| 1 | Supplying, fitting & fixing fire resistant door frame conforming to IS:3614, tested and certified as per laboratory approved by Engineerin- charge, of section 143 x 57 mm having built in rebate made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based concrete mix, suitable for mounting 120 minutes fire rated door shutters. The frame is fitted with intumescent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with back plate bracket and anchor fastener of approved size and make. Rubber door silencers should be provided on striking jamb.Supplying, fitting & fixing fire resistant Door leaf of 46 mm thick fully flush double skin glazed fire resistant door shutters with or without vision lite, of 120 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 18 SWG G.I. sheet (zinc coating notless than 120 gm/ m2) duly filled heat-resistant phenolic resin bonded insulation material (honeycomb craft) and fixing with necessary stainless steel ball bearing hinges of approved make. For pair of doors astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufacturer recommendation with a beeding and screw from inside. The glass should be 6mm clear borosilicate fire rated glass of relevant rating.All door and frames shall be finished with polyurethene aliphatic grade paint of approved colour including applying a coat of approved brand fire resistant primer. The door leaf and frame shall have passed minimum 250 hours of salt spray test. Rate should include supply and installation complete as per direction of Engineerin- charge.2 hour Fire rated door single leaf of size (1200 mm x 2180 mm). |
| 2 | At Ground Floor. |
| 3 | At 1st Floor. |
| 4 | At 2nd Floor. |
| 5 | At 3rd Floor. |
| 6 | At 4th floor. |
| 7 | At 5th floor. |
| 8 | Supplying, fitting & fixing Surface mounted Crash Bar/ panic Bar of touch pad style, made of heavy duty cast iron/ steel body & latches with SS, BHMA certified & conforming to ANSI A 156.3 for grade-1 (3 hours fire rated) and suitable for surface mounting to wooden/hollow metal/ Al framed door withopening upto 900mm, with maximum operating force 6 kg for unlocking easily & outwardly during emergency, complete in all respect as per direction & satisfaction of Engineer-in-Charge. For door opening 900. |
| 9 | Supplying, fitting & fixing Surface mounted overhead Door Closer for 2 hour fire rated doors, of size EN-4 for leaf width upto 950/ 1100mm weighing maximum 60/ 80 kgs, CE certified, marked & conforming to EN 1154-2003 ofapproved quality of reputed brand, complete as per direction & satisfaction of Engineer-in-Charge.For leaf width upto 950mm. |
| 10 | Supplying & application of chemical for post installed rebar connection by using ETA approved for seismic criteria in rebar connection, including drilling hole to the required depth by rotary hammer drill, cleaning with brush & jet of clean air, filling chemical using serrated nozzle to eliminate mixing error & in a voidless manner including charges for all tools & plants. Application to be designed for post - installed rebar as per EC2/TR023 or relevant tested & accepted design guidelines & the design documents to be furnished by the manufacturer. The chemical should have ETA approval for seismic criteria of rebar fixing which should be furnished by manufacturer. The installation & the setting instructions should be strictly followed as per manufacturer's specification as per approved by EIC prior to drilling along with the post - installed rebar embedment design report. The existing concrete member should be scanned using rebar scanner to avoid hitting existing reinforcement in concreteduring drilling. Cost of post installed rebaring application with chemical as specified for 12 mm dia per cm of depth. |
| 11 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. For works in foundation and upto roof of ground floor/upto 4 m. Other manufacturers not specified. |
| 12 | At Ground Floor. |
| 13 | At 1st Floor. |
| 14 | At 2nd Floor. |
| 15 | At 3rd Floor. |
| 16 | At 4th floor. |
| 17 | At 5th floor. |
| 18 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. Pakur Variety. |
| 19 | At Ground Floor. |
| 20 | At 1st Floor. |
| 21 | At 2nd Floor. |
| 22 | At 3rd Floor. |
| 23 | At 4th floor. |
| 24 | At 5th floor. |
| 25 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns,lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor). 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge. |
| 26 | At Ground Floor. |
| 27 | At 1st Floor. |
| 28 | At 2nd Floor. |
| 29 | At 3rd Floor. |
| 30 | At 4th floor. |
| 31 | At 5th floor. |
| 32 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor). [Excluding cost of chipping over concrete surface]. With 1:6 cement mortar. 20 mm thick plaster. |
| 33 | At Ground Floor. |
| 34 | At 1st Floor. |
| 35 | At 2nd Floor. |
| 36 | At 3rd Floor. |
| 37 | At 4th floor. |
| 38 | At 5th floor. |
| 39 | Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand. (1.5 mm thick). |
| 40 | At Ground Floor. |
| 41 | At 1st Floor. |
| 42 | At 2nd Floor. |
| 43 | At 3rd Floor. |
| 44 | At 4th floor. |
| 45 | At 5th floor. |
| 46 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. One Coat. Water based interior grade Acrylic Primer. |
| 47 | Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats). Standard Quality. Please Enable Macros to View BoQ information |