| 1 | Main Building:SITC of Automatic Lift for Main Building (as per manufacturer design & as per detailed specification below conforming to IS17900 standard) and putting into operation after final testing in the existing lift shaft complete with all accessories and repairing the damage wall / floor if any etc to complete as reqd.Make : OTIS / KONE / SCHINDLERType: Deeper Car Passenger Lift (Bed cum Passenger Lift). Load : 1360Kgs or 20 Passenger Control: Microprocessor based with AC variable voltage & variable frequency ( VVVF)Machine:-Energy efficient machine, Gearless, With Machine RoomPosition of Machine Room: Above shaftSpeed:1 Mtrs./ SecFloor served: G+2Landing: 3, all on same sideTotal Rise : 8 Mtr (Approx) (Bidder should visit the site) |
| 2 | Operation: Microprocessor based simplex full collective with or without attendant.Signals: LCD car position indicator,car travels direction indicator in car & at all landing with call registration indicator.Leveling accuracy:±5 mm(Micro levelling arrangement ) |
| 3 | CARCar inside :As per OEM standard suitable size for Strecher accomodation or as per standard design of Awardee Agency satisfying IS code. Car Entrance : Clear Opening min 1000 mm Wide x 2000 mm Height protected with car doorCar Enclosure: SS304 with hand railCar Ceiling & Lighting: Stainless Steel with hairline finish with LED lighting and FanCar Ventilation: As per OEM StandardCar Flooring : Decorative granite flooring (As per direcion of EIC and according to this Department's Order). |
| 4 | Car Door: SS304 Centre Opening/Telescopic automatic door with controlled door drive systemLanding Door: SS304 Centre Opening/Telescopic automatic door with controlled door drive system & synchronizing operation with car door.Door Opening: Automatic power operated door with full length Photocell assembly light curtain sensor |
| 5 | PROTECTIVE DEVICES & OTHER ACESSORIESARD: Automatic rescue device complete with dry maintenance free batteries as required.for automatic evacuation to the nearest floor in case of power failure / single phasing/others.Overload Protection:Fully loaded with overload protection.On overloading the lift car will not start with door remaining open and give audio display indicationEmergency lighting in car: Battery operated emergency lighting in the lift car.Intercom system: Battery operated intercom system in Lift Car, Machine Room & Control RoomEmergency Alarm: Battery operated alarm bell system in lift car and control room |
| 6 | Fireman switch:Fireman switch at main landing terminal.a)Two Hrs Fire rated and provision of the NBC Part IV 2016 b)The Lift are design as \\"Fire Lift\\" and Shall be conspicuously indicated/marked. Voice Synthesizer: Voice announcement system (Voice Synthesizer) in the car to announce the position of the elevator in the hoist way as the car passes or stops at a floor served by the elevator.As per manufacturer's standard conforming to IS ( Coated steel belt /rope) |
| 7 | Features: Correction drive to next levelEmergency Alarm @ Main Floor Car Call backwards Overload function, constant indication/BuzzerBypass load Function Auto Cut off Fan and Light Centralized Hoisting for lesser vibration and smooth travel Pit Ladder, Micro movement LED Based Buttons L.W.D. (Load Weighing Device) Direction & Position Indicator In Car & Landing Advanced Car Position IndicationAutomatic Brake Test function supervision, Phase reversal functioning Signal Fixtures+10% to –10% Voltage Fluctuation Withstanding CapacityDoor Open Button, Car Emergency Light [TYP_ELEC_FEAT_FRD(IND_SS)] Curtain of light, fix to sillAccurate Relevelling, Automatic, Closed Door, Car door lock, BMV M, Modulated line braking, Emergency Rescue Device with audio announcer Three way intercom, Nudging service, Lift Announcer Spot Light LED |
| 8 | ADDITIONAL FEATURES : Anti- nuisance Car Call Protection, , Overload Device , Nudging, Emergency Firemen's Service, Emergancy Car Light Unit, Infrared Curtain Door Protection , Door time Protection, Emergencey Alarm Button, Extra Door time of Lobby & Parking , door Open/Close Button, Manual Rescue Operation , Auto fan Cut Off.SAFETY FEATURES:a) Over Speed Protectionb) Single Phase Protectionc) Over Load Protectiond) Phase faliure Protectione) Terminal Limit Switchf) Emergency Stop Switchg) Reverse Phase Protectionh) Delocking arrangement from Landingi) Automatic Rescue operation, Voice Synthesizer k)automatic Floor position Announcement. |
| 9 | DIMENSION OF SHAFT & POWER SUPPLYAvailable Shaft Dimension : 2100 mm (W) X 3000 mm (D)Pit Depth : 1750 mm (Bidder should visit the site)Overhead : 4630 mm (Bidder should visit the site)Electric power supply: AC 415 Volt, 3phase, 50 Hz, terminated in machine room as per ISN.B. Rates should be quoted with minor civil works, wall cutting and mending good the damages to the original finish. |
| 10 | Annex Building:SITC of Automatic Lift for Main Building (as per manufacturer design & as per detailed specification below conforming to IS17900 standard) and putting into operation after final testing in the existing lift shaft complete with all accessories and repairing the damage wall / floor if any etc to complete as reqd.Make : OTIS / KONE/SCHINDLERType: Deeper Car Passenger Lift (Bed cum Passenger Lift). Load : 1020Kgs or 15 Passenger Control: Microprocessor based with AC variable voltage & variable frequency ( VVVF)Machine:-Energy efficient machine, Gearless, With Machine RoomPosition of Machine Room: Above shaftSpeed:1 Mtrs./ SecFloor served: G+3Landing: 4, all on same sideTotal Rise : 10.5 Mtr (Approx) (Bidder should visit the site) |
| 11 | Operation: Microprocessor based simplex full collective with or without attendant.Signals: LCD car position indicator,car travels direction indicator in car & at all landing with call registration indicator.Leveling accuracy:±5 mm(Micro levelling arrangement ) |
| 12 | CARCar inside :As per OEM standard suitable size for Strecher accomodation or as per standard design of Awardee Agency satisfying IS code. Car Entrance : Clear Opening min 900 mm Wide x 2000 mm Height protected with car doorCar Enclosure: SS304 with hand railCar Ceiling & Lighting: Stainless Steel with hairline finish with LED lighting and FanCar Ventilation: As per OEM standardCar Flooring : Decorative granite flooring (As per direcion of EIC and according to this Department's Order). |
| 13 | Car Door: SS304 Centre Opening / Side Opening automatic door with controlled door drive systemLanding Door: SS304 Centre Opening/ Side Opening automatic door with controlled door drive system & synchronizing operation with car door.Door Opening: Automatic power operated door with full length Photocell assembly light curtain sensor |
| 14 | PROTECTIVE DEVICES & OTHER ACESSORIESARD: Automatic rescue device complete with dry maintenance free batteries as required.for automatic evacuation to the nearest floor in case of power failure / single phasing/others.Overload Protection:Fully loaded with overload protection.On overloading the lift car will not start with door remaining open and give audio display indicationEmergency lighting in car: Battery operated emergency lighting in the lift car.Intercom system: Battery operated intercom system in Lift Car, Machine Room & Control RoomEmergency Alarm: Battery operated alarm bell system in lift car and control room |
| 15 | Fireman switch:Fireman switch at main landing terminal.a)Two Hrs Fire rated and provision of the NBC Part IV 2016 b)The Lift are design as \\"Fire Lift\\" and Shall be conspicuously indicated/marked. Voice Synthesizer: Voice announcement system (Voice Synthesizer) in the car to announce the position of the elevator in the hoist way as the car passes or stops at a floor served by the elevator. As per manufacturer's standard conforming to IS (Coated steel belt /Rope) |
| 16 | Features: Correction drive to next levelEmergency Alarm @ Main Floor Car Call backwards Overload function, constant indication/BuzzerBypass load Function Auto Cut off Fan and Light Centralized Hoisting for lesser vibration and smooth travel Pit Ladder, Micro movement LED Based Buttons L.W.D. (Load Weighing Device) Direction & Position Indicator In Car & Landing Advanced Car Position IndicationAutomatic Brake Test function supervision, Phase reversal functioning Signal Fixtures+10% to –10% Voltage Fluctuation Withstanding CapacityDoor Open Button, Car Emergency Light [TYP_ELEC_FEAT_FRD(IND_SS)] Curtain of light, fix to sillAccurate Relevelling, Automatic, Closed Door, Car door lock, BMV M, Modulated line braking, Emergency Rescue Device with audio announcer Three way intercom, Nudging service, Lift Announcer Spot Light LED |
| 17 | ADDITIONAL FEATURES : Anti- nuisance Car Call Protection, , Overload Device , Nudging, Emergency Firemen's Service, Emergancy Car Light Unit, Infrared Curtain Door Protection , Door time Protection, Emergencey Alarm Button, Extra Door time of Lobby & Parking , door Open/Close Button, Manual Rescue Operation , Auto fan Cut Off.SAFETY FEATURES:a) Over Speed Protectionb) Single Phase Protectionc) Over Load Protectiond) Phase faliure Protectione) Terminal Limit Switchf) Emergency Stop Switchg) Reverse Phase Protectionh) Delocking arrangement from Landingi) Automatic Rescue operation, Voice Synthesizer k)automatic Floor position Announcement. |
| 18 | DIMENSION OF SHAFT & POWER SUPPLYAvailable Shaft Dimension : 1750 mm (W) X 3070 mm (D)Pit Depth : 1525 mm (Bidder should visit the site)Overhead : 4350 mm (Bidder should visit the site)Electric power supply: AC 415 Volt, 3phase, 50 Hz, terminated in machine room as per ISN.B. Rates should be quoted with minor civil works, wall cutting and mending good the damages to the original finish. |
| 19 | Cost of dismaintling from the existing 2 nos lift well & removal from the well along with its all Bracket,Rope,Rail,Car,Machine and Gate and all Other accessories |
| 20 | Less Cost of dismantled & unserviceable Materials |
| 21 | TERMS & CONDITIONS |
| 22 | Any other item or items left out from the BOQ but essentially required for successful completion of the work may be raised for inclusion in the scope of work during pre-bid meeting. Otherwise bidder has to consider left out items deemed to be included in the scope of work. Bidders are advised to physically visit the site and quote the price accordingly. |
| 23 | Defect Liability period 1 (One) Year |
| 24 | (Rates should be Quoted inclusive of all taxes & duities and GST and 1% LWC) Please Enable Macros to View BoQ information |