|
| 1 | Providing jungle clearance in Borrow area, building premises flanks and slopes on the roads, canals and embankement by removing the grass and trees grith upto 300 mm ,removal of stumps of tree cut the jungle bushes from the top including weeding out shrubs including roots and levelling etc. complete as per direction of E/I .(Vide Item No. 5.1.3.1 Part - B/ 2.03 (ii) Part - A) |
| 2 | labour for cleaning |
| 3 | Providing designation 75 B brick work in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I. B.C.D 5.2.14 |
| 4 | Providing 12 mm thick Cement plaster in (1:6) on Wall with approved quality of clean course sand of F.M. 1.5 including the cost of screening curring with all leads & lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I (5.7.3) |
| 5 | Extra for cleaning the old surface by scrapping the entire old white wash or colour wash including cost of scaffolding all complete as per direction of E/I. 5.8.9 |
| 6 | Providing two coats of snowcem of approved shade and make over old surface including washing cleaning and preparing the walls, scaffolding , curing and taxes all complete as per building specification and direction of E/I. B.C.D 5.8.23 |
| 7 | Supplying, fitting, and fixing M.S. Grill made of 20X6mm M.S. Flate as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I. 5.5.12 |
| 8 | Providing two coat of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I. B.C.D 5.8.45 |
| 9 | Taking down old door and window shutters including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.5.10.10 |
| 10 | Supplying, fitting and fixing good quality, well dressed and well seasoned sal wood work in chaukhat in doors, windows skylights, fanlights and C/W celetial windows openings, including wedge over all clamps complete including application of two coats of wood preservative of approved quality on the surface butting walls and lintels all completeas per building specification and direction of E/I. |
| 11 | Supplying, fitting and fixing 30mm thick solid core type decorative single leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resine of standard make with Aluminium fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I. 5.4.34 |
| 12 | Providing 25 mm thick Cement Concrete M20(1:1.5:3) -do- slope in with aaproved quality of stone chips of 20 mm to 6 mm - do- including screeing,shuttering and mixing cement concrete in mixer with admixture of integral water proofing and placing in position --do-- E/I. 5.12.2 BCD |
| 13 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 8.2.1.2 |
| 14 | Float glass panes of nominal thickness 5 mm (weight not lessthan 12.50 kg/sqm) Window |
| 15 | sand lead 20km (p) |
| 16 | brick lead 15km (p) |
| 17 | stone chips lead 15km (p) |
| 18 | cement lead 3 km (p) |
| 19 | Dismantling pucca brick or lime work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. (5.10.1) |
| 20 | Reinforce cement concrete works in beam suspended floors, roof having slop to 150 landing bankoni, selves, chajja, lintel, bend - do - do - R.C.C. (1:1.5:3) tone aggregate 20 mm nominal size - do - do - E/I. (5.3.11) |
| 21 | Providing R.C.C. Work in wall (any thickness including attached plasters, buttresses plinth and stream coarse column pillers R.C.C. (1:1.5:3) (stone aggregate 20 mm nominal size) - do - do - E/I. (5.3.10) |
| 22 | Providing designation 100 A brick work with fly ash lime brick (FLAG) condieminf ro IA - 12894 - 1990 (0'-9'' x 4'-5'' x 0'-3'') in CM (1:6) in super structure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick motor joint, cost of screening materials rakingout joints 15 mm depth, curring, taxes and royalty all complete as per building specification and direction of E/I (5.2.52) |
| 23 | Providing 12 mm thick Cement plaster in (1:6) on Wall with approved quality of clean course sand of F.M. 1.5 including the cost of screening curring with all leads & lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I (5.7.3) |
| 24 | Providing Tor. steel rainforcement for R.C.C.work with cutting, bending fixing in work place as per design and drawing grade of steel F.E. - 500 (only valied for SAIL, TATA, JSPL, ELECTRO Steel Ltd and vizal steel) all complete job as per building specification and direction of E/I. (5.5.4 & 5.5.5 ) 8 mm Dia Rod 40% |
| 25 | (b) 10 mm Dia Rod 20% |
| 26 | (c) 12 mm Dia Rod 40% |
| 27 | Centering and shuttring including struting proping etc. and removel in (i) foundation - do - do - E/I |
| 28 | (ii) Band at Lintel (5.3.17.21) |
| 29 | Supply of vertical post 65 x 65 x 6 (gr.) (B.C.D. - P - 43,, Sl. - 158, M - 195 b(iii)) |
| 30 | Labour for febricating erection hoisting and fixing in position structural steel work in R.S. jolst, channel, angle, tee, flal, plate, latice member built up compound section in column , grider starircase or truss including cost of gusset plates, holding down bolts, anchor plates at all heights and depths bolting, welding (machining wherever necessary) with supplying a priming cosat of red lead paint all complete as per approved drawing,building specification and direction of E/I. (5.5.28) |
