Tender For Removal Of Blockage Of Sewage Lines Including Necessary Repair Of Jcos & Ors Md Accn Under Age B/R - I Of Ge (West) Mathura

Issued by Statutory Bodies & Commissions/Committees · GE (WEST) MATHURA, Uttar Pradesh
Tender Value
40 Lakhs
Estimated cost
Bid Submission
08 Jul 2026
3 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
GE (WEST) MATHURA → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Removal Of Blockage Of Sewage Lines Including Necessary Repair Of Jcos & Ors Md Accn Under Age B/R - I Of Ge (West) Mathura

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 01-Jul-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 08-Jul-2026

BOQ

Name of Work:- REMOVAL OF BLOCKAGE OF SEWAGE LINES INCLUDING NECESSARY REPAIR OF JCOs & ORs MD ACCN UNDER AGE B/R - I OF GE (WEST) MATHURA
Sl. No. Item Description
1Cleaning of sewage lines blocked/filled with sludge, semi solid/solid material etc man holes to manholes by rodding/mechanical means without causing any damage to sewage lines/manholes. Manholes covers and taking out the same and removing to a non inhabitant area or buried into ground all as specified for the internal dia of pipes 150mm dia.Note : No sewage allowed to dump/drain in near by low lying area/drains due to hygenic issue.
2All as per Item No 1.00 above but for 200 mm dia.
3Cleaning of septic tanks by getting out sludge, semi solid/solid material etc by pumping/manual means including removal in covered veh to a non habitant area out side the MOD land or buried into ground septic tank not exc 50 users complete all as specified.Note :- The contractor shall remove the sewage / sludge and other foreign material from the site by mechanical equipment etc or other any mean to outside MOD land in covered Vehicles ie Veh required for transport of foul matters/gas etc and shall be disposed off as directed by Engineer-in-Charge. The site shall be left by the contractor in neat and tidy condition before claiming his payment.
4All as per Item No 3.00 above but septic tank exc 50 users and not exc 100 users complete all as specified and directed. Note :- The contractor shall remove the sewage / sludge and other foreign material from the site by mechanical equipment etc or by way or other any mean to outside MOD land in covered Vehicles ie Veh required for transport of foul matters/gas etc and shall be disposed off as directed by Engineer-in-Charge. The site shall be left by the contractor in neat and tidy condition before claiming his payment.
5Cleaning of blockage of any type in WC (Indian/Pedestal) from WC pan to 1st manhole in single/double/triple storied bldg (distance of 1st manhole from outer wall exc. 2 Mtr but n.exc. 5 Mtr including resetting/refitting of access door in soil pipe wherever open without causing any damage to the WC pan 'P' or 'S' trap and pipe including fitting complete all as specified.
6Cleaning of blockage of any type in Nahani trap /floor trap provided in bath room, kitchen and indoor water pipe of kitchen sinks and WHB and removing all the sludge and foreign material from the trap and the waste pipe from trap to gully trap surface drain wherever opened or without causing any damage to the trap and pipe including fitting, distance of gully trap from outer wall of bldg up to 2 Mtr complete all as specified.
7Excavation in trenches in soft/loose soil not exc. 1.5 M wide and not exc. 1.5 M deep and getting out including forming bottom to required level or slope for laying pipe and concrete bed or for manhole etc not exc. 10 Sqm on plan all as specified and directed by Engineer-in-Charge. (Pipe and concrete bed shall be measured and paid separately).
8All as in item No 7.00 above but exc. 1.5m deep and n.exc. 3.00m deep.
9Returning, filling in soft/loose soil including spreading, leveling and watering well ramming in layers n.exc. 25cm all specified and directed.
10Removing surplus soil to a distance exc 250m but n.exc. 500m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed.
11Demolition and breaking up drain pipes, set in cement mortar 150mm internal dia (SGSW, AC or reinforced concrete) complete all as specified and directed.
12All as per Item No 11.00 above but 200 mm dia.
13M&L 150mm bore reinforced concrete pipes, class NP2, laid and jointed complete with collars all as specified and directed.
14M&L 200mm bore reinforced concrete pipes, class NP2, laid and jointed complete with collars all as specified and directed.
15M&L cement concrete 1:3:6 mix type C2 (using 40mm graded stone aggregate) as in bed to drain pipe including packing under and hunching against the sides of pipes after laying in trenches to required slope and tested complete all as specified for 150 mm bore pipe complete all as specified and directed by Engineer-in-Charge. Note :- Thickness of concrete bed below the barrel of pipe shall be 10 cm and width of bed shall be outer dia of pipe plus 30 cm.
