| 1 | Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed. |
| 2 | Demolition of brick work or stone/boulders masonary, built in cement mortor including all quoins, arches pillars, etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and directed. |
| 3 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc, laid, bedded, jointed and pointed in any mortar complete all as specified and directed by Engineer-in-charge. |
| 4 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing rubbish off premises complete all as specified and directed. |
| 5 | Taking down chowkhats with shutter (without taking off shutters from the frame) area not exc. 1.50 Sqm each complete all as specified and directed. |
| 6 | Taking down chowkhats with shutter (without taking off shutters from the frame) area exc. 1.50 Sqm but n.exc 4.00 sqm each complete all as specified and directed. |
| 7 | Taking down shutters of any description exc 1 Sqm and not exc. 2 Sqm each complete all as specified and as directed by Engineer-in-charge. |
| 8 | M&L for Brick work with sub class ‘B’ old size burnt bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-charge. |
| 9 | S&F Pressed steel frame for doors of size 105 x 60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete all as specified and directed. |
| 10 | S&F Pressed steel frame for doors of size 125 x 60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete all as specified and directed. |
| 11 | M&L for cement concrete type C-1, (1:3:6) using 20mm graded aggregate as in bed block or filling of chowkhats including necessary form work complete all as specified and directed. |
| 12 | S&F for 30mm thick flush shutter solid core construction with block board core & ply wood face panels, commercial type on both faces complete all as specified and directed by Engineer-in-charge. |
| 13 | M&L 35mm thick factory made glazed and skeleton shutters of 2nd class HW with partially panel shutter open rebated and prepared to receive glass / gauze etc edges or framing plain chamfered or rounded fitted with cut or mitred beads for securing glass etc as specified in SSR Part-1 section 8.24 (a) complete all as specified and directed. |
| 14 | S&F 35mm thick plain framed panelled door shutter, factory made (any number of panels) of 2nd class hard wood with lock rail and panels of 9mm thick BWP commercial ply or 12mm thick veneered particle board with commercial veneering on both faces including 2nd class hard wood kail beading 20mm wide tapering from 10mm to 5 mm on one side of shutter & fitted to chowkhats. The size of rail and style shall be as per IS –1003 (Part-I) (wood shall be kiln seasoned and chemically pressure treated) complete all as specified and directed. |
| 15 | S&F factory made solid PVC door frame of size 50mm x 47mm made out of 5mm thick plain colour PVC sheet reinforced with MS square tube complete all as specified & shown in relevant drawing of item No. 08095 in MES Schedule (Part-II) and directed by Engineer-in-Charge. |
| 16 | S&F 30mm thick factory made solid PVC moulded door shutter with particle board core with 5mm thick PVC moulded sheet on the front face and 5 mm thick PVC plain colour sheet on back face complete all as specified and directed by Eng-in-charge. |
| 17 | M&L for in repair to aluminium door/window of any size/any description, taking off from present position and refixing in the same position after tightening, easing/change the section as required, including fitting the rubber packing aluminium snap beading resetting floor/hydraulic door closer/spring etc complete all as specified and directed. |
| 18 | M&L 3mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane including painting / oiling to new putty to match with the existing/new surfaces, complete all as specified and as directed. |
| 19 | S&F 3 mm thick figured (frosted) glass, ordinary quality and glazing with oil putty/wooden beads in square not exceeding 0.5 square metre in each pane complete all as specified and directed. |
| 20 | S&F 150 mm long stainless steel barrel tower bolts of extruded section (ISI marked) complete all as specified and directed by Engineer-in-charge. |
| 21 | S&F in repair 150 mm long stainless steel barrel tower bolts of extruded section (ISI marked) complete all as specified and directed by Engineer-in-charge. |
| 22 | S&F in repair 200 mm long stainless steel barrel tower bolts of extruded section (ISI marked) complete all as specified and directed by Engineer-in-charge. |
| 23 | S&F 300mm stainless steel sliding door bolts, bolt type with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed. |
| 24 | S&F in repair 250mm stainless steel sliding door bolts, bolt type with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed. |
| 25 | S&F stainless steel cast type anodised of size 150mm size, complete all as specified and directed. |
| 26 | S&F in repair stainless steel cast type anodised of size 150mm size, complete all as specified and directed. |
| 27 | S&F 100mm long stainless steel Butt hinges fixed complete all as specified and directed. |
| 28 | S&F 150mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed. |
| 29 | S&F in repair 150mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed. |
| 30 | S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or stainless steel wire staples complete all as specified and directed by Engineer-in-Charge. |
| 31 | S&F in repairs stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or stainless steel wire staples complete all as specified and directed by Engineer-in-Charge. |
| 32 | M&L for glazed ceramic tiles (coloured) 450mm x 300mm x 7mm thick on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick rendering in cement & sand mortar (1:4) including necesary cutting as per site requirment complete all as specified and directed by Engineer-in-charge. |
| 33 | M&L Non skid coloured ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but n.exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match with and including 15mm thick screed bed in cement mortar (1:6) for laying floor finishes complete all as specified and as directed. |
| 34 | M&L for non skid ceramic coloured tiles 7 to 8mm thick (square / rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar (1:4) complete all as specified and directed by Engineer-in-charge. |
| 35 | All as per item No 34.00 (here-in-before) abvoe but as in skirting over 10mm thick backing coat in CM (1:3) complete all as specified and directed. |
| 36 | M&L for machine cut Kota stone slab flooring 18 to 20mm thick (minimum size 550mm x 550mm or size as directed) laid over & including screed bed or bedding layer of 20mm thick in CM (1:6) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engineer-in-charge. |
| 37 | M&L for machine cut kota stone slab 18-20 mm thick in riser of steps, skirting, dado and pillar laid over and including cement plaster 15 mm thick in CM (1:3) laid and jointed with pigment to match the shade of slab including rubbing and polishing complete all as specified and directed. |
| 38 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations etc complete all as specified and directed. |
| 39 | M&L for 16-18mm thick Granite (of any type) work (table rubbed and polished) for Shelves (veneering to wall) including 15mm thick plaster in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed. |
| 40 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM in (1:4) finished fair and even external surface complete all as specified and directed. |
| 41 | M&L rendering 15 mm thick in CM 1:6 on brick masonry surfaces or on other than fair faces of brick masonry finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |
| 42 | M&L rendering 15 mm thick in CM 1:6 on brick masonry surfaces or on other than fair faces of brick masonry finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |