| 1 | Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed. |
| 2 | Demolition of brick work or stone/boulders masonary, built in cement mortor including all quoins, arches pillars, etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and directed. |
| 3 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc, laid, bedded, jointed and pointed in any mortar complete all as specified and directed by Engineer-in-charge. |
| 4 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing rubbish off premises complete all as specified and directed. |
| 5 | Dismantling posts or struts ( wood, steel or RCC) embedded in concrete, brick work etc, any section and any length including taking out embedded portion and making good disturbed ground complete all as specified and directed by Engineer-in-Charge. Note :- Dismantling of existing galvanised iron steel barbed wire/ chain link fencing shall be measured and paid for separately. |
| 6 | Dismantling chain link fencing of any guage & size not exc 4 Kg/Sqm complete all as specified and as directed. |
| 7 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thick above or below ground level complete all as specified and directed. |
| 8 | Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engineer-in-charge. |
| 9 | M&L for Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed by Engineer-in-Charge. |
| 10 | M&L for pre-polished chequered tiles (any colour) of size 30cm x 30cm x 25mm thick, with gray cement & pigment set, jointed and pointed in neat cement slurry in floors laid over and including 20mm screed bedding in cement mortar (1:4) complete all as specified and directed. |
| 11 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar (1:3) including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete all as specified and directed. |
| 12 | M&L for vitrified paving tiles (any colour) of size 30cm x 30cm x 10mm thick, with gray cement & pigment set, jointed and pointed in neat cement slurry in floors laid over and including 15mm screed bedding in cement mortar (1:4) complete all as specified and directed. |
| 13 | M&L for Coloured stone finish ceramic tiles in vertical surface 450x300x7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match incl 10mm thick plaster in cement mortar (1:3) complete all as specified and directed. |
| 14 | M&L for cement concrete (1:2:4) type B2 using 20mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railigs upto 60cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, sligtly rounded or chamfered angles and throating, as directed including necessary form work complete all as specified and directed. |
| 15 | M&L for Brick work with sub class ‘B’ old size burnt bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-charge. |
| 16 | M&L for Brick work with fly ash bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-charge. |
| 17 | M&L for PCC (1:4:8) type D-2, using 40mm graded stone aggregate in foundation , filing and mass concrete complete all as specified and directed. |
| 18 | M & L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation for post & struts & mass concrete including necessary form work and fair finishing complete all as specified and directed by Engineer-in-charge. |
| 19 | M&L for 75 mm thick PCC (1:3:6) type C-2 using 40 mm graded crushed stone aggregate as in plinth protection, finished fair and even complete all as specified and directed by Engineer-in-charge.Note :- Plinth protection shall be laid to slope (1 in 30) in bays not exceeding 3 metre in length and joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with sealing compound grade B. Cost of ceiling compund is included in the unit rate of this item complete all as spcified and directed. |
| 20 | M&L for 18-20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like including 20mm screed bedding in cement mortar (1:4) and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed. |
| 21 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations etc complete all as specified and directed. |
| 22 | M&L rendering 15 mm thick in CM 1:6 on brick masonry surfaces or on other than fair faces of brick masonry finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. |
| 23 | M&L for cement concrete (1:3:6) type C-1, using 20 mm graded stone aggregate as in surface channels or drain complete all as specified and directed. |
| 24 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc. complete all as specified and directed by Engineer-in-charge. |
| 25 | M&L preparation new or previously untreated steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over and including one coat of red oxide zinc chrome primer complete all as specified and directed by Engineer-in-Charge. |
| 26 | M&L preparation new steel surfaces of any description not exc 10 cm width or girth and applying two coats of synthetic enamel paint over and including one coat of red oxide zinc chrome primer complete all as specified and directed by Engineer-in-Charge. |
| 27 | M&L for preparartion of new plastered surfaces of walls and applying two coats cement base paint on walls complete all as specified and directed. |
| 28 | M&L for preparation of old plaster surfaces of walls and applying one coat of cement based paint on walls complete all as specified and directed. |
| 29 | M&L for complete removal and preparation of old treated surfaces for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @1.43 litre/10 sqm over and including priming coat of exterior primer applied @0.90 litre/10 Sqm complete all as specified and directed. |
| 30 | S&F mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, cooler stand 12mm sq guard bar, framework of water tanks and similar works of quality Fe 290 (Gde E-165) etc complete all as specified and directed by Engineer-in-charge. |
| 31 | M&L for providing and fixing stainless steel (Grade 304) ladder/railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the ladder/railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement. |
| 32 | S&F MS screw bolt 05 to 10mm dia, length of bolt exceeding 5cm but not exceeding 10 cm long machine made with hexagonal or square head at one end and screwed the other or serewed both ends, each screwed end fitted with washer and one hexagonal or square nut complete all as specified and directed by Engineer-in-Charge. |
| 33 | Supply only mild steel galvanized chain link fencing of any mesh, size and type complete all as specified and directed by Engineer-in-charge.Note:- (i) Flat iron, round bars, nut bolts and washer shall be measured and paid for separately. (ii)The payment shall be made to the contractor for actual weight ascertain by the BOO as odered by GE. |
| 34 | Fixing only mild steel galvanized chain link fencing any mesh, size and type to any type of standards, rails, straining bolts etc. including provision of binding wire complete all as specified and directed by Engineer-in-charge.Note :- Supply only chain link fencing shall be measured and paid for separately under respective item of BOQ. |
| 35 | S&F in repair galvanized 2 strand, steel barbed wire 2.24mm dia, barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails, straining bolts, including securing or tying at crossing with and provision of galvanized mild steel wire, staples or steel pins etc complete all as specified and directed by Engineer-in-charge.Note :- Each line of horizontal / vertical / diagonal wire to be measured for the purpose of payment. |
| 36 | M&L for Mild steel work in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc., flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 37 | S&F mild steel round bars 10mm dia, cut to length, bent to shape as in tie bar fixed to chain link fencing including necessary welding where required as per site requirement & other similar works conforming to Fe-290 (Gde E-165) complete all as specified and directed by Engineer-in-charge. |
| 38 | S&F mild steel framed work as in doors / gates / steel frames etc. of angle or other section with gusset plates, rails, braces, etc, complete, drilled for fixing of steel sheeting or other covering including necessary welding etc and fixing in position of quality Fe 290 (Gde E-165) complete all as specified and directed by Engineer-in-charge. Please Enable Macros to View BoQ information |