16All as per Item No 15.00 above but for 200 mm bore pipe. Note :- Thickness of concrete bed below the barrel of pipe shall be 15 cm and width of bed shall be outer dia of pipe plus 30 cm.
17M&L for PCC (1:4:8) type D-2, using 40mm graded stone aggregate in foundation, filing and mass concrete complete all as specified and directed.
18Demolition of brick work of any description and in any position built in cement Mortar and removing rubbish n.exc. 50m complete all as specified and directed.
19M&L for brick work built in cement mortar 1:4 with sub class 'B' bricks old size straight or curved on plan exc. 6m mean radius complete all as specified.
20All as per Srl item No 19.00 here-in-before but except brick.Note : Old serviceable brick retrieved from serial item No 18.00 of BOQ here-in-before shall be used under this item.
21M&L for brick work with sub class ‘B’ old size burnt bricks in one brick thick honey comb walling built in cement mortar (1:4) complete all as specified.
22M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
23M&L for TMT bars 6mm to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
24M&L for reinforced cement concrete (nominal mix) (1:2:4) type B1, using 20mm graded stone aggregate for slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and other similar works complete all as specified and directed and directed.
25Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for rough finished of flat surface complete all as specified and directed.
26M&L for cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) as in lintels upto 1.5 metre clear span, cills, steps, siesmic and other similar bands, plinth courses, string courses, lacing courses, coping, parapets and railing upto 60cm height, copings bed block,roof kerbs or mud stops, kerb stone, kneelers, apex stones, bed plates, surface channels and drains, benching, haunching water troughs and the like including weathering, slightly rounded or chamfered angles and throatings etc.including necessary form work complete all as specified and directed.
27Taking down cement plaster on brick or stone walls etc. including racking out joints, hacking for key, scrubbing down with water, any description etc. complete all as specified and as directed.
28M&L for rendering 15mm thick on fair faces of brick work/internal faces in man holes in CM 1:4 mixed with water proofing compound @ 200ml by weight of cement per 50 kg including finishing the surface even and smooth without using extra cement all as specified.Note : Supply of WPC shall be measured and paid separately.
29Supply only liquid water proofing compound ISI marked complete all as specified and directed by Engineer-in-charge
30M&L rendering 15mm thick in CM 1:4 on external surface of manholes surfaces finished fair and even without using extra cement complete all as specified and directed.
31Dismantiling floor, hearth or wall tiling including cement motar bedding ( but not backing ) removing serviceable tiles to store and rubbish off the premishes complete all as specified and directed.
32M&L Non skid coloured ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but n.exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match with and including 15mm thick screed bed in cement mortar (1:6) for laying floor finishes complete all as specified and as directed.
33M&L for glazed ceramic tiles 450x300x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to the match tiles on vertical surface over and including 10mm thick plaster in CM (1:4) complete all as specified and as directed.
34S&F in repairs vitreous china wash down water closet pan (Pedestal pattern), white including connection to drain (or outgoing pipe) and to flushing pipe, anti-sypohonage pipe etc. & with plastic WC seat cover white closed pattern with flat bottom and cover and mild steel chromium plated or aluminized hinging device and jet spray complete all as specified & as directed.
35S&F in repair vitreous china squatting pan Orissa pattern, white of size 580x440mm with integral foot rests (excluding flushing cistern and flush pipe) including cast iron 'P' or 'S' trap, PCC filling and connection to trap and flushing pipe, antisyphonage pipe etc complete all as specified and directed.
36S&F 110mm bore PVC (SWR) pipes single socketed in any length with solvent joints laid In trenches or fixed in wall including taking down old unserviceable PVC pipe and fittings complete all as specified and directed.
