| 1 | S&F the LED light fitting 1x10 watt 230 Volt, 6500k slim body with reflector,drivers,LEDs surface & wall mounted LED batten anodized AL housing complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed including taking down old fitting.Make-Jaquar Cat No BTI -WHT-LGL01X010XN/ Phillips Cat No BN012CLED10CWPSU/Crompton Cat NO LCTLN-10-65-NW /Bajaj BCLSB10WH. |
| 2 | S&F the LED light fitting 1x20 watt 230 Volt, 6500k slim body with reflector,drivers,LEDs surface & wall mounted LED batten AL housing complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed including taking down old fitting.Make- Jaquar Cat No BTI -WHT-LGL01X020XN/CG Cat NO CCS-100-20-65-HL2-DP-NWH /Havells LUMILINENEOOBS20WLED865SPCSSIND |
| 3 | S&F the LED light fitting 1x20 watt 230 Volt, 4000k slim body with reflector,drivers,LEDs surface & wall mounted LED batten AL housing complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed including taking down old fitting.Make- Jaquar Cat No BTI -WHT-LGL01X020XW/CG Cat NO CCS-100-20-65-HL2-DP-NWH /Havells LUMILINENEOOBS20WLED865SPCSSIND |
| 4 | S&F the LED light fitting 1x40 watt 230 Volt, 6500K slim body with reflector,drivers,LEDs surface & wall mounted LED batten CRCA housing complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed including taking down old fitting.Make-Bajaj cat - DAWN AL 40W CWPD/Crompton Cat NO CCS-100-40-65-HL2-DP-NWH /Havells DURABS40WLED865SPCSS |
| 5 | S&F the LED light fitting 1x40 watt 230 Volt, 4000K slim body with reflector,drivers,LEDs surface & wall mounted LED batten CRCA housing complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed including taking down old fitting.Make-Bajaj cat - DAWN AL 40W CWPD/Crompton Cat NO CCS-100-40-65-HL2-DP-NWH /Havells DURABS40WLED865SPCSS |
| 6 | S&F LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed/surface type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete and including taking down old fitting Make- Havells/Bajaj/CG |
| 7 | S&F Electronic LED FTL rod 4 Feet capacity 20W complete and including taking down old tube rod complete and including taking down old fitting Make- Havells /Bajaj/CG . |
| 8 | S&F in repair switch piano flush button type 6 Amp 240 Volt one way single pole complete all as specified. |
| 9 | S&F in repair of switch piano flush button type 15 Amp 240 Volt one way single pole complete all as specified. |
| 10 | S&F in repairof bell push button type 5/6 Amp 240 Volt one way single pole complete all as specified. |
| 11 | S&F in repair Socket outlet 2 in 1, 3 pin, 5A complete all as specified. |
| 12 | S&F in repair Socket outlet 2 in 1, 5 pin, 15/16A complete all as specified. |
| 13 | S&F in repair Switch socket combination 2 in 1, 5 A flush type complete all as specified and directed. |
| 14 | S&F in repair switch socket combination multi purpose 5/6 Amp /16 Amps, 5 in1, flush type complete all as specified and directed. |
| 15 | S&F in repair electronic double space rotary step fan 5 speed socket type regulator 120- 280 Volts complete all as specified. |
| 16 | S&F in repair of switch Modular switch 1 way 10A,1 module 240 volts complete |
| 17 | S&F in repair switch Modular switch 1 way 15A,1 module 240 volts complete |
| 18 | S&F in repair socket outlet Socket, 6A - 2/3 pin combined 2 module 240 volts complete all as specified |
| 19 | S&F in repair socket outlet Socket, 6/16A - 2/3 pin combined 2 module 240 volts complete all as specified |
| 20 | S&F in repair Fan step regulator, 120W - 2 module 240 volts complete all as specified |
| 21 | S&F in repair ceiling rose surface bakelite 3 terminals 65 x 50mm |
| 22 | Taking down copper/aluminum pt wiring (light fan, socket or power) complete including fittings such as switch, sockets, c/rose, pendents, regulators, sockets, light fittings, wooden boards, bell push, call bell, regulators etc (credit scheduled for above items should be made as per condition separately) and making good to disturbed wall and surface complete all as specified. |
