| 1 | Demolishing cement concrete manually/by mechanical means i/c disposal of material within 50 m lead as per direction of E/I nominal concrete 1:3:6 or richer mix (i/c equivalent design mix). (DSR-18, I.No.-15.2.1/P-258) |
| 2 | Earth work in excavation by mechanical means (hydraulic excavater)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 Sqm. on plan) i/c disposal of excavated earth, lead up to 50 m and lift up 1.5, disposed earth to be levelled and neatly dressed in all kind of soil. The Contractor has to detect different utilities like sewer line, water supply line, electric cable, telephone cable, gas pipe line etc. using utility detecting machine before start of excavation and shall start excavation only after getting permission of Engineer-in-Charge. (DSR-18, I.No.-2.6.1/P-72) |
| 3 | Extra for every additional lift of 1.5 or part thereof in all kind of soil. (DSR-18, I.No.-2.26/P-77) |
| 4 | 1.50 - 3.00 m |
| 5 | 3.00 - 4.50 m |
| 6 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth consolidating each deposited layer by ramming & watering, lead upto 50 m and lift upto 1.5 m. (DSR-18, I.No.-2.25/P-77) |
| 7 | Centring and shuttering i/c strutting, propping etc. and removal of form for Foundation, footings, bases of columns etc. for mass concrete. (DSR-18, I.No.-5.9.1/P-98) |
| 8 | P/L in position Cement Concrete of specified grade excluding the cost of centering and shuttering, all work up to plinth level in 1:4:8 (1 Cement : 4 C. Sand : 8 graded stone agg. 40 mm n.s.). (DSR-18, I.No.-4.1.8/P-88) |
| 9 | P/L non pressure RCC Socket & Spigot Pipe conferming to IS:458:2003 with latest amendment laying in true alignment & position on craddle i/c with rubber ring (conferming to IS:5382 with latest amendment) testing of laid pipe as per direction of E/I complete in all respect (NSI-2.3.00) |
| 10 | 300 mm dia NP3 class |
| 11 | 400 mm dia NP3 class |
| 12 | Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 Cement : 4 C. Sand), in side cement plaster 12 mm thick with cement mortar 1:3 (1 Cement : 3 C. Sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 Cement : 3 C. Sand : 6 graded stone agg. 40 mm n.s.) and making necessary channel in cement concrete 1:2:4 (1 Cement : 2 C. Sand : 4 graded stone agg. 20 mm n.s.) finished with a floating coat of neat cement all complete as per standard design. 0.91 m deep with S.F.R.C cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to IS:12592, total weight of cover and frame to be not less than 182 Kg., fixed in cement concrete 1:2:4 (1 Cement : 2 C. Sand : 4 graded stone agg. 20mm n.s.) i/c centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) with comman burnt clay FPS (non modular) bricks of class designation 100. (DSR-18, I.No.-19.9.1.1/P-365) |
| 13 | Extra depth for circuler type manhole 0.91 m internal dia (at bottom) beyond 0.91 m to 1.67 m. with comman burnt clay FPS (non modular) bricks of class designation 100. (DSR-18, I.No.-19.10.1/P-365) |
| 14 | Constructing brick masonry circular type manhole 1.22 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 Cement : 4 C. Sand), in side cement plaster 12 mm thick with cement mortar 1:3 (1 Cement : 3 C. Sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 Cement : 3 C. Sand : 6 graded stone agg. 40 mm n.s.) and making necessary channel in cement concrete 1:2:4 (1 Cement : 2 C. Sand : 4 graded stone agg. 20 mm n.s.) finished with a floating coat of neat cement all complete as per standard design. 1.68 m deep with S.F.R.C cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to IS:12592, total weight of cover and frame to be not less than 182 Kg., fixed in cement concrete 1:2:4 (1 Cement : 2 C. Sand : 4 graded stone agg. 20mm n.s.) i/c centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) with comman burnt clay FPS (non modular) bricks of class designation 100. (DSR-18, I.No.-19.11.1/P-365) |
| 15 | Extra depth for circuler type manhole 1.22 m internal dia (at bottom) beyond 1.68 m to 2.29 m. with comman burnt clay FPS (non modular) bricks of class designation 100. (DSR-18, I.No.-19.12.1/P-365) |
| 16 | Constructing brick masonry circular type manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 Cement : 4 C. Sand), in side cement plaster 12 mm thick with cement mortar 1:3 (1 Cement : 3 C. Sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 Cement : 3 C. Sand : 6 graded stone agg. 40 mm n.s.) and making necessary channel in cement concrete 1:2:4 (1 Cement : 2 C. Sand : 4 graded stone agg. 20 mm n.s.) finished with a floating coat of neat cement all complete as per standard design. 2.30 m deep with S.F.R.C cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to IS:12592, total weight of cover and frame to be not less than 182 Kg., fixed in cement concrete 1:2:4 (1 Cement : 2 C. Sand : 4 graded stone agg. 20mm n.s.) i/c centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) with comman burnt clay FPS (non modular) bricks of class designation 100. (DSR-18, I.No.-19.13.1/P-366) |
| 17 | Extra depth for circuler type manhole 1.52 m internal dia (at bottom) beyond 2.30 m. with comman burnt clay FPS (non modular) bricks of class designation 100. (DSR-18, I.No.-19.14.1/P-366) |
| 18 | 12 mm cement plaster of mix 1:4 (1 Cement : 4 C. Sand). (DSR-18, I.No.-13.4.1/P-227) |