37S&F 75mm bore PVC (SWR) pipes single socketed in any length with solvent joints laid In trenches or fixed in wall including taking down old unserviceable PVC pipe and fittings complete all as specified and directed.
38S&F 110 mm bore PVC (SWR) bends any radius jointed with adhesive complete all as specified and as directed.
39S&F 75 mm bore PVC (SWR) bends any radius jointed with adhesive complete all as specified and as directed.
40S&F 100mm CI pipes soil, waste and vent pipe in any length with or without ears, with cement joints fixed to wall including taking down old unserviceable CI pipe and fittings complete all as specified and directed.
41S&F 100mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) with oval access door complete all as specified and as directed.
42S&F 75mm CI pipes soil, waste and vent pipe in any length with or without ears, with cement joints fixed to wall including taking down old unserviceable CI pipe and fittings complete all as specified and directed.
43S&F 75mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) with oval access door complete all as specified and as directed.
44S&F in repair stack clamps mode out of 50x5mm flat iron including bolts and nuts and securing ends of stays to wall or roof, for 100mm bore pipes, complete all as specified and directed.
45S&F in repair stack clamps mode out of 50x5mm flat iron including bolts and nuts and securing ends of stays to wall or roof, for 75mm bore pipes, complete all as specified and directed.
46Cutting into existing manholes for connecting new drains, making good for pipes and cutting out existing benching for and forming branch channels(1/2 round or ¾ section) in cement concrete 1:2:4, type B-1 smooth finished and forming benching as required for 150mm & 200mm dia SGSW pipe complete all as directed
47Demolition of cement concrete (reinforced) in ground floor/road (below or above ground level) all as specified.
48M&L Precast Cement Conctete 1:2:4 type B1, using 20mm graded stone aggregate as in cover slabs for man holes etc set in cement morter 1:6 including necessary form work complete all as specified and directed.
49M&L for preparartion of new plastered surfaces of walls and applying two coats cement base paint on walls complete all as specified and as directed.
50M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
51S&F 75-80mm thick factory made precast RCC manhole covers including precast frame of any size & shape (Squre / rectangular / circuler), light duty, out side, fixed at site etc complete all as specified and directed.Note : Reinforcment required shall be included in quoted item rate.
52Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thick above or below ground level complete all as specified and directed.
53M&L Plain cement concrete type B1 (1:2:4), using 20 mm graded crushed stone aggregate, 40 mm thick, as as in floor and finished even and smooth using extra cement laid in alternate bay and joints filled with bituminous compound grade 'A' complete all as specified and directed.
54S&F glass dividing strips of size 3mm thick and 38mm wide inserted in position complete all as specified and directed.
55Taking up or down 15mm dia, steel tubing & connections including cleaning for refixing or removal to store complete all as specified and directed.
56Taking up or down 20mm dia, steel tubing & connections including cleaning for refixing or removal to store complete all as specified and directed.
57S&F 15mm bore galvanized steel water tubing medium grade with & including all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
58S&F 20mm bore galvanized steel water tubing medium grade with & including all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
59S&F in repair 15 mm bore bib tap, cast copper alloy, chromium plated, long body, fancy type screwed down and screwed for iron pipe or for brass ferrule complete all as specified and directed.
60S&F in repair 15mm bore CP pillar taps Fancy type cast copper alloy (min weight 350 gm) along screwed down high pressure with lettered hot & cold with long screwed shanks and fly nuts screwed for GI pipe complete all as specified and directed.
61S&F 15mm bore CP pillar taps Fancy type cast copper alloy (min weight 350 gm) along screwed down high pressure with lettered hot & cold with long screwed shanks and fly nuts screwed for GI pipe complete all as specified and directed.
62S&F in repairs 15mm bore angle cock one way fancy type, chromium plated, high pressure, with crutch or butterfly handle, screwed both ends of iron pipe or for union and fixed complete all as specified and as directed.
63S&F in repairs 20 mm dia ball brass valve high pressure with polythene float and fly nuts complete screwed for iron pipes or brass ferrule and fixed complete all as specified and directed.