| 23 | M&L for concealed conduit Point wiring with 1.5 Sq mm multistranded copper conductor FRLSH PVC insulated and unsheathed cable ISI Marked & drawing in and including non-metallic PVC conduit 20 mm bore medium grade & ISI marked on walls/ceilings/steel frame structure (with necessary arrangement as required at site) including cutting chasing for wiring , pinning in making good & finishing of disturbed surfaces,white wash matching with the existing surface colour & including all conduit fittings, clamps, gutties etc. Point to be for one light controlled by one switch , bell point controled by one bell point and fan point or one fan point controlled by one switch and regulator each including provision of new pressed steel terminal boxes not less then 1.6 mm thick; with provision of new 3 mm thick plastic laminated sheet of and PVC insulated stranded copper continuous earth wire 1.5 Sqmm size FRLS to common earth and connecting to earth dolly, complete all as specified and directed. (Switch/socket, regulators shall be measured & paid for separately). Note- All the wires will be used with approved colour coding and as directed by Engr in-charge. |
| 24 | Description all as per above item No 23 but for 2 pin socket outlet 5 amp on the same board contraolled by separate switch complete all as specified. |
| 25 | Description all as per above item No 23 but for 2 pin socket outlet 5 amp independent but not below the main board In the same vertical plane complete all as specified. |
| 26 | Description all as per above item No 23 but with 2.5 sqmm copper conductor for 15 amp switch socket outlet combination n1. including 1.5 sqmm copper earth wire complete all as specified.. |
| 27 | S&F LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified. |
| 28 | S&F of Flameproof cum Waterproof LED Bulk Head light fitting of 15W, IP66 protection of Cast Aluminum alloy material and Heat and Impact resistance toughen 'A' clear glass having Anti corrosive epoxy powder coated finish complete with all accessories pre wired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified. |
| 29 | Supply and fix in repair of PVC insulated and FRLSH PVC Round Sheathed, Copper Conductor (flexible) industrial cable of size 0.5 Sqmm 2 core , 1100 Volt, conforming to IS 694 connecting up the light fittings & fans all as directed. |
| 30 | Supply and fix in repair of PVC insulated and FRLSH PVC Round Sheathed, Copper Conductor (flexible) industrial cable of size 1.5 Sqmm single core , 1100 Volt, conforming to IS 694 all as directed. Note - Wire will be fixed in the existing PVC conduit/Casing capping and cost of making good shall be included in items rates. |
| 31 | Supply only the 3 mm thick 75 x 100 mm size laminated sheet cover ISI mamrked including cutting of holes for mounting, 4 switches, sockets, fan regulator etc complete all as specified and directed and including taking down old fitment of existing sheet. |
| 32 | Description all as per item No 31 but 100 x 100 mm laminated sheet cover with 04 Nos screw with washers cutting of 6 single switch module complete. |
| 33 | Description all as per item No 31 but 100 x 150 mm laminated sheet cover with 04 Nos screw with washers cutting of 8 single switch module complete. |
| 34 | Description all as per item No 31 but 150 x 200 mm laminated sheet cover with 04 Nos screw with washers cutting of 10 single switch module complete. |
| 35 | Description all as per item No 31 but 250 x 200 mm laminated sheet cover with 04 Nos screw with washers cutting of 12 single switch module complete. |
| 36 | S&F sub-main wiring with two single core FRLSH PVC insulated and unsheathed cable with stranded copper conductor of 2.5 Sq mm drawing in & including medium grade PVC conduit pipe 20 mm bore ISI marked with all accessories on walls and making good of disturbed surfaces including all conduit fittings, clamps, gutties etc and one additional earth wire of 2.5 Sq mm but green in colour for earth DBs and boxes with proper thimbles connecting up and taking down old submain wiring complete all as specified and directed.(Note : Two run of wire and one run of earth wire drown in PVC conduit of 20 mm dia shall be measured as one RM). |
| 37 | S&F sub-main wiring with two single core FRLSH PVC insulated and unsheathed cable with stranded copper conductor of 4 Sq mm drawing in & including medium grade PVC concealed conduit pipe 20 mm bore ISI marked with all accessories on walls and making good of disturbed surfaces including all conduit fittings, clamps, gutties etc and one additional earth wire of 4.0 Sq mm but green in colour for earth DBs and boxes with proper thimbles thimbles connecting up and taking down old submain wiring complete all as specified and directed,.(Note : Two run of wire and one run of earth wire drown in PVC conduit of 20 mm dia shall be measured as one RM). |
