| 1 | Taking down carefully street light/flood light fittings of any make and capacity, opening for examination & for replacement unservicable spare part and refixing the same in position after necessary replacement of drivers and minor spare parts at the same/other location,including any UG cable fault it will be rectified or replaced accordingly and necessary T&P like ladder/Boom Vehicle,tools etc as required for taking down & refixing of street light/flood light complete. Note :- Rate quoted by the tender is not inclusive of supply of drivers. The supply only of drivers where repaired shall be measured and paid separately under respective item No. 2 here-in after. |
| 2 | Supply only LED driver for Street light/flood light fitting of following capacity :- |
| 3 | LED driver for light fitting of capacity 200-250 watt. |
| 4 | LED driver for light fitting of capacity 120-170 watt. |
| 5 | LED driver for light fitting of capacity 90-110 watt. |
| 6 | LED driver for light fitting of capacity 70-80 watt. |
| 7 | LED driver for light fitting of capacity 45-60 watt. |
| 8 | S&F in replacement of LED Street Light fitting 120 Watt, including inbuilt surge protection devices 2KV and having system efficiency not less than 100 lumen / watt, IP65/66 protection, maintenance free isolated Electronic driver circuits, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting complete all as directed . |
| 9 | S&F in replacement of LED Street Light fitting 90 Watt, including inbuilt surge protection devices 2KV and having system efficiency not less than 100 lumen / watt, IP65/66 protection, maintenance free isolated Electronic driver circuits, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting complete all as directed . |
| 10 | S&F in replacement of LED Street Light fitting 70 Watt, including inbuilt surge protection devices 2KV and having system efficiency not less than 100 lumen / watt, IP65/66 protection, maintenance free isolated Electronic driver circuits, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting complete all as directed . |
| 11 | S&F in replacement of LED Flood Light fitting 120 Watt, including inbuilt surge protection devices 2KV and having system efficiency not less than 100 lumen / watt, IP65/66 protection, maintenance free isolated Electronic driver circuits, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting complete all as directed . |
| 12 | S&F in replacement of LED Flood Light fitting 200 Watt, including inbuilt surge protection devices 2KV and having system efficiency not less than 100 lumen / watt, IP65/66 protection, maintenance free isolated Electronic driver circuits, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting complete all as directed . |
| 13 | S&F in replacement of LED Flood Light fitting 240 Watt, including inbuilt surge protection devices 2KV and having system efficiency not less than 100 lumen / watt, IP65/66 protection, maintenance free isolated Electronic driver circuits, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting complete all as directed . |
| 14 | Disconnecting & Taking out LT underground cable from trenches etc, aluminium conductor of size 10 sqmm 2 /4 core including cable cover all as specified and directed.Note- Servicable Cable cover shall be sorted out for reused. |
| 15 | Disconnecting & Taking out LT underground cable from trenches etc, aluminium conductor of size 16 sqmm 4 core including cable cover all as specified and directed.Note- Servicable Cable cover shall be sorted out for reused. |
| 16 | Disconnecting & Taking out LT underground cable from trenches etc, aluminium conductor of size 25 sqmm 3.5 core including cable cover all as specified and directed.Note- Servicable Cable cover shall be sorted out for reused. |
| 17 | Laying only XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 10 Sqmm 2/4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete. |
| 18 | Laying only XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 16 Sqmm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete. |
| 19 | Laying only XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 25 Sqmm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete. |
| 20 | Supply & laying XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable, with aluminium conductor 1100 volt grade of size 10 Sqmm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed |
| 21 | Supply & laying XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable, with aluminium conductor 1100 volt grade of size 16 Sqmm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed |
| 22 | Supply & laying XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable, with aluminium conductor 1100 volt grade of size 25 Sqmm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed |
| 23 | Supply, jointing connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 10/16/25 Sqmm suitable for 2/3.5/ 4 core all as specified and as directed by Engineer-In-Charge. |
| 24 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft / loose soil. |
| 25 | Returning filling in including spreading leveling, watering and well ramming in layers not exc 25 cm thick using excavated soil all as directed |
| 26 | Removing excavated soil to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5m above the starting point. |
| 27 | M&L for providing dry river sand as in sand cushioning to under ground PVC cable including punning down of sand in layer all as specified and directed.(Note: Punned thickness of sand 18 cm shall be considered for payment ) |
| 28 | Laying only PCC cable cover for LT UG cable, of any description retrieved from item No.17 to 22 all as specified and directed. |
| 29 | Supply & laying ISI marked & conforming to IS - 5820 - 1970 unreinforced precast concrete cable cover Class LV , Type I, flat size 250 mm X 150 mm X 40 mm in trenches as protection to LT UG cable all as specified and directed. |
| 30 | S&F in replacement Tubes 40 mm bore, 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors |
| 31 | S&F in replacement Tubes 50 mm bore, 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors |
| 32 | S&F in replacement of LED Aviation obstruction light fitting die cast aluminium alloy housing, heat resistant, clear thick glass and accessories with LED lamp & driver, fixed in position & connecting complete |
| 33 | S&F in replacement of 4 Pole 75/80 Amp power contactor, AC 3 rating, fixed in existing panel & connecting complete all as specified & directed. |
| 34 | S&F in replacement of 4 Pole 32 to 40 Amp power contactor, AC 3 rating, fixed in existing panel & connecting complete all as specified & directed |
| 35 | S&F in replacement Power saver and user friendly analog clock timer to set street light ON/OFF timing complete. |
| 36 | Material & Labour in replacement for service wiring with 2 core multistranded copper conductor cable, of size 1.5 Sqmm each, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through including PVC conduit and including one run single core multistranded copper conductor cable, of size 1.5 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete. |
| 37 | S&F in replacement of 20 mm bore UPVC pipe medium grade inclusive of fitting etc fixed on pole / wall with mild steel clamps made out of MS Flat 25 x 6mm including, nuts, bolts at the interval of 1metre complete including two coat of synthetic enamel paint over a coat of red oxide primer complete. |
| 38 | S&F in replacement of Sheet moulding compound (SMC) junction box of size 350 mm x 200 mm x 150mm, comprising of connector/terimanl one set of three phase each and one neutral and one No MCB SP, 06 Amps \\"C\\" type, fixed on pole with mild steel clamps, nuts and bolts complete. Make:-Sintex/Legrand/Siemens/EPP composite Pvt Ltd./National |
| 39 | M&L preparation of old painted surfaces of RCC/Steel street light pole 9 meter long above coping including cross arm etc and applying one coat of weather proof exterior emulsion paint as per the existing colour or as directed by Engineer-in-Charge on RCC/Steel pole and applying one coat of synthetic enamel paint for service brackets and MS clamps of light fittings and numbering of poles in white paint over the black base complete all as specified and directed. |
| 40 | Supplying and fixing in replacement 1100 volts grade heavy duty cable PVC insulated aluminium conductor twin core 6 sqmm,weather proof,flat or circular served with inner sheathing of PVC tape and overall PVC sheathed in service connections all as specified and directed. |
| 41 | Supplying and fixing in replacement 1100 volts grade heavy duty cable PVC insulated aluminium conductor twin core 10 sqmm,weather proof,flat or circular served with inner sheathing of PVC tape and overall PVC sheathed in service connections all as specified and directed. |