| 19 | Extra for plastering on circular work not exceeding 6.0 m in radius in one coat. (DSR-18, I.No.-13.23.1/P-230) |
| 20 | Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23x25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactrue's permanent identification mark to be visible even after fixing i/c fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 Cement : 3 C. Sand : 6 graded stone agg.20 mm n.s.) complete as per design. (DSR-18, I.No.-19.16/P-366) |
| 21 | Excavating trenches of required width for pipes, cables etc. i/c excavation for sockets depth upto 1.50 m i/c getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm. in depth i/c consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within lead of 50 m. The Contractor has to detect different utilities like sewer line, water supply line, electric cable, telephone cable, gas pipe line etc. using utility detecting machine before start of excavation and shall start excavation only after getting permission of Engineer-in-Charge. Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia. (DSR-18, I.No.-2.13.1.2/P-75) |
| 22 | P/L following size of PVC pipes 6 Kg/Cm2 with required PVC Standered special conferming to IS code with latest amendment and lowering the same trenches and laying true to alignment and gradient complete i/c the cost of cutting of pipes for making upto length and making joints i/c cost of socket, plastochem PV-85 PVC solvent cement complete. PVC Pipe must be confermed IS:4985-2000 with latest amendment. Finolex/Kisan/Supreme Make (NSI-1.3) |
| 23 | 200 mm dia 6 Kg/cm2 |
| 24 | 160 mm dia 6 Kg/cm2 |
| 25 | P/F Sluice Valve shall generally conform to IS 14846 with latest amendment, with length over flanged as per PD of IS 14846 corresponding to BS EN-558/ISO 5752 Basic series 3 in CI construction having metal seating (IS 318 Gr. LTB 2). With complete component & material of construction following below:-1 - Body/Door/Dome-Cast Iron IS 210 Gr. FC 2602 - Spindle-Non rising: Stainless Steel AISI 4103 - Body seat/Door face-Gun metal : IS 318 Gr. LTB 2 (rings to be press fitted and riveted: no screws allowed)4 - Rivets-Soft annealed brass5 - Spindle Nut-Gun metal : IS 318 Gr. LTB 26 - Stem Seal-Greased Hemp7 - Fasteners-Carbon steel8 - Flange Drilling - IS 1538 Table 4 & 69 - PN 1.010 - Accessories (400 mm and above)-Ball thrust bearings to be housed above the wet chamber ie. above the gland. Enclosed Spur Gear Box for ease of operation. Air Plug11 - Painting/Coating - Inside & Outside epoxy liquid coated, DFT minimum 250 micron, shade RAL 5005/5015 (BLUE)12 - Hydro-test-(Open Ended only) (Seat : 10/16 Kg/cm2; Body: 15/24 Kg/cm213 - Upto 600mm dia Mannual Operated & above 600mm Gear box (Make-IVC/Kirloskar) (NSI-1.10.00) |
| 26 | 200 mm dia Kirloskar make (NSI-1.10) |
| 27 | 100 mm dia Kirloskar make (NSI-1.10) |
| 28 | Construction brick masonary chamber in brick work in cement mortar 1:4 (1 Cement : 4 C. Sand) for sluice valve with CI surface box 100 mm top dia, 160 mm bottam dia and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 (1 Cement : 2 C. Sand : 4 graded stone agg. 20mm n.s.) necessary excavation, foundation concrete 1:5:10 (1 Cement : 5 F. Sand : 10 graded stone agg. 40 mm n.s.) and inside plastering with cement mortar 1:3 (1 Cement : 3 C. Sand) 12 mm thick finished with a coat of neat cement complete as per standard design with comman burnt clay FPS bricks (non modular) bricks of class designation 100.....90 x 90 x 100 cm. (DSR-18, I.No.-18.34.1/P-339) |
| 29 | P/F M. S. Specials such as Tee, bend, collars, Tapers, Gap pieces, i/c Flange Ends as required, painting, cutting, welding as per site requirment of M.S. Pipes thickness etc. complete in all respect as per direction by the E/I. (NSI-1.7.00) |
| 30 | Hiring of Gas cutting set with Oxegen and LPG running time @ 6 Hrs. (NSI-10.1.06) |
| 31 | Hiring of Welding Set Running time @ 6 Hrs. (NSI-10.1.07) |
| 32 | Hire charges for D.G Set (i/c cost service of operating staff supply of lubricating oil & diesel) 50 KVA D. G. Set (NSI-10.1.03) |
| 33 | P/L Cement Concrete Pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and fineshed with screed board vibrator, vacuum dewatering process and finaly finished by floating, brooming with wire brush etc. complete as per specifications and direction of Engineer-in-charge. (the panel shuttering work shall be paid for separately) (Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable seperately). (DSR-18, I.No.-16.75/P-284) |
| 34 | Brick work with comman burnt clay F.P.S. (non modular) bricks of class designation 100 in foundation and plinth in cement mortar 1:4 (1 Cement : 4 C. Sand). (DSR-18, I.No.-6.1.1/P-108) |
| 35 | Neat cement punning. (DSR-18, I.No.-13.18/P-229) |
| 36 | Cutting road and making good the same i/c supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required of |
| 37 | Water Wound Macadom (DSR-18, I.No.-16.13.2/P-267) |
| 38 | Bituminous Portion (DSR-18, I.No.-16.13.1/P-267) |
| 39 | Disposal of building rubbish/malba/similar unserviceable, dismantled or waste materials by mechanical means, i/c loading, transporting, unloading to approved municipal dumping ground or as approved by E/I, beyond 50 m initial lead, for all leads i/c all lifts involved. (DSR-18, I.No.-15.60/P-263) Please Enable Macros to View BoQ information |