| 1 | Supply and errection of Double pole 11 Mtr. long 410 SP-55 ST pole support duly grouted with 1:4:8 cement concrete (1-cement , 4fine sand and 8-OBB of 40mm. nominal size) including plinthing with 20 mm. nominal size stone grit 10 Cm. Below the G.L. and 30Cm. Above the G.L. and plastering with 1:4 cement mortar, plastered and painted in the same manner as already specified for respective supports suitable for Plinth mounted type substation with different types of M.S. channels and angle iron duly fabricated for Disc. fittings D.O. fuse set, TPMO, outside dropper & bracing's including cost of material,labour and T&P required for proper completion of work as per drawing and direction of E/I. As per Annex.no. Page No. |
| 2 | ST GI BOTTOM Pole SP -55 , 11.00 mtr Long |
| 3 | S/Errection of 11 KV Double pole structure (RISER) made of following types of supports duly grouted, plinthed, plastered and pained in the same manner as already specified for respective supports S.T. pole grouted with 1:4:8 cement concrete (1-cement , 4fine sand and 8-OBB of 40mm. nominal size) including plinthing with 20 mm. nominal size stone grit 10 Cm. Below the G.L. and 30Cm. Above the G.L. and plastering with 1:4 cement mortar painting and numbering of pole and making strip with enamel paint with two Nos. channel of size 125x65mm and 65x65x6mm respectively and 2 Nos. bracing of angle iron size 65x65x6mm 3 Mtr. length fixed with packing piece and bolts and nuts as required including the cost of material, labour T&P etc. required for proper completion of work as per direction of E/I. As per Annex.no. Page No. |
| 4 | 11 Mtr. Long SP-55 |
| 5 | S/f of 11 KV, TPMO set complete With all material, labour and T&P required for Proper completion of the work. As per Annex.no. Page No. |
| 6 | S/f of 11 KV, D.O. fuse set complete With all material, labour and T&P required for Proper completion of the work. As per Annex.no. Page No. |
| 7 | S/f of 11 KV, Lighting Arrester set complete With all material, labour and T&P required for Proper completion of the work. As per Annex.no. Page No. |
| 8 | Supply and fixing of H.T/L.T. jumpering and connections on double pole/four pole. Lighting arrestor and transformer. The rates include the cost of all materials, labour and T&P etc. required for proper completion of work. As per Annex.no. Page No. |
| 9 | Making suitable earthing of ST poles /Double pole/ Section End Double pole with 2.5Mts. long 20mm dia M.S. rod with 7/16 SWG G.S. wire in 15mm dia 2Mtr. long G.I. pipe duly clamped with 3 nos clampes and binding on poles including cost of labour & T & P etc. required for proper completion of work. As per Annex.no. Page No. |
| 10 | Supply, delivery, testing and commissioning of 11KV (E) XLPE cable having compacted circular stranded aluminium conductor, conductor screening of extruded semi conducting compound. Cross linked polythylance (XLPE) insulation screening of the extruded semi conducting compound followed by copper tape, cores laid up, taped PVC inner sheath, single layer of steel strip armouring, overall PVC outer sheath conforming to IS: 7098/Part-II/ with latest ammendment for following mentioned sizes. (300 sqmm HT Cable Laying in HDPE pipe) Complete in all respects. Make:- PolyCab, Gloster, Havells, KEI ) As per Annexure No. Page No. |
| 11 | 300 sq mm 3 core H.T. Cable |
| 12 | Supply, delivery, testing and commissioning of 11KV (E) XLPE cable having compacted circular stranded aluminium conductor, conductor screening of extruded semi conducting compound. Cross linked polythylance (XLPE) insulation screening of the extruded semi conducting compound followed by copper tape, cores laid up, taped PVC inner sheath, single layer of steel strip armouring, overall PVC outer sheath conforming to IS: 7098/Part-II/ with latest ammendment for following mentioned sizes. (300 sqmm HT Cable Laying in HDPE pipe) Complete in all respects. Make:- PolyCab, Gloster, Havells, KEI ) As per Annexure No. Page No. |
