| 11 | SCH 'A' PART XII (MISC B/R & E/M ITEMS) Note:- Excavation and Earthwork to the extent required for execution of relevant item under this schedule unless otherwise specified shall be measured and paid under relevant items of Schedule 'A' Part-II. |
| 12 | INTERNAL WATER SUPPLY |
| 13 | Supply and fixing table mounted Tall Boy Sensor Basin Mixer (Hot & Cold) Battery/DC operated, Premix water supply kit for Wash Basin complete all as specified and directed. Make: JAQUAR KUBIX Prime series SNR- CHR-35017PMPK (Chrome). |
| 14 | Supply and fixing Angle Cock of cast copper alloy, chromium plated, fancy type, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed 15 mm bore complete all as specified and directed. |
| 15 | Supply and fixing Soap Dish of suitable size complete all as specified and as directed. |
| 16 | Supply and fixing corner glass shelf of size 300x300mm and fixed complete all as specified and as directed. |
| 17 | Supply and fixing 15mm dia two way angle cock of cast coper alloy, chromium plated, fancy type, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed 15 mm bore complete all as specified and directed. |
| 18 | Supply and fixing 15 mm dia bib cock , regular swinging spout single with wall flange (wall mounted model) of cast copper alloy, chromium plated, fancy type screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed 15 mm bore complete all as specified and directed. |
| 19 | Supply and fixing Sink made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union pipe, overall size 495x420mm, bowl size 410x330x160mm complete all as specified and as directed. |
| 20 | INTERNAL ELECTRIFICATION |
| 21 | Supply and fixing LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size 1 x 16 watt, complete all as specified and directed. |
| 22 | Supply and fixing flame proof/weather proof flood light fitting 90 watt CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable complete all as directed by Engr-in-Charge. |
| 23 | Supply and fixing new generation energy saving & environmental friendly long life LED flood light 100 watt 230 V AC outdoor type with high pressure die cast aluminum housing with toughened glass and heat resistant and indvidual high power LED's with thermal management in multiple optics,high efficiency >120 lm/W and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including making electric connection with three core copper cable with all accessories complete all as specified and directed. |
| 24 | Supply and fixing LED light fittings 1x/20 watt ,220 voltAC decorative box type with driver holder including 20 watt LED tube light connecting up with 3 core flexible cable copper conductor of suitable size from ceiling rose complete all as specified and directed. |
| 25 | Supply and fixing new generation energy saving & environmental friendly long life LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum housing with toughened glass and heat resistant and indvidual high power LED's complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics,high efficiency >120 lm/W with IP 66 protection including making electric connection with three core copper cable with all accessories complete all as specified and directed . |
| 26 | Supply and fixing flame proof wall mounted fan 18\\" 0.25 HP, single phase, complete all as specified and directed . |
| 27 | Supply and fixing flame proof DB 12 way, lightening distribution panel with complete internal bus bar & wiring up to terminals and Incoming MCB SPN - 01 No, Outgoing MCB SP - 10 Nos complete all as directed by Engr-in-Charge. |
| 28 | Supply and fixing flame proof DB 08 way, lightening distribution panel with complete internal bus bar & wiring up to terminals and Incoming MCB SPN - 01No, Outgoing MCB SP - 06 Nos complete all as directed by Engr-in-Charge. |
| 29 | Supply and fixing flame proof DB TPN 4 way lightening distribution panel with complete internal bus bar & wiring up to terminals and Incomer MCCB 100 Amp- 01 No and out going 12 Nos SPN complete all as directed by Engr-in-Charge. |
| 30 | Supply & fixing exhaust fan made of sturdy engineering plastic complete with louvers shutter volt 230 V 50 Hz RPM 1200 copper winding of sweep 250mm complete all as specified and directed . |
| 31 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1400mm sweep. Min air delivery 245 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor(BLDC) complete all as specified and directed . |
