| 1 | Excavation in trenches, n.exc 1.5M wide and not exceeding 1.5M depth for foundation etc or for shaft, wells, cesspits, manhole, pier holes etc n.exc 10 Sqm on plan and n.exc 1.5M in depth and getting out in soft/hard soil complete all as specified. |
| 2 | Excavation in trenches, n.exc 1.5M wide but depth exceeding 1.5M and n.exc 3.00M for foundation etc or for shaft, wells, cesspits, manhole, pier holes etc n.exc 10 Sqm on plan and n.exc 3.00M in depth and getting out in soft/hard soil complete all as specified and directed. |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm complete all as specified and directed by Engineer-in-Charge. |
| 4 | Removing excavated material to a distance exc 50M but n.exc 150M and depositing where directed at a level n.exc 1.5M above the starting point complete all as specified and as directed. |
| 5 | Demolition & breaking up drain pipes (salt glazed stone ware, AC or reinforced concrete) of internal dia of pipe 150mm set in cement mortar including bed concrete and removal of demolished materail out of MoD land complete all as specified and as directed. |
| 6 | Demolition & breaking up drain pipes (salt glazed stone ware, AC or reinforced concrete) of internal dia of pipe 200mm set in cement mortar including bed concrete and removal of demolished materail out of MoD land complete all as specified and as directed. |
| 7 | Supplying and laying 150mm bore Reinforced Cement Concrete pipes, class NP3, laid and jointed complete with collars complete all as specified and as directed. |
| 8 | Supplying and laying 200mm bore Reinforced Cement Concrete pipes, class NP3, laid and jointed complete with collars complete all as specified and as directed. |
| 9 | M&L for PCC (1:3:6), type C-2, using 40mm graded stone aggregate as in concrete bed to drain pipes of 150mm bore including packing under and haunching against the sides of pipes, after they are laid and tested complete all as specified and as directed. |
| 10 | M&L for PCC (1:3:6), type C-2, using 40mm graded stone aggregate as in concrete bed to drain pipes of 200mm bore including packing under and haunching against the sides of pipes, after they are laid and tested complete all as specified and as directed. |
| 11 | Cutting into existing manholes for connecting new drains of dia 150 mm, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B-l smooth finished, and reforming benching as required complete all as specified and as directed. |
| 12 | Cutting into existing manholes for connecting new drains of dia 200 mm, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and as directed. |
| 13 | M&L RCC in lintels upto 1.5 m clear span, cills, steps; seismic & other similar bands, plinth courses, string courses, lacing courses, parapets and railings and pillars upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, as directed type B1 (1:2:4) using 20 mm graded aggregate including necessary use and waste of form work complete all as specified and as directed. |
| 14 | Extra for forming for finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms moulds mitred stopped etc complete all as specified and as directed. |
| 15 | M&L for plain cement concrete (1:3:6) type C-2, using 40mm graded stone aggregate as in foundation and bed concretes, or in channel and drain also etc complete all as specified and as directed. |
| 16 | M&L for removal of blokage of soil/waste pipes WC, WHB, Bottle Trap, Floor Trap etc running on external wall of buildings complete all as specified and as directed. |
| 17 | M&L for removal/ cleaning of blokage in sewage lines between manholes of various sizes by any means by using roding etc complete complete all as specified and as directed. |
| 18 | Cleaning of manhole upto 1.50 m depth and removal of sludge silt/ liquid/ mud/ sand/ water etc in foul position and removing the same from site to outside the MoD land complete all as specified and as directed. |
| 19 | Description all as per ser item No 18.00 here-in-before but depth exceeding 1.5 m and not exceeding 3 m complete all as specified and as directed. |
| 20 | Cleaning of soakage pits/ septic tank upto 3.0 mtr depth and removal of sludge silt/ liquid/ mud/ sand/ water etc in foul position and removing the same from site to outside the MoD land complete all as specified and as directed. |
| 21 | S&F in repairs, SFRC Manhole cover of size 1000mm x 600mm x 70mm thick laid over existing drain complete all as specified and as directed by Engr-in-Charge. Notes: - (i) Make of SFRC Manhole/drain cover and frame : (a) M/s PS Concrete (b) M/s KK Manhole.(c) Or equivalent as approved by GE |