| 42 | Supply and erect in replacement Prestressed concrete pole, 9.0 metres long, 102mm x 172mm at top and 102mm x 279mm at bottom, class 10 Note:- (a) Rate quated is inclusive of following(i) Excavation&Earthwork ,Returning filling and Removal of soil (ii) PCC (1:4:8) type D2 (using 40 mm aggregrate) in base & foundations as per specification (iii) Coping (1:2:4) type b1 as per specification.(iv) PCC (1:3:6) type C2 as per specification.(v) Painting of RCC street pole 9mtr long above coping including cross arm etc applying one coat of weather proof exterior emulsion paint as per the existing colour or as directed by Engineer-in-Charge on RCC pole and applying one coat of synthetic enamel paint for service brackets and MS clamps of light fittings including painting with synthetic enamel paint up to 1.2m from bottom in alternate layers of tri-colour of black,yellow& white and numbering of poles in white paint over the black base . |
| 43 | Supply and fix in replacement MCBs single pole & neutral , 20 to 32 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete including connecting. |
| 44 | Supply and fix in replacement MCBs single pole , 6 to 32 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete including connecting. |
| 45 | Supply and fix in replacement MCBs triple pole & neutral ,40- 63 Amps, 415 volts with ‘C’ curve, fixed in sheet metal board complete including connecting. |
| 46 | M&L for Repairing of 1 to 1.5 HP capacity electric motor of high mast, AC 3 phase, by dismantling the motor cutting and taking out the old winding wires, cleaning the slots, rewinding the motor with appropriate size of super insulated copper conductor winding wire of same gauge, and varnishing complete including replacing the worn out bearing, reassembling the motor and fixing in same position and testing complete all as specified as directed by Engineer in Charge. |
| 47 | Supply and fix in repairs PVC insulated and sheathed trailing cable copper conductor cable of size 2.5 Sqmm 5 core, EPR PCP round cable 1100 volt grade. |
| 48 | M&L for Servicing of complete high mast of any make, model, cap, height by greasing and oiling of wire rope, winch, motor , making proper connection of light fittings in lantern carriage, cleaning & making proper connection of High mast panel including taking down high mast structure for repairing of unserviceable light, reconnecting disturbed wire, realignment of High mast carriage etc all as per specified and directed. |
| 49 | S&F in replacement of mounting bracket for street light fittings made out of GI pipe light grade 40 mm dia upto 1.5 m length bent to shape incl fixing arrangement with neccassary clamps, bolts, nuts, washers etc . |
| 50 | M&L for cleaning of vegetation/shrubs on pole from bottom to top and upto 2m surrounding the pole including cutting/prunning of tree banches all as specified abd directed. |
| 51 | M&L for cutting of PCC/hard standing /WBM road not exceeding 20cm in width not exceeding 30cm in depth for passing of LT cable and making good of disturbed surface to match with the existing surface by using old and new material i.e bitumen/PCC (1:3:6) type C-1 complete all as specified and directed. |
| 52 | M&L for preparation of old painted surfaces of high mastt ladder type from bottom to top including mounting arrangement at top including cross arm etc and applying two coat of synthetic enamel paint or as directed by Engineer-in-Charge complete all as specified as directed by Engineer in Charge. |
| 53 | Supply and fix in replacement of LED Bollard garden light fitting 10 watt height 3 feet ,IP 65/IK 10 protection, with base plate and necessary foundation and connected electric and PCC works complete. |
| 54 | Supply and fix in replacement of LED Post-Top lantern 18 watt, energy saving, environmental friendly, long life aesthtically designed with symmentrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source ,suitable for pole size and making arrangements ,pcc work , electric connections complete. |
| 55 | M&L for day to day complain of checking of time panel, Pole box, MCB,loose wire connection of any type of fault and rectified the same and including cleaning,refixing and alignment of hanging of existing SMC box of any size with necessary fixing arrangment of nut/bolts ,clamps,saddle etc complete as per directed by Engg-in -Charge.Note- Any types of item required for reparing/replacement shall be measured separatly under respective items. Note for Item No 1 to 52:-(a)-One electrician and one helper should be available for attending day to day complaints on all days including/Sunday and holiday and rectified with in 24/48 hours, failing which an amount of Rs 200/-per hour will be recovered as penal recovery from any payment due to the contractor after expiry of 48 hours.) (b) Indls should be in possession of all required tools for rectification of complaints . (c) Labour charges and cost of reqired tools and plant and safety PPE is deemed to be included in the rate above quoted. Please Enable Macros to View BoQ information |