| 13 | 70 sq mm 3 core H.T. Cable |
| 14 | Drilling of road crossing at depth 1.5 to 2 mtr as required and laying charges of cable in 160/110 mm dia HDPE pipe. complete with all material, labour, drilling machine and T&P etc. required for proper completion of work.As per Annexure No.- Page no.- |
| 15 | For 160/110 mm dia HDPE pipe |
| 16 | Supply and jointing of Outdoor type 11 KV Jointing Kit (HEAT SINK) for 3 core HT XLPE cable including cost of all material labour T&P etc. as per proper completion of work. (Make:- Raychem/ Dension/ 3M). Outdoor type DSR-2022, 10.5.4&1 |
| 17 | 300 sq mm outdoor type Jointing Kit |
| 18 | 70 sq mm outdoor type Jointing Kit |
| 19 | Supply and jointing of Indoor type 11 KV Jointing Kit (HEAT SINK) for 3 core HT XLPE cable including cost of all material labour T&P etc. as per proper completion of work. (Make:- Raychem/ Dension/ 3M). Indoor type DSR-2022, 10.4.4&1 |
| 20 | 300 sq mm Indoor type Jointing Kit |
| 21 | 70 sq mm Indoor type Jointing Kit |
| 22 | Supply, Delivery, Installation, Testing & Commissioning of 11 KV Straight through cable jointing kit of 3 core cable jointing Complete in all respects as required for proper completion of work. (make:- Raychem/ Dension/ 3M) As per DSR-2022, 10.6.4&1 |
| 23 | 3C x 300 sq.mm. |
| 24 | 3C x 70 sq.mm. |
| 25 | Supply, Installation, Testing, commissioning of Out door type Transformers 400 KVA, 11/0.433 kV \\"Energy Efficient\\" Copper Wound, out door, Delta-Star, Distribution Transformer as per B.I.S. 1180-2014 Standards (Level-2) with Protection Features for the above Transformer Which includes.(i) 03 Nos. Lightning Arrestor on H.V. Side(ii) M.C.C.B., L.T. Cable Box with Complete Wiring on L.V. Side. (Make: Transtron/ Elecon/ Paramax/Asian) As per Annexure No.- Page no.- |
| 26 | 400 KVA Copper wound |
| 27 | Supply, Installation, testing, and commissioning of 11KV Non-Extensible Stand Alone Ring-Main-Unit, Outdoor type with IP54 Fabrication (ensuring outdoor protection to complete RMU, including cable-boxes), SF6 gas insulated compact switchgear, comprising of following arrangements / combinations of Isolators and Fixed Type Vacuum Circuit Breakers all of rating 630Amp, cable termination from front/rear/side, having short-circuit withstand capacity of 20KA/3sec, permanently enclosed in a tank made by robotically welding stainless steel sheets, to provide IP67 Degree of Protection to live parts and Internal Arc protection (IAC 20kA), duly filled with SF6 gas with leakage rate less than 0.1% with possibility of refil at site and monitored via gas-pressure manometer as per IEC 62271-200, complete with all aceesories as described below and coupling busbars for bus-coupling of two RMUs where necessary, to meet the desired configuration. Including Cost of Boot for Cable Protation with Inter locking / with out inter locking system as per requirment of site. Complete in all respects. (Make: Cromption/ABB/Schnieder/BHEL/ Siemens.) As per Annexure No.- Page no.- |
| 28 | One side Extensible, 6 way RMU with 2 Nos Load Break Switch (LBS) Feeder & 4 Nos Vacuum Circuit Breaker (CB) Feeder with common item & Assessories for RMU. |
| 29 | Construction of Transformer plinth size 2.0x1.25x1.0 Mtrs with all materials, labour and T&P required for proper completion of work as per specification, drawing and direction of E/I. As per Annexure No.- Page no.- |
| 30 | Supply, Installation, testing and commissioning of L.T., A.C.B. 800A Pannel and earthing with existing earth through G.I. Strip of size 40x4mm or 7/8 SWG, G.S. wire as per direction of E/I. The rates are upto destination including loading, unloading and local cartage charges and cost of all materials, labour & T&P etc. required for proper completion of work. (Make :- L&T/ Crompton/ ABB). As per Annexure No. Page No. |
| 31 | S/I/T/C 200 KVAR APFC Panel with incomer 630A MCCB i) Capacitor should be heavy duty, 480 VACii) Make- LK/Schneider/Siemens iii) Compartmented Panel iv) Aluminum Busbar suitable for 630A v) Only Capacitor duty contactor should be used with capacitor |
| 32 | Construction of APFC Panel Plinth size 1500x800x1200 Mtrs with all materials, labour and T&P required for proper completion of work as per specification, drawing and direction of E/I. As per Annexure No.- Page no.- |
| 33 | S/F of Main Feeder Pillar suitable size shall be manufactured with 2mm(load bearing) 1.6mm thick for non load bearing members (Door,side,cover etc.) 16 swg CRCA sheet steel, dust and vermin proof fixead type double front compartmentalized and Floar mounted type dully power coated paint of siemens Gray shade after treatment with 8 tank chemical treatment process As per drawing of feeder pillar enclosed and the feeder pillar will be mounted on cement concrete foundation 1:2:4 core sand graded stone aggregate 20mm normal size with following Items. The rates are upto destination including loading, unloading and local cartage charges and cost of all materials, labour & T&P etc. required for proper completion of work. CPRI Approved. As per Annexure No. Page No.(i) Busbar suitable size. (Make :- Hindalco)(ii) Incoming one no. MCCB 800 AMP 4 Pole 36 KA (Make :- L&T/ Crompton/ Legrand/Havelles)(iii) Out going 4 nos. MCCB 400 AMP 4 Pole 36 KA (Make :- L&T/ Crompton/ Legrand/Havelles)(iv) Main Metering Digital Type1 Set. (Make Select AE) |
| 34 | S/F of Sub Feeder Pillar suitable size shall be manufactured with 2mm (load) bearing 1.6mm thick for non load bearing members (Dor, side, cover etc.) 16 swg CRCA sheet steel, dust and vermin proff fixead type double front compartmentalized and flooar mounted type dully power coated paint of siemens Gray shade after treatment with 8 tank chemical treatment process with following Items As per drawing of feeder pillar enclosed and the feeder pillar will be mounted on cement concrete foundation 1:2:4 coar sand graded stone aggreegate 20mm normal size with following Items. The rates are upto destination including loading, unloading and local cartage charges and cost of all materials, labour & T&P etc. required for proper completion of work. CPRI Approved. As per Annexure No. Page No.(i) Busbar suitable size. Make :- Hindalco)(ii) Incoming one no. MCCB 400 AMP 4 Pole 36 KA (Make :- L&T/ Crompton/ Legrand/Havelles)(iii) Out going 2 nos. MCCB 250 AMP 4 Pole 36 KA (Make :- L&T/ Crompton/ Legrand/Havelles)(iv) Out going 24 nos. fuse with HRC 63 AMP (Make :- L&T, HPL, Havelles)(v) Main Metering Digital Type 1 Set. (Make Select AE) |
| 35 | Supply and burring of safe Earthing Electrode T-39, Zn-Zinc Coated , Length 3000mm, outer pipe 76.3mm X 3.2 inner pipe 42.4mmX2.6mm terminal Dia, 12 mm Coating 80-100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of rataining capacity along with 30 cm square C.I. Frame with hinged cover & masonry housing (From electrode terminal to switch board, cost of 25x3 G.I. strip will be extra) Make:- As approved in U.P.P.W.D., & C.P.R.I. Certified. As per PWD SOR-2018 SI No-726(D) |
| 36 | Supply & Laying of 25mm x 3mm G.I. Strip from earth electrode derectly in the ground as required.As per UP PWD SOR-2018 SI No-716 |
| 37 | Supply and laying of aluminium conductor (LT Cable) PVC insulated armoured served sheathed cable 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on sides and on top on surface. complete in all respect. (Laying in HDPE Pipe) (Make:- Polycab, Gloster, Havells, KEI). As per Annexure No. Page No. |
| 38 | (i) 240 sq. mm 3.5 Core |
| 39 | (ii) 120 sq. mm 3.5 Core |
| 40 | Supply and Fixing of brass nickel plated comperssion Gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. Complete in all respect.The armouring of the cable shall be properly connected with the earth as per direction of E/I. UP PWD SOR-2018 SI No-503 |
| 41 | (i) 300 sqmm |
| 42 | (ii) 70 sqmm. |
| 43 | (iii) 240 Sq.mm. |
| 44 | (iv) 120 Sq.mm. |
| 45 | Supply and fixing of plain or pin type copper tin plated cable socket (Lug) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of E/I. UP PWD SOR-2018 SI No-504 |
| 46 | (i) 240 Sq.mm. |
| 47 | (ii) 120 Sq.mm. |
| 48 | (iii) 120 Sq.mm. |
| 49 | (iv) 70 Sq.mm. |
| 50 | Supply of HDPE pipes (upto PN 6 Kg Pressure Rating material Grade PE 80, Pressure Rating PN 6.0) as per relevants IS suitable for HT / LT XLPE cable. (Make :- Sudhakar, Creator Poly Extrusions LLP, Supreme, Josexim) As per Annexure No.- Page no.- |
| 51 | (i) 160 mm dia HDPE Pipe |
| 52 | (ii) 110 mm dia HDPE Pipe |
| 53 | Construction of Fencing Plinth of following sizes in Ist class brick work including, plaster and providing flat brick soling and pointing the same with 1:2 cement and fine sand mortar over 75mm. Thick cement concreting in the ration 1:6:12 in open space of the cage. Complete in all respect as per direction of E/I.As per Annexure No Page No. |
| 54 | 6.00x4.00x0.23 Mtrs size. |
| 55 | Supply and fixing of 2.45 Mtrs high Cage fabricated with 3.0 mm thick expanded metal/wire mesh of equivalent weight fixed on 50x50x6mm angle iron frame having vertical members spaced at 1.0 Mtrs. To 1.25 Mtrs. and horizontal members spaced at 1.20 Mtrs. The vertical members shall be grouted in ground and horizontal members in the wall toa depth of 300mm with ends folded. the cage shall have 1000x2000mm size single leaf door with locking arrangement having door frame fabricated with 35x35x5mm angle iron and 3 mm expended metal wire mesh of equivalent weight duly fixed with the cage member. the cage shall have nut bolt arrangement for opening the sides by providing tees 45x20Cm. of angle iron size 50x50x6mm as per direction of E/I. it shall be painted with red oxide primer and synthetic enameled paint as per direction of E/I. the job include all materials, labour and T&P for proper completion of work. As per UP PWD SOR-2018 SI. No. 1142 |
| 56 | Supply and errection of Cable Stand of size 2.45x0.30 Mtrs. Above G.L. duly grouted with cement concrete upto 45 Cm. Depth for laying cables from L.T. side of transformer made of angle iron size (65x65x6mm) having welded M.S. flat of size 50x6mm on top middle and 45 mm above ground level for fixing cable by clamping with M.S. flat of 40x4mm size as per direction of E/I. complete in all respect as per E/I.As per Annexure No. Page No. |
| 57 | S/F of G.I. Pipe of following sizes for DP cable duly clamped with supports by 2 No. with clamps of 50 x 6 mm M.S. flats bolts, nuts and washer required for proper completion of work.(Make:- Jindal/ Tata/Prakash). As per Annexure No.- Page no.- |
| 58 | 150 mm dia |
| 59 | S/F of Barbed wire 1.5 Kg. Duly clamped with 2 No. clamps made of 20 x 3 mm at both end on poles, flate including bolts, required for nuts and washer complete with all material labour and T&P etc. for proper completion of work. As per Annex.no. Page No. |
| 60 | S/F of Danger board of size 200 x 250 x 1.6 mm of M.S. sheet fixed with clamp of 20 x 3 mm M.S. flate including bolts, nuts and washer duly painted completed with all material, labour and T&P etc. required for proper completion of work. As per Annexure No.- Page no.- |
| 61 | Supply and Fixing of Cable Route Marker with cement concrete 1:2:4 (1 cement : 2 corse sand : 4 graded stone aggregate 20 mm nominal size ) of size 1000x400x100 mm in suitable masonry enclosure as directed by E/I. As per Page No………. |
