| 1 | Carriage, loading-unloading with proper stacking of following material from Central Store /department store to Site distance approx 20 Km. |
| 2 | 33 KV Bus Isolator |
| 3 | Post Insulator |
| 4 | 33 KV Lightening Arrester |
| 5 | 33 KV VCB 800 Amp., 750 MVA |
| 6 | 33 KV CT 400/200/1 Amp. |
| 7 | 33 KV Single T/F Control Pannel with structure. |
| 8 | 600/300/5 AMP, 350 MVA Incoming |
| 9 | 200/100/5 AMP, 350 MVA Outgoing |
| 10 | 33 KV 3x300 SQ MM XLPE |
| 11 | 11 KV 3x300 SQ MM XLPE |
| 12 | 11 KV 3x185 SQ MM XLPE |
| 13 | MS Channel 125x65, 3.2Mtr. Long 1,2,3,4 No Pieces for Top channel. 13.10 Kg/Mtr.+wastage. |
| 14 | MS Angles 75x75x6mm. |
| 15 | Cost of ACSR Panther Conductor |
| 16 | STP 11 Meter Long. |
| 17 | MS Channel 100x50 mm (9.6 Kg/Mtr.). |
| 18 | MS Channel 125x65 sqmm. Top Channel. |
| 19 | 11 KV Disc Fitting Dog/Racoon 70 KN B&S |
| 20 | 11 KV Disc Insulator Dog/Racoon 70 KN B&S |
| 21 | MS Earthing Rod (120x2500) |
| 22 | MS Angle 65x65x6mm for bracing and etc. |
| 23 | 33 KV 3x300 SQ MM XLPE Cable Outdoor |
| 24 | 11 KV 3x300 SQ MM XLPE Cable Outdoor |
| 25 | 11 KV 3x300 SQ MM XLPE Cable Indoor |
| 26 | 11 KV 3x185 SQ MM XLPE Cable Outdoor |
| 27 | 11 KV 3x185 SQ MM XLPE Cable Indoor |
| 28 | Stay Wire 7/8 swg. |
| 29 | 11 KV Bus Coupler. |
| 30 | 24V Battery |
| 31 | 24V Battery Charger. |
| 32 | Dismantling & safe shifting of existing & working 33/11 KV 05 MVA T/F from plinth to suitable storage place after opening jumper and cable connections as per instruction of Site Engineer. |
| 33 | Extemsion and Repairing of Power Transformer Plinth for 10 MVA T/F. |
| 34 | Plinth of Power T/F (5/10 MVA): Construction of plinth of size 3.46 x4.46 Mtr. For 5MVA T/F having 0.4 Mtr. above ground level. The work includes excavation of foundation, base concretion of CC 1:4:8 ratio (cement, fine sand & brick ballast) first class brick work in cement morter of rtio1:4 foundation CC in 1:4:8 ratio(cement, find sand & brick ballast) and RCC work in ratio 1:2:4 (cement, coarse sand and stone grit of 20mm gauge using MS bar of (All Material provide by contractor. |
| 35 | Fabrication, Errection & Grouting of Substation Structure: |
| 36 | Isolator Structure: Fabrication of Isolator Structure 3.5 mtr in height by using MS Channel 125x65 Sq.mm & Angle 75x65 Sq.mm as per Drg. digging of two no. pits of size 1.075x0.9x0.3 mtr. providing Stone Pad at the bottom of the pit and grouting of two legs of the isolator structure in CC(cement coarse sand and stone grit of 20mm gauge) of the ratio 1:4:8 in block of 1.075x0.3 mtr. including all civil material, T&P complete in all respect. The work includes dragging, shifting up to 40 Mtr., raising and erecting the two legs with runner on proper alignment and level and plumb. Both plinths of the isolator structure shall be properly finished with smoothing of edges. |
| 37 | Lightening Arrestor, P.I. & CT Structure : Fabrication of Lightening Arrestor, P.I. & CT Structure 3.5 mtr. in height with using of MS Channel 125x65 Sq.mm. & Angle 75x75x6 as per Drg. digging of two no pits of size 1.075x0.9x0.3 mtr. providing stone pad at the bottom of the pit and grouting of two legs of the Structure in CC(cement coarse sand and stone grit of 20mm gauge) of the ratio 1:4:8 in block of 1.075x0.3 mtr. including all civil material, T&P complete in all respect. The work includes dragging, shifting up to 40 Mtr., raising and erecting the two legs with runner on proper alignment and level and plumb. Both plinths of the structure shall be properly finished with smoothing of edges. |
| 38 | Plinth of VCB : Construction of Plinth of size 2.0 mtrx1.5mtrx0.9mtr. suitable for erection of upper structure of 33KV VCB including grouting of anchor bolts in proper alignment and level. Scope of work includes excavation of foundation base concreting in CC 1:3:6 (cement, find sand & brick ballast) 1st class brick work in cement mortor ratio 1:4:8 (cement, coarse sand and stone grit of 20mm gauge). |
| 39 | Erection, installation and Testing of 33/11KV Power T/F (5/10 KVA) |
| 40 | Erection, installation and Testing of 33/11KV (05/10 MVA) T/F in a levelled position of the plinth. The work includes shifting of T/F to the site & installation within the S/S premises, assembling, fixing and fitting of all accessories and filling of T/F oil to the desired level and ensuring that there is no leakage. All jumpering & connection are included in the scope of work. |
| 41 | Boring Type Earthing : Earthing for power T/F by way of boring and lowering of 40mm dia, 2.9 mm thick GI Pipe B class from ground upto the water level (minimum 60 feet deep) as per standard practice as per RESPO/REC Drg to ensure below 01 ohm resistance with making of earth pit of 300x300 mm & 1 feet deep with Cover. |
| 42 | Neutral Stand : Fabrication and grouting (1:4:8) of MS Channel 100x50 mm in L Shape & in proper size and alignment to provide support for the two separate earthing strips (50x6)mm size for power transformer neutral including supply & fixing of two no. flexible copper bonds for neutral earthing as per Drg. |
| 43 | Cable Stand (Suitable for 11 KV & 33 KV : Fabrication and erection of cable support made of two pieces of MS channel 125x65mm, 3.0 mtr. long joined to each other by means of 5 no. MS Fat 50x6mm pieces of size 150mm long each by welding at equal intervals as per drawing and grouting in block of size 300x300x700mm (1:4:8) complete with one coat of ready mixed primer and two coats of Al. Paint. This includes providing of four no. MS Clamp made of MS Flat holding the cable including nuts & bolts and fixing of XLPE cable. |
| 44 | Installation of Isolators: Assembling and installation of line/ bus isolator on the isolator structure adjusting of opening mechanics in proper alignment so as to ensure smooth operation of the same. In case of line isolator proper operation of earth links shall also be ensured. The work includes fabrication & proper connection with earthmat by G.I. erth strip 50x6mm for proper earthing of as per norms of UPPCL flexing if required. |
| 45 | Installation of P.I. & Lightening Arrestors : Assembling, installation & mounting of 3 No.(1set) L.A. & Post insulator on the L.A & P.I. Structure/complete with making earth connections (separate) and line connections. The work includes of febrication, fixing and earthing work as per norms of UPPCL. |
| 46 | Installation of CT: Installation of 3 No.(1 set) CT on the CT Structure along with CT Junction Box. The work includes fabrication for proper fixing of C.T. If required and proper commissioning & testing in complete respect as per norms of UPPCL. (CT Junction Box to be provided by Contractor). |
| 47 | Installation of VCB: Installation of 33KV VCB complete work including commissioning, testing & earthing. |
| 48 | Installation of Switchgears in Control Room: |
| 49 | Shifting carefully & installation safely 11KV I/C & O/G bus coupler switchgears from outside the switchgear room placing and fixing of switchgear on foundation providing G.I. Bolt & Nuts of proper size in proper position and alignment and checking, complete work with mounting of P.T. on incoming S/G with proper testing & commissioning of switchgears. |
| 50 | Fixing and making Bus Bar connections in between all switchgears after cleaning and tapping with H.T. Tape, empire tape and PVC tape properly, providing and fixing of 6 mm thick Bakelite separators and plugging of all opening & holes with plastic compound complete work as per satisfaction of site incharge. |
| 51 | Shifting carefully and installation of 33KV Single Transformer Control Panel in Control Room including fixing, bolting & grouting of above as per site requirment including commisioning and testing work complete as per norms of UPPCL. |
| 52 | HT Cable Laying : |
| 53 | Laying & dressing of 11KV 3x300 Sq.mm U/G cable Double Ckt. from by excavation of earth in the trench 450mm wide, 900mm deep providing 150mm fine sand cushion below the cable. The cable shall be duly protected by bricks, sand & stone slab and refilling & ramming of the left out soil. Spare cable shall be left and buried in the trench in the shape of rings at both ends. Cable laying work includes unrolling, cutting, making ring and sealing both ends of the cable. (All decentralized/consumable materials to be provided by Contractor Expect Cable) & in case of vipin khand, single Ckt. all other criteria is same as above. |
| 54 | Laying & dressing of 11KV 3x300/3x185 Sq.mm U/G single ckt. if required double ckt cable from 5MVA T/F to 11KV Outgoing Switchgear by excavation of earth in the trench 450mm wide, 900mm deep providing 150mm fine sand cushion below & above the cable. The cable shall be duly protected by bricks, sand & stone slab and refilling & ramming of the left out soil. Spare cable shall be left and buried in the trench in the shape of rings at both ends. Cable laying work includes unrolling, cutting, making ring and sealing both ends of the cable. (All decentralized/consumable materials to be provided by Contractor Expect Cable). |
