| 1 | Taking down carefully copper/aluminium point wiring of any type, batten or conduit, (Light, Fan, Socket or power) complete incl fittings and making good the disturbed surfaces of walls, ceiling etc in cm and applying two coats of white/colour washing/distempering etc to match the existing surface complete all as specified & directed. |
| 2 | Material & labour for point wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts grade, stranded, FRLSH PVC insulated, unsheathed copper conductor cable in and including PVC concealed conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories/ fittings, brass screws, washers etc, Sunk Zinc coated pressed steel terminal boxes including all cutting/ chases etc in walls, making good to walls, ceiling etc including two coats of white/colour washing/ distempering etc to the disturbed surfaces to match the existing with 3 mm thick plastic laminated sheet top cover concealed in wall with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, FRLSH PVC insulated copper stranded conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed for the followings. (Rate for cutting chasis of walls all are included in the quated rate) |
| 3 | One light point or one exhaust fan point controlled by one one , one way 05/06 Amp Switch |
| 4 | One fan point controlled by one one , one way 05/06 Amp Switch |
| 5 | One bell point controlled by one switch |
| 6 | One 3 pin, 05/06 Amps socket outlet point on independent board controlled by one, one way 05/06 Amps switch |
| 7 | One 3 Pin, 05 /06 Amps socket outlet point on same board controlled by one, one way 05/06 Amps switch |
| 8 | All as per serial item No 2 here in before but using 2.5 Sqmm nominal cross sectional area single core, FRLSH PVC insulated copper conductor cable, unsheathed for with 2.5 Sqmm earth wire for one 15 /16 Amps socket outlet point on independent board complete all as specified and directed |
| 9 | Material & labour for point wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts grade, stranded, FRLSH PVC insulated, unsheathed copper conductor cable in open conduit/casing caping of 25 mm dia or higher, medium grade complete with and including all PVC conduit accessories/fittings, brass screws, washers etc, Sunk Zinc coated pressed steel terminal boxes including all cutting/chases etc in walls, making good to walls, ceiling etc including two coats of white/colour washing/ distempering etc to the disturbed surfaces to match the existing with 3 mm thick plastic laminated sheet top cover concealed in wall with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, FRLSH PVC insulated copper stranded conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed for the followings. |
| 10 | One light point or one exhaust fan point controlled by one one , one way 05/06 Amp Switch |
| 11 | One fan point controlled by one one , one way 05/06 Amp Switch |
| 12 | One 3 pin, 05 /06 Amps socket outlet point on independent board controlled by one , one way 05/06 Amps switch |
| 13 | One 3 Pin, 05 /06 Amps socket outlet point on same board controlled by one, one way 5/06 Amps switch |
| 14 | All as per serial item No 4 here in before but using 2.5 Sqmm nominal cross sectional area single core, FRLSH PVC insulated copper conductor cable, unsheathed for with 2.5 Sqmm FRLSH earth wire for one 15 /16 Amps socket outlet point on independent board complete all as specified and directed. |
| 15 | Supply & fixing switch piano flush type, 05/06 Amps single pole , one way 240 volts complete all as specified & directed . |
| 16 | Supply & fixing of bell push, flush type 05/06 Amps, 240 volts complete all as specified & directed . |
| 17 | Supply & fixing bell, AC, 230 volts, single pole, ding dong type compete all as specified & directed. |
| 18 | Supply & fixing switch piano flush type, 15 /16 Amps single ploe, one way 240 volts complete all as specified & directed . |
| 19 | Supply & fixing socket outlet 3 pin, 05/06 Amps (2 -in-1 Multipurpose) flush type 240 volts complete all as specified & directed. |
| 20 | Supply & fixing of socket outlet 3 pin, 15/16 Amps (2 -in-1 Multipurpose) flush type 240 volts complete all as specified & directed. |
| 21 | Supply & fixing ceiling fan regulator, electronic, type, rotary 0 to 04 steps, hum free, AC, 230 volts, 100 watts duty ISI Marked with and including modular white surround complete all as specified & directed. |
| 22 | Supply & fixing lamp holder (Angular/Straight), insulated body, with back plate for batten fitting complete all as specified & directed |
