITC of High power and high sensitivity 2 x 10” (250 mm) woofer. 100° vertical control Only 12” (300 mm) depth for in wall installation.It is designed to be an inwall or onwall subwoofer system where powerful low frequency extension and ease of integration is the prime criteria. Frequency Response 38Hz to 500Hz. Power Rating 500W AES, 2000W peak. Sensitivity 95.5dB @ 1W/1m. Maximum SPL 122dB continuous, 128dB peak @ 1m. Nominal Impedance 4Ω. Dispersion 180° horizontal, 100° vertical @ 400Hz. Transducers 2 x 10” (250 mm) long throw weather resistant woofer. Make: Pulz model- IW210, Martin Audio, L-Acoustic |
| 434 | SITC of 2-Way Cinema Surround Speaker System, designed to reproduce faithfully the wide dynamic range and extended frequency response to meet today’s immersive audio formats. Frequency Response 65Hz to 20kHz. Power Rating 100W AES, 400W peak. Sensitivity 93.5dB @ 1W/1m. Maximum SPL 113.5dB continuous, 119.5dB peak @ 1m. Nominal Impedance 8Ω. Low Frequency Driver 8″ (200 mm) Mid-Bass drive. High Frequency Driver 1” (25 mm) Dome tweeter. Crossover 2.5kHz Passive, low loss air core inductors and MKP capacitors. Finish Black impact resistant structured coating. Connector Push type binding post, cable upto 4 mm diameter.Make: Pulz model-ES8, Martin Audio, L-Acoustic |
| 435 | SITC of a 4 channel power amplifier specially designed for today’s competitive multiplex environments. The robust bipolar outputcircuit combines clean power with superb dynamics and can accurately drive a variety of speaker systems.Frequency response 30Hz - 20kHz, +0.2dB. Total Harmonic Distortion + Noise <0.01% 20Hz - 20kHz @ 8Ω. Inter modulation Distortion <0.03% SMPTE @ 8Ω. Signal to Noise Ratio -94 dBDamping factor >100 @ 8Ω. Cross-talk -90dB. Slew Rate >10V/µs. Input Sensitivity 1.4V (+4dB). Input Impedance 20kΩ, balanced. Voltage Gain 32dB. Bandwidth 100 kHz. Make: Pulz model-UL4500 , Martin Audio, L-Acoustic |
| 436 | SITC of Premium 7.2 Channel AV Receiver Powered by HEOS™ with Dolby Atmos, 100W, 8K and 6 HDMI Inputs,100 Watts per Channel,HEOS Built-in.Make: Dolby,model-Cinema60, Denon, Marantz |
| 437 | SITC of 2 core 4 sqmm speaker Cables. |
| 438 | SITC of 2 core 6 sqmm speaker Cables. |
| 439 | SITC of 20mtr HDMI cable |
| 440 | SITC of required connectors |
| 441 | SITC of 9U AV rack |
| 442 | SITC of Desktop with 27 inch monitor i7 12th generation 16 GB RAM,8 GB NVIDIA Graphics, 1 TB Hardisk, 512 GB SSD in complete as per the direction of Eng-in-charge.Make-Lenovo Think station(P360) / HP(Z1 Tower G9) |
| 443 | SITC of Sorround Speakers along with Ceiling Mounting Brackets: The Speaker should be Coaxial and provide a Dispersion Angle of 90 Degrees Conical and be capable of delivering a combined SPL of 105dB continous pink noise at the RLP at 2/3rd distance with maximum throw distance of 25ft with a frequency response of 65HZ to 20KHZ. The speaker should be composed of Minimum 8\\" Driver, each having power handling of 120 Watts AES, Sensitivity of 93dB @ 1 Watt 1 Metre or higher. The speakers should be course texture. All metal parts should be power coated or stainless steel.Make: Pulz model-CMX8 With bracket, Martin Audio, L-Acoustic |
| 444 | SITC of 6 Channel Power Amplifier Each amplifier should deliver a minimum power of 200 watts per channel @ 8 ohms, and 300 watts per channel @ 4 ohms. The frequency response should be 30Hz to 20kHz. The damping factor is greater than or equal to 100 @ 8 ohms, and the minimum signal-to-noise ratio is -95dB.Make: Pulz model-PZ6300, L-Acoustic, Martin Audio |
| 445 | SITC of Pre-amplifier with Frequency response ,Left & right out - filter @ 40Hz 40Hz to 30KH ,Left & right out - filter @100Hz 100Hz to 30KHz ,SW out 20Hz to 100Hz,Input sensitivity for rated output 2V (+8.6dB) ,Balanced in 270mV ( -9dB). Unbalanced in 150mV ( -14dB),Tone controls Bass ± 10dB @ 100Hz Midrange ± 10dB @ 1KHz ,Treble ± 10dB @ 10KH.Signal to Noise Ratio ref to rated output 2V (+8.6dB) -80dB, Make: Pulz model-XO23, L-Acoustic, Martin Audio |
| 446 | SITC of mixer amplifier with Frequency Response 20~20KHz (+1dB ~ -3dB) at 4ohms, SNR >89dB (with A-Weight) , Speaker output 100V / 70V (USA version) / 4Ω,With built-in Mp3 supports many audio format like Mp3,WMA, WAV, APE, FLAC etc.Make: Byford model-MA80USB Audio, Yamaha, Behringer |
| 447 | SITC 2 core 4 sqmm speaker Cables |
| 448 | SITC of required connectors |
| 449 | SITC of 6U AV rack |
| 450 | BOQ OF INTERNAL & EXTERNAL PH WORKS |
| 451 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge |
| 452 | 20mm dia C - PVC pipe SDR - 11 |
| 453 | 25mm dia C - PVC pipe SDR - 11 |
| 454 | 32mm dia C - PVC pipe SDR - 11 |
| 455 | 40mm dia C - PVC pipe SDR - 11 |
| 456 | Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials including cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. |
| 457 | 15mm dia CP angle stop cock(FLR-ACR-5053N) |
| 458 | 15mm dia CP two in one bib cock (Con-CHR-041KN Jaquar make) |
| 459 | 15 mm dia CP S.B. Bib cock(CON-CHR-037KN) |
| 460 | 15mm dia CP Pillar cock (Con-CHR-011KN Jaquar make) |
| 461 | 20mm dia CP consealed stop cock(Con-CHR-083KN Jaquar make) |
| 462 | 25mm dia brass full way valve (Shakti make) |
| 463 | 32mm dia brass full way valve (Shakti make) |
| 464 | 40mm dia brass full way valve (Shakti make) |
| 465 | 15mm dia CP Health faucet (Con-ALD-MCH-573 Jaquar make) |
| 466 | 15mm CP Extension piece |
| 467 | 125mm CP grating |
| 468 | 15mm size C.P. flange |
| 469 | Supplying all materials , labour, T&P and fixing rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS:12701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 5.40 mtr. lengthx0.25 mtr width KB brickwork in cement mortar (1:6) of 0.46m height in staging and 0.13mtr thick circular protection wall of 0.46mtr height to support the tank,12mm thick cement plaster in cement mortar (1:6) over brick work, RCC slab of size 1.60mX1.60m and 0.10m thick ,RCC beam of 0.25mx0.30m and 3.40m average length in cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips and required steel reinforcement including centering and shuttering,watering,curing ,cost of all materials,conveyance of all materials to worksite , payment of royalty, all taxes etc.all complete as per approved drawing , P.H. specification and direction of Engineer-in-charge |
| 470 | 2000 liters capacity PVC water storage tank roof of 1st floor |
| 471 | supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings including watering, curing, cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per direction of Engineer-in-charge. |
| 472 | Supplying all materials , labour, T&P and cutting holes in RCC floors and roofs upto 19cm thick for passing P.V.C pipes and G.I fittings etc. , and repairing the holes after insertion of pipe etc. with cement concrete (1:2:4) including finishing complete so as to make it leak-proof as per P.H. specification and direction of Engineer-in-charge |
| 473 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages including watering , curing , cost & conveyance of all materials to worksite, payment of royality, taxes etc all complete as per direction of the Engineer-in-charge. |
| 474 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. |
| 475 | 110mm U-PVC SWR Pipe (Supreme /Ashirvad) |
| 476 | 110mm U-PVC ‘P’ Trap(Ori Plast/Finolex/Supreme Make) |
| 477 | 110mm U-PVC door bend(Ori Plast/Finolex/Supreme Make) |
| 478 | 110mm U-PVC Plain bend(Ori Plast/Finolex/Supreme Make) |
| 479 | 110mm U-PVC offset without ear(Ori Plast/Finolex/Supreme Make) |
| 480 | 110mm U-PVC Cowl(Ori Plast/Finolex/Supreme Make) |
| 481 | 110mm U-PVC S/Jn door(Ori Plast/Finolex/Supreme Make) |
| 482 | 110mm U-PVC Plain tee(Ori Plast/Finolex/Supreme Make) |
| 483 | 110mm U-PVC D/Jn door(Ori Plast/Finolex/Supreme Make) |
| 484 | 110mm U-PVC Door tee(Ori Plast/Finolex/Supreme Make) |
| 485 | 110mm U-PVC Socket(Ori Plast/Finolex/Supreme Make) |
| 486 | Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x30mm footrest, fixing 100mm dia HCI 'p' or 's' trap (with/without 50mm dia horn) for water colset squatting pan including jointing the trap with pan in cement mortar (1:1) cutting the floor and mending good the damages , cost & conveyance of all materials to worksite, payment of royality , taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. |
| 487 | 580mm size Orissa pan (Hindware/Parryware/Neycer make) |
| 488 | Supplying all materials, labour T&P and and fixing 12.50 liters/10 liters capacity low level flushing cistern with a pair of cast iron or M.S. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle,unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connceting the inlet pipe with suupply main , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge |
| 489 | 10 ltr. Capacity pvc L.L. cistern with 32mm. Dia CP long flush bend ( Slimline-white-Parryware make ) |
| 490 | Supplying all materials,labour,T&P and fixing Flat back lipped wall (Mini stall urinal -630mmx180mm) urinal of the following sizes including connecting the urinal with 32mm. dia pvc waste pipe 910mm. long by means of white lead mixed with chopped hemp, fixing 32mm. dia CP dome waste, 15mm. dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc. all complete as per specification and direction of the Engineer in charge Half stall urinal |
