| 1 | (A) Civil Work: Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed (All kinds of Soil). |
| 2 | Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked material (All kinds of soil) Dredge Hole 1.50m to 3.00m |
| 3 | Sluice / Screen Chamber 1.50m to 3.00m |
| 4 | Dredge Hole 3.00m to 4.50m |
| 5 | Dredge Hole 4.50m to 6.00m |
| 6 | Dredge Hole 6.00m to 7.50m |
| 7 | Supply & laying of stone soling in horizontal on level. |
| 8 | Providing and laying in position cement concrete of specified grade including curing butexcluding the cost of centring and shuttering. All work upto plinth level with: (1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 9 | Reinforced cement concrete work in well-steining including curing but excluding the costof centering, shuttering, finishing and reinforcement, with (1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 10 | Well sinking including supply of well sinkers, assistant well sinkers, skilled labour and all other types of labourers,supply of E.C bags filled with sand for loading including stitching, loading / unloading , providing of plateform for loading, removal and disposal of loading material and scaffolding charges and cost of material involved at site for work (complete job) all told |
| 11 | Reinforcement for RCC work incl. Straightening cutting, bending, placing in position and binding all complete (Thermo Mechanically Treated Bars). |
| 12 | Centering and shuttering incl. Strutting, propping etc and removal of form work for:- |
| 13 | Foundation, footings, basis of columns etc, mass concrete. |
| 14 | Suspended floors, roofs, landings, balconies and access platform. |
| 15 | Walls (any thickness) incl. Attached pilasters buttresses, plinth and string courses. |
| 16 | Edges of slab and breaks in floors in walls (under 20Cm wide). |
| 17 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 18 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 19 | Well Steining and Curb portion |
| 20 | Extra for shuttering in circular work (20% of respective centering and Shuttering items) |
| 21 | Brick work with common burnt clay F.P.S.(non-modular) bricks of class designation 75 in foundation and plinth in Cement mortar 1 :4 ( 1 cement : 4 fine sand) |
| 22 | Extra for brick work in superstructure above plinth level upto floor V level. (By manual means) |
| 23 | 12 mm cement plaster of mix 1:4 (1 cement : 4 coarse sand) |
| 24 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade New work (two or more coats) over and including priming coat with cement primer |
| 25 | Structural steel work welded in built up section trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete |
| 26 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5 m long wire springs manufacture from high tensile steel wire of adequate strength confirming to IS 4454 part1 and M.S. top cover of required thickness for rolling shutters. (80x1.25 mm M.S. laths with 1.25 mm thick top Cover) |
| 27 | Providing corrugated G.S.Sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G. I limpet washers or with G. I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.63mm thick with zinc coating not less than 275gm/sqm |
| 28 | Providing ridges or hips of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G. I. limpet and bitumen washers complete. 0.63mm thick with zinc coating not less than 275gm/m2 |
| 29 | Providing & Fixing SMP coated sheets for chajja work fixed to supporting structure including cost of J bolts, nuts bolts and limpet washels etc Complete job. |
| 30 | Providing & Fixing Plain colored iron sheets in eaves boards 250mm wide etc including cost of J bolts, nuts bolts and limpet washels etc Complete job. |
| 31 | Providing and fixing C.l. sluice valve (with cap) complete with bolts, nuts, rubber insertions, tail pieces etc. 100 mm dia (Approved make, ISI branded) as per directions of Engineer-In-Charge(Complete job). |
| 32 | Providing and fixing C.l. sluice valve (with cap) complete with bolts, nuts, rubber insertions, tail pieces etc. 150 mm dia (Approved make, ISI branded) as per directions of Engineer-In-Charge(Complete job). |
| 33 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required: In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 34 | Supply installation Testing and commissionig of MS C class 100 mm 5.4 mm thick flanged pipe rising main pipe including all miscellenous Tees, bends, elbows, flanges, ofset gaskets etc. duly welded with each other by using advani electrodes along with structural support required for its successful commissioning as per directions of Engineer-In-Charge(Complete job). |
| 35 | Supply installation Testing and commissionig of MS C class 150 mm 6.4 mm thick flanged pipe raising main pipe conferming ofo IS 1239 including all miscellenous Tees, bends, elbows, flanges, ofset gaskets etc. duly welded with each other by using advani electrodes along with structural support required for its successful commissioning as per directions of Engineer-In-Charge(Complete job). |
| 36 | Carriage of Materials by Mechanical Transport from Source to site of work: - |
| 37 | Stone soling from Athwajan Avg. 12kms |
| 38 | Stone Agg. 40mm size from Athwajan 12Kms. Avg |
| 39 | Stone Agg. 20mm size from Athwajan 12Kms. Avg |
| 40 | Sand from Ganderbal Avg. 18kms |
| 41 | Cement & Steel Avg. 6kms |
| 42 | Bricks Avg.25km |
| 43 | (B) Electro Mechanical Equipments: 1. Raw Sewage Sump at 2.21 MLD STP Rajbagh: Supply, installation, testing and commissioning of submersible type pump sets with motors, SS guide Rails, submersible cable ( Power cable, control cable, instrumentation cable each 100 meter length) ,ultrasonic level transmitter(0-10 Mtr),soft starter panel, duck foot pedestal etc Type of pump: Non clog centrifugal volute type sewage submersible Pumps Type of pump: Non clog centrifugal volute type sewage submersible Pumps Capacity= 125 M3/Hr Head = 12 meters or above Motor rating = 12.5 H.P 1450 rpm |
| 44 | Providing fitting and testing of MS rising main 200 mm dia 5.4 mm thickness from IPS to main sewage sump of STP. The job includes P/F of MS bends, fabrication of easy bends ,flanges, rubber gaskets nut and bolts etc for successful execution of work at site. |
| 45 | Providing fitting and testing of 150 mm dia sluice valves. |
| 46 | Providing fitting and testing of 150 mm dia Non return valves. |
| 47 | Providing ,fabrication erection of MS working plate form over the main pumping sump. The MS frame is to be fabricated out of ISMB, ISMC and angle iron. The frame is to be covered by MS chequered plate 6mm thick and the openings at the requisite places are to be fabricated with hinge mechanism for the lifting and lowering of the pumping units during maintenance .Fabrication and erection of MS ladder 6 mtr long to be erected inside the sump.The details of ISMB, ISMC, Angle iron and chequered plates are as under.i. ISMB 150=10 RM.@ 15Kg/RM=150 kgii. ISMC 100=10 RM @ 9.56Kg/RM=95.6 kgiii. ISA 65=30 RM @5.80Kg/RM=174 kgiv. Chequered Plate 6 mm=20 [email protected]/SM= 942kgTotal weight=1361.6 kg |
| 48 | Over head gantry comprising of M.S framed structure over Raw Sewage Sump 2ton (01 no’s) |
| 49 | Providing fitting and testing of MCC panel with changeover switch 160 ampere, 100 Ampere TPN Al bus bars s, MCCB 100 Amp (02 no’s) ,digital multifunctional meter. |
| 50 | Providing fitting and testing of 35 MM square 3.5 core Aluminium cable from servo stabilizer to panel. |
| 51 | 2. IPS at Aramwari: Supply, installation, testing and commissioning of submersible type pump sets with motors, SS guide Rails, submersible cable ( Power cable, control cable, instrumentation cable( each 100 meter length) ,ultrasonic level transmitter(0-10 Mtr),soft starter panel, duck foot pedestal etc Type of pump: Non clog centrifugal volute type sewage submersible Pumps Type of pump: Non clog centrifugal volute type sewage submersible Pumps Capacity= 87 M3/Hr Head = 12 meters or above Motor rating = 10 H.P 1450 rpm. |
| 52 | Providing fitting and testing of 100 mm dia Sluice valves. |
| 53 | Providing fitting and testing of 100 mm dia NRV |
| 54 | Providing fitting and testing of 100 mm dia GI pipe. |
| 55 | Over head gantry comprising of M.S framed structure over Raw Sewage Sump 1 ton (01 no’s) and chequred plate cover over sump. |
| 56 | Providing fitting and testing of copper wound servo stabilizer 25 KVA for input voltage of 156 Phase to phase and output voltage 415 volts phase to phase. |
| 57 | Providing fitting and testing 25 KVA D.G.set confirming to CPCB IV guide lines along 50 Sq mm 3.5 core Al cabling from D.G set to main MCC panel, earthing as per OEM recommendations. The job includes P/L of RCC foundation block as per OEM recommendations along with CGI roofing |
| 58 | Providing fitting and testing of 63 KVA HT/LT substations including ST poles, ABC conductor, ,prodigy meter, and all other allied accessories required for successful commissioning. The job also P/L of single core aluminum conductor 50 Sq mm from LT/HT substation to main control panel The necessary clearance for installation /Commissioning is in contractors scope of work along with earthing of substation as per IEE rules. |
| 59 | Providing fitting and testing of 25 MM square 3.5 core Aluminium cable from servo stabilizer to panel. |
| 60 | Providing fitting and testing of MCC panel with changeover switch 100 ampere, 63 Ampere TPN Al bus bars s, MCCB 63 Amp (02 no’s) ,digital multifunctional meter. |
| 61 | Illumination of the pump station. Please Enable Macros to View BoQ information |