| 38 | S&F sub-main wiring with two single core FRLSH PVC insulated and unsheathed cable with stranded copper conductor of 6 Sq mm drawing in & including medium grade PVC concealed conduit pipe 20 mm bore ISI marked with all accessories on walls and making good of disturbed surfaces including all conduit fittings, clamps, gutties etc and one additional earth wire of 6.0 Sq mm but green in colour for earth DBs and boxes with proper thimbles thimbles connecting up and taking down old submain wiring complete all as specified and directed.(Note : Two run of wire and one run of earth wire drown in PVC conduit of 20 mm dia shall be measured as one RM). |
| 39 | S&F sub-main wiring with 4 Nos single core FRLS PVC insulated and unsheathed cable with stranded copper conductor of 10 Sq mm drawing in & including medium grade PVC concealed conduit pipe 25 mm bore ISI marked with all accessories on walls and making good of disturbed surfaces including all conduit fittings, clamps, gutties etc and one additional earth wire of 10.0 Sq mm but green in colour for earth DBs and boxes with proper thimbles thimbles connecting up and taking down old submain wiring complete all as specified and directed.(Note : Four run of wire and one run of earth wire drown in PVC conduit of 25 mm dia shall be measured as one RM). |
| 40 | M&L for sheet metal enclosure MCB DB, SPN, 240 volts, 12 way, double door type grouting in wall in CM, making good of disturbed surfaces and matching with existing and electrical connections complete. |
| 41 | Supply and fixing for sheet metal enclosure MCB DB, IP-43, SPN, 240 volts ,8 way, double door type grouted in wall in cement mortar 1:3 and making electrical connection, complete all as specified and directed and including taking down old DBs and take to schedule of credit. |
| 42 | Supply and fixing MCB SP, 6 to 32 Amps, 240 volts, 10 KA, 'C' Curve characteristics, including taking out old unserviceable MCB/Isolator, electrical connections and removal from the site complete all as specified and directed. |
| 43 | Supply and fixing MCB SPN,32 Amps, 240 volts, 10 KA 'C' Curve characteristics, including taking out old unserviceable Isolator & electrical connection and removal from the site complete all as specified and directed. |
| 44 | Supply and fixing MCB SPN,40 to 63 Amps, 240 volts, 10 KA 'C' Curve characteristics, including taking out old unserviceable Isolator & electrical connection and removal from the site complete all as specified and directed. |
| 45 | Supply and fixing in replacement of TPN Vertical Type Distribution Board, IP-43 protection, fitted with bus bars, neutral links, blanking plates (with out MCCB), 415 volts, 4 way double door type, grouted in wall in cement mortar 1:3 and making good of disturbed surface and matching with existing surface, complete all as specified and directed and including taking down old DBs and take to schedule of credit. |
| 46 | Supply and fixing in replacement of MCCB, 4P, rated current 63 Amp, breaking capacity 16/18 kA thermal magnetic type and making electrical connection, complete all as specified and directed and including taking down old mccb and take to schedule of credit. |
| 47 | Supply and fixing in replacement of MCCB, 4P, rated current 100 Amp, breaking capacity 16/18 kA thermal magnetic type and making electrical connection, complete all as specified and directed and including taking down old mccb and take to schedule of credit. |
| 48 | Supply and errection of Earth electrode 17.2 mm dia 3 mtr long of low carbon steel electrode with copper bonding of thickness 250 micron, Back-fill earthing enhancing compound type Carbon based compound conductive concrete type which has a resistivity of less than 0.12 Ohm Mtr as per Clause 14.5D of IEEE : 80 standard. Back-fill compound should be electronically conductive (Like in metals) and should not depend on moisture for conduction. Back-fill comound should be environment friendly & should be solidify when mixed with water and set like concrete and should not leach / diffuse into the ground. Back-fill compound shall not be mixed with any soil while pouring in the bore hole. Test Certificate as per as per IEC: 62561-7 for Back-fill compound shall be submitted along with the material including SS clamp to be provode both side complete all as specified Note - (i) Earth electrode should be applicable Standards IS: 3043, IEC 62561-2 & IEC 60364-5 and made of High Tensile steel rods copper bounded, High tensile strength,good electrical conduction & effective performance and suitable for all type of soil and provided minimum distance 3 Mtrs. (ii) Back-fill compound should be Compliance to the Standards IEEE: 80, IS-3043, BS 7430, IEC 62561-7, ANSI/NSF 60 Certification.(iii) Positive low resistance electrical connection to the earth. (iv) Does not contain hazardous chemicals.(v) Electronically conductive (like in metals) and is not dependent on moisture.(v) Provide the desire value of earth resistance as per required specified values and Test result to be provide of electrode. Made : OBO Betterman/ AXIS/ VTR |