| 491 | Supplying all materials, labour, T&P and fixing glazed earthenware squatting plate of size 600mmx350mm with integral longitudinal flushing pipe including embedding the plate in 25mm cement mortar (1:8) laid over 150mm cement concrete (1:5:10) using 40mm hard granite metal all complete as per specification and direction of the Engineer in charge |
| 492 | Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet(European type W.C. pan)with integral 'p' or 's' trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing , cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge |
| 493 | One piece commod(Hindware)ELEMENT Cat No.92084. |
| 494 | EWC(Matrix set)No.70002(P-18) |
| 495 | Supplying all materials, labour T&P and fixing wash basins with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered 'Hot' and 'Cold' with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, cost & conveyance of all materials to worksite, payment of taxes etc. all complete as perP.H specification and direction of the Engineer-in-charge |
| 496 | Under Counter basin(560x450)Hindware-No.10095 |
| 497 | Supplying all materials, labour, T&P for fitting & fixing plain edge kitchen/wall sink of all standard sizes with a pair of bracket, C.P. waste, trap & P.V.C. waste pipe & painting brackets including supply of cement concrete & mortar etc. all complete. 24” x 18” x 10” sink |
| 498 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm.thick A.C. sheet or ply wood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of Engineer in charge. |
| 499 | Large Size mirror with Frame (14x0.90x0.75)= |
| 500 | Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge |
| 501 | CP soap holder (Jaquar)ACN-ACR-1131N |
| 502 | Supplying all materials labor T&P & Fitting & fixing CP shower with rim with supply of red lead and yarn nail complete as per direction of Engineer in charge. |
| 503 | ½” x 5” CP Shower (Plaza Deluxe Make) |
| 504 | Supplying all materials , labour, T&P and cutting holes through existing brick or laterite masonry wall for taking U-PVC pipes and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge |
| 505 | Supplying all materials , labour, T&P and cutting of RCC chajja for taking HCI or U-PVC pipe and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge |
| 506 | Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) pure chill 120 PSS UV of size 750 x 570 x 1350mm hight with water storage capacity 120 liter's along with 3 noa of faucets 2 for cold water and 1 for normal water including a flow of 1.5 ltr per munite etc all complete as per approved drawing , specification and direction of the Engineer in charge |
| 507 | Aqua guard pure Chill 120 PSS UV |
| 508 | Ext P.H. |
| 509 | Supplying all materials ,labour ,T&P and constructing Inspection Chamber of inside size 760mmx760mmx460mm with cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , KB brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips, 12mm thick cement plaster (1:3) with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken hard black granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc.all complete as per approved drawing, P.H specification and direction of Engineer-in-charge |
| 510 | Inside size 76cmx76cmx46cm with 18” dia RCC MH cover |
| 511 | Supplying all materials ,labour ,T&P and constructing gully trap chamber of inside size 250mmx250mm with 8cm thick RCC precast cover slab in cement concrete (1:2:4) mix using 12mm size crusher broken HG chips, foundation concrete (1:4:8) using 40mm size crusher broken HG metal on bed and around trap, KB brick work in cement mortar (1:6) in foundation and plinth and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap, 150mmX150mm size CI grating etc.all complete as per drawing, specification and direction of Engineer-in-charge |
| 512 | Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized P.V.C. pipe conforming to IS 4985/2000 of the following out side dia for class- 3 (0.60mpa ) including jointing with supply of approved solvent cement by non-heat application method/as per manufacture's specification, provoding and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per P.H. specification and direction of the Engineer in charge |
| 513 | 100mm dia P.V.C. pipe |
| 514 | 150mm dia P.V.C. pipe |