| 32 | Supply and fixing wall mounted fan /air curculator heavy duty 450 mm sweep bracket mounted type copper wound motor ISI marked energy efficient with fixing accessories complete all as specified & directed. |
| 33 | Supply and fixing mobile industrial HVLS (high volume low speed) fan 4 ft dia ,240 v,50 Htz complete all as directed by Engr-in-Charge. |
| 34 | LIGHTNING PROTECTION |
| 35 | Supply and fix ready made type PVC Junction box IP 65 of size 200 mm x 160 mm x 98 mm having shutter & lifting knob with provision of earthing strip entry glands complete all as specified directed and fixed the box on wall/poles with suitable size of nut, bolts and washers complete all as specified and as directed by Engineer-in-Charge. |
| 36 | FIRE DETECTION AND ALARM SYSTEM |
| 37 | Material and labour for unarmoured sheathed and twin core twisted cable FRLS multi stranded copper conductor 1.50 Sqmm 2 core 1100 volts control cable as per IS-7098 and drawing through on wall/ceiling in rigid metallic steel conduit pipe 20 mm dia heavy duty in suitable size with all necessary fittings complete all as specified and as directed. Note : (i) unarmoured sheathed 1.50 sqmm 2 core with one run of steel conduit pipe shall be measured as one unit. |
| 38 | Supply and fixing UPS 1 KVA (1000 VA),40-50 Min backup, boost function for low input over voltage protection Extended input voltage range of 135 to 300 volt UPS to battery backup mode including Battery back up system for 48 hrs suitable size of Battery should be include for fire alarm control panel all as directed by Engr-in-Charge. |
| 39 | Supply, install, testing and commissioning of active repeater panel for remote monitoring with 1 x 40 character liquid crystal display with backlight illumination, operating voltage 18-32 Vdc, rated voltage 24 Vdc, Alarm current 120 mA, Ambient temprature 5 to 45 deg celcius, all as per directed by Engr-in-Charge. |
| 40 | Supply, Installation, testing and commissioning Net work card for integration of 2 loop Panels into a net worked system one network are required for two panel, complete all as specified and directed. |
| 41 | Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and as directed. |
| 42 | EXTERNAL ELECTRIC SUPPLY |
| 43 | Supply & Installation commisioning and testing of 100 KVA capacity transformer step down 11 KV to 433 Volt at no load, 3 label rated as per BEE norms/IS-1180 (Part-I) 2014, copper wound, step down indoor type oil immersed naturally cooled (ONAN) corrugated wall design with external cooling tubes/fins, core type delta connection on primery (HV side) in accordence with vector group DYN 11 with nuetral brought out on secendory side (LV side) with off load tapping on HT side to vary secondary voltage +/- 10% in four steps of 2.5% on either side to be charged by means of hand operated off load tap changing gear, floor mounted including all standerd accessories as per the ratting on transformer as specified in IS/IEC code such as supply and first filling of new transformer oil of die electric strength not less than 40 KV, dial type thermometer vapour pressure type rang 0-120 degree centigrate with indicater reseting device, rating plate, 2 Nos earthing terminals, air release wall plug, rollers, stop taps, dehydrating breather with silica gel, oil conservator with filter type drain valve oil level gauge, explosive vent, all as per in IS 1180 (Part-I) 2014 complete all as specified and directed. |
| 44 | Supply,fixing ,commissioning and testing of servo controlled voltage stabilizer (Confirming to as per BIS 9815 : Part I : 1994), Three phase AC system, 50 Hz of capacity 100 KVA Naturally oil cooled, indoor, unbalance type load, copper wound, with microprocessor based control card, digital type, relay free smooth and silent operation with 1st filling of new insulating oil as per BIS standard packed in sealed containers, including necessary incoming and outgoing connection, complete all as specified and having following specifications : (a) Input voltage 300 V to 480V ( or as customer requirements) (b) Output voltage stabilized at any designed/desired voltage 415V + 2.5% (c) Rated frequency 50Hz (d) No distortion in wave form (e) Response time not to exceed 10 milli seconds (f) Sensitivity (+) 1% (g) Rate of correction 8 volt /second (h) Efficiency more than 98% (i) Type of load : Three phase, unbalanced type (j) Multifunction meter 3 phase 415 volts showing Voltage, Amps & Hz. |