64S&F in repair 20mm dia PTMT ball valve high Pressure with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed (min wt 142 gms) complete all as specified and directed.
65S & F in repair for 15mm bib tap standard of PTMT any colour screwed for iron pipe and fixed complete all as specified and directed by Eng-in-charge.
66S & F in repair for 15mm angle cock standard of PTMT any colour screwed for iron pipe and fixed complete all as specified and directed by Eng-in-charge.
67S & F in repairs PVC 10 ltrs syphonic action type flushing cistern, low level with inlet, ball valve, float and handle including brackets, flush pipe of PVC 32mm bore and connection to WC pan complete all as specified and directed.
68S&F in repair chromium plated shower rose with or without swivel joints including fixing to steel pipe of 100 mm size complete all as specified and directed.
69S&F in repair CP Jet spary butter fly design fixed on EWC with stanless screw complete all as specified and directed.
70S&F in repair CP Health faucet with stand fixed on wall in CP hose pipe 1 mtr length and stainless steel screw complete all as specified and directed.
71S & F in repair of PVC connection pipe 15 mm size with nuts, washers of length 600 mm pipe complete all as specified and directed.
72S&F in repair 2 way 15mm CP angle fancy type 15 mm bore high pressure screwed for iron pipe complete all as specified and directed.
73S&F in repair 2 way 15mm CP bib tap fancy type 15 mm bore high pressure screwed for iron pipe complete all as specified and directed.
74S&F in repair PVC EWC seat cover of any type & make for pedestal pan complete all as specified and directed.
75S & F in repair vitreous china wash basin, white, flat back, size 550 X 400mm including waste pipe and brackets but excluding tapes, chain and plug etc complete all as specified and directed by Eng-in-charge.
76S&F in repairs towel rail chromium plated 20mm dia ‘D’ type, 600mm long complete all as specified and directed.
77S&F in repair stainless steel grating 100mm bore size fixed with white cement complete all as specified and directed.
78S&F in repair PVC waste pipe 32mm dia of length 0.8m to 0.9m fixed complete all as specified and directed.
79Hiring of honey sucker machine vehicle loaded 5-7 KL capacity for sunction of honey from all back location and thrown out away from MoD land complete all as specified and directed. Note : Rates of all labours, motors, pipes and other sunction accessories included in this item.
80M&L 75 mm thick Cement concrete type D-2, (1:4:8) using 40 mm graded stone aggregate as in sub base complete all as specified and directed.
81M&L for sand filling under floors or in foundation complete all as specified and directed.
82M&L for Machine pressed precast conctete interlocking paver block with grey cement & pigment any shape and size conforming to IS 15658-2006 of 60 mm thickness, M-35 Grade complete all as specified and directed.
83M&L for pre-polished chequered tiles (any colour) of size 30cm x 30cm x 25mm thick, with gray cement & pigment set, jointed and pointed in neat cement slurry in floors laid over and including 20mm screed bedding in cement mortar (1:4) complete all as specified and directed.
84M&L for vitrified paving tiles (any colour) of size 30cm x 30cm x 10mm thick, with gray cement & pigment set, jointed and pointed in neat cement slurry in floors laid over and including 15mm screed bedding in cement mortar (1:4) complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 55910351
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 40 Lakhs
LAST DATE 08-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Removal Of Blockage Of Sewage Lines Including Necessary Repair Of Jcos & Ors Md Accn Under Age B/R - I Of Ge (West) Mathura
Basic Detail
Tender No 8300/1406/E8
Bidding Type Tender
Location
City GE (WEST) MATHURA
State Uttar Pradesh
Key Dates
Publish Date 01 Jul 2026
Submission Date 08 Jul 2026
Open Date 15 Jul 2026
Finance
Tender Value 40 Lakhs
Tender Fee 500
EMD 80000
Exemption Available
Document List
Tender1406.pdf
Tendernotice_1.pdf
11ddbc1d-b86a-4020-bdad-a5dfca41db95.html
BOQ_863548.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 01, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 08, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 3 days
Jul 08, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Jul 15, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
pdf

Tender1406.pdf

pdf

Tendernotice_1.pdf

html

11ddbc1d-b86a-4020-bdad-a5dfca41db95.html

xls

BOQ_863548.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender