| 1 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: All kinds of soil |
| 2 | Supply and filling of dry stone soling in foundation trenches/under floors tightly hand packed with hand ramming, dressing ,watering incld. carriage of material from source to site of work complete |
| 3 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 4 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level in 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 5 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 6 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 7 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 8 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. for mass concrete. |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platforms. |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for: Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 12 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in Cement mortar 1:6 ( 1 cement : 6 coarse sand ) includng extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level |
| 13 | 15mm Cement plaster on the rough side of single or half brick wall of mix 1 : 6 ( 1 cement : 6 fine sand) |
| 14 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2 mm thick |
| 15 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20mm nominal size stone aggregate. |
| 16 | Providing wood work in frames of doors, windows, clesrestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately) First class imported KD wood including all carriages |
| 17 | Providing and fixing 35 mm thick panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. imported KD wood including all carriages. |
| 18 | Providing and fixing Float glass panes 3mm thick glass pane (weighing not less than 10 kg/sqm) including cost of Beading and Nails. |
| 19 | Distempering with dry distemper of approved brand and manufacture (two or more coats) and of required shade on new work, over and including water thinnable priming coat to give an even shade |
| 20 | Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) |
| 21 | Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 150x10 mm |
| 22 | Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 100x10 mm |
| 23 | Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 125 mm |
| 24 | Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 100 mm |
| 25 | Al-Drop with lock |
| 26 | Hooks |
| 27 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded |
| 28 | Providing & fixing colour coated (Hi-Rib) G.I sheet roofing 0.50mm thick incl. vertical/curved surface fixed with polymer coated J or L hooks bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I limpet washer and over lapping of sheets complete in horizontal vertical trusses incl. cutting to size and shape wherever required including Ridges or Hips of 60 cm overall width colour coated sheets 0.50mm thick and valleys of 90 cm width colour coated sheets 0.50mm thick etc complete as per the directions of Incharge Engineer. including all carriages.. |
| 29 | Applying priming coat: With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 30 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two or more coats on new work |
| 31 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 32 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil |
| 33 | Providing and commisioning lighting points incld wiring for lighting points in 1.5 Sq.mm PVC insulated copper wire and 2.5 Sqmm PVC insulated multi-strand copper wire for lighting sub mains,6 amp 1 way switch,2 mm thick PVC conduit/Channel with bends,junction boxes etc ,6 amp S Pole MCB ,10 amp DP MCB,2 way DB for housing MCB and hylem sheet of ISI mark and approved make with wooden box recessed in wallls with acessories incld all carriages (concelead type 12 watt) |
| 34 | Providing and commissioning heating point incld wiring for heating points in 2 .5 sq.mm PVC insulated multi-strand copper wire and 4 sq.mm PVC insulated multi-strand copper wire for heating sub-mains, 16 AMP switch socket combine,,2 mm thick PVC conduit/Channel with bends, Junction boxes etc , 10 Amp S pole MCB ,2 way DB for housing MCB and hylem sheet of ISI mark and approved make with wooden box recessed in /over wallls with acessories complete incld all carriages |
| 35 | Providing and commissioning of fan point incld wiring for fan points in 1.5 sqmm PVC insulated multi strand copper wire,1200 mm ceiling fan /225 mm exhaust fan with ceiling roses and PVC square block ,350 watt electronic fan dimmer, 2 mm thick PVC conduit/Channel with bends, Junction boxes etc, 6 mm S pole MCB ,10 amp DP MCB , 2 way DB for housing MCB for lighting circuits and hylam sheet of ISI mark and approved make with wooden box recessed in wallls with acessories complete incld all carriage and costs of Fan and all other material involved. |
| 36 | Taking of photographs of size 125mm x 100mm Pre Execution, During Exucation and Post Execution to be submitted with bill complete Job. (Geo tagged photographs showing Longitude and latitude) |
| 37 | Carriage of materials by MTSand 05 km |
| 38 | Carriage of materials by MTAggregates 20 km |
| 39 | Carriage of materials by MTBricks 50 km Please Enable Macros to View BoQ information |