| 45 | (k) Oil quantity as recommended by manufacturer complete with oil level indicator showing minimum and maximum level of oil and temperature gauge. (l) Charging motor of suitable capacity. (m) Termination : Input & output termination as per IS : 3347. (n) Operation : Auto or Manual.(o) Metering : Digital AC voltmeter with selector switch for input & Output voltage. Protection (i) Overload Cut-Off and short circuit Protection (ii) High/Low voltage cut off (iii) Bypass arrangement in case of emergency (iv) Single phase Prevention (v) Spike and surge protection (vi) Earth Fault protection.Indicator Digital (i) Power indicator (ii) Voltage indicator (iii) Frequency Meter (iv) Power Factor indicator (v) Ammeter, Temperature Meter, Digital Ammeter& Digital voltmeter. (vi) Phase sequence indicatior.(vii)Oil level indicator |
| 46 | Supply,erecting and fixing in true vertical position , steel tubular swaged poles complete with MS base plate ,final taper plug,bolts,nuts and screws as specified type 410 SP-55 (11 meters long) Including black bituminous paint in inner portion & upto planting height, all necessary excavation & earth work in any type of soil for foundation of poles, PCC 1:3:6 type (C-2) (using 40 mm graded stone aggregate ) in foundations below GL, PCC 1:2:4 type (B- 1) (using 20 mm graded stone aggregate) in plinth block(coping) of size 600 X 600 X 300 mm above GL , removing surplus soil to a distance n. exc. 50 m & depositing where directed, including necessary form work and and providing 3 Nos of 30cm wide circular bands with Aluminium & blue paint starting from plinth level at a gap of 30cm in between 2 bands and numbering of poles, and numbering of the poles shall be done with synthetic enamel painted letter of shape & size complete inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed. |
| 47 | Material & Labour for drilling suitable dia horizontal bore holes for insertion/ laying of 100/50/40 mm bore GI tubing of any description below/under existing road surfaces / apron /floors etc with using mechanical and / or manual devices as required at site including making good the disturbed surfaces to match with the existing streta after laying pipes complete all as specified and directed. |
| 48 | Supply,erecting and fixing in true vertical position, steel tubular swaged pole (410 SP – 31), 9 mtr long, complete with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole including 2 coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be provided with one coat of red oxide primer and two coats of aluminium paint and numbering of the pole etc.complete all as specified and directed. Note : Excavation, Earth work and PCC shall be measured and paid seperately. |
| 49 | Supply & Fixing Weather Proof thermo plastic (Polysterene) Cable Junction box, having protection class IP-66 and of overall size 155mm x 210mm x 92mm (Approx) having metric knockouts on the wall, duly fixed with the pole with aluminium strip (25x3mm) clamp, GI bolts, nuts, washers and 2 Nos polymide weather proof cable glands of cable sealing range 10mm to 17mm (Complete with check nut) and including 1 No 30 Amps 4 Way cable connector and 1 No. 6 Amps SP MCB. etc.complete all as specified and directed. |
| 50 | Supply and fixing new GI Pipe brackets made out of 32 mm dia GI pipe, medium grade, 1.5 mtr length, bent to shape , fixed with two Nos 25x3 mm size flat mild steel clamps made to shape and size and suitable nuts bolts and washers etc compete all as specified and directed. |
| 51 | Supply and fix new generation energy saving & environmental friendly long life LED streetlight made up to pressuer dia cast housing with loughned glass and indvidual high power LED's with secondery optics, IP66 protection and impact resistance of IK07 and electronic driver of 70 W LED 5700K and making necessary connections with 2.5 sqm twin core cable 1100 volts upto MS box on pole complete all as specified and directed. |
| 52 | Supply, install, testing and commissioning of Main LT panel size 100 cm x 80 cm x 40 cm enclosures cubical weather and vermin proof totally enclosed made out of 2 mm thick CRCA sheet machine pressed of suitable size to operate on 3 phase 4 wire system 415 Volts, 50HZ double door with front and rear openable with locking arrangement incl inner shutters for mounting switch gear etc, bottom gland plate with sufficient numbers of circular cable entry holes, including PCC work, brick masonary work for panel installation, prewired complete duly powder coated with comprising of the following :- |
| 53 | INCOMING:- (i) MCCB 250 Amp ,415 Volt,25 KA, 4 pole, with thermal & magnetic release rated, rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Rated Service short circuit Breaking Capacity Ics = 100% Icu at 415 V (kA rms) 50%, frame DN1-250C type,Confirms to IS/IEC60947-2 = 01 Nos (ii) Phase indicating lamp LED type with HRC fuse – 1 Set of three. (iii) ON/OFF indicating lamp on incomer feeder for status of feeder = 02 Nos (iv) Digital volt meter AC 0 to 500 volts with inbuilt selector switch duly provided with suitable size of copper insulated wire with universal coloured code of size 96x96mm-01No (v) Digital Amp meter AC up to 630 Amp with inbuilt selector switch and CT’s duly prewired with suitable size of copper insulated wire with universal colour code of size 96x96mm – 01 No. (vi) Aluminium bus bar 400 Amps capacity of suitable length insulated heavy heat shrinkable sleeves etc -04 Nos. OUT GOING :- (i) MCCB 160 Amp ,415 Volt,25 KA, 4 pole, with thermal & magnetic release rated, rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Rated Service short circuit Breaking Capacity Ics = 100% Icu at 415 V (kA rms) 50%, frame DN1-250C type,Confirms to IS/IEC60947-2 = 01 Nos (ii) MCCB 100 Amp ,415 Volt,25 KA, 4 pole, with thermal & magnetic release rated, rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Rated Service short circuit Breaking Capacity Ics = % Icu at 415 V (kA rms) 50%, frame HIM125 type,Confirms to IS/IEC60947-2 = 02 Nos (iii) Time switches 415 V three phase of 16/20 Amp rating with contactor - 01 Nos (outgoing) |
| 54 | Supply, install, testing and commissioning of AC LT panel size 100 cm x 80 cm x 40 cm enclosures cubical weather and vermin proof totally enclosed made out of 2 mm thick CRCA sheet machine pressed of suitable size to operate on 3 phase 4 wire system 415 Volts, 50HZ double door with front and rear openable with locking arrangement incl inner shutters for mounting switch gear etc, bottom gland plate with sufficient numbers of circular cable entry holes, including PCC work, brick masonary work for panel installation, prewired complete duly powder coated with comprising of the following :- |
| 55 | INCOMING :- (i) MCCB 160 Amp ,415 Volt,25 KA, 4 pole, with thermal & magnetic release rated, rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Rated Service short circuit Breaking Capacity Ics = 100% Icu at 415 V (kA rms) 50%, frame DN1-250C type,Confirms to IS/IEC60947-2 = 01 Nos (ii) Phase indicating lamp LED type with HRC fuse – 1 Set of three. (iii) ON/OFF indicating lamp on incomer feeder for status of feeder = 02 Nos (iv) Digital volt meter AC 0 to 500 volts with inbuilt selector switch duly provided with suitable size of copper insulated wire with universal coloured code of size 96x96mm-01No (v) Digital Amp meter AC up to 630 Amp with inbuilt selector switch and CT’s duly prewired with suitable size of copper insulated wire with universal colour code of size 96x96mm – 01 No. (vi) Aluminium bus bar 300Amps capacity of suitable length insulated heavy heat shrinkable sleeves etc -04 Nos. OUT GOING :- (i) MCCB 63 Amp ,415 Volt,16 KA, 4 pole, with thermal & magnetic release rated, rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Rated Service short circuit Breaking Capacity Ics = 100% Icu at 415 V (kA rms) 50%, frame DN1-250C type,Confirms to IS/IEC60947-2 = 2 Nos (1working + 01 Spare) |
| 56 | DIESEL GENERATING SET |
| 57 | Supplying, installing, testing & commissioning of factory assembled silent Diesel Engine driven generating set 1500RPM of capacity 82.5 KVA , 3 phase, 4 wire,415 volt, 0.8 PF, complete with control panel including integrated powder coated acoastic enclosure as per CPCB regulations and duly certified by agencies/labs designated by CPCB for noise and sound pollution level, etc floor mounted including PCC foundation as per manufacturer's instructions complete all as specified and directed and comprising of the following :- |