| 49 | Taking down unsv earth continuity conductor of any type and size but S&F in replacement Earth continiuty conductor or main earthing lead fixed on wall on batten or recess or chases or buired in ground or drawn in conduit / pipe or fixed to wall up to test point / laying in below ground drown in GI tubing or any other indicated suituation for loop earthing etc, as required for galvanised iron wire 4 mm dia with proper saddles / spacer, screw etc, alll as specified and directed. |
| 50 | Description all as per above item No 49 but 25×4 mm galvanised iron strip . |
| 51 | Description all as per above item No 49 but 25×3 mm aluminium strip . |
| 52 | Description all as per above item No 49 but 20x3 mm copper strip |
| 53 | Taking down unsv any type and size of GI tubing and S&F for 40 mm bore galvanised steel water tubing medium grade with all fitting fixed to wall and ceiling or laid in floors complete all as specified and as directed. |
| 54 | Taking down unsv chamber of any type and size but M&L for earthing chamber of size 0.45 x 0.45x 0.45 m and 100 mm thick by PCC 1:3:6 type C1 with 20 mm graded stone chamber with RCC 1:2:4 type B1 in cover slab complete all as specified and as directed. |
| 55 | M&L for XLPE insulated heavy duty electric cable of size 16 Sqmm 4 core with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheather laying/fixed to wall/pole and including taking down old unserviceable cable complete all as specified and directed. |
| 56 | Taking out old/unsv/damaged PCC/steel pole complete with all accessories incl demolition of concrete with necessary excavation and earth work incl site clearance complete all as specified and as directed by Engr-in-charge |
| 57 | Supply,installation and erection in true vertical or to be planted as strut steel tubular swaged welded poles complete with MS base plate of 6mm thick of size 300mmx300mm at bottom duly welded and MS pole cap at top,poles made out of ERW MS tubing confirming ti IS1161 part-II, type 410 SP -31(9.0m long) including drilling of holes of required size and nos for fixing of cross arms/clamps, painting with one coat of red oxide primer and two coats of aluminum paint for expose surface and two coats of black bituminous paint for portion embedded in concrete, painting three black/white bands at lower portion of pole each of 300mm height at 300mm spacing, painting pole no. with black paint at suitable height complete all as specified and directed |
| 58 | M&L for plain cement concrete 1:4:8 type D2(Using 40mm graded crushed stone agg) as in foundation of poles and mass concrete complete all as specified |
| 59 | M&L for cement concrete 1:3:6 type C2((Using 40mm graded crushed stone agg) as in foundation of stays and coping around poles complete all as specified |
| 60 | M&L for Cross arms bracings, support, clamps and back plates fabricated from structural steel section including nuts, bolts, washers etc, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminum paint complete all as specified and directed by E-in-C. |
| 61 | M & L for shackle type porcelian vitreous white ,brown or green insulator including galvanised mild steel straps washers,insulator bolts,washers and nuts of size 100 mm height and 115mm dia for 1100 volts grade complete incl taking down old/unsv insulator any type |
| 62 | Supply, laying, jointing and testing XLPE insulated, PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system and conforming to IS : 7098 of 1995 and of size 3.5 core X 16Sqmm and laid in trenches/ducts/pipe or on poles complete all as specified and directed. |
| 63 | Description all as per above item No 67 but size 4 core X 10 sqmm |
| 64 | M&L Cleaning the existing exposed surfaces of steel tubular pole of 9.0 mtr long including cross arms, brackets, clamps etc and painting with two coats of aluminium paint marking five black & white bands at lower portion of pole, each 300 mm wide alternately and marking pole No. with yellow paint on black base at suitable height complete all as specified and directed by Engineer-in-Charge. |