| 22 | Supply and Fixing in repairs, SFRC manhole cover of size 600mm x 600mm x 70mm thick with frame set in cement mortar 1:4 complete all as specified and as directed. Notes: - (i) Make of SFRC Manhole/drain cover and frame : (a) M/s PS Concrete. (b) M/s KK Manhole.(c) Or equivalent as approved by GE |
| 23 | M&L for hiring of chassis mounted deep suction and high pressure jetting high flow machine which consist of one no. chassis mounted machine having suction/ blower capacity of 6400cum/hr and 80% vaccum by reputed international standard blower and jetting capacity of min 390lpm with pressure of 2300 PSI by suitable standard pump complete. Note:- Log Book with machine number shall be maintained for record purpose duly signed by all concerned. |
| 24 | S&F in repair 100mm bore cast iron waste and vent pipe in any length with or without ears fixed to walls with and including suitable clamps after every one mtr of interval with cement joints fixed to wall complete all as specified and as directed. |
| 25 | S&F in repair 75mm bore cast iron waste and vent pipe in any length with or without ears fixed to walls with and including suitable clamps after every one mtr of interval with cement joints fixed to wall complete all as specified and as directed. |
| 26 | S&F in repairs for CI bends 100mm size with oval access door complete all as specified and as directed. |
| 27 | S & F in repairs CI Bends (any radius) diminishing pieces or tapers of 75 mm dia fitted with oval access door complete all as specified. |
| 28 | S&F in repairs 110mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to walls with and including including suitable PVC clamps complete all as specified and as directed. |
| 29 | S&F in repairs PVC (SWR) bends, 110mm dia fixed to PVC pipes complete all as specified and as directed. |
| 30 | Demolition of brick work or stone/boulder masonry build in cement mortar including all quions/archers etc completed all as specified and as directed. |
| 31 | Taking down cement or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and as directed. |
| 32 | M&L for brick work with old size sub class 'B' bricks, straight or curved on plan exc 6M mean radius built in CM (1:6) complete all as specified and as directed by Engr-in-Charge. |
| 33 | M&L for brick work with sub class 'B' bricks, straight or curved on plan, exc 6M mean radius, built in CM (1:4) complete all as specified and as directed by Engineer-in-Charge. |
| 34 | M&L for rendering 15mm thick in CM (1:4) on brick/ concrete surfaces of walls finished even and fair complete all as specified and as directed by Engineer-in-Charge. |
| 35 | M&L for cement concrete (1:4:8) type D2, (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed by Engineer-in-Charge. |
| 36 | Demolition of RCC (reinforcement cut as required to facilitate demolition) n exc 15cm thickness for landing, cooking platform and chajja etc complete all as specified and as directed. |
| 37 | M&L for precast cover slab in cement concret (1:2:4) type B1 (using 20mm graded stone aggregate) set in CM (1:4) as in landing, cover slabs ( for man holes, septic tank and drain cover etc.) chullah hoods, troughs, shelves and similar articles with plain faces including all necessary forms & moulds etc complete all as specified and as directed. |
| 38 | M&L for TMT mild steel bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for column, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed by Engineer-in-Charge. |
| 39 | M&L 18 to 20mm thick Granite (of jet black) work (table rubbed and polished) as in steps, jambs, gate, pillars, window cills, cooking plateforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed by Engineer-in-Charge. Note:- Exposed edges to granite shall be finished with half round nosing and cost of same shall be deemed to be included in unit rate. |
| 40 | Demotion of Cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed by Engineer-in-Charge. |
| 41 | M&L for 75mm thick PCC (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in floor etc complete all as specified and as directed by Engineer-in-Charge. |
| 42 | M&L for Chequered cement concrete coloured tiles of size 30cm x 30cm x 25mm thick, set and jointed in neat cement slurry and pointed with coloured cement to match in floor with and including over 20mm screed bed in cement mortar (1:6) complete all as specified and as directed by Engineer-in-Charge. |
| 43 | M&L heavy duty digital coloured parking tiles of size 30cm x 30cm x 8 to 10 mm thick, set and jointed with grey cement and pointed with coloured cement to match in floor with and including over 20mm screed bed in cement mortar (1:6) complete all as specified and as directed by Engineer-in-Charge. |
| 44 | M&L for PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in kerbs or mud stops, rounded or chamfered edges, etc complete all as specified and as directed by Engineer-in-Charge. |
| 45 | M&L for precast cement concrete louvres and jallies, 55mm thick (measured solid) in PCC (1:2:4) type B0 (using 12.5mm graded stone aggregate set in cement mortar (1:4) including all mouldings but excluding frame complete all as specified and as directed by Engineer-in-Charge. |
| 46 | Dismantling posts or struts (wood, steel or RCC) any section, including taking out embedded portion by demolation of cement concrete or any type of work complete all as specified and as directed by Engineer-in-Charge. |
| 47 | Dismantling fencing wire, barbed wire any type complete all as specified and as directed by Engineer-in-Charge. |
| 48 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed by Engineer-in-Charge. |
| 49 | Excavation in post holes each not exceeding 0.5 Cum, getting out, returning filling in and ramming earth or broken rubble mixed with around earth in layers not exceeding 25 cm thick, watering and removing surplus spoil to a distance not exceeding 50 m and making good surface complete all as specified and as directed by Engineer-in-Charge. |
| 50 | M&L for PCC (1:3:6) type C2 (using 40 mm graded stone aggregate) as in foundations, filling and mass-concrete complete all as specified and as directed by Engineer-in-Charge. |
| 51 | S&F MS angle iron as in fencing posts, struts & \\"Y\\" angle holes drilled in for securing wire including cutting top to shape & with flat iron for securing wire mesh including all necessary drilling, bolting or riveting,weldings etc Fe-290 grade 165, complete all as specified and as directed by Engineer-in-Charge. |
| 52 | S&F Mild steel screw bolts (machine made) with hexagonal / square heads at one end & screwed the other/ screwed both ends, each screwed end to be fitted with washers & one hexagonal or square nut, n exc 5cm long dia of shank 5 to 10 mm complete all as specified and as directed by Engineer-in-Charge. |
| 53 | S&F Mild steel round bar 10 mm dia and over cut to length, bend to shape required, including cranking, bending spirally for hopping for column, hooking ends and binding with and including security bolts post and struts in fencing including cutting top to shape as directed, drilling holes, notching for wire etc., complete all as specified and as direcetd. |
| 54 | M&L for preparation of new steel and iron surface of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of zinc chrome primer complete all as specified and as directed by Engineer-in-Charge. |
| 55 | M&L for painting of new steel surfaces of any description not otherwise described n.exc 10cm in width or girth including preparation of surfaces, priming with red oxide zinc chrome primer finished with two coats of synthetic enamel when unconnected with other painting or when painted in different tint complete all as specified and as directed. |
| 56 | Suply only chain link MS galvanised fencing of mesh size 50 mm square with 10 gauge wire and not less than @2.80Kg per Sqm, complete all as specified and as directed. |
| 57 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and as directed. |
| 58 | S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete complete all as specified and as directed. |
| 59 | M&L preparation of new plastered surfaces of wall and applying two coats of exterior emulsion paint over one coat of primer complete all as specified and as directed by Engineer - in- charge. |
| 60 | M&L for 15mm thick rendering using ready-mix cement based mortar on brick or concrete surfaces on external walls, fascia, parapet and chhajja, surface finished even and fair without using extra cement complete all as specified and as directed. Make:- Ultratech / Dr. Fixit / Fosroc |
| 61 | M&L for glossy finished machine pressed precast concrete interlocking paver block any shape and size, with grey cement and pigment to match, conforming to IS 15658-2006 of 60mm thick M-35 grade with and including over 50mm thick sand cushioning complete all as specified and as directed by Engineer-in-charge. Please Enable Macros to View BoQ information |