| 23 | Supply & fixing of ceiling rose surface bakelite 65x 50mm three terminals complete all as specified & directed. |
| 24 | Material & labour point wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts grade, stranded, FRLSH PVC insulated, unsheathed copper conductor cable in existing conduit/casing caping of 20/25 mm dia or higher, medium grade complete with and including all PVC conduit accessories/fittings, brass screws, washers etc, Sunk Zinc coated pressed steel terminal boxes including all cutting/chases etc in walls, making good to walls, ceiling etc including two coats of white/colour washing/ distempering etc to the disturbed surfaces to match the existing with 3 mm thick plastic laminated sheet top cover concealed in wall with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, FRLSH PVC insulated copper stranded conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed for the followings. |
| 25 | One light point or one exhaust fan point controlled by one one , one way 05/06 Amp Switch |
| 26 | One fan point controlled by one one , one way 05/06 Amp Switch |
| 27 | One 3 pin, 05 /06 Amps socket outlet point on independent board controlled by one , one way 05/06 Amps switch |
| 28 | One 3 Pin, 05 /06 Amps socket outlet point on same board controlled by one, one way 5/06 Amps switch |
| 29 | All as per serial item No 15 here in before but using 2.5 Sqmm nominal cross sectional area single core, FRLSH PVC insulated copper conductor cable, unsheathed for with 2.5 Sqmm FRLSH earth wire for one 15 /16 Amps socket outlet point on independent board complete all as specified and directed. |
| 30 | S&F 20 watts Light emitting Diode (LED) tube light fitting warm/white surface mounting general purpose ultra slim ecomimical LED battens in extruded PC housing and round face diffuser wall mounting, indoor decorative LED battens, Integrated type, AC 230-240V, 50 hz, with PMMA/PC diffuser, 4' long, easy to install, Minimum 3.5 KV Voltage Surge Protection, Power factor > 0.9, with minimum effiacacy of 100 lm/watt making connections with and including 23/.0076 flexible cord of required length from ceiling rose to connector complete all as specified and directed. |
| 31 | S&F 10 watts Light emitting Diode (LED) tube light fitting warm/white surface mounting general purpose ultra slim ecomimical LED battens in extruded PC housing and round face diffuser wall mounting, indoor decorative LED battens, Integrated type, AC 230-240V, 50 hz, with PMMA/PC diffuser,Minimum 3.5 KV Voltage Serge Protection, Power factor > 0.9, ith minimum effiacacy of 100 lm/wattmaking connections with and including 23/.0076 flexible cord of required length from ceiling rose to connector complete all as specified and directed. |
| 32 | S & F Recess mounted economical LED panel light 2`X2` 36 watt white/warm with high quality diffuser for uniform light with minimum efficacy of 100lm/w housing of pressed aluminium sheeet with complete all as specified and directed. |
| 33 | S&F LED Bulk Head Fitting 10 Watt housing made up corrosion resistant unbreakable PC with high quality diffuser for glare free Aesthetically designed gaskit IP65 protection, with minimum efficacy of 100 Lumen /watt complete all as specified and directed. |
| 34 | Supply and fix in repair 09/10 Watt LED bollard light fiting for pathways and garden Cone/round, clear/ milky diffuser spun cover, die cast pole mounting, minimum efficacyof 95lm/watt, IP 65, module including fixing in concrete post suitable size GI pipe complete all as specified and directed. |
| 35 | Supplying, fixing in replacement LED Security light including connecting and testing of energy saving & environment friendly, made out of pressure die cast anodised aluminium with toughened glass cover housing, 45 watts LED to achieve electrical safety class 1, Pf >0.95, lumens >110 lm/W, Ingress protection not less than IP65, including 32mm nominal bore light grade GI pipe brackets made out of 1.50M long GI pipe ,bent to shape and fixed to poles/ walls with two Nos mild steel flat iron brackets of 40mmx6mm, comprisng 4 Nos mild steel hexogonal head bolts of 12 mm dia, 75 mm long with washers duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, and making connections with cable complete all as specified and directed. |