| 65 | M&L for cement Painting of PCC pole 9.0/11.0 metre long, by applying one coat of cement colour after scraping / brushing and cleaning the rust on pole and street light bracket to painted with one coat of Aluminium paint. Cement colour will be done on pole above 1.5 metre height from ground level and balance 1.5 mtr from ground level will be painted by alternate layer of black and white enameled paint (30 Cms Each) Pole Nos shall be written on pole with black paint in yellow circle of 150mm dia, complete, all as specified and directed. |
| 66 | M& L for pin type ,porcelain,vitreous white brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut 150mm height,150mm dia for 11000 volts grade |
| 67 | Material and Labour restringing of LT ACSR OH line conductors up to permissible sag after dismantling the binding wires from insulators and jumper connections complete for the following and providing 4 wire only (three phase and neutral) with new aluminium conductor binding wire to insulators and Jumpers etc all as directed. |
| 68 | Trimming of tree branches around over head LT electric lines and cleaning 3 Mtrs from the line, removing cut materials ( tree branches) from site and stacing properly where directed. Grith of branch ( where cutting took place) not exceeding 50 mm complete all as specified. |
| 69 | Suppy and fix PVC spacers 4 way for LT OH line 1100 volts grade with necessary screw nuts bolts etc complete all as directed to prevent the lines touching each other on heavy wind as a preventive arrangment to existing system including removal of unservicable spcers complete all as specified and as directed. |
| 70 | Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable, foundation etc, and getting out in hard /dense soil complete all as specified and directed. |
| 71 | Returning filling in including spreading, leveling, Watering and well ramming in layers not exceeding 25cm complete all as specified and directed. |
| 72 | Removing excavated surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. |
| 73 | M & L for Sand cushioning trenches using fine sand to under ground cable, laid in two layers 15cm before laying the cable & 8cm after laying the cable complete all as specified and directed. |
| 74 | Material and labour for laying bricks 'B' class over a cable (Width wise) old laid dried complete all as specified and directed. |
| 75 | Servicing to LT panels/Feeder pillar boxes comprising MCCBs/change over switches metering eqpt etc. as incomming/outgoing controls including cleaning, greasing the hinges, locking arrangement, checking the seviceability of individual items, identification of the defective parts replacing the wornout fastners, insulators, rubber door beadings, gakets etc all as directed Note:- (1) Unserviceable parts replaced if any shall be measured & paid seperately under respective items. |
| 76 | Removing the existing hinges by cutting and supply and fixing of new hinges all as per existing size |
| 77 | Painting of LT panel board/feeder pillar boxes with two coats of synthetic enamel spray paints over a coat of red oxide primer matching existing colour after scrapping the old paint by means of emery paper and cleaning with thinner including necessary markings/sign writing etc complete all as specified and directed. |
| 78 | Rewiring the LT cubical type panel by means of PVC insulated multi strandard copper wire of existing size including replacing unserviceable connectors, fastners etc,after taking out the old unserviceable wiring all as directed. |
| 79 | Material and labour for replacement of LED type indicator lamp (RYB) (Set of three) complete all as specified. |
| 80 | S&F in replacement of Digital Amp Meter 0-250 Amp with including making electric connection by suitable size of multistranded copper conductor with thimbles complete all as specified. |
| 81 | S&F in replacement of Digital Volt Meter 0-500 V including making electric connection by suitable size of multistranded copper conductor with thimbles complete all as specified. |
| 82 | S&F Indoor resin cast ring type low tension current transformer 50/5A to 75/5A 15VA burden accuracy class 1 confirming to IS 2705 /1992 |
| 83 | S&F Indoor resin cast ring type low tension current transformer 100/5A to 300/5A 15VA burden accuracy class 1 confirming to IS 2705 /1992 |