| 62 | Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with single arm bracket 1 Mtr length in 1:2:4 RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P complete in all respect as per direction of Engineer incharge. As Per UP PWD SOR 2018 SI No. 641 |
| 63 | Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with Double arm bracket 1 Mtr length in 1:2:4 RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P complete in all respect as per direction of Engineer incharge. As Per UP PWD SOR 2018 SI No. 642 |
| 64 | Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 120 Watt. Confirming to IP66 and above protection complete in all respect. As Per UP PWD SOR 2018 SI No.1424 CAT AAA |
| 65 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. As Per UP PWD SOR 2018 SI No.501 (i) ,(j) |
| 66 | 16 sqmm 4 core. (i) |
| 67 | 25 sqmm 3.5 core (j) |
| 68 | Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, under ground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Incharge. As Per UP PWD SOR 2018 SI No.503 (j) |
| 69 | 25 sqmm 3.5 core. |
| 70 | Supply and fixingof plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer Incharge . As Per UP PWD SOR 2018 SI No.504 (d) , (e) |
| 71 | 16 sqmm (d) |
| 72 | 10 sqmm (d) |
| 73 | 25 sqmm (e) |
| 74 | 16 sqmm (d) |
| 75 | Supply of 63mm dia HDPE pipe (upto PN 6 Kg Pressure Rating material Grade PE 80, Pressure Rating PN 6). As per Annexure No.- Page no.- |
| 76 | S/Making of Suitable earth of street light pole with 2.5 Mtr. Long 20 mm dia M.S. rod complete with 7/16 SWG G.S. wire in 2.00 Mtr. Long 15 mm dia G.I. Pipe (0.96 Kg/Mtr.) duly clamped on pole with 3 Nos. 20 x 3 mm M.S. flat clamp with bolts nuts and washers complete with all material labour and T&P etc. rerquired for proper completion of work. As per Annexure No.- Page no.- |
| 77 | Supply and fixing of heavy duty cadmium plated copper connector with end plate complete in all respect. As per UP PWD SOR-2018 SI No-1128 C |
| 78 | Supply and fixing of street light feeder piller. The feeder will be manufacture by CPRI Approved company. M.S. CRCA sheet 1.6 mm powder coated RAL 7035 with door lock etc.(i) Incomer 125 A, 36 KA FP, MCCB with thermal magnetic release based (O/C, S/C) Release, with spreader links and extended ROH(ii) 140 A TP Power Contactor with 2 NO+2NC Aux. Contact (AC-3 Duty), 150A Aluminium Bus bar control wire, hardware.(Make ABB/L&T/HPL/Havells)(iii) Digital Voltmeter 0-500V, CL-1.0 96x96 mm .(Make AE/ELM EASURE)(iv) VSS 6A .(Make AE/ELM EASURE)(v) Digital Ammeter 0-150A, CL-1.0 96x96 mm. (Make AE/ELM EASURE)(vi) ASS 6A (Make AE/ELM EASURE)(vii) CT for meter resin cast CL-1.0 150 A/5, 5 VA .(Make KAPPA)(viii) 24 Hrs. run timer (Mannually setting type) make L&T.(ix) Auto/Manual selector switch (Make- SALZER, KAYCEE)(x) ON/OFF Push button (Make-RASS)(xi) ON/OFF Indication light LED type 220V AC RYB (Make-RASS)(xii) Phase Indicator Light LED Type 220 Volt AC (Make-RASS)(xiii) Control MCB SP 6 A, 10 KA (Make ABB/L&T/HPL/Havells)Outgoing Section(i) 63A 4 Pole MCB 10 KA (Make ABB/L&T/HPL/Havells)(ii) 63 A MCB 4 Pole 10 KA O/G feeder-3No. (Make ABB/L&T/HPL/Havells)(iii) Neutal link |
| 79 | Supply and burring of safe Earthing Electrode T-39, Zn-Zinc Coated , Length 3000mm, outer pipe 76.3mm X 3.2 inner pipe 42.4mmX2.6mm terminal Dia, 12 mm Coating 80-100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of rataining capacity along with 30 cm square C.I. Frame with hinged cover & masonry housing (From electrode terminal to switch board, cost of 25x3 G.I. strip will be extra) Make:- As approved in U.P.P.W.D., & C.P.R.I. Certified. As per PWD SOR-2018 SI No-726(D) |
| 80 | Supply & Laying of 25mm x 3mm G.I. Strip from earth electrode derectly in the ground as required. As per UP PWD SOR-2018 SI No-716 |
| 81 | Service Connection Charges Paid to UP PVVNL. Please Enable Macros to View BoQ information |