| 36 | Supplying, fixing in replacement LED Security light including connecting and testing of energy saving & environment friendly, made out of pressure die cast aluminium housing with toughened glass cover housing, 30 watts LED to achieve electrical safety class 1, Pf >0.95, lumens >110 lm/W, Ingress protection not less than IP65, including 32mm nominal bore light grade GI pipe brackets made out of 1.50M long GI pipe ,bent to shape and fixed to poles/ walls with two Nos mild steel flat iron brackets of 40mmx6mm, comprisng 4 Nos mild steel hexogonal head bolts of 12 mm dia, 75 mm long with washers duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, and making connections with cable complete all as specified and directed. |
| 37 | S&F PVC insulated & sheathed stranded copper cable 3 core of cross sectional area 1.5 Sqmm for providing necessary electrical connection from junction box to light fittings including with suitable size copper lugs as in repair Including taking down old U/S cable complete all as specified and directed. |
| 38 | M & L for sub main wiring with 4 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, stranded, FRLSH PVC insulated, unsheathed, copper conductor stranded cable with and including continuous earth wire of size 4 Sqmm nominal cross sectional area, single core ,FRLSH PVC insulated, copper conductor stranded cable drawing into and including rigid non metallic PVC conduit of 25 mm dia, medium grade with all conduit accessories/ fittings ,brass screws, washers etc and connected to common earth dolly including all cutting/ chases etc in wall, making good to walls etc including two coats of white/ colour washing/distempering etc to the disturbed surfaces to match the existing Including taking down old U/S sub main wiring any size complete all as specified & directed |
| 39 | M & L for sub main wiring with 6 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, stranded, FRLSH PVC insulated, unsheathed, copper conductor stranded cable with and including continuous earth wire of size 6.0 Sqmm nominal cross sectional area, single core , PVC insulated, copper conductor stranded cable drawing into and including rigid non metallic FRLSH PVC concealed conduit of 25 mm dia, medium grade with all conduit accessories/ fittings ,brass screws, washers etc and connected to common earth dolly including all cutting/ chases etc in wall, making good to walls etc including two coats of white/ colour washing/distempering etc to the disturbed surfaces to match the existing Including taking down old U/S sub main wiring any size complete all as specified & directed. |
| 40 | M & L for sub main wiring with 10 Sqmm nominal cross sectional area, 4 single core, 1100 Volts grade, stranded, FRLSH PVC insulated, unsheathed, copper conductor stranded cable with and including continuous earth wire of size 10.0 Sqmm nominal cross sectional area, single core ,FRLSH PVC insulated, copper conductor stranded cable drawing into and including rigid non metallic PVC conduit of 25 mm dia, medium grade with all conduit accessories/ fittings ,brass screws, washers etc and connected to common earth dolly including all cutting/ chases etc in wall, making good to walls etc including two coats of white/ colour washing/distempering etc to the disturbed surfaces to match the existing Including taking down old U/S sub main wiring any size complete all as specified & directed. |
| 41 | Supplying and fixing 10 Sqmm 1100 volts grade heavy duty cable FRLSH PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, twin core cable flat or circular Including taking down old U/S wiring any size complete all as specified and directed. |
| 42 | Supply & fixing MCB, SP, AC, 240 volts of 05 to 32 Amps capacity 10KA, 'C' series and making connections with suitable size of copper lugs Including taking down old U/S MCB any size complete all as specified & directed. |
| 43 | Supply & fixing MCB, SPN, AC, 240 volts of 40 to 63 Amps capacity 10KA, 'C' series and making connections with suitable size of copper lugs Including taking down old U/S MCB any size complete all as specified & directed. |
| 44 | Supply & fixing MCB, TPN, 415 volts of 63 to 100 Amps capacity 10KA, 'C' series and making connections with suitable size of copper lugs Including taking down old U/S MCB any size complete all as specified & directed. |
| 45 | Supply & fixing MCB DB Box 8 way 200 Amps capacity, 240 volts, Double door, SPN and flush to wall including all cutting etc on wall and making good the disturbed surfaces with painting the wall to match the existing all as specified & directed including taking out old u/s DBs any capacity. |
| 46 | Supply & fixing MCB DB Box 4 way 200 Amps capacity, 240 volts, Double door, SPN and flush to wall including all cutting etc on wall and making good the disturbed surfaces with painting the wall to match the existing all as specified & directed including taking out old u/s DBs any capacity. |