| 58 | (A) DIESEL ENGINE :Diesel Engine for required capacity for driving 82.5 KVA alternator multi cylinder, vertical type, 4 stroke, water cooled, electric start, cold starting conforming to IS : 10001/10002/BS-5514 for continuous running capable of taking 10% overload for one hour in 12 hours complete and comprising of the following :- (i) Radiator cooling (ii) Radiator fan with guard (ii) Radiator fan with guard (iv) Air cleaner oil bath type (v) Vacuum indicator (vi) Electronic governor (vii) Exhaust silencer (viii)Fuel filter & fuel hoses (ix) Fan & water pump assembly (x) Lub oil filter & Pump (xi) Electric starting system with battery charging alternator and axial type starter motor including adequate number of high capacity maintenance free lead acid battery 12 volts DC as per manufacturers requirement including interconnecting cables/leads with terminals complete with starting/stopping switch,etc - 01 Set. (xii) Engine safety shut down system against low lub oil pressure and high water pressure (xiii) Exhaust gas driven turbo charger (xiv) Oil filter (xv) Lub oil cooler (xvi) Emergency stopping switch outside canopy. (xvii) Suitably designed acoustic enclosure with locking arrangement of doors as per CPCB regulations. (xviii) Suitable pollution control device to reduce air pollution. (B) ENGINE INSTRUMENT PANEL digital type having facility for automatic/manual starting, reset switching with an indicating the following including internal control wiring controlled with MCB & connected to safety features of Engine & Alternator :- (i) Starting switch on/off (ii) Water temp guage |
| 59 | (iii) Hour meter cum RPM indicator (iv) Lub oil pressure (v) Lub oil temperature (vi) Battery charging meter (vii) Safety alarm against high water temp and lub oil pressure(C) ALTERNATOR : Shall be self excited, self regulated, brush less for 82.5 KVA continuous operation at the speed of 1500 RPM at 415 volts, 50Hz , three phase four wire system with advance electric voltage regulator to ensure high voltage accuracy with + 1% with class H insulation and SPDP enclosure directly coupled with engine through flexible coupling and confirming IS- 13364/4722 or BS-2613 of 1970 complete- 1 No. (D) Common fabricated base frame for engine & alternator made from structural channel, jerk proof PCC 1:2:4 type B1 foundation including adequate number of .suitable anti-vibration pads all as per the recommendation of the manufacture- 01 No NOTE:- Cost of suitable size of PCC foundation including 400mm extra pcc platform around the DG set from outside of the canopy is deemed to be included in the unit rate quoted by the contractor. (E) Bottom mounted steel fuel tank fabricated out of 14 SWG MS sheet of capacity not less than 8 hrs continuous operation, inside canopy, with fuel level guage, drain plug, locking arrengements, etc with & including GI pipe connections duly laid as per engineering practice complete.(F) AMF CONTROL PANEL : Supply, fabrication, fixing commissioning and testing, factory made, floor mounted, cubiocal automatic mains failure panel suitable for 82.5 KVA DG set, fabricated using 14 guage thick CRCA sheet, powder coated painting, suitable rated bus bar, internal wiring with control MCB, provn of connecting incoming & outgoing leads/bus bas as approved with and including the following accessories as under:- (i) Master switch for auto/manual/reset/off- 01 No (ii) Ammeter digital type 96x96 mm to read 0 - 500 amps with CT's 1 set of 3, aux supply 230 volts, AC, accuracy class 1.0 (iii) Voltmeter digital type,96 x 96 mm to read 0 - 500 volts aux supply 230 volts, AC, accuracy class 1.0 (iv) Digital frequency meter -01 No. aux supply 230 volts, AC (v) Push button start, stop/ reset - 01 No |
| 60 | (vi) Set of lamp for indicating load on , low pressure, high cylinder temperature, load on mains, set fails to start, low oil pressure (vii) Battery charger, connected to load side to charge battery from mains comprising of :- (a) Transformer of adequate rating. (b) Rectifiers (c) DC Ampere and volt meter (d) Charger rate selector for trickle or high charging (e) Indicating lamp for battery charging (viii) Fault accept/reset push button (ix) 02 Set of relays and contactor with MCCB, 4 ploe, 100 Amps,415 volt, 25 KA adjustable 75 to 100% for automatic start & automatically shut down of DG set.. (x) control wiring from DG set/ Control Panel to AMF panel with copper cable of suitable size & cores including PVC flexible pipe. |