| 515 | Supplying all materials labor T&P and constructing MH chamber of sizes earth work in excavation in all kinds of soil CC(1:1:8) with black granite chips size 46mm brick work with K.B. brick having crossing strength not less than 75 Kg /CM2 to 90 Kg/CM2s in CM(1:6)12mm C.P(1:8) inside MH chamber over benching with cement slush pointing (1:3)outside the MH chamber providing painting MS or CI step iron RCC(roof of slab with CC(1:2:4)with black granite chips size 12mm bending binding tying the grills placing of the reinforcement providing RCC color of required size refilling the cavity around the MH chamber with excavated earth including channeling the bed of MH etc all complete as per PH specification. |
| 516 | MH size 0.91m x 0.91 m with 0.45 m (18” dia RCC Cover ) |
| 517 | Supplying all materials labour T&P and constructing 1.80m dia x 2.60 m deep soak way pit with dry brick having crossing strength not less than 75Kg/CM2 to 99Kg/CM2 in CM(1:6) for the remaining 0.4572mm height of wall at top CC(1:3)inside and outside inside fill with dry brick khoa size 38mm ,CM thick RCC perforated slab to a height of 1.9012m from bottom covered by means of 50mmthick RCC wall cover in pieces filled with iron plugs including earth work in excavation refilling of cavity around the pit and painting the iron works complete as per PHD design and specification including carriage of all materials to site. |
| 518 | 1 no 50 users RCC septic tank |
| 519 | Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per direction of the Engineer-in-Charge. |
| 520 | 6.80x2.74x1.50= |
| 521 | Extra lifts of 1.50 mtr or part thereof over the initial lift of 1.5 mtr in all kinds of embankments and road works and ordinary earthwork in general. |
| 522 | 6.80x2.74x0.30= |
| 523 | Supplying all materials, labour, T&P and providing shoring and shuttering foundation trenches, pits etc with close wooden planks or sheets shuttering etc all complete as per direction of the Engineer in charge. |
| 524 | 2x(5.80+2.40)x2.00= |
| 525 | Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer in charge. |
| 526 | 6.50x2.37x0.20= |
| 527 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 528 | 6.50x2.37x0.20= |
| 529 | Supplying all materials, labour, T&P and providing 6mm thick cement plaster (1:4) on RCC work including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 530 | Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 531 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 532 | Buffle wall |
| 533 | R.C.C beams,columns,girder and bressmer etc. |
| 534 | Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 535 | Supplying all materials, labour, T&P and providing cement concrete (1:1.5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 536 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 537 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 538 | Supplying all materials, labour, T&P and providing brick work with K.B bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:4) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 539 | Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge. |
| 540 | Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge |
| 541 | 1 no 20 Users Septic tank |
| 542 | Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge. |
| 543 | 3.29mx2.09mx1.50m= |
| 544 | Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge with 1st extra lift of 1.50 m over initial laft. |
| 545 | 3.29mx2.09mx0.63m= |
| 546 | Supplying all materials labor T&P filling sand in foundation and plinth with well watered and rammed etc all complete as per direction of Engineer-in-charge |
| 547 | Supplying all materials, labour, T&P and providing cement concrete ( 1:3:6 ) with 40mm size crusher broken hard black granite metal including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge. |
| 548 | Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge |
| 549 | Supplying all materials, labour, T&P and providing cement concrete (1:1½:3) with 12mm size crusher broken hard black granite chips for RCC works including hoisting, laying, watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as per PWD specification and direction of the Engineer in charge. |
| 550 | Supplying all materials, labour, T&P and providing steel reinforcement of Fe-415 /Fe-500 grade for RCC work including cutting,bending,binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauge,cost of steel, conveyance of all materials to worksite, payment of royalty,all taxes etc all complete as per PWD specification and direction of the Engineer-in-charge. |
| 551 | Supplying all materials, labour, T&P and providing rigid & smooth centering and shuttering for RCC works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as per specification and direction of the Engineer-in-charge |
| 552 | RCC floor, roof slab chhaja up to 4.430 m height |
