| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: MILITARY ENGINEERING SERVICES (GE (SOUTH) UDHAMPUR) NAME OF WORK : REPAIR AND MAINT OF EARTHING/SOLAR HEATING APPLIANCES, LIGHTNING PROTECTION AND ELECTRIC ENERGY METERS OF VARIOUS CENTRAL INSTITUTE AND BLDGS UNDER GE (SOUTH) UDHAMPUR Contract No: CA NO : GE/S(U)-61/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words |
| 2 | Supply and fixing Air terminations Single pointed aluminium rod 12mm dia and 300mm long with necessary fixing arrangements on roof including taking down of old rusted all as directed. |
| 3 | Supply and fixing Air terminations Single pointed copper rod 12mm dia and 300mm long with necessary fixing arrangements on roof including taking down of old rusted all as directed. |
| 4 | Supply and fixing test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25mm, drilled and screwed including 3 nos 8mm dia 25 mm hexogonal head screw including taking down old rusted as specified and as directed. |
| 5 | Supply and fixing rectangular PVC insulators for copper/aluminium/GI strip complete all as specified and directed. |
| 6 | Supply and fixing solar water heater panel 100/200 LPD (Evacuated Tube Collector)servicing, cleaning, brazing, cutting, opening of glass etc with replacement of end caps & rubber cover complete all as specifed and directed by Engr-in-charge. |
| 7 | Supply and fixing Heating element capacity 2/3 KW for Solar water heater 1000/500 LPD all as specified and as directed. |
| 8 | Cleaning, servicing and maintenance of Solar Water Heater System of capacity as installed, comprising draining out water from system, dismantling and cleaning of storage tank internally to remove scale, sludge and sediment deposits, cleaning/descaling of solar collector tubes/panels, headers, pipelines and fittings using approved descaling chemicals, checking and cleaning of NRV, air vent, valves and strainers, replacement of minor consumables such as rubber washers, Teflon tape etc., re-fixing and re-commissioning complete system, testing for proper circulation, leakage and heating efficiency, including all labour, tools, tackles, staging/scaffolding, safety precautions and transportation complete all as specified and directed by Engineer-in-Charge. |
| 9 | Supply and fixing solar flat plate collector complete all as specified and directed by Engr-in-charge. Make : Recold/Inter solar pvt Ltd |
| 10 | S&F vent pipe using medium grade GI tubing 20mm dia fixed to wall/ceiling upto level not less than 15cm from OH tank top level including necessary fittings, fixtures, clamps, etc all as specified and as directed. |
| 11 | S&F medium grade GI tubing 15 mm dia fixed to wall/ceiling including necessary fittings, fixtures, clamps, etc all as specified and as directed. |
| 12 | supply and fixing of stop valve cast alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed of size 20 mm all as specified and as directed. |
| 13 | Supply and fixing of stop valve cast alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed of size 25 mm all as specified and as directed. |
| 14 | Supply and fixing solar water heater tank capacity 1000/500 LPD (Innet tank material - stainless steel 304,inner tank thickness 0.5mm, Insulation thickness 45mm, Insulation material - Polyurethene foam (PUF), end cap thickness 0.4mm & Pipe material - stainless steel 304 & pipe size 3/4\\") complete all as specified and directed by Engr-in-charge. |
| 15 | Supply and fixing solar water heater tank capacity 350/300 LPD (Innet tank material - stainless steel 304,inner tank thickness 0.5mm, Insulation thickness 45mm, Insulation material - Polyurethene foam (PUF), end cap thickness 0.4mm & Pipe material - stainless steel 304 & pipe size 3/4\\") complete all as specified and directed by Engr-in-charge. Make - Inter Solar Pvt Ltd |
| 16 | Supply and fix GI tubing medium grade of 25 mm bore complete all as specified and directed by Engr-in-charge. |
| 17 | S&F Union of size 15/20mm , cast copper alloy with crutch , screwed down, screwed for iron pipe or for brass errule and fixed complete all as specified and directed by Engr-in-charge. |
| 18 | S&F Bib taps size 20mm , cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass errule and fixed complete all as specified and directed by Engr-in-charge. |
| 19 | S&F Float valves size 20mm,cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engr-in-charge. |
