| 1 | Hanging Solar Power Fence |
| 2 | P.P Reel insulator-Must be of virgin plstic material.Polypropylene or equivalent with break down voltage of 15 KV(weight 25gm avh, length 4.6 cm avg) |
| 3 | Strain insulator- Must of poly polypropylene plstic rated for 15 kv UV stabilized,(weight 40gm avg, length 7 cm avg) |
| 4 | GI post 12 feet-2\\" GI pipe guage Thickness, total 14.5 ft length modified to 12 feet length and cut and welding to 90 degree bend 2.5 feet length at top end and having diametrically opposite holes of size 6mm at end of bend pipe |
| 5 | Intermediate post (T angle post)-6ft.,paited(25mmx25mmx3mm)having holes of size 6mm at required interval of fencing installation |
| 6 | Supporting post- 10ft., GI-1\\",14 guage Thickness,painted |
| 7 | Stay (t angle)-2 ft., painted(25mmx25mmx3mm) |
| 8 | 12 swg HT wire-12 guage,25mm dia High tensile with zinc coating for use as conducting wires for binding strain inulator |
| 9 | 14 swg Binding wire- high quality zinc coating wire for binding reel insulators,tighing support post with corner post |
| 10 | 1.5 mm stainless steel wire rop 304 grade-1.5 mm stainless steel wire rop 304 grade |
| 11 | Aluminium ferruel- aluminium ferrule inner dia 3mm |
| 12 | Wire tightner- Permanent wire tightner made of special aluminium alloy designed for KV,UV stabilized |
| 13 | Earth rod- copper plated earth rod 14mm -3 ft. length |
| 14 | Earthing compound- earthing compound 8kg |
| 15 | Gate handle- gate handle and spring assembly. Handle made of polyethyelene |
| 16 | Leadout cable- Lead out cable for fencie system double insulated GI cable inner core wire 2 sq.mm. hot dipped galvanlsed steel core, cable of with standing 15 KV should be provided to prevent bimetal salt formation at connections |
| 17 | Single core 2.5 mm sq. cable- 2.5 mm2 single core copper cable for connecting the solar panel to the tuber battery through charge control unit with required terminal sockets, nut and bolt, washer |
| 18 | Lightining diverter- 15 KV rod gap arrester,must be capable of diverting stray lightining and adjustable for spark raps adequate earthing to be provided |
| 19 | 100 watt solar panel- 100 watt/12 Volt and above Poly Crystalline with 10 year warranty having IEC/MNRE certification |
| 20 | Charge Control Unit- 20A, 12/24 V PWM charge controller unit of standard make suitable to control the charging of the tubular battery |
| 21 | Energizer- Energizer with 10 KV Output safety Standerds to be followed and BIS 302-2-76 IEC60335-2-76. Switch high,medium and low power of settings |
| 22 | Fence alarm system- Fence alarm system conering area of 1.5 KM |
| 23 | solar panel supporting stand with metal box painted ( for battery and energiser)- 18 Guage thickness metal box (lockabe). GI sheet, painted should be capable of housing battery, charge controller and energizer and fixed with required clamps and nud and bolt on solar panel support stand made of GL pipe of 50mm daimeter and B class type with suitable arrangement for holding the panel |
| 24 | Warning sign- Polyethylene plastic with satuatory warning with signs |
| 25 | Tubular Battery 12v,100AH- 12v, 100 AH C10 rating with full 5 year replacement warranty(tower battery) for energising the energiser Please Enable Macros to View BoQ information |