| 553 | Supplying all materials.labour.T&P and providing brick work in foundation and plinth with KB bricks having curshing strength not less than 75 kg/sqcm with dimensional tolerance+ 8% in cement mortar ( 1:3 ) including watering,curing,cost of all materials,conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer in charge. |
| 554 | Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:3) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. |
| 555 | Supplying all materials, labour, T&P and providing cement punning including watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as per specification and direction of the Engineer-in-charge |
| 556 | Supplying all materials labour T&P and fitting and fixing 12mm dia MS/CI step iron including supply of necessary CC(1:2:4) for fixing etc. complete as per PH specification. |
| 557 | Supplying all materials, labour T&P for providing fitting & fixing 100mm x 100mm SW Tee in wall including filling the recess with cement concrete (1:2:4) with 12mm size HG chips all complete including watering curing conveyance of all materials to work site payment of royalty all complete as per specification and direction of Engineer in charge. |
| 558 | 1 no 30,000ltr R.C.C. Sump (6.00x2.50x3.00) |
| 559 | Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge. |
| 560 | Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge with 1st extra lift of 1.50 m over initial laft. |
| 561 | Supplying all labor T&P & filling foundation and plinth with excavated materials well watered & rammed etc. all complete as per direction of EIC. |
| 562 | Supplying all materials labor T&P filling sand in foundation and plinth with well watered and rammed etc all complete as per direction of Engineer-in-charge |
| 563 | Supplying all materials, labour, T&P and providing cement concrete ( 1:3:6 ) with 40mm size crusher broken hard black granite metal including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge. |
| 564 | Supplying all materials, labour, T&P and providing cement concrete (1:1½:3) with 12mm size crusher broken hard black granite chips for RCC works including hoisting, laying, watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as per PWD specification and direction of the Engineer in charge. |
| 565 | Supplying all materials, labour, T&P and providing steel reinforcement of Fe-415 /Fe-500 grade for RCC work including cutting,bending,binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauge,cost of steel, conveyance of all materials to worksite, payment of royalty,all taxes etc all complete as per PWD specification and direction of the Engineer-in-charge. |
| 566 | Supplying all materials, labour, T&P and providing rigid & smooth centering and shuttering for RCC works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as per specification and direction of the Engineer-in-charge |
| 567 | RCC floor, roof slab chhaja up to 4.430 m height |
| 568 | Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:3) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. |
| 569 | Supplying all materials, labour, T&P and providing cement punning including watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as per specification and direction of the Engineer-in-charge |
| 570 | Supplying and fitting and fixing stainless steel 34 grade in said rail using 5mm dia 2mm thick circular pipe and balustrade 32mmx32mmx2mm at the rate of mtr.Center to center and square pipe 32x32x2mm below including welding with stanless steel elect rod and fixing with necessary accessories etc.complete as per direction of the Engineer-in-charge. |
| 571 | Providing fitting and fixing RCPC cover etc complete as per direction of Engineer-in-charge |
| 572 | 1 no Pump House of size 8'-0''x8'-0'' |
| 573 | Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge. 2.63 x 4 x 0.80 x0.90= |
| 574 | Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge |
| 575 | Supplying all materials, labour, T&P and providing cement concrete (1:1½:3) with 12mm size crusher broken hard black granite chips for RCC works including hoisting, laying, watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as per PWD specification and direction of the Engineer in charge. |
| 576 | Supplying all materials.labour.T&P and providing brick work in foundation and plinth with 23cmx11cmx8cm size KB bricks having curshing strength not less than 75 kg/sqcm with dimensional tolerance+ 8% in cement mortar ( 1:3 ) including watering,curing,cost of all materials,conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer in charge. |
| 577 | Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:6) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. |