| 47 | Supply & fixing MCB DB Box 12 way 200 Amps capacity, 240 volts, Double door, SPN and flush to wall including all cutting etc on wall and making good the disturbed surfaces with painting the wall to match the existing all as specified & directed including taking out old u/s DBs any capacity. |
| 48 | Supply & fixing Sheet Metal Enclosures TPN, 4 way, 415 Volt, Double door for housing MCB's/Isolators and flush to wall including all cutting etc on wall and making good the disturbed surfaces with painting the wall to match the existing all as specified & directed including taking out old u/s TPN any capacity. |
| 49 | Supply & fixing Sheet Metal Enclosures vertical TPN distribution board with provision for & including 100 Amp MCCB TPN as incomer with necessary internal wiring, MCBs as outgoing , 4 way, 415 Volt, Double door for housing MCB's/Isolators and flush to wall including all cutting etc on wall and making good the disturbed surfaces with painting the wall to match the existing all as specified & directed including taking out old u/s DBs any capacity. |
| 50 | S&F in replacement MCCB 4Pole 415 V fixed type, 63/100 Amps with breaking capacity 16 KA Including taking down old U/S MCCB any size complete all as specified and directed. |
| 51 | Supply & fixing in repairing PVC casing caping / flexible conduit 25 mm complete all as specified |
| 52 | Supply & fixing in repairing PVC casing caping /flexible conduit 15 mm complete all as specified |
| 53 | Supply & fix in replacement of decorative new generation IP 65 LED post top lantern of 45 watts 230 volts, 50 HZ, mushroom or oval shaped in sothing opal/ prismatic finish made up of polycarbonate,energy saving, environmental frienldy long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source all as specifed and directed. |
| 54 | S&F in repair hylum sheet of size 5\\"x5\\" including cutting to required shape for fixing of existing switches and sockets complete all as specified and directed. |
| 55 | S&F in repair hylum sheet of size 8\\"x5\\" including cutting to required shape for fixing of existing switches and sockets complete all as specified and directed. |
| 56 | S&F in repair hylum sheet of size 10\\"x12\\" including cutting to required shape for fixing of existing switches and sockets complete all as specified and directed. |
| 57 | S&F in repair hylum sheet of size 8\\"x10\\" including cutting to required shape for fixing of existing switches and sockets complete all as specified and directed. |
| 58 | S&F in repairs\\" sunken steel boxes zinc oxide plated of size 4''x4'' including cutting the wall to required shape for fixing and making good the disturbed surfaces to match existing one complete all as specified and directed. |
| 59 | S&F in repairs\\" sunken steel boxes zinc oxide plated of size 7''x4'' including cutting the wall to required shape for fixing and making good the disturbed surfaces to match existing one complete all as specified and directed. |
| 60 | S&F in repairs\\" sunken steel boxes zinc oxide plated of size 9''x11'' including cutting the wall to required shape for fixing and making good the disturbed surfaces to match existing one complete all as specified and directed. |
| 61 | S&F in repairs\\" sunken steel boxes zinc oxide plated of size 7''x9'' including cutting the wall to required shape for fixing and making good the disturbed surfaces to match existing one complete all as specified and directed. |
| 62 | M & L for LED Bulb 12 watt 240 volt |
| 63 | M&L for earthing complete with galvanised MS earth plate of size 600 x 600 x 6mm thick burried directly in ground not less than 2.25 Mtr below ground level, earth plate paced on all side with charcoal mixed with salt to a thickness of 150 mm in layers, connected by GI earth wire of size 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion (GI earth strip will be protected by using 40mm bore GI pipe (light grade) from test point to main board. The earthing includes PCC pit chamber, RCC pit cover and frame, watering pipe 20mm bore, funnel with wire mess with necessary earth work including disposal of surplus soil to a distance not less than 50 Mtr etc complete all as specified and shown in electrical plate No 3 of SSR Part-I. including taking out old u/s earthing. |
| 64 | Taking down of existing unserviceable ceiling fan and Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complele all as specified and directed. |