| 55 | Laying & dressing of 11KV 3X300 Sq. mm /3x185 Sq.mm U/G cable from 11 KV Switchgear in Existing Cable Trench of Switchgear room (All decentralized/consumable materials to be provided by Contractor Expect Cable). |
| 56 | Laying & dressing of 33 KV 3x300 Sq.mm U/G cable Single Ckt. from by excavation of earth in the trench 750mm wide, 1200 mm deep providing 150mm fine sand cushion below the cable. The cable shall be duly protected by bricks, sand & stone slab and refilling & ramming of the left out soil. Spare cable shall be left and buried in the trench in the shape of rings at both ends. Cable laying work includes unrolling, cutting, making ring and sealing both ends of the cable. (All decentralized/consumable materials to be provided by Contractor Expect Cable). |
| 57 | Hoisting of 11KV Cable for 11 KV switchgears & 33/11KV T/F of requried size. |
| 58 | Making vertical/horizontal jumper connections using Panther/Dog Conductor with existing busbar gantry through PG Clamps and connecting all equipments with each other through connecting clamps. The work includes all the jumpes from busbar to T/F (1no. T/F bay) |
| 59 | Construction of Cable trench of size 300x300mm including brick work 1:4 in wall of the trench, brick ballast work in 1:5:10 on foundation plaster 12mm thick with coarse sand 1:4 and surface finishing with cement, providing MS Strip at an interval of 0.5 Mt. and MS Angle (25x25x5mm) running on both the edges of trench. |
| 60 | Construction of welded frame type control cable trench cover 0.5 Mt. long suitable for trench including cost of MS/Tor Bar. |
| 61 | Double Support STP 11 mtr. For Outgoing Feeder |
| 62 | (a) Grouting of stay rods 1800x16 mm including all works of excavation grouting by , cement concrete in size 0.60x0.60x0.3 mtr. with ratio 1:4:8 as per relevant drawing including back filling of earth and proper ramming. (b) Fixing, tightening & nuzzling of stay with the poles and required tension as per RESPO/ RES. drawing. (Stay rod will be provided by contractor). |
| 63 | Earthing of poles as per RESPO norms . (All the materials supplied by contractor) |
| 64 | Supply and laying of following size Good Quality Armoured Copper Control Cable as per norms of UPPCL through underground/cable trench interlinking through proper termination between all equipment such as T/F Control panel/protection panel/Battery and Battery Charger/VCB/CTs junction box with the help of proper size cable gland/lug and ferrules including proper dressing with the help of proper size of cable tie. (All decentralized/consumable materials to be provided by Contractor). |
| 65 | Cable Tray |
| 66 | 2x2.5 Sq.mm |
| 67 | 4x2.5 Sq.mm |
| 68 | Painting of all structures and equipments of All Five Substations with good quality ISI Mark one coat of red oxide primer & two coats of Aluminium Paint.One JOB For One S/S .Total 5 S/S (All materials to be provided by Contractor). |
| 69 | Providing and Fixing of Single Core PVC Cable, 1x240/400/630 sq.mm. & suitable size of Al. lug, nut bolt etc. fixing between Transformer incoming 3x300 Sq.mm XLPE Cable and Transformer 11 KV/LV Side Bushing connector for reducing of tension at LV Side Bushing. (All material supplied by cont.) |
| 70 | Repair and Whole Maintenance of Existing 33 KV VCB |
| 71 | Dismentiling & Extra Civil Works as per site requirement & repair as before. |
| 72 | Fire Wall Between Power T/F (As per Annexure A& Drawing) |
| 73 | Approch road in switchyard bu using Interlocking Tiles Edge Bar in Switch Yard and Leveling of Yard by local soil, fine sand and stone greet size 30 to 40 mm. |
| 74 | Installation of 24 Volt Battery and it charger with connections to existing control circuit complete in all respects. (Exide/Amaron/Luminous Standard Quality.) |
| 75 | Supply of 40 Watt LED Light |
| 76 | Supply and fixing of Rubber mat 8/10mm, 2x4mtr. |
| 77 | Excavation of earth for laying mat |
| 78 | Driving of earth electrode. |
| 79 | Laying of earthmat (M.S.) Bar including cutting, shaping and binding etc) |
| 80 | Preparation of joints, proper making and welding; of main earthmat bar joints and oplying bitumen, bitumen impregnated on joints i.e. End Joints. Cross Joints, Lap pints. |
| 81 | Welding of riser strip with earthmat and structure body. Please Enable Macros to View BoQ information |