| 1 | Dismantling and cutting of MS cable drums into pieces shall be carried out as part of scrap disposal, as per the scope of work and as directed by the EIC.Shifting of scrap shall be treated as a separate item.(Refer Sec VI (MNC),Clause No.35) |
| 2 | Shifting of Electrical equipment/cable drums of various sizes including loading and unloading/Shifting of electrical/telephone items from IGCAR and hand over to service centres (upto chennai limit) or vice versa.(Refer Sec VI (MNC), Clause No.31). |
| 3 | Heavy Electrical equipment/cable drums (more than 500 kg and upto 5 Tons) within a distance of 1 kM |
| 4 | Equipment/cable drums weighing upto 100 kgs for a distance more than 500 mtrs and upto a distance of 5 kms. |
| 5 | Equipment/cable drums weighing upto 100 kg within a distance of 500 mtrs. |
| 6 | Equipment/cable drums weighing more than 100 kgs and upto 500 kg within a distance of 500 mtrs. |
| 7 | Heavy Electrical equipment/cable drums (more than 500 kg and upto 5 Tons) within a distance of 5 kM |
| 8 | Inspection and testing of cables of various voltage ratings coiled on drums shall be carried out as per the scope of work specified in Section VI (MNC), Clause No. 24. |
| 9 | 33/11 kV HT cables |
| 10 | 1100 V LT cables |
| 11 | Painting of cable drum with one coat primer(red oxide) alone as per detailed specification & directed by the Engineer-in-charge.(refer Sec VI(MNC). Clause No. 10.4 |
| 12 | Numbering of electrical equipments in following size and shape with synthetic enamel paint of different background colours, letter colour & size of letter as directed by Engineer in Charge (Refer Sec VI (MNC), Clause No.10.3). |
| 13 | within 200mm dia/225 X 100mm area |
| 14 | Clearing Heavy jungle area including removal all unwanted plants, branches, twigs, wild growth, trees and saplings of girth upto 30cm, uprooting of rank vegetation etc. complete, and disposing the same 100metres away by manually or burning them without disturbing other areas etc., complete all as directed by the EIC. The useful firewood if any, shall be cut and stacked at a place (with 100metres lead) as directed by the Engineer-in-Charge. Contractor must inform the Engineer-in-charge and prior permission shall be obtained from EIC before burning the wild growth. (Refer Sec VI (MNC), Clause N |
| 15 | Rewinding of one number 33/11/1.1 kV grade stranded aluminium conductor cable of the following sizes after removing it from the existing cable drum; checking the healthiness of the cable using an insulation resistance tester; quantifying the remaining cable length; and labelling all relevant details on the drum, all as per the detailed specifications and directions of the Engineer-in-Charge. |
| 16 | 33kV grade 400 sq.mm |
| 17 | 11kV grade 400/185 sq.mm |
| 18 | 1.1kV grdae 3/3.5/4core X Upto 25 sqmm OR up to 14 Core Control cable OR up to 20 pair telephone cable. |
| 19 | 1.1kV grade 3/3.5/4Core X above 25 & up to 120 sqmm OR above 14Core and up to 37 Core Control cable OR above 20pair and up to 200 pair telephone cable. |
| 20 | 1.1kV grade 3/3.5/4Core X above 120 & up to 240 sqmm |
| 21 | 1.1kV grade 3/3.5/4Core X above 240 & up to 400 sqmm |
| 22 | Collecting of scrap items and shifting more than 1 km and up to a distance of 5 kms. Measurement will be done on volume basis (Refer Sec VI (MNC), Clause No.28). |
| 23 | Servicing and overhauling of Battery operated E-Truck including supply and replacement of all spares as detailed in the scope of work. (Refer Section V)Note: 1. The Battery Operated E-Truck is Jost'S Make; Model: JOTRUCK.2. The spares shall be supplied by the OEM |
| 24 | Supply and installation of lead acid batteries as per scope of work (Refer Section V) |
| 25 | 12V, 150Ah |
| 26 | Supply and Replacement of the 2 feet 14Watts T5 Fluorescent lamp in Light fixture |
| 27 | Supply and installation of Knob type panel lock by replaciong existing damaged/broken panel locks at various panels/st.light timer boxes as detailed in the scope of work. |
| 28 | Supply, transportation, installation, testing and Commissioning of the following type of Wall (surface) mounted luminaires. (Refer Sec VI, Clause No.16.1). - Catalogue No : WT202W LED6S CW PSU S2 PC or equivalent and Lamp Type LED |
| 29 | Supply, Installation, Testing and Commissioning of following area lighting luminaries on Metalic poles of height from 2.5 M to 4 M as per per the detailed specification. (Refer Sec VI, Clause No.16.1). - Catalogue No : LPTO-40-CDL and Lamp Type LED |
| 30 | Supply and Installation of MS Brackets, Supports, Frame work, Clamps, Base Channels, etc. fabricated out of angle / Channel / Rods etc. The rate quoted shall include the cost of fabrication / welding, cleaning and painting/ galvanising as follows including supply of required, fasteners, nuts, washers, etc.(Refer Sec VI, Clause No.11). |
| 31 | MS fabrication 1 coat primer & 2 coats synthetic enamel paint |
| 32 | Chipping and plastering of RCC Trench/Floor up to 0.2 cu.mtr size for the embedment of MS channel/ edge angle as per the scope of work. |
| 33 | Supply, installation, testing and commissioning of the following SDFU with factory made enclosure with 3Nos Fuse links on MS frame work as per the scope of work. (MS item will be measured separately). (Refer Sec VI, Clause No.14.1). |
| 34 | SDFU TPN 125A, DIN FUSES with 3Nos 125A HRC fuse links, Open Execution FN Sheet steel enclosure FN Cat No:SK90486 |
| 35 | Supply and Installation of 3.75m Area lighting poles with Hammer tone finishing (Pedestal type). (Refer Sec VI, Clause No.13.3 & 13.4). |
| 36 | Supply and embedment Post top Lantern pole including Cast Aluminium Junction Box with FRP cover as per the drawing No: IGC/ESD/2021/6001/1-R1. 3.75mtr 50NB GI pole with Hammer tone painting, cable entry pipe, cable termination arrangements etc. including providing of 1:4:8 mudmat and 1:3:6 foundation PCC conforming to the detailed specification 1mtr 16mmDia SS rod with SS wire (2 runs) equivalent to 8SWG and as per Drawing No. IGC/ESD/2021/6001/P2-R1. |
| 37 | Supply, transportation, installation, testing and commissioning of the following Sensors as directed by the Engineer-in-Charge. (Refer Sec VI, Clause No.16). |
| 38 | Occupancy & day light PIR sensor suitable for lighting load of 500W and coverage 7.0 mtr diameter. The unit Shall have provision to adjust ON time as well as day light level for switching ON. (Refer Sec VI, Clause No.16.3). |
| 39 | Supply and replacement of the following led driver unit in flood light fixtures, Model No : YDRV150ED8 – EDC-150S105SV-3004,860mAmps |
| 40 | Supply and replacement of the following led driver unit in Street light fixtures, Model No : YDRV3045P - LT-30W-45W-PRG-CC-LED DRIVER PROGRAMMABLE Please Enable Macros to View BoQ information |