| 31 | Providing and fixing concertina coil fancing with punched tape concertina coil 600 mm dia 10 metre openable length (total length 90 m) having 50 nos. rounds per 6 metre length iron 'Y' shaped placed 2.4 m ro 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire stud tied with G.I. staples and G.I. clips to retain horizontal including necessary bolts or G.I. earbed wire tied to angle iron, all complete job as per building specition and direction of E/I (D.S.R. 16.53) |
| 32 | Providing two coats of snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper, scaffolding, curing and taxes all complete as per building specification and direction of E/l.5.8.24 |
| 33 | (a) Cement + Steel Lead 03Km. Surface road |
| 34 | (b) Sand Lead 20 Km. Surface road |
| 35 | (c) Chips Lead 15 Km. Surface road |
| 36 | (d) Bricks Lead 15 Km. Surface road |
| 37 | Wiring for light/point/Exhaust fan point/call bell point with 1.5 sq.mm FRPVC insulated copper conductor cable in surface/recessed PVC conducit as required. With piano type switch phenolic laminated sheet MS Box earthing the point PVC insulated copper 1.5 Sq.mm FR PVC insulated copper conductor single core cable etc. at required.1.1.3 Group C |
| 38 | Wiring for circuit/sub main wiring along with earth wire with the following sizes of PVC insulated copper conductor single core cable in surface/racessed PVC conduit as required.1.7.2 :- 2x2.5 sqmm+1x2.5sqmm earth wire |
| 39 | 1.7.3 :- 2x4 sqmm+1x4 sqmm earth wire |
| 40 | Supplying and fixing of following way single pole & neutral, sheet steel , MCB distribution board 240 volts, on surface /recess , complete with tinned copper bushbars ,neutral busbar, earth bar , din bar ,detachable gland plate , interconnections ,phosphatized and powder painted including earthing etc. as requried. (but without MCB/RCCB/ISOLATOR) 2.9.4 :- 4WAY Double door , horizontal type. |
| 41 | Supplying and fixing following rating four pole 415 volts Isolator in the existing MCB DB complete with connections testing and commissioning etc as required2.15.1 :- 40 amps |
| 42 | ITC ceiling fan |
| 43 | ITC exhaust fan upto 450mm sweep |
| 44 | Supplying Celling Fan 48'' (1200 mm) |
| 45 | Supplying 300 mm exhust Fan 12'' (300 mm) |
| 46 | Supplying LED 15/16 Watt |
| 47 | LED FLOOD LIGHT 50/60 W |
| 48 | S/F Batten Holder -Do - -do- |
| 49 | E/W in excavation in foundation trenches in ordinary and hard soil ( vide classification of soil Item – A and B ) and disposal of excavated earth clearance to distebce up to 50 M including all lifts with leveling, removing the trenches removing roots of trees shrubs all complete as per specification and direction of E/I. ( 5.1.1 + 5.1.2) |
| 50 | Providing Coarse Clean sand in filling in foundation trenches or in plinth including removing and watering in layers not exceeding 150 mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per specification and direction of E/I.(Mode of measurement compacted volume). (5:1:10) |
| 51 | Providing designation 75- B, Brick Flat Soling joints filled with local sand including cost of watering, taxes and royalty all complete as per building specification and direction of E/I (5.6.3) |
| 52 | Providing and laying in position cement concrete (1:2:4) of specified grade exccluding the cost of centering and shuttering (stone aggregate 20 mm nominal size) - do - do - E/I. (5.3.1.2) |
| 53 | Providing and laying reinforced cement concrete (1:1.5:3) of specified grade excluding the cost of centering and shuttering (Stone aggregate 20 mm nominal size) - do - do - E/I. (5.3.9.1) |
| 54 | Providing designation 75- B, brick work CM (1:6) IN Foundation and plinth with approved quality of clean coarse sand of F.M 2 TWO 2.5 Including providing 10 mm thick mortar joint , cost of screening material ,racking out joints 15 depth , curing ,taxes and royalties all comp. as per BCD Specification and Direction of E/I. |
| 55 | Providing R.C.C. Work in wall (any thickness including attached plasters, buttresses plinth and stream coarse column pillers R.C.C. (1:1.5:3) (stone aggregate 20 mm nominal size) - do - do - E/I. (5.3.10) |
| 56 | Providing designation 100 A brick work with fly ash lime brick (FLAG) condieminf ro IA - 12894 - 1990 (0'-9'' x 4'-5'' x 0'-3'') in CM (1:6) in super structure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick motor joint, cost of screening materials rakingout joints 15 mm depth, curring, taxes and royalty all complete as per building specification and direction of E/I (5.2.52) |
| 57 | Reinforced cement concrete work in beam's suspended floor's roof's having slop to 15'' landing, balconies, shelves chajja, lintels & bands - do - do - all complete as per building specification and direction of E/I. (R.C.C. (1:1.5:3) (stone aggregate 20 mm nominal size) (5.3.11) |
