| 1 | Hire charges of J.C.B for road cutting including fuel, lubricant and opeerator of the machine all complete. For near gouri place , Meghlal roy sarani. Ward no 39 |
| 2 | Dismantling all types of plain cement concrete work stacking serviceable materials at site and removing rubbish as direction within a lead of 75 m. In ground floor including roof (a) Upto 150 mm thick |
| 3 | Supplying Bleaching Powder of approved brand (DCM/Modi/Kanoria) including all charges and free delivery at site. |
| 4 | Cleaning the chokage of AC/DI/CI/UPVC pipes in the existing line by split bamboo passing through the new pit on the line and cleaning silt, bats or any obstructed materials in the line and cleaning by washed water (work to be executed as per prior approval and direction of EIC. |
| 5 | Bituminous pucca road (approx. 450mm depth) cutting by using gaiti, chisel, hammer etc. and picking uip the withdrawing excavated materials and remove the same within distance of 30mtr. at least all complete for fixing/crossing all dia of pipe line as per direction of EIC |
| 6 | Supplying, fitting and fixing in position G.I. pipes of TATA make forunderground works with all necessary accessories,specials viz.socket,bend, tee, union, cross, elbow, nipple, short piece etc.including cost of all materials,jointing materials ,cutting pipes,making threads,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed with two coats of painting on G.I. pipes and specials with bituminous paint complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.Payment for painting will be made seperately (viii) 100 mm dia. medium quality |
| 7 | (II) Cement concrete with 30 mm down graded shinglesexcluding shuttering. N.B.Variety In ground floora) 1:3:6 proportion |
| 8 | Opening the cap / plug of washout point and opening sluice valve to clean the pipe, cleaning the cap / plug and sluice valve after completion of the work including earth work in excavation and refilling the same, draining out washed water etc. as per direction of ElC and replacing RCC Top slab cover where necessary including refixing the opened cap/plug in position complete. |
| 9 | a) Construction of RCC street stand post (700mm height) of RCC (1:1.5:3) footing over 75mm thick 4:2:1 P.C.C over a single B/F soling with 1% reinforcement, connected with saddle piece & 15mm dia brass ferrule with supplying fitting, fixing 15mm dia G.I. nipple, G.I.socket, G.I. 200mm x 150mm reducing elbow and 20mm dia GI(m) TATA pipe of (avg.) 2.6mtr. long and one 15mm dia alloy Iron with brass spindle bib cock with socket and 20mm G.I. elbow 2nos. with 15mm GI(m) TATA pipe of 0.225mtr. for connection of stand post to distribution line as per deptt. design and drawing as per direction of EIC along with Construction of platform of size CC platform (1:2:4) over a single B/F soling below G.L over 150mm.thick sand filling, neat cement finish over platform and inner side of band and 15mm thick cement plaster (4:1) on top of platform band and outside upto G.L. as per deptt. drawing and as per direction of EIC |
| 10 | Construction of different dia Sluice valve /Air valve /Washout chamber in different sizes for village road where light traffic run and for main road where heavy traffic run as deptt.approved drawing with 25cm thick brick work (1:6) over cement concrete (4:2:1) over a single B/F soling over150mm.thick sand filling in foundation including earth work in excavation and disposal of excess earth from work site with RCC (1:1.5:3) cover slab 100mm / 150mm thick slab on top of chamber with 1% reinforcement in RCC cover slab with necessary opening for operation of valve all complete including cost of labour & materials as per Departmental Dwg. [Reinforcement type:- Other manufactuerers not specified] i) 100mm dia |
| 11 | Supplying, laying, fiting, fixing and jointing of UPVC pipes conforming to IS:4985-2000 with latest revision and amendments, if any, with necessary UPVC/CI specials, CIDF sluice valves, as per relevant I.S. specification including labour charges for earth work in excavation in any kind of soil including mixed soil with boulder ,road sub-grade and its flanks but excluding moorum and laterite or sand stonehard arock including cutting of brick payment without damaging the existing telephone/electrical cable line etc.(in case of damage of any type of cable line during excavation, necessary damaged charges as applicable by the respaective authority will be borne by the ency in his own cost.Loading, unloading, carrying of pipes, specials, valves from the local store to work site and lowering laying of pipes specials valves carefully intrenches maintaining proper levels and alignment ,jointing the pipe and specials including supplying of good quality/approved brand solven cement (as per IS:14182-1994 including cost of all fabricated PVC fitting i.e. tees,bend, reducers, adopter etc.as per IS:101 1988 and makin flange joints including supplying required quantity of nuts, bolts and rubber insertion (CIDF sluice valves will be supplied by the departmentfree of cost) as required at site by adopting suitable method so as to facilate the maintenance of pipe line locally as per conventional methodincluding back filling the trenches with good earth obtained from excavation of trenches including consolidation with watering in layer notexceeding 150mm thk. with maintaining an average depth of cushion of 1.10mtr. from the top of pipe line including making interconnection with distribution pipes etc. all complete as per drawin direction and satisfaction of the E.I.C N.B. i) Manufacturer’s test certificate for UPVC pipe & specials to bproduced before laying of pipe line. ii) Laying of pipe line including cost of pipe & fittings/specials butexcluding cost of valves. 110mm (OD) at ward no 47 in(chadmoni, promod nagar) & ward no 46 |
| 12 | Supply of C.I. special |
| 13 | Supply and delivery of CIDF sluice valve (Special type) PW-1.00 of different dia make with CI double flanged non rusting spindle sluice valves conforming to IS 14846 -2000 with latest emended having body dome/bonnet and cover of C.I.Gr-F.G 210mtr. spindle of IS-6603 G.R- 12/Gr-13 non-magnetic, nuts seat rings are of Gunonetal as per IS:318 LTB-2 flanges and drilled to IS:1538 Part IV & VI valves are suitable for max. working pressure of 10kg/cm2(seat test) and body tested to 15kg/cm2.N.B: The above item should be procured from the reputed manufactures as per deptt. approved vender list a)100 mm dia. |
| 14 | Carrying CI/DI pipes with specials and valves and lowering placing inposition and laying carefully inside the trenches in proper alignment andgradient etc. including earth work in excavation of adequate width as perspecification having min. clear cover from top of pipe is 1.10mtr. belowexisting ground level in any kind of soil including mixed with boulder,road sub-grade and its flank,but excluding moorum and laterite and stoneetc.without damaging the exisiting telephone/electric cable etc.(in case ofdamaged if any type of cable line during excecution , necessarydamaged charges as applicable by the respective authority will be borneby the agency in his own cost) preparing the bottom surface forcontinuous bedding of pipe line and laying pipes, fitting, fixing specialsand valves with bailing out water if any including carriage of pipes,specials and valves from local deptt. store within 8KM and back filling thetrenches with excavated earth in layers to original condition as perspecification and direction of EIC. The surplus materials after executionof work are to be return to the deptt. store.N.B: i) Any deviation from required clear cover of 1.10mtr., due to siteadverse condition, prior permission is to be obtained from the EIC inexceptional situation and payment will be made on prorate basis over therate of entire itemii) No payment will be made without hydraulic test of the pipe line eitherpart or fulliii) The pipes, specials and valves , rubber gasket will be supplied deptt.free of cost. 150mm dia. ( Ramkrishna Coloni ward 47) |
| 15 | Add. @ 18% GST |
| 16 | Add. @ 1% CESS Please Enable Macros to View BoQ information |