| 1 | Taking down carefully point wiring of any type & pattern (Light/Fan/Socket or power) including fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings of any type etc and making good disturbed surfaces of walls/ roof etc, complete all as specified and directed. |
| 2 | M & L for point wiring with PVC insulated FRLS unsheathed 1100 Volts grade single core multistranded copper conductor cable 1.5 Sqmm drawn in and including PVC casing-caping, fixed on wall / ceiling with all accessories, fittings, PVC junction boxes etc, with suitabe sunk pressed steel boxes for modular fittings not less than 1.6 mm thick, etc with necessary fixing accessories and earth continuity conductor cable of 1.5 Sqmm size connected to common earth and earth dolly including 1.6 mm thick pressed steel terminal boxes concealed in wall covered with laminated sheet top cover 3 mm thick for mounting switches / sockets / fan regulators fixed with Cadmium plated machine screws all as specified for one light / fan / bell point controlled by one switch. |
| 3 | -Ditto- all as per item No 02 here-in-before but for one 5A 2pin/3pin socket out let multipurpose on the same board with other switches. |
| 4 | -Ditto- all as per item No 02 here-in-before but for one 5A 2pin/3pin switch socket out let multipurpose on independent Board. |
| 5 | All as per item No. 02 above but wiring complete with 2.5 Sqmm for 3 pin 15A socket multipurpose on independent board |
| 6 | S&F piano type 5A one way SP switch 1 module confirming to IS: 3854-1997 with fingure proof terminal complete all as specified and directed. |
| 7 | S&F flush type 2/3 pin combined shuttered type 5 Amps socket 2 module conforming to IS: 1293-2005 complete all as specified and directed. |
| 8 | S&F flush type 2/3 pin combined flush type 5/15 Amps socket 2 module conforming to IS: 1293-2005 complete all as specified and directed. |
| 9 | S&F flush type 15 A one way SP switch 1 module confirming to IS: 3854-1997 with finguer proof terminal complete all as specified and directed. |
| 10 | S&F modular type 120W step fan regulator of 2 module size conformng to IS: 11037-1984 complete all as specified and directed. |
| 11 | Supply & Fix Modular Bell push flush type 6 Amp, 1 module, 230 Volts complete all as specified and directed. |
| 12 | Supply and fix bell ding dong AC 230 V single pole. complete all as specified and directed. |
| 13 | S & F Modular Blank plate 1 module suitable for Modular switch boards all as specified and as directed |
| 14 | S & F Modular cover plate 8 modules |
| 15 | S & F Modular cover plate 4 modules |
| 16 | S & F Modular cover plate 3 modules |
| 17 | S & F Modular cover plate 6 modules |
| 18 | S & F Modular cover plate 1 modules |
| 19 | S&F ceiling rose three terminal, 230 Volts PVC / Polycarbonate body, complete all as specified and directed. |
| 20 | Supply and fixing condenser 2.5 MFD with PVC clamp. |
| 21 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250m complete all as specified and directed. Make :- ALMONARD / ORIENT |
| 22 | Daily door to door repair/replacement of maintenance for Md Accn bldg covered under GE (NW) Mankhurd area (a) Thane by team of contractor's comprises of (a) One Electrician and 01 x Helper will be carried out daily under restective area :- Note 1 :-(a) Contractor will be assigned to visit one area daily alongwith man and material as per as per direction of Engineer-In-Charge and he will perform all petty repair work as demanded by user of bldg.(b) Contractor will make his own arrangement for to and fro of his team and his rates shall be inclusive of this aspect. (c) The material component require for above complaint will be measured and paid as “Supply only” under respective item of this schedule. Certain material may be issued from the department free of cost for fixing only as per direction of Engineer-in-Charge. (d) If contractor fails to attend the area, a sum of Rs 4000/- per days will be recovered on account of non attedance of petty repair work from any legitimate payment due to contractor. A sum of Rs 500 per false complaint/wrong signature will also be recovered from the contractor.(e) Contractor will also attend the petty repair work on all days of week i.e Working day as per direction of Engineer-in-Charge. Please Enable Macros to View BoQ information |
| 23 | Daily door to door repair/replacement of maintenance for Md Accn bldg covered under GE (NW) Mankhurd area (a) Thane by team of contractor's comprises of (a) One Electrician and 01 x Helper will be carried out daily under restective area :- Note 1 :-(a) Contractor will be assigned to visit one area daily alongwith man and material as per as per direction of Engineer-In-Charge and he will perform all petty repair work as demanded by user of bldg.(b) Contractor will make his own arrangement for to and fro of his team and his rates shall be inclusive of this aspect. (c) The material component require for above complaint will be measured and paid as “Supply only” under respective item of this schedule. Certain material may be issued from the department free of cost for fixing only as per direction of Engineer-in-Charge. (d) If contractor fails to attend the area, a sum of Rs 4000/- per days will be recovered on account of non attedance of petty repair work from any legitimate payment due to contractor. A sum of Rs 500 per false complaint/wrong signature will also be recovered from the contractor.(e) Contractor will also attend the petty repair work on all days of week i.e Working day as per direction of Engineer-in-Charge. Please Enable Macros to View BoQ information |