| 1 | Demoliton of cement concrete (un reinforced) of any description and in any position not other wise specifically provided for, complete all as specified and directed. |
| 2 | Taking down cement plaster or cement lime plaster of any description including racking out joints, haking for key , scrubbing down with water etc and prepare to receive new plaster, complete all as specified and directed. |
| 3 | M&L for dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed. |
| 4 | M&L for dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed. |
| 5 | Demolition of brick work or stone masonry built in cement mortar including all quoins, pillars etc from parapete etc and removal unserviceable brick/brick bats, complete all as specified and directed. |
| 6 | M&L for brick work with sub class 'B' bricks using old size bricks, straight or curved on plan exc 6 M mean radius built in CM 1:6 as in parapets etc, complete all as specifed and directed. |
| 7 | M&L for rendering 15mm thick in cement mortar (1:6), on fair faces or brick work or concrete surfaces, finished even and fair etc, complete all as specified and directed. |
| 8 | M&L for rendering 15mm thick in cement mortar (1:4), on fair faces or brick work or concrete surfaces, finished even and fair and mixed with water proofing compound @ 200ml per 50 Kg weight of cement (1 Bag), complete all as specified and directed.(Note: WPC will be measured and paid separately). |
| 9 | M&L for 10 mm thick rendering in CM (1:3) on fair faces of brick work or concrete surface of Chajja, roof Projection & slab etc ceiling surfaces finished even and fair, complete all as specified and directed. |
| 10 | M&L for 5mm thick rendering in CM (1:3) on fair faces of brick work or concrete ceiling surfaces finished even and fair including taking down old ceiling plaster etc, complete all as specified and directed. |
| 11 | M&L for two coats of cement base paint including preparation of new surfaces of walls, complete all as specified and directed by Engr-in-Charge. |
| 12 | M&L for preparing newly plastered surfaces of wall and applying three coat of white wash etc, complete all as specified and directed. |
| 13 | M&L for preparing newly plastered surfaces of ceiling surfaces and applying three coats of white wash etc, complete all as specified and directed. |
| 14 | M&L preparing new plastered or unplastered surfaces of walls and applying two coats of distemper oil emulsion, white or tinted over 1 mm thick wall care putty, complete all as specified and directed. |
| 15 | M&L brooming down plastered/unplastered old decorated surface of wall incl cornice etc and applying two coat of white wash, complete all as specified and directed. |
| 16 | All as per item No 15 above but on ceiling, complete all as specified and directed. |
| 17 | M&L for Preparation of old decorated surface of wall incl cornice etc and applying one coat of oil bound distemper in any colour, complete all as specified and directed. |
| 18 | All as per item No 17 above but two coats of oil bound distemper in any colour on wall, complete all as specified and directed. |
| 19 | M&L for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 20 | As per item no above 19 but plain sheet as in walls,ridges etc, complete all as specified and directed. |
| 21 | Steel work in tubular trusses/ rolled angle section for framed structures including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240, complete all as specified and directed. |
| 22 | Mild steel screw bolts (machine made) with hexagonal or square heads at one ends and screwed the other ,or screwed both ends each ends to be fitted with washers and one hexagonal or square nut nexc 5cm long and 12 mm dia, complete all as specified and directed. |
| 23 | M&L for preparing new or previously untreated steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed. |
| 24 | M&L 25 mm thick PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in floor finish, complete all as specified and directed. |
| 25 | Demolition of Mud/mud puska in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof), complete all as specified and directed. |
| 26 | Dismantling of brick tiles laid bedded and pointed in any morter or brick tiles on roof , floors, channels, kerbs, aprons etc,cement concrete of any description & in any position not otherwise specifically provided for, complete all as specified and directed. |
| 27 | M&L for PCC 1:3:6 type B-1using 20mm graded crushed stone aggregate for providing cement concrete as levelling and roof kerbs or mud stops, filling in Angle post including finishing the surface, complete all as specified and directed. |
| 28 | M&L for 25mm thick PCC 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in roof padding, benching existing roof slab to slope as per existing or as directed finished surface even and fair, complete all as specified and directed. |
| 29 | M&L for screed bed of 10mm thick in cement mortar (1:4) cover concrete surfaces of roof, mixed with @ 200ml liquid water proofing compound by 50Kg weight of cement (1 bag) as per manufacturerrs instruction inclduing finishing surfaces even and smooth without using extra cement, complete all as specified and directed. (WPC shall be measured and paid separately). (Note: WPC will be measured and paid separately). |
| 30 | M&L for cleaning the roof surfcae from dust /dirt and any other foreign materials and applying a coat of bituminius primer @ 0.30 liters per square meter uniformity after the surfaces fully dried, complete all as specified and directed. |