| 578 | Supplying all materials, labour, T&P and providing steel reinforcement of Fe-415 /Fe-500 grade for RCC work including cutting,bending,binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauge,cost of steel, conveyance of all materials to worksite, payment of royalty,all taxes etc all complete as per PWD specification and direction of the Engineer-in-charge. |
| 579 | Supplying all materials, labour, T&P and providing rigid & smooth centering and shuttering for RCC works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as per specification and direction of the Engineer-in-charge |
| 580 | RCC floor, roof slab chhaja up to 4.430 m height 2.65 x 2.65 = |
| 581 | Supplying all materials, labour, T&P & providing 2.5cm thick A.S. flooring with cement concrete (1:2:4) 12mm hard broken granite chips including conveyance of all materials, watering curing payment of royalty taxes etc. all complete as per direction of Engineer-in-charge. |
| 582 | Supplying all materials, labour, T&P & providing 2.5cm thick D.P.C. flooring with cement concrete (1:2:4) 12mm hard broken granite chips including conveyance of all materials, watering curing payment of royalty taxes etc. all complete as per direction of Engineer-in-charge. |
| 583 | White washing two coats with approved good stone lime over the interior surface of the walls and celing inculding all labour charges cost and conveyance of all materials, taxes and cost of indigo glue with T & P etc complete in all respect in frist floor and as per direction of the Engineer -in- charge |
| 584 | Supplying fitting, fixing in position angle iron window frame made out of 35mm x 35mm x 5mm, M.S. angle with required nos. of hinges and steel shutter made out of 25mm x 25mm x3mm, M.S. angle fitted with 20 gauge G.P. sheet/ steel plate and welded with tower bolt, handle hold fast & M.S. flat of 19mm x 3mm & welded with entire grill on windows and one coat of red oxide primer and fixing with C.C. (1:3:6) using 12mm size HBG CB Chips and making good to the damages and finishing the exposed surface smooth with watering curing etc. as per direction of the Engineer-in-charge. |
| 585 | RAIN WATER HARVESTING SYSTEM(PIT)(2nos) |
| 586 | Earth work in hard soil or gravelly soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-Charge. |
| 587 | Supplying all materials, labour, T&P and providing cement concrete (1:4:8) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 588 | Supplying all materials, labour, T&P and providing brick work with Fly ash bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:6) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 589 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork with cement punning and bitumen painting over top of wall including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 590 | Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 591 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 592 | R.C.C floor and roof slabs, landings, balconies, projecting sunshades and |
| 593 | Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 594 | In ground floor |
| 595 | Supplying all materials, labour, T&P and providing cement concrete (1:1½:3)with 12mm size hard broken granite chips including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 596 | In ground floorSlab |
| 597 | providing and filling filter media |
| 598 | 40mm Boulder- |
| 599 | 20mm washed gravel-- |
| 600 | Course sand- |
| 601 | Providing fitting & fixing M.S.grill cover over the harvesty pindi |
| 602 | Sinking of tube well(200) for PIT |
| 603 | Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only |
| 604 | Drilling of 200mm dia bore |
| 605 | 00 mtr to 25mtr |
| 606 | Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials. |
| 607 | 200mm dia PVC pipe |
| 608 | cost of 200mm pvc pipe |
| 609 | Cutting slot in casing pipe for recharge of rain water |
| 610 | labour for packing gravel outside the tube well |
| 611 | Cost of washed gravel |
| 612 | Construction of 1no production wells including scientific source finding through consolidated and unconsolidated rock with down the hammer drilling rig or combination rig with PVC pipe and installation of submersible pump set with all acessories |
| 613 | Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only |
| 614 | Drilling of 200mm dia bore |
| 615 | 00 mtr to 30mtr |
| 616 | 30 mtr to 45mtr |
| 617 | Drilling of 150mm dia bore |
| 618 | 45 mtr to 215.00mtr |
| 619 | Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials. |
| 620 | Lowering of 200mm dia P.V.C casing pipes |
| 621 | 00 mtr to 30 mtrs |
| 622 | 30 mtr to 60mtr |