| 65 | Taking down of existing U/s wall fans and S&F 400 mm sweep BLDC wall mounting fan 400 mm sweep BLDC in replacement including making connections with suitable size of copper wire and making good surfaces complele all as specified and directed. |
| 66 | Taking down existing U/S ceiling fan of 1200/1400 mm sweep from fan box/ hooks by disconnecting electrical connections from ceiling rose, de-assembling the fan, cutting the winding and removing the coils and rewinding the fan with suitable size of super enameled copper winding wire, insulation, varnishing, greasing and assemling the fan with 2.5MFD capcacitor including replacement of ball bearing and connection wire upto ceiling rose 1.5 metre, cleaning, painting and testing the fan for its rpm and others and refixing the fan in its position and making connections with existing wire with terminals of ceiling rose and replacement of mild steel clamps and S hook complete all as specified. |
| 67 | Taking down existing serviceable ceiling fan of any sweep from fan box/ hooks by disconnecting electrical connections from ceiling rose, de-assembling the fan, removing and cleaning of dust properly , oiling and greasing bearings/ bushes including renewal of washers, split pin, screws, checknuts, pin etc. and re-assembling and refixing in position , connecting and testing complete all as specified. |
| 68 | Taking down existing unserviceable exhaust fan of 450mm/380mm/300mm sweep from fan box/ hooks by disconnecting electrical connections from ceiling rose, de-assembling the fan , cutting the winding and removing the coils and rewinding the fan with suitable size of super enameled copper winding wire, insulation, varnishing, greasing and assemling the fan with 2.5/4MFD capcacitor including replacement of ball bearing gun metal bush and connection upto 1.5 metre , cleaning, painting and testing the fan for its rpm and others and refixing the fan in its position and making connections with existing wire with terminals of ceiling rose complete all as specified. |
| 69 | Taking down existing serviceable Exhaust fan of any sweep from fan box/ hooks by disconnecting electrical connections from ceiling rose, de-assembling the fan, removing and cleaning of dust properly , oiling and greasing bearings/ bushes including renewal of washers, split pin, screws, check nuts, pin etc. and re-assembling and refixing in position, connecting and testing complete all as specified. |
| 70 | Taking down of existing U/s exhaust fan plastic body 250mm and S&F exhaust fan plastic body 250mm sweep in replacement including making connections with suitable size of copper wire and making good surfaces complete all as specified. |
| 71 | Supply & fixing in repair switch piano flush type, 05/06 Amps single pole , one way 240 volts complete all as specified & directed . |
| 72 | Supply & fixing in repair of bell push, flush type 05/06 Amps, 240 volts complete all as specified & directed . |
| 73 | Supply & fixing in repair switch piano flush type, 15 /16 Amps single pole, one way 240 volts complete all as specified & directed. |
| 74 | Supply & fixing in repair socket outlet 3 pin, 05/06 Amps (2 -in-1 Multipurpose) flush type 240 volts complete all as specified & directed. |
| 75 | Supply & fixing in repair socket outlet 3 pin, 15/16 Amps (2 -in-1 Multipurpose) flush type 240 volts complete all as specified & directed. |
| 76 | Supply and fixing in replacement , bracket made out of 40 mm dia galvanized steel tubing medium grade 1.5 m long including bending if required as direct ,02 nos clamps made out of MS flat iron 40X6mm of suitable size fixed with bolts, nuts and washer including drilling holes and grouting with the same for fixing bolts complete.(Rates quoted by the contractor shall deemed to include for nut and bolts). |
| 77 | S & F in replacement of PVC desert cooler operating on single phase 230V, 50 Hz with a high-torque, 100% copper-wound high efficient motor featuring Thermal Overload Protection (TOP), driving an aerodynamically designed fan capable of delivering a minimum air displacement of 5500CUM per hour suitable for air through upto 650 SQft with 100 ltr tank capacity with High-Density Honeycomb Pads: Equipped with an wide ice chamber and high-density honeycomb pads, the cooler ensures to throw cool air with a boost of ice like cooling and superior comfort for a longer period with stand free on roller mounting with min dimensions of cooler: 47D x 70.5W x123.5H Centimeter setc all as specified and directed. Please Enable Macros to View BoQ information |