| 1 | Construction of 01 Nos. 33 KV Sadarnagar bay at 132KV Sub-station Shatrughanpur which shall be done with details of works mentioned as below :- |
| 2 | Carriage of Substation Structure |
| 3 | Proper Shifting,sorting,counting,weighing,loading & stacking of substation structures on Trucks arranged by the contractor including transportation from strorage location to the loading site. |
| 4 | Safe carriage of the substation structures loaded on trucks duly arranged by the contractor from Stockyaard/Stores of E.F.U. Naini Allahabad to 132KV S/S Shatrughaanpur ,Gorakhpur(approx. dist. 300 km )with all due care of safety & precautions during transit required for the job including the insurance/fare/toll tax etc.of all the truck. |
| 5 | Unloading of substation structures at 132KV S/S Shatrughanpur,Gorakhpur including transportation of the structures from the unloading site to the main work site. |
| 6 | Erection of structure parts the job consist of shorting, counting, shifting of all materials structure parts, nuts and bolt etc from store to erection site, proper erection of structure as per drawing and all other associated works. |
| 7 | Erection of following equipment on already erected/fabricated structure including shifting of equipments from store to work site. |
| 8 | 36 KV Single phase CT (400/200/1-1A) |
| 9 | 36 KV CT (400/200/1-1A) Junction box |
| 10 | 36 KV Line isolator including fixing of its operating Boxes & Mechanism coupling link pipe etc. |
| 11 | 36 KV Bus isolator including fixing of its operating Box & Mechanism coupling link pipes etc. |
| 12 | Erection & commissioning of 36 KV VCB with structure |
| 13 | Laying & stringing of 33KV Main Bus of Moose conductor having length 06 meter (01 Job for each phase) |
| 14 | Complete jumpering and interconnection work of different equipments from 33KV Main Bus i.e. BI, CB, CT, PT, LI etc. by Twin ACSR Panther conductor including cutting, tilting & tightening with PG Clamps/terminal clamps at both ends as per technical standard and direction of supervising engineer. |
| 15 | Erection of New 33KV Tripple feeder control and relay panel in control room at s/s including grouuting,earthing & termination of control cable, as per cable schdules including providing & fixing cable glands of appropriate sizes and ferrules etc. all other associated works as per technical specification. |
| 16 | Earthing of control panel at 2 point |
| 17 | Laying of control cable from control panel/Relay Panel to breaker /CT/PT already erected through cable trenches including removal of trench cover, dressing as per cable schedule including clamping at a distance 2 mtr. with 25x3 mm. Aluminium Strip (To be provided by Contractor). |
| 18 | 2x2.5 mm2 |
| 19 | 4x2.5 mm2 |
| 20 | 6x2.5 mm2 |
| 21 | Interconnection & termination of the above laid control cable between control and relay panels & erected eequipment i.e. CB,CT,CT Junction box including cutting & making holes in various equipment's base plates & fixing of accurate size cable glands (To be provided by Contractor) binding the numbering tags on both side of cable, making termination including all internal connection at each equipment Iike as CB,CT,CT Junction box,control panel etc.on both ends with correct ferruling for each core of cables alongwith preparation of interconnection Drawing and commissioning of the panel in co-ordination with T&C wing including providing 02 sets of Hard copies. This also include resetting of trench cover on trenches after completion of work. (ferrules & Cable glands to be provided by Contractor) |
| 22 | Earthing of Equipments |
| 23 | Laying of 32/40 mm MS round bar 700 mm below ground level including cutting, welding, painting excavation of trench and its back filling OF Trench after laying oF Earth Mat including shifting of MS round Bar from storage Place at the Sub-Station to Switchyard. |
| 24 | Fabrication of 3 meter long electrode with MS rod having 150 mm conical shape by due cutting,straightening etc.and then its piercing vertically its side the ground with top 700 mm below ground level and its welding with earth mat including shifting MS Round bar from storage place at the Sub Station to switchyard. |
| 25 | Cutting, stringing, bending, laying of following size MS flat for earthing of main and auxiliary structure, equipment structure, T/F body including fans/DM/M.Box, CT, PT, CB, LSI/BSI equipment etc including welding with main earthmat 700 mm below ground level with object to each excavation of trenches its back filling. painting with synthetic enemal green color above ground and all associated work to complete the job satisfactorily excluding cost of MS flat. |
| 26 | 50x6 mm |