| 61 | Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 3.25 meter below ground level) connected to GI strip 32x6 mm main earthing lead by means of galvanized bolts, uts and washers with connected to earth test point & to main switch board /panel etc. all as specified and testing on completion with and including necessary excavation and earth work in any type of soil, earth electrode, earthing lead from electrode to equipment/substation/panel etc, adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) for earth pit with 40 x 40 x 6 mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm graded stone aggregate) 40mm thick cover reinforced with 8 mm dia TMT bars 3 Nos both way with 12mm dia round bar handle, GI light grade watering pipe 20 mm dia with funnel,wire mesh all as shown in electrical plate no. 3 of SSR Part I of 2009 and 40 mm dia GI light grade pipe earth lead protection complete all as specified and directed. |
| 62 | Total amount of Schedule 'A' Part XII carried over to General Summary |
| 63 | Blank |
| 64 | Blank |
| 65 | Blank |
| 66 | Blank |
| 67 | GENERAL SUMMARY |
| 68 | Lumpsum price worked out by the contractor for \\"BUILDING AND STRUCTURE\\" as listed in Sch 'A' Part-I on serial Page No 35 |
| 69 | a) Lumpsum price worked out by the contractor for \\"Srl Item No. 1 of Schedule 'A' Part -I i.e DESIGN, SUPPLY AND ERECTION/CONSTRUCTION OF HANGER IN PRE-ENGINEERED BUILDING (PEB) STEEL STRUCTURE AND ANCILLARY BUILDINGS\\" |
| 70 | b) Lumpsum price worked out by the contractor for \\"Srl Item No. 2 of Schedule 'A' Part -I i.e DESIGN AND CONSTRUCTION OF PARKING SHED\\" |
| 71 | c) Lumpsum price worked out by the contractor for \\"Srl Item No. 3 of Schedule 'A' Part -I i.e CONSTRUCTION OF SEPTIC TANK FOR 50 USERS\\" |
| 72 | d) Lumpsum price worked out by the contractor for \\"Srl Item No. 4 of Schedule 'A' Part -I i.e CONSTRUCTION OF SOAKAGE WELL\\" |
| 73 | Lumpsum price worked out by the contractor for “EARTHWORK,EXCAVATION & SITE CLEARANCE” as listed in Schedule ‘A' Part II representing above / below the lumpsum price as inserted by MES for Schedule ‘A’ Part II on Srl Page No. 37 |
| 74 | Lumpsum price worked out by the contractor for “DEMOLITION & DISMANTLING” as listed in Schedule ‘A' Part III representing above / below the lumpsum price as inserted by MES for Schedule ‘A’ Part III on Srl Page No. 39 |
| 75 | Lumpsum price worked out by the contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A' Part IV representing above / below the lumpsum price as inserted by MES for Schedule ‘A’ Part IV on Srl Page No. 40 |
| 76 | Lumpsum price worked out by the contractor for “INTERNAL ELECTRIFICATION ” as listed in Schedule ‘A' Part V representing above / below the lumpsum price as inserted by MES for Schedule ‘A’ Part V on Srl Page No. 46 |
| 77 | Lumpsum price worked out by the contractor for “LIGHTING PROTECTION ” as listed in Schedule ‘A' Part VI representing above / below the lumpsum price as inserted by MES for Schedule ‘A’ Part VI on Srl Page No. 49 |
| 78 | Lumpsum price worked out by the contractor for “FIRE DETECTION AND ALARM SYSTEM ” as listed in Schedule ‘A' Part VII representing above / below the lumpsum price as inserted by MES for Schedule ‘A’ Part VII on Srl Page No. 52 |
| 79 | Lumpsum price worked out by the contractor for “ROAD/ PATH/ HARDSTANDING” as listed in Schedule ‘A' Part VIII representing above / below the lumpsum price as inserted by MES for Schedule ‘A’ Part VIII on Srl Page No. 55 |
| 80 | Lumpsum price worked out by the contractor for “EXTERNAL ELECTRIC SUPPLY” as listed in Schedule ‘A' Part IX representing above / below the lumpsum price as inserted by MES for Schedule ‘A’ Part IX on Srl Page No. 59 |
| 81 | Lumpsum price worked out by the contractor for “SEWAGE DISPOSAL ” as listed in Schedule ‘A' Part X above/below the lumpsum price as inserted by MES for Schedule ‘A’ Part X on Srl Page No. 61 |
| 82 | Lumpsum price worked out by the contractor for “AREA DRAINAGE” as listed in Schedule ‘A' Part XI representing above / below the lumpsum price as inserted by MES for Schedule ‘A’ Part XI on Srl Page No. 63 |
| 83 | Total amount of SCHEDULE 'A' PART XII (MISC ITEMS) (B/R & E/M ITEMS) brought forwarded from Serial Page No. 76 Please Enable Macros to View BoQ information |