| 84 | S&F in replacement MCCB 4 Pole, 415 V, fixed type, 63 Amps with breaking capacity 16 KA. |
| 85 | Supply and Fixing in replacement MCCB 4 Pole, 415 V, fixed type, 100 Amps with breaking capacity 16 KA. |
| 86 | Supply and Fixing in replacement MCCB 4 Pole, 415 V, fixed type, 125 Amps with breaking capacity 25 KA. |
| 87 | Supply and Fixing in replacement MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 25 KA. |
| 88 | Supply and Fixing in replacement MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA. |
| 89 | Supply and Fixing in replacement MCCB 4 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA. |
| 90 | Supply and Fixing in replacement MCCB 4 Pole, 415 V, Adjustable type, 400 Amps with breaking capacity 36 KA. |
| 91 | Material and labour plain cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate for foundations / filling around the post, Poles etc complete all as specified and as directed. |
| 92 | Supply and installation, testing and commissioning in replacement of of Bus bar box out door type totally enclosed dust and vermin proof floor mounting with hinged doors and locking arrangement front and back fabricated out of 3.15 mm thick CRCA sheet CPRI approved test type make including powder coated paint finish including all accessories, provision independent removevable MS plates for fixing cable glands for all incomming and out going cables and complete control wiring with 2.5 sqmm copper conductor incuding necessary PCC foundation complete all specified. Note :- (1) Rates deemed to be included for suitable lugs and glands for incoming and out going of LT UG cable.(2) The Contractor Shall submit the drawing with sample of accessories for approval before executing the work. (a) Main incoming 125 Amps MCCB 04 pole, 25 KA - 01 nos (ICS=100%ICU) (b) Electrolytic grade aluminium bus bar 200A rating for 3 phase and neutral including PVC colour coded sleves. - 01 Set(c) LED lamps for R,Y,B Phase indication with control fuse/MCB - 01Set(c ) Volt meter digital type 96 sqmm with selector switch - 01 set(d) Amps meter digital type 96 sqmm with CT's 150/5 -03 Nos and selector switch - 01 Set (e) Insulators, wiring, bus bar sleeves, lugs, gland, sheet metal enclosure etc including complete wiring with suitable size of copper wire |
| 93 | Supply and installation, testing and commissioning in replacement of LT panel factory made suitable for 415 Volts ,3 Phase 4 Wire, 50 Hz AC supply system confirming to IS:8623/93, outdoor type, double door floor mounting weather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 3.15 mm thick having Aluminium bus bar of rating 400 Amp three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. sheet front and back door openable type and conforming to IP-54 and fixed on angle iron frame/channel of suitable size complete, aluminium bus bar chamber, cable alley, cable glands brass / chromium plated of diffrent sizes suitable for incoming and out going cables, panel painted with powder coated paint (LT panel shall be of CPRI approved manufacturer) incuding necessary PCC (1:3:6) foundation extending 600mm above GL and complete all specified and directed by Engineer-in-Charge with the following accessories:- Note : (i) Rates deemed to be included for suitable lugs and glands for incoming and out going of LT UG cable. (ii) The Contractor Shall submit the drawing with sample of accessories for approval before executing the work. (iii) The rates shall be deemed to includes the cost of keeping the surface clean and levelled all arround the Feeder piller box and provide INCOMING (a) Aluminium busbar of capacity 400 Amps with eppoxy insulated supports 3 phase and neutral -1 set (b) MCCB 200 Amps 4 pole 25 KA with adjustable type - 01 No (ICS=100%ICU) (c ) Volt meter digital type 96 sqmm with in built selector switch - 01 set (d) Amps meter digital type 96 sqmm with CT's 200/5 -03 Nos and in built selector switch - 01 Set (e) Indicating lamp set LED type - 01 set OUTGOING (b) MCCB 63 Amps, 4 Pole 16KA adjustable type - 3 Nos (ICS=100%ICU) |
| 94 | Supply and spreading stone aggregate of size not exceeding 40 mm spread and leveled in layers not exceeding 15 cm to a true surface of broken stones for LT panel and including cleaning away all grass, vegetation, saplings, shrubs, undergrowth, area complete all as specified and directed. Please Enable Macros to View BoQ information |