| 31 | M&L for applying a coat of hot blown bitumen of grade 85/25 conforming to IS 702 over APP Membrane @ 1.20 Kg/Sqm, complete all as specified and directed. |
| 32 | M & L for APP based polymeric water proofing membrane minimum weight 3 Kg/ Sqm and minimum 3mm thick reinforced with polyster non wove fabrick (Weight not less than 150gms/Sqm or as per IS), laid over hot bitumen surface by torched application with the strict supervision of manufacturers technical supervisor. Membrane shall be laid with 100mm side/end lap on prepared surface as per manufacturer instruction work shall be carried out strictly with the technical tradesmen and supervision of technical staff of manufacturer, complete all as specified and directed. |
| 33 | Supply and fixing Heat Resistant Terrace Tiles with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and loped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 oarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, ncludingrubbing and polishing of the surface upto 3 cuts complete, including providing skirting in the same manner, complete all as specified and directed. |
| 34 | M&L for cutting out cracks to V section in existing roofs or terrace, cleaning out and filling solidly with a hot mixture of bitumen and clen dry sand (1:1) (by weight), complete all as specified and directed. |
| 35 | Supply only liquid integral water proofing compund. Make Dr Fixit Pidipfoor LW+, complete all as specified and directed. |
| 36 | M&L for plain cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) as in cills bencing and other similar bands, plinth courses, parapets, coping bed plates and the like inclduing weathering, slightly rounded or chamfered angles and throating finishing surface even and smooth as directed inclduing use and waste of form work, complete all as specified and directed. |
| 37 | S&F in repairs stack clamps for 110mm bore of pipe made out of 50mmx5mm flat iron and 16mm dia round iron stays including bolts and nuts and securing ends of stay to wall or roof etc with PCC (1:2:4) type B-1 of 100x100x100mm, complete all as specified and directed. |
| 38 | S&F in repair 0.63 mm th plain galvanised sheeting fixed on crumple joints fixed with screw on wall/ roof as required, complete all as specified and directed. |
| 39 | Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning etc and hoisting if required reconnecting and re-fixing in position exc 250 ltr n.exc 500 ltr cap etc, complete all as specified and directed. |
| 40 | Demolition of RCC 500/1000 ltr water tank of any description and in any position not otherwise specifically provided for, complete all as specified and directed. |
| 41 | S&F for 500 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including GI Union, checked nut and 20 mm PTMT Float valve, complete all as specified and directed. |
| 42 | S&F for Rotational moulded polythene water storage tanks, hoisted and fixed in position 500ltrs capacity including GI union, checked nut and 20mm PTMT float Valve, complete all as specified and directed including taking down old PVC tank and removing to store, complete all as specified and directed. |
| 43 | S&F for Rotational moulded polythene water storage tanks , hoisted and fixed in position 1000ltrs capacity includin GI union, checked nut and 20mm PTMT float Valve, complete all as specified and directed including taking down old PVC tank and removing to store, complete all as specified and directed. |
| 44 | S&F in repair 20mm dia ball valves high pressure of with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe, complete all as specified and directed. |
| 45 | S&F for 20mm dia Gun-metal, globe or gate valves,with iron wheel screwed both ends for iron pipe or for unions and fixed in repair, complete all as specified and directed. |
| 46 | Taking up or down steel water tubing galvanised and removing to store 15 mm dia, complete all as specified and directed. |
| 47 | Taking up or down steel water tubing galvanised and removing to store 20 mm dia, complete all as specified and directed. |
| 48 | S&F 15mm dia medium grade galvanized water tubing with all necessary fittings and fixed complete walls, complete all as specified and directed. |
| 49 | S&F 20mm dia medium grade galvanized water tubing with all necessary fittings and fixed complete walls, complete all as specified and directed. |
| 50 | Refixing old steel tubing 15mm bore and connections in new or old position (Walls, ceiling, floors, etc.), complete all as specified and directed. |
| 51 | Refixing old steel tubing 20mm bore and connections in new or old position (Walls, ceiling, floors, etc.), complete all as specified and directed. |
| 52 | S & F in repair of PVC tank cover for 500 to 1000 Ltr capacity matching with PVC tank cover with existing tank at the site, complete all as specified and directed |
| 53 | Cleaning of overhead tank by removing all scale and dirt etc from RCC/PVC tank from mouth of circulating pipe etc to the entire satisfaction of engineer in charge ( Capacity exceeding 250 ltr and not exceeding 500 Ltr including writing date of cleaning of each tank, complete all as specified and directed. |
| 54 | Alla as iper itm No. 53 but exceeding 500 L not exceeding 1000 Ltr capacity, complete all as specified and directed. |
| 55 | Supply and fixing repair ball valve of 25mm dia high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screw for iron pipe and fixed, complete all as specified and directed. |