| 58 | Earth filling in foundation trenches and plinth - do - do - as per building specification and direction of E/I. (5.1.7) |
| 59 | Centering and shuttring including struting proping etc. and removel - do - do - E/I |
| 60 | (ii) Column (5.3.17.6) |
| 61 | (iii) Plinth Beam (5.3.17.21) |
| 62 | Providing Tor. steel rainforcement for R.C.C.work with cutting, bending fixing in work place as per design and drawing grade of steel F.E. - 500 (only valied for SAIL, TATA, JSPL, ELECTRO Steel Ltd and vizal steel) all complete job as per building specification and direction of E/I. (5.5.4 & 5.5.5 ) |
| 63 | (b) 10 mm Dia Rod 25% |
| 64 | (c) 12 mm & above Dia Rod 35% |
| 65 | Providing 12 mm thick Cement plaster in (1:6) on Wall with approved quality of clean course sand of F.M. 1.5 including the cost of screening curring with all leads & lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I (5.7.3) |
| 66 | Finishing wall with premium Acrykic smooth exterior paints with silicon addifives of required shade - do - do - all complete as per specification and direction of E/I. (D.S.R. 13.47.1) |
| 67 | Supply of vertical post 75 x 75 x 6 (gr.) (B.C.D. - P - 43,, Sl. - 158, M - 195 b(iii)) |
| 68 | Labour for febricating erection hoisting and fixing in position structural steel work in R.S. jolst, channel, angle, tee, flal, plate, latice member built up compound section in column , grider starircase or truss including cost of gusset plates, holding down bolts, anchor plates at all heights and depths bolting, welding (machining wherever necessary) with supplying a priming cosat of red lead paint all complete as per approved drawing,building specification and direction of E/I. (5.5.28) |
| 69 | Providing and fixing concertina coil fancing with punched tape concertina coil 600 mm dia 10 metre openable length (total length 90 m) having 50 nos. rounds per 6 metre length iron 'Y' shaped placed 2.4 m ro 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire stud tied with G.I. staples and G.I. clips to retain horizontal including necessary bolts or G.I. earbed wire tied to angle iron, all complete job as per building specition and direction of E/I (D.S.R. 16.53) |
| 70 | (a) Cement + Steel Lead 3 Km. Surface road |
| 71 | (b) Sand Lead 20 Km. Surface road |
| 72 | (b) Chips Lead 15 Km. Surface road |
| 73 | (c) Brick Lead 15 km |
| 74 | Earth work in excavation in foundation trenches in ordinary soil(vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees,Extra for earthwork in hard soil as per specification and direction of E/I. |
| 75 | Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building -do-. |
| 76 | Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.5.6.3 |
| 77 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) |
| 78 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centring and shuttering ,finishing and reinforcement-all work upto plinth level:1:1.5:3 (1 cement : 1.5 coarse sand (zone III) : 3 graded stone aggregates 20 mm nominal size) |
| 79 | Reinforced cement concrete work in walls(any thickness),including attached pilaster,buttresses,plinth and string courses ,fillets ,columns,pillars,piers,abutments,posts and struts etc above plinth level upto floor five level,excluding cost of centring ,shuttring,finishing and reinforcement:1:1.5:3 (1 cement : 1.5 coarse sand (zone III) : 3 graded stone aggregates 20 mm nominal size) |
| 80 | Centering and shuttering including strutting,propping etc and removal of from for columns, pillars, piers,abutment,posts and struts |
| 81 | Reinforced cement concrete work in beams , suspended floors, roofs having slope up to 15 degree landings, balconies , shelves, chajjas , lintels , bands , plain window sills , staircases and spiral stair cases above plinth level up to floor five level , excluding the cost of centering , shuttering finishing and reinforcement , with 1:1.5:3 (1 cement :1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 82 | Centering and shuttering including strutting,propping etc and removal of from for lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 83 | Providing 12mm thick cement plaster (1:4) with clean coarse sand of F.M 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I |
| 84 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. |
| 85 | Providing Tor steel reinforcement of rods as per approved design and drawing including carriage of Rods (straight or in coils) to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust,-do- |
| 86 | Providing two coat of painting with ready mixed paint of approved shade and make over steel surface including cleaning the surface throughly, scaffolding and taxes all complete as per specification and direction of E/I and Providing primer one coat or red lead paint of approved makeover new steel surface -do-- |