| 623 | Supplying polyvinyl chloride pipes as per ASTM-D-1785-89 having threads in accordance with DIN 2999 part-1/DIN-42225 part-II specification length of pipe (laying length) will be 3 mtrs. The pipes shall be supplied with both external and threaded with free socket. The pipe having external thread at one end i.e female and or belled end. The female end having internal thread is to be belled in order to accept the male end while jointing pipes with a bore threading shall be provided with a greave at the roof of the male thread accomodate flexible PVC/Rubber 'O' ring to make the joint water tight colour of the pipe shall be blue. The name of the manufacture along with batch No class of pipe shall be stranded legibly of each pipe length. |
| 624 | 200mm dia PVC (sch-80) pipe |
| 625 | Supplying all materials, labour, T&P and providing and providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5m below ground level (as per drawing) to plug the bore hole excluding cost of cement all complete as per direction of the Engineer in charge. Minimum one metre of casing pipe to be inserted in the bore into the rock at the bottom to ensure sanitary sealing (excluding cost of cement which will be supplied directly by the department) |
| 626 | Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge |
| 627 | By DTH Rig |
| 628 | Supplying all materials, equipment, labour & conducting reconnaissance survey, integrated Hydrological and Geophysical (Electrical Resistivity Method) survey & selection of potential source for exploration of Ground Water including selection and recommendation of site for drilling wells in selected locations in any part of Orissa under the following Geological formation: |
| 629 | Rocky terrain with boulder formation for 300m depth |
| 630 | AS PER CHIEF ENGINEER, RWS&S. ODISHA BHUBANSWER INDICATIVE RATES VIDE LETTER. NO. PB.340 DT.31.5.2010 AND Lr. No. 7050 DT 05.10.2010 |
| 631 | Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 125mmdia G.I/P.V.C/M.S casing pipes for housting fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), |
| 632 | Drilling of 125mm x 100 mm dia bore |
| 633 | 00 mtr to 30mtr |
| 634 | Drilling of 100 mm dia bore |
| 635 | 38 mtr to above |
| 636 | Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials. |
| 637 | Lowering of 125mm dia P.V.C casing pipes |
| 638 | 00 mtr to 30mtrs |
| 639 | Supplying polyvinyl chloride pipes as per ASTM-D-1785-89 having threads in accordance with DIN 2999 part-1/DIN-42225 part-II specification length of pipe (laying length) will be 3 mtrs. The pipes shall be supplied with both external and threaded with free socket. The pipe having external thread at one end i.e female and or belled end. The female end having internal thread is to be belled in order to accept the male end while jointing pipes with a bore threading shall be provided with a greave at the roof of the male thread accomodate flexible PVC/Rubber 'O' ring to make the joint water tight colour of the pipe shall be blue. The name of the manufacture along with batch No class of pipe shall be stranded legibly of each pipe length. |
| 640 | 125mm dia PVC (sch-80) pipe |
| 641 | Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge |
| 642 | By DTH Rig |
| 643 | Supplying all materials, equipment, labour & conducting reconnaissance survey, integrated Hydrological and Geophysical (Electrical Resistivity Method) survey & selection of potential source for exploration of Ground Water including selection and recommendation of site for drilling wells in selected locations in any part of Orissa under the following Geological formation: |
| 644 | Rocky terrain with boulder formation for 300m depth |
| 645 | Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge (Texmo/Crompton Greaves/Kirloskar make) |
| 646 | 1 H.P. Single phase/ three phase 3 stage head renge of 20 to 35 mtr with discharge capasity 145 to 110 L.P.M With outlet dia 25 mm (keeping 100% standby) |
| 647 | DOL Control panel |
| 648 | 40mm dia steel short piece |
| 649 | Well cap |
| 650 | 50mm size CI bracket |
| 651 | 2.50sqmm flat cable |
| 652 | 20mm dia rigid UPVC pipes |
| 653 | Steel rope with cover |
| 654 | Labour charges for lowering including transportation |
| 655 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor HDPE pipes and pipe fittings conforming to IS: 4984/2000 (10kgf/sqcm) of the following nominal bore with clamps and jointing by Fusion welding method including testing, making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge |
| 656 | 32mm HDPE pipes (Finolex/Supreme make) Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail