| 1 | Supply, Installation, Testing amd Commissioning of LT Panel vermin proof floor mounting , M.S. channel base with bottom and Fabricated out of 2.0/1.6mm thick CRCA sheet steel, painted with powder coated paint of shade as per the direction of Engineer In-Charge after proper sheet treatment process of sheet steel. The Bus Bar of panel shall be of Electrical grade High Conductive Aluminum alloy of appropriate cross section as per rating.The main bus bar shall run throughout the panel of rating as main incomer rating. The Bus Bar shall be supported by non hygroscopic SMC/DMC Bus Bar supports which shall be mounted on proper interval to ensure the bear the jerks of short Circuit of 50kA for panels having ACB as Incomer & 36kA for panels having MCCB Incomers. Panel shall be constructed in fully Segregated Compartment Design for Each Feeder as per 3b construction Format. The Panel shall be completed in all respect as per IS: 8623 Part-2&3. There shall be Separate Metering Compartment for incomer metering and outgoing metering.All Incomer Feeders shall be provided with Multifunction Metering along with Phase Indicating Lights and other associated components such as CT, control MCB Terminal Block etc. and all Outgoing Feeders 100A & above shall be provided with 3 phase Ammeter along with phase Indicating Lights and other associated components such as CT, control MCB Terminal Block etc. The Feeders above shall be provided ac accommodated all Measuring Instruments shall be Digital type & all Indicating Lights shall be LED type. Wiring shall be done from 1100V Grade PVC Insulated copper flexible wire. All ACB shall be Electrically operated Draw-out type with Microprocessor Based O/L, S/C & E/F Release of Breaking/ Withstand Capacity (ICU/ICs/Icw) 50kA or more All MCCB shall be Thermal Magneetic/Microprocessor with O/L & S/C Protection along with Required Spreaders & Extended Rotary Handle with pad Locking facility of Breaking capacity (ICU/ICS) 36kA or more All MCB shall be Thermal 10kA 'C' Curve. Cubicle type switch board shall be Cat-A and B only. Incoming - 200A FP MCCB 36 KA with spreaders and extended rotatory handleOutgoing - 63 amp MCCB 1Nos (36 KA with spreaders and extended rotatory handle). 32 amp MCCB 5Nos (36 KA with spreaders and extended rotatory handle). |
| 2 | Wiring for Light Point, Street Light point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate,suitable GI box and earthing the point with 1.5sq.mm FRLS PVC copper conductor single core cable etc. as required. |
| 3 | Wiring for Fan, Fresh air fan point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate,suitable GI box and earthing the point with 1.5sq.mm FRLS PVC copper conductor single core cable etc. as required. |
| 4 | Wiring for Call bell point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate,suitable GI box and earthing the point with 1.5sq.mm FRLS PVC copper conductor single core cable etc. as required. |
| 5 | Wiring for Exhaust point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate,suitable GI box and earthing the point with 1.5sq.mm FRLS PVC copper conductor single core cable etc. as required. |
| 6 | Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. |
| 7 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings)(For Plug Point and Aquaguard)((2 No. for TV) |
| 8 | Supply and Fixing of suitable size GI box with modular plate and cover in front of surface or in recess, including providing and fixing 2 nos. 3 pin 5/6A modular socket outlet and 2 nos. 5/6A modular switch, connections etc. as required. (For light Plugs to be used in non residential buildings). (For Computer pt.) |
| 9 | Supply and Fixing of brass Angle holder including connection etc. as required. |
| 10 | Supplying and drawing 1 x 1.5 sq. mm size of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.(For Inverter Wiring) |
| 11 | Supply and Fixing of suitable size GI box with modular plate and cover in front of surface or in recess, including providing and fixing 25 A modular socket outlet with 25 A modular SP MCB C curve including connections painting etc. as required. (AC & Geyser) |
| 12 | Supply and Fixing of suitable size GI box with modular plate and cover in front of surface or in recess, including providing and fixing 6 pin 15/16 A modular socket outlet and 15/16 A modular switch connections etc. as required. |
| 13 | Supplying and fixing 4 way (4+12), horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 14 | Supplying and fixing of 12 way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 15 | Supply and fixing of 5 to 32 amp rating 240/415V, 10KA, C curve DP MCB suitable for inductive load of following poles in existing DB complete with connections, testing and commissioning etc. as required. |
| 16 | Supply and fixing of 5 to 32 amp rating 240/415V, 10KA, C curve SPMCB suitable for inductive load of following poles in existing DB complete with connections, testing and commissioning etc. as required. |
| 17 | Supply and Fixing of 63 Amp. 4 Pole MCB(10KA) C curve. Make-Havells or equivalent |
| 18 | Supply and Fixing of 32 Amp. 4 Pole MCB(10KA) C curve. Make-Havells or equivalent |
| 19 | Supply and fixing of LED Tube Light with heavy duty Metal Box type Tube Light fitting 1x22 watt suitable for upto 1x 22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect2620 system lumens, >120 Lm/W, PF>0.95, THD<10%, CRI >80, sheet thickness min 0.8mm, Tube with aluminium heat sink, >300V over voltage protection, 2.5 KV internal Surge Protection, with 5year warranteeCAT AAA |
| 20 | Supply and Fixing of 20 watt LED Mirror Light Complete in all Respect.Make Havells or Equivalent with 5 years warrantee |
| 21 | Supply & fixing of water tight oblong 10 watt LED Bulkhead luminaire having pressure die cast housing with driver set confirming to IP65 and above protection, IK 08, High purity / transmisivity UV Stabilized Non yellowish diffuser/ for uniform light distribution, detachable driver set, open and short circuit protection, suitable for 24 Hr Continuous Operation, Complete in All respect. compelete in all respect.1200 system lumens, >120 Lm/W, PF>0.95, CRI >70, >300V over voltage protection, 4 KV internal Surge Protection, metal housing with 5 years warrantee |
| 22 | Supply and fixing of LED Street light Fitting with mandatory driver set having die cast aluminium body with toughend glass/ UV stabilized PC Cover and lenses suitable for 60Watt. to 72 Watt. Confirming to IP 66, and IK07 and above protection having Company LOGO Engraved complete in all respect including Labour.7200-8640 system lumens, High Power LED with lenses, >120 Lm/W, PF>0.95,, Potted driver Set in Metal housing (Not Circuitory), Phase to phase Protection at 440V & >300V auto cut and re-start feature, 4 KV internal Surge Protection, with 5 years warrantee CAT AAA |
| 23 | Submain wiring along with earth wire with the 2 x 1.5 sqmm +1x 1.5 sqmm earth wire (for Plug,Computer, Aquaduard,TV point) of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. |
| 24 | Submain wiring along with earth wire with the 2 x 4 sqmm +1 x 4 sqmm earth wire (Power Plug) of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. |
| 25 | Submain wiring along with earth wire with the 2 x 6 sqmm +1 x 6 sqmm earth wire(AC) of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. |
| 26 | Submain wiring along with earth wire with the 2 x 10 sqmm +1 x 6 sqmm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. |
| 27 | Submain wiring along with earth wire with the 4 x 16 sqmm + 2 x 6 sqmm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. |
| 28 | Supply and Laying of 35 Sq mm 3-1/2 Core Aluminium Conductor PVC insulated armoured served sheathed cables 1100V grade at a depth of 750mm below ground level over a cushion of 75mm thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc of suitable size or as directed by Engineer in Charge complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. |
| 29 | Supply and Laying of 150 Sq mm 3-1/2 Core Aluminium Conductor PVC insulated armoured served sheathed cables 1100V grade at a depth of 750mm below ground level over a cushion of 75mm thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc of suitable size or as directed by Engineer in Charge complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. |
| 30 | Supply and making end termination with brass compression gland and aluminium lugs for 3.5 x 35 sqmm (32mm) size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1kv grade as required. |
| 31 | Supply and making end termination with brass compression gland and aluminium lugs for 3.5 x 150 sqmm (50mm) size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1kv grade as required. |
| 32 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. |
| 33 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 34 | SITC of 1200 mm sweep, BEE 5 star rated, ceiling fan with brush less DC motor, class of insulation-B, 3 nos blades, 30cm long down rod, 2 nos canopies, shackle kit, safety rope, copper winding, pf not less than 0.9, service value (CM/M/W) minimum 6.00 air delivery minimum 210cum/min, 350rpm(tolerance as per IS: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts,washers, temperature rise=75degree C max, insulation resistance more than 2 mega ohm, suitable for 230V, 50Hz, single phase AC supply, earthing etc. complete as required. |
| 35 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 36 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 37 | Supply and Fixing of L.E.D. Bulbs, 9 W app. Make Havells or Equivalent |
| 38 | Supply and Fixing of Heavy Duty Exhaust Fan 300 mm size sweep 900 RPM single phase including cartage and fixing Complete in all respects.Make Havells or equivalent |
| 39 | Supply and Fixing of Fresh air Fan 200mm Sweep single phase including cartage and fixing Complete in all respects.Make Havells or equivalent Please Enable Macros to View BoQ information |