| 87 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent |
| 88 | i. Cement + Steel |
| 89 | i. Sand |
| 90 | iii Stone Chips |
| 91 | iv stone metal |
| 92 | (V) bricks lead |
| 93 | Providing fitting and fixing vitreous white glazed earthen ware Wash hand basinof parry hindustan or any other I.S.S approved make supported on painted C.I or R.S brackets with 32mm C.I,15mm dia C.I body brass spindle stop cock of approved quality of weight not less than ,350 grams ,32 mm PVC waste pipe 750mm long with brass coupling at one end and making plumber joints etc.all complete as per specification and direction of E/I. |
| 94 | Providing and fixing male ended 15 mm dia brass bib cock of approved quality (wt. not less than 350 gms) with extra socket all complete as per specification and direction of E/I. |
| 95 | Providing and fixing C.P brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore |
| 96 | Providing and fixing C.P Soap Dish Holder having length of 138 mm breadth 102 mm, height of 75mm with concealed fitting arrangements, weighing not less than 110 gms. |
| 97 | Providing and fixing PTMT extension nipple for water tank pipe,fitting or approved quality and colour. 15 mm nominal bore weighing not less than 32 gms |
| 98 | Supplying fitting and fixing (b) mirror of 6mm thick glass bevelled edge mirror including C.P brass revolving fitting 3mm ply wood board and C.P hinges to fix with mirror. Complete with all materials as per specification and direction of E/I. (i) 600mm x450mm size |
| 99 | (C) (i)C. P brass towel rail 20mm x 600mm with bracket container |
| 100 | Making Holes in wall for laying GI Pipes & Restoring the same after pipe laying as per specification (250 mm Thick Wall) |
| 101 | Providing & Fixing Brass /CI Stop Cork Of approved quality (A) 20 mm Dia |
| 102 | Providing and fixing CPVC pipes do……..do…… all complete job. Exposed on Wall20 mm nominal outer dia Pipes |
| 103 | 32 mm nominal outer dia Pipes |
| 104 | Conselled 15mm dia |
| 105 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion(110 mm diameter) |
| 106 | Supply ,fitting and fixing white glazed fire's clay sink of approved make with overflow arrangement supporeted on C.I or R.S painted braket 40mm dia C.P brass chain and rubber plug 40mm dia pvc waste pipe about 750mm long with brass coupling at one ended 15mm C.I bidy brass spindle bib cock of approved quality of wieght not less than 450 gms. including wall and making good the same etc all complete as per specification and direction of E/I. (i) Kitchen sink 600 mm x450 mm x250 mm |
| 107 | Supplying 100mm dia submersible pump sets confirming to IS 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless pump shaft and polypropylene/ noryl impeller. Motor suitable for working on 415V+10%, 3HP, 5o Hz, A.C. supply with cable guard, thrust carbon / fiber bearing to withstand entire hydraulic thrust, water proof winding shall be provided. The pump set shall be suitabl for direct coupling. Pump shall have suitable outlet as per manufacturers design. Anti thrust stream lined nonreturn valve shall be provided with pump. 3 meter submersible copper conductor cable in single / double run shall be provided with each pump.Submersible pump Set of 2 HP Single Phase 150 mm dia (with Bronze impeller) up to 8 stages. |
| 108 | D.O.L. Starter |
| 109 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittingswith one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 40mm nominal outer dia pipe |
| 110 | Rope and motor lowering and fitting |
| 111 | Polythene water storage tank of mark with cover and suitable lcocking system in double layer confirming to Is 12701-1996 with ;atest revision |
| 112 | Labour required for site clearence do-do-E/I |
| 113 | Earth work excavation in foundation Trenches in ordinary soil (vide classification of soil item -A) and disposal of excavated earth as obtained . all complete as per approved design, building specification and |
| 114 | Providing Coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding150 mm thick with all leads and lifts . all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 115 | Provinding and laying 60 mm thick factory made cement concrete interlocking paver block of m-30 grade by blocking compaction and pattern over and including 50 mm thick compaction of approved size and design and shape laid in required colour and pattern and bed of coarse sand filling the joints with fine |
| 116 | Providing Plain cement concrete in open foundation complete as per drawing and technical specifications p.c.c m-15(1:2:4)do-do-E/I |
| 117 | sand(AVG LEAD 20 km(p) |
| 118 | s/chips( AVG LEAD 15 km(P)) |
| 119 | paver block/bricks(AVG LEAD 20 km(P)) |
| 120 | Cement (Lead 03 Km.(P)) |
| 121 | Add Signboard and Photographs |
| 122 | Goods & Service Tax (G.S.T.) - |
| 123 | Labour Cess - Please Enable Macros to View BoQ information |