| 27 | 25x6 mm |
| 28 | Painting of M.S.Earthing strips by rubbing with sand paper and wire brush then painting with one coat of red oxide primer & 2 coats (The 2nd coat of paint shall be applied at the gap of 48 hrs when Ist coat of paint is done and checked by concerned S.D.O./J.E.) Ist quality synthetic enamel paint of asian make in Bus green /Black colour as per details below: |
| 29 | 50x6 mm |
| 30 | 25x6 mm |
| 31 | Switchyard Lighting |
| 32 | Supply and fixing of new generation energy saving environment friendly long life versatile pressure die casting aluminium outdoor high beam flood light with high power of LED street light luminaries 120 watt of Havells/CGL with 2 year on site warranty.Transportation up to site and any other job requested to properly execute the complete work. |
| 33 | Providing & fixing of G.I. Pole Bracket of 40 mm dia. 'B' Class 1.20 Meter long M.S. Pipe of (ID 35 mm & OD 40 mm) bent at angle of 300 for fixing of 125 / 110 Watt LED Lamp Fittings with the help of M.S. Bracket Clamps of suitable size for fixing on G.I. Column Structure (90x90 mm) at designated place. |
| 34 | Providing & Installation of junction box on gantry structure of size 280×225×150 mm made of MS sheet of 16 gauge with Hinged Door, Painted with Smoke Grey Colour Synthetic Enamel Paint on all sides and Fitted with 1 No.6 Amp. SP MCB on anoized M.S. Channel ,1 No.bakelite fuse fitting with 06 Amp.NS 6 type HRC fuse ,01 No. copper neutral link,Bakelite TB of 4 terminal ,cable glands suitable for 2CX2.5sqmm size incoming and outgoing cable etc alongwith pvc pipe fixing on junction box half round GI Pipe OD 50mm for mounting the 120watt LED light upon gantry mounting of 02 no.bracket upon gantry size(95x95mm)and fixing of GI pipe complete with nut & bolts and washers. |
| 35 | Providing and fixing of 3 phase 415Volt AC lightining DB with canopy for outdoor installation rating 415Volt,200Amp.3-phase of size 1200X600X500 mm with hinged door and proper locking arrangement duly made of 16 SWG M.S. Sheet and painted with grey colour synthetic Enamel paint.The L.T. AC supply cubical should be fitted with 03 Nos.200Amp. copper bus bar (3 phase +Neutral),5 Nos. 32Amp.TPN MCB,12 Nos. 40 Amp.DP MCB,40Nos Link type Terminal block,cable glands any standrad make ,01 no. ampmeter,01 no.voltmeter having selector switch & 3 phase indication lamp with proper connections. etc.with internal wiring and then installation of ACDB on 01 meter long MS angle frame structure after due fabrication with help of scrap M.S.Angles to be provided by department free of cost and grounting of legs of the M S frame with C.C. mixture and painting of M.S. Angle frame with Synthetic Enamel paint. |
| 36 | Laying of 2C/4C*2.5sq mm size control cable from LT ACDB cubical to various junction boxes for Switchyard Lighting through excavated trench of suitable size covering the cables with river sand and brick lining along and over the cable, then back filling & levelling of the trench cover after laying of cables. |
| 37 | Laying of 3.5*95sq mm size LT Power cable from LT ACDB cubical to Main ACDB for Switchyard Lighting through 50 cm below the ground level after excavation of trench of suitable size covering the cables with river sand and Ist class brick lining along and over the cable, then back filling & levelling of the trench cover after laying of cables including termination of cable on both sides with crimping of Lugs. |
| 38 | Laying of 2C/4C*2.5sq mm size control cable from LT Lighting junction box to LED street light fitting by clamping with suitable M.S. strip clamp with proper dressing. |
| 39 | Safe carriage of various items like as Galvanized sub-station structure parts ,33KV C.B. , 33KV CT, 33KV PI, 33KV Isolater and Earthing rod 40 mm etc. from various S/S under ETC Gorakhpur to 132KV S/S Shatrughanpur,distance around 50KM (Approx) using private truck including loading at various substation and unloading at 132KV S/S Shatrughanpur using hydra with required manpower,T&P in scope of contractor. |
| 40 | Details of Supply |
| 41 | PART-B SUPPLY |
| 42 | Manual Co2 fire Extinguisher (9 Kg) |
| 43 | Manual Co2 fire Extinguisher (22.5 Kg) |
| 44 | Portable AFF mechanical foam type fire extinguisher complete with accessories trolly mounted 45/50 litre capacity |
| 45 | 40MM Electrod 3 meter long |
| 46 | 40 MM Earthing Mat |
| 47 | 50*6 mm MS Flat |
| 48 | 25*6 mm MS Flat |
| 49 | 33kV CT Clamp for Twin Panther |
| 50 | 33kV Isolater clamp for Twin Panther |
| 51 | 33kV C.B. clamp for Twin Panther |
| 52 | PG Clamp Moose to Panther |
| 53 | GI perforted cable tray (75 mm) |
| 54 | PG Clamp Panther to Panther Please Enable Macros to View BoQ information |