| 56 | M&L for sunken portion incl demolition of existing PCC, WC, P/S Trap and removing the material out side MD land, complete all as specified and directed.(a) preparation of RCC surface of sunken slab (floor) by brushing and cleaning throughly with water (b) application of two coats of poly urethane based chemical treatment (as per manufracture instruction DR FIXIT/FOSROC/CICO/STP) (c) 15 mm thick (1:4) plaster over chemical coating incl finished even & smooth without using extra cement all as directed. Note:- 1. continuty with cementitious water treatmentbeyond sunken portion in toilet shall be maintaned. |
| 57 | M&L for taking down cement plaster incl tile etc and removing the material out side MD land, complete all as specified and directed.(a) preparation of RCC surface of sunken slab (side) by brushing and cleaning throughly with water (b) application of two coats of poly urethane based chemical treatment (as per manufracture instruction DR FIXIT/FOSROC/CICO/STP) (c) 15 mm thick (1:4) plaster over chemical coating incl finished even & smooth without using extra cement all as directed. Note:- 1. continuty with cementitious water treatmentbeyond sunken portion in toilet shall be maintaned. |
| 58 | M& L for cement concrete type E2 1:5:10 (40mm graded crushed stone aggregate) as lean concrete in filling / Mass concrete, complete all as specified and directed |
| 59 | M&L for 25mm thick Cement concrete type B-0, 1:2:4 (12.5mm graded crushed store aggregate), complete all as specified and directed. |
| 60 | Dismantling floor hearth or wall tilling including cement mortar bedding , removing unserviceable tiles and rubbish off the premises for minor repair to floor tiles/ nahani traps / concealed stop cock and GI tubing in wall etc in patches, complete all as specified and directed. |
| 61 | S&F for non skid ceramic coloured tiles 300mmx300mmx 8 to 10 mm thick in floor set and jointed less neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:6, complete all as specified and directed. |
| 62 | Material and labour for glazed ceramic coloured/ designer tiles including highlighter on verticle surface of size 300X450X 8 to 10 mm thick set and jointed with cement slurry and pointing in white cement to match over and including 10mm thick backing in cement mortar 1:4 in skirting / dado, complete all as specified and directed. |
| 63 | S&F (in repair) vitreous china squatting pan Orissa Pattern size 580x440mm white with integal foot rest (excluding flushing cistern and flush pipe) including connection to trap and flushing pipe complete including trap, set with cement concrete, complete all as specified and directed. |
| 64 | Supply and fixing (in Repair) vitreous china wash down water closet (pedestal pattern) white (excluding flushing cistern and flush pipe) and P or S trap including connection to drain (or outgoing pipe) and to flushing pipe anti-syphonage pipe etc complete all as specified and directed. including plastic water closetseat closed pattern with flat bottom and cover and mild steel chromiunm plated or aluminum hinging device, complete all as specified and directed. |
| 65 | S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position, complete all as specified and directed. |
| 66 | S&F in repair 10 litres capacity PVC valve less, symphonic action type flushing cistern; low level, white, with inlet, ball valve, float and handle including bracket, complete all as specified and directed. |
| 67 | S&F in repair 75 mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement, complete all as speified and directed. |
| 68 | S&F in repair 15mm dia Bib taps chromium plated fancy type cast copper, with crutch or butterfly handle screwed down, screwed for Iron pipe or for brass ferrule, complete all as specified and directed. |
| 69 | S&F in repair brass chromium plated 2 way bib cock with wall flange 15 mm dia including fixing to pipe, complete all as specified and directed. |
| 70 | S&F in repair 15mm dia stope valves/angle cock fancy type chromium plated with long shank and cup cast copper alloy screwed down, high pressure withcrutch or butter fly handle screwed both ends for iron pipe, complete all as specified and directed. |
| 71 | S&F in repair 15mm dia PVC connection of length 450mm fixed as in repair including taking out the existing unserviceable, complete all as specified and directed. |
| 72 | Taking down soil, waste and rain water pipes (any size or pattern) including all fittings, heads, shoes, bends, swan-necks, bends etc, complete all as specified and directed. |
| 73 | S&F in repairs 110mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints fixed to walls, complete all as specified and directed. |
| 74 | S&F PVC (SWR) 75mm bore pipes single socketed in any length with rubber ring joints laid in trenches or in floors, complete all as specified and directed. |
| 75 | S&F in repairs 110mm bore PVC (SWR) bends any radius, complete all as specified and directed. |
| 76 | S&F in repairs 75mm bore PVC (SWR) bends any radius, complete all as specified and directed. |
| 77 | S&F in repair for PVC (SWR) Junction single (Single T) equal or unequal of 110mm with access doors etc, complete all as specified and directed. |
| 78 | S&F for in repair PVC (SWR) Junction single (Single T) equal or unequal of 110mm, complete all as specified and directed. |
| 79 | S&F in reapir PVC (SWR) vent cowl of size 110mm dia, complete all as specified and directed. |
| 80 | Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. Please Enable Macros to View BoQ information |