| 20 | S&F Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe 20mm (Minimum weight 20mm-210gms) and fixed complete all as specified and directed by Engr-in-charge. |
| 21 | S&F flexible Rubber hose pipe of suitable size for hot water , of suitable length (set of two) for inlet/outlet connections of solar water tank with all accessories (like clamps,screws etc.) complete all as specified and directed by Engr-in-charge.All the joints shall be made with welding or (nuts & bolts) to get proper conductivity. |
| 22 | Supply and fix aluminium Strip 25 x 3.15mm and fixing screws from aluminium air termination rod to test point terminal as down conductor and roof conductor including taking down of old rusted all as directed. Note:- All the joints shall be made with welding or (nuts & bolts) to get proper conductivity. |
| 23 | Supply and fix Copper Strip 20 x 3.15mm and fixing with screws as continuous lead from Copper air termination rod to test point ternimal as down conductor, roof conductor and continuous earth lead to test point terminal including taking down of old rusted all as directed. Note:- All the jonts shall be made with copper brazing to get proper conductivity. |
| 24 | Fixing only old aluminium/ copper strip of any size on insulator including straightening to old strip etc complete all as specified and directed.All the joints shall be made with welding or (nuts & bolts) to get proper conductivity. |
| 25 | Supply & fixing of Booster pressure pump of capacity 0.5 HP to 1 HP pumpset with its necessary fixing items such as GI pipe of suitable size ,Unions,T , Elbow etc, complete all as specifed and directed by Engr-in-Charge |
| 26 | Supply & fixing of relay switch for booster pressure pump of capacity 0.5 HP to 1 HP pumpset complete all as specifed and directed by Engr-in-Charge. |
| 27 | M&L for Earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6.00mm thick burried directly in ground (earth pit not less than 2.25 meter deep below normal ground level with top edge of earth plate not less than 1.5 m below the normal ground level) connected to galvanised iron strip 25 x 4mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel as shown in elelctrical plalte No 3 including charcoal dust, commen salt, 20mm bore GI medium grade watering pipe, 40mm dia GI light grade protection pipe with funel and wire mesh, PCC Pit in 1:2:4 type B 1 using 20mm graded stone aggregate with angle iron 40x40x5mm frame, RCC pit cover of suitable size complete all as specified and directed by engineer encharge and testing for required value complete. Note :- (i) Item include the cost of earth lead and GI protection pipe upto 7.5 mtr length. (ii) On completion of Earthing Contractor should check Earthing Results and submit the Test Report to Engr-in-charge. If desired results are not obtained then Earthing shall be redone by the contractor at his own cost. |
| 28 | M & L for Earthing complete with galvanised steel earth plate electrode of size 600x600x6.00 thick as earth electrode burried directly in ground earth plate not less than 2.25m deep below normal groung level with top edge of earth plate not less than 1.5 m below ground level connected to and including galvnised steel earth lead wire 4mm dia as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed inculding providing earth wire protection pipe GI light grade 15mm dia from earth plate to main switch board / panel , watering GI pipe medium grade 20mm dia with mesh and funnel at top , earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of characoal dust and salt all around the earth plate , earth work in any type of soil, remaning surplus excavated material all as required at site and specified in EP no 3 of SSR part I 2009 or directed by Engineer-in-Charge.Note :- (i) Item include the cost of earth lead and GI protection pipe upto 7.5 mtr length. (ii) On completion of Earthing Contractor should check Earthing Results and submit the Test Report to Engr-in-charge. If desired results are not obtained then Earthing shall be redone by the contractor at his own cost. |
| 29 | M&L for Earthing complete with Copper earth plate electrode 600mm x 600mm x 3.15mm thick burried directly in ground (earth pit not less than 2.25 meter deep below normal ground level with top edge of earth plate not less than 1.5 m below the normal ground level) connected with and including to copper strip as earth wire 20 x 3 mm dia by means of bolts, nuts, check nuts and washers of brass all as shown in elelctrical plate No 3 including charcoal dust, common salt, 20mm bore GI medium grade watering pipe, 40mm dia GI light grade protection pipe with funnel and wire mesh, PCC Pit in 1:2:4 type B 1 using 20mm graded stone aggregate with angle iron 40x40x5mm frame, RCC pit cover of suitable size complete all as specified and directed by engineer encharge and testing for required value complete. Note :- (i) Item include the cost of earth lead and GI protection pipe upto 7.5 mtr length. (ii) On completion of Earthing Contractor should check Earthing Results and submit the Test Report to Engr-in-charge. If desired results are not obtained then Earthing shall be redone by the contractor at his own cost. |
| 30 | M & L for Chemical earthing system complete with 03 (One) Nos. UL 467 Approved copper bonded earth rods, Each of 17 mm dia. 3000mm long electrode buried in a bore hole of 100 mm dia. Vertically to a depth not less than 3 Mtr deep below ground level with top edge earth electrode at a depth not less than 300 mm below normal ground level. All Three Earth pit must be in a distance of 2.5Mtr and connected to each other by 25mmX2mm Copper Strip to make Ring Earth. Provision of 01 (One) Nos. of copper bus bar of size 100mmX25mmX5mm for connection with copper earth lead strip 25mmX2mm and further connected to test point terminal of size 200mmX50mmX6mm made of copper as directed, including 30 Kg (Minimum)NABL Lab Certified back fill chemical compound for filling in each bore holes with soil mixed, so as to achieve earth resistance below 1 Ohms. Excavation of PCC chamber in PCC (1:3:6) type complete with Pit cover of 300mmX300mm made of cast iron,complete all as specified and directed by engineer encharge and testing for required value complete.NOTE:On completion of Earthing Contractor should check Earthing Results and submit the Test Report to Engr-in-charge. If desired results are not obtained then Earthing shall be redone by the contractor at his own cost. |
| 31 | M&L for Welding of solar water storage tank and fixing in its original position all as specified and directed by Engr-in-charge. |
| 32 | M&L for rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part - I of capacity 250/300 Ltrs. |
| 33 | M&L for rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part - I of capacity 500 Ltrs. |
| 34 | M&L for rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part - I of capacity 1000 Ltrs. |
| 35 | Supply and fix single phase prepaid/electronic meters temper proof LCD display with polycarbonate cover 230 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH |
| 36 | Supply and fix three phase prepaid/electronic meters temper proof LCD display with polycarbonate cover 415 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH |
| 37 | Supply, fixing and testing of Meter Box Panel made out of 2.5 mm thick MS sheet of size not less than 800*800*150 mm duly painted powder coating with two coats of synthetic enamel paint over a coat of red oxide primer suitable for fixing of 4 x single phase meter in 2 compartment , wall mounted/semi grouted in wall with locking arrangement and provision of tapping for incoming and outgoing electric connections with suitable size of lugs,glands complete all as specified and directed comprising of the following(i) MCCB four pole 415 volts AC 50 Hz, 63 amps rating breaking capacity 10 KA fixed magnetic and adjustable thermal release -01 No. (Make : Havells)(ii) MCB SPN 230 volts AC 50 Hz, 32-40 amps rating breaking capacity 10 KA fixed magnetic and adjustable thermal release - 04 No. (Make : Havells)(iii) fixing and connection of energy meter - 04 nos to 06 nos(v) Earthing terminals - 02 Nos(vi) MCB SP 6-32A 10 KA C series - 01 Nos(vii) Glass infront of each meter compartment for easy view of meter reading without opening door . Note : (i) Contractor shall submit drawing of Meter panel box & after approval of GE procurement will be done. (ii)Cost of labour charges for grouting of meter cabinet in to the wall,Cutting wall and making same the wall patchs making good using putty, white wash and distamper included in quoted rates.The surface should be made smooth using putty and should match exactly with the existing wall finish complete all as specified and as directed. Total in Figures 0.0 0.0 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |