| 1 | Excavating in trenches not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide for laying of cables and getting out in soft/loose soil all as specified and as directed by Engr-In-Charge. |
| 2 | M&L for sand cushioning to under ground cable in trenches in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed by Engr in charge. Note:- Measurement shall be taken after gentling puning of sand. |
| 3 | Supply and Laying Unreinforced precast concrete cable cover class LV type 1, flat, size 250mmx150mmx40mm complete all as specified and as directed. |
| 4 | Returning, filling in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each , filling back in trenches after cables have been laid and tested complete all as specified. |
| 5 | Removal of excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified. |
| 6 | Supplying, laying or fixing or passing through pipe, testing and commissioning XLPE insulated, steel tape / wire armoured heavy duty electric underground cable, 1100 volts grade with stranded aluminium conductor of following nominal cross sectional area (from Item no 7 to 14) :- |
| 7 | 35 Sqmm 3.5 core. |
| 8 | 50 Sqmm 3.5 core. |
| 9 | 70 Sqmm 3.5 core. |
| 10 | 95 Sqmm 3.5 core. |
| 11 | 120 Sqmm 3.5 core. |
| 12 | 150 Sqmm 3.5 core. |
| 13 | 185 Sqmm 3.5 core. |
| 14 | 240 Sqmm 3.5 core. |
| 15 | Supply & fixing cable jointing kit for 1.1KV grade cable for straight through joint complete with jointing material (Epoxy based) and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 10 Sqmm to 35 Sqmm complete all as specified and directed. |
| 16 | Supply & fixing cable jointing kit for 1.1KV grade cable for straight through joint complete with jointing material (Epoxy based) and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm complete all as directed. |
| 17 | Supply & fixing cable jointing kit for 1.1KV grade cable for straight through joint complete with jointing material (Epoxy based) and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm complete all as specified and directed. |
| 18 | Dismantling of PCC pole/cracked pole from site complete all as specified and directed. |
| 19 | Supply and erecting steel tubular swaged pole with cast iron base plate, finial taper plug, bolts, nuts & washers made out of mild steel tubing, type 410 SP -31 (9 Mtr long) including marking pole No on pole including painting of poles with one coat of red oxide primer and two coat of aluminum paint (one coat before fixing and one coat of aluminum paint after fixing) over exposed surface and two coats of bituminous paint over embedded portion & the portion above coping shall be painted in alternative bands of black and yellow colour starting with white colour (each band of 30cm wide) by two coats of super enameled paint upto 1.5m height complete all as specified and directed by Engr in Charge. Note : Earth work and PCC in foundation shall be measured separately. |
| 20 | Excavating in trenches, n exc 1.5 m wide and more than 1.5 m n exc 3.0 m in depth; for foundation poles, etc. Or for shafts, wells, cesspits, manholes, pier holes, etc. N exc 10 sq m on plan and n exc 3.0 m in depth and getting out complete all as specified and directed |
| 21 | M&L for cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and as directed. |
| 22 | M&L for cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed. |
| 23 | M&L for cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in coping complete all as specified and as directed. |
| 24 | Dismantling old unserviceable cross arms and anti climbing devices of any size from pole/structures complete all as specified and as directed. |
| 25 | M&L for mild steel cross arms, bracings, support, clamps and back plates fabricated from structural steel section confirming to Fe-410-O or Fe-310-O including nuts, bolts and washers welding, bending cold or hot drilling holes for bolts in any shape or size all as directed including applying two coats of aluminium paint over a coating of red oxide primer complete all as specified and as directed. |
| 26 | Cutting wild grass, bushes, creaper, unwanted vegetation from inside / surrounding of E/M installations, near transformers, pole structures etc including cutting creapers from barbed / cattle fencing of the installations as when directed and removing of unwanted material from installation compound and depositing complete all as specified and as directed.Note : The item shall be operated maximum three times in entire period of contract in the same installations. (Area shall measured separately each time). |
| 27 | Supply, installing, testing and commission outdoor double door LT feeder pillar box, cubical type suitable for 3 phase 4 wirem, 50Hz and CPRI approved factory fabricated, powder coated (thickness not less than 100 micron) outer shall be made out of 3.15 mm thick CRCA sheet and MS angle section 50x50x6mm and inner sheet shall be made out of 2.00mm thick CRCA sheet duly compartmentalized having thimble and cable entry boxes with suitable size of aluminium bus bar 04 Nos (three phase and one neutral) mounted/fixed on suitable size angle iron frame/stand embedded in cement concrete type B-1 1:2:4 (using 20mm graded stone aggrigates) including painting steel surface with two coats of synthetic enameled paint over a coat of red oxide primer and general construction confirming to IS/IEC-61439-1:2011, 61439-2:2011 consisting of the following :-(a) MCCB 160 Amp,4P, 25KA adjustable thermal and adjustable magnetic (I/C) - 01 Nos(b) MCCB, 100 A, 25KA, 3 Pole fixed thermal and fixed magnetic (O/G)- 01 Nos(c) MCCB, 63 A, 25KA, 3 Pole fixed thermal and fixed magnetic (O/G)- 02 Nos(c.) Aluminium Bus bar (RYB & N) 250 Amps Rating with 2 Nos outgoing arrangement - 01 Set (d) Three Phase LED Indicator switch RY & B |
| 28 | Supply, installing, commissioning and testing of LT panel board outdoor type, cubical type made out CRCA sheet 3.15 mm thick, inner sheet 2.0 mm thick, dust and vermin proof as per IS/IEC-:61439-1:2011, 61439-2:2011 having thimble and cable entry boxes with cable glands. Panel should covered from all sides with front and back lockable door and hinges complete with aluminum bus bar 300Amp - 03 Nos for Phase and 01 No for neutral, (in separate chamber) mounted/fixed on suitable size angle iron frame/stand embedded in cement concrete type B-1 1:2:4 (using 20mm graded stone aggrigates) including painting steel surface with two coats of synthetic enameled paint over a coat of red oxide primer and consisting of the following:- (a) MCCB 200 Amp, 4 Pole, 36KA adjustable thermal and adjustable magnetic (I/C) -01 No(b) MCCB 63A, 16 KA, 3 Pole fixed thermal and fixed magnetic (O/G)- 06 Nos(c) Digital meter with Voltmeter (0-500V) - 01 No(d) Rating of CT & Ammeter as per Bus bar capacity as mentioned in BOQ(e) Selector Switch for Ammeter (R,Y & B) - 01 Set(f) Selector Switch for Voltmeter (RY,YB & BR) - 01 Set(g) Indicationg Lamps (R,Y,B) - 01 SetNote : Drawing of LT panel shall be got approved from GE before placing the order for procurement. |
| 29 | Supply, installing, commissioning and testing of LT panel board outdoor type, cubical type made out CRCA sheet 3.15 mm thick, inner sheet 2.0 mm thick, dust and vermin proof as per IS/IEC-:61439-1:2011, 61439-2:2011 having thimble and cable entry boxes with cable glands. Panel should covered from all sides with front and back lockable door and hinges complete complete with aluminum bus bar 800 Amp - 03 Nos for Phase and 01 No for neutral, (in separate chamber) mounted/fixed on suitable size angle iron frame/stand embedded in cement concrete type B-1 1:2:4 (using 20mm graded stone aggrigates) including painting steel surface with two coats of synthetic enameled paint over a coat of red oxide primer and consisting of the following:- (a) MCCB 630 Amp,4P, 36KA adjustable thermal and adjustable magnetic (I/C) - 01 Nos( b) MCCB, 200A, 25KA, 3 Pole fixed thermal and fixed magnetic (O/G)- 02 Nos(c) MCCB 125A, 25 KA, 3 Pole fixed thermal and fixed magnetic (O/G)- 01 Nos(d) MCCB 100A, 16 KA, 3 Pole fixed thermal and fixed magnetic (O/G)- 01 Nos(e) Digital meter with voltmeter, ammeter, slector switch, CTs, Control Fuse and Indicating Lights,- 01 Set |
| 30 | S&F of Bus Bar Chamber outdoor type made out of 1.6 mm thick CRCA sheet 8 way TPN 250 Amps Bus Bar rating including fixing on Wall / Pole with suitable size of clamp, Nut & Bolt or as per site requirement for fixing of outdoor site with provision of angle iron legs 45 x 45 x 3 mm, 750mm long for grouted with PCC and incommer and outgoing cable connections with suitable size of lugs complete all as specified and directed. |
| 31 | M&L for Earthing complete with galvanised steel earth plate electrode 60cmX60cmX6.0mm thick, buried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of the plate not than 1.5mtr below normal ground level connected to GI strip of size 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron complete earth pit of PCC M-10(Nominal mix) using 20mm graded stone aggregate, 50mm thick earth pit cover of RCC M-15 (Nominal mix) using 20mm graded stone aggregate with MS TMT reinforcement bar of 8mm dia @ 150mm centre to centre both ways, MS handle 10mm dia made to shape, PGI funnel, wire mesh and 15 mm bore GI water pipe medium grade and 40mm bore medium grade GI pipe for protection of earth strip from plate to main switch board, common salt, charcoal dust including testing on completion complete all as specified and as directed all as shown in electrical plate No. 3 including testing on completion and making good the disturbed surfaces of wall floors etc without claiming extra cost complete. Note : GI strip beyond 7.5Mtr length from earth electrode shall be measured and paid separately. |
| 32 | M&L for GI strip of size 32x6mm as earth continuity conductor burried in ground or drawn in pipe or fixed to wall on saddle. Note:- Cost of insulating saddle for fixing of GI strip on wall/roof/floor etc is included in quotated rates. |
| 33 | M&L for Copper strip of size 32x6 mm as earth continuity conductor burried in ground or drawn in pipe or fixed to wall on saddle. Note:- Cost of insulating saddle for fixing of copper strip on wall/roof/floor etc is included in quotated rates. |
| 34 | M&L for copper earthing in replacement with copper earth plate electrode 90 cm X 60 cm X 5 mm buried directly in ground (earth pit not less than 3.0 mtr deep beliow ground level) with top edge of the plate not less than 2.25 mtrs below normal ground level,connecting to copper strip 32 X6 mm as earthing strip by means of bolts,nut check nut and washers protected with and including 40 mm dia medium grade GI pipe,necessary excavation and earth work,magnesium sulphate (80 Kg) ),charcoal (2 Qtl) and common salt (2 Qtl) filling,watering arrangement with 20 mm GI pipe medium grade including PCC pit with pre cast RCC (1:2:4) cover ,GI funnel with test point,testing (all as shown in electrical plate No 5 and commissioning all as specified and directed. |
| 35 | Supply and laying GI Pipe light grade with all fitting and fixed complete to walls/poles/underpass and ceilings or laid in floors complete all as specified and directed of following sizes (for item no 36 to 37) |
| 36 | 80 mm bore |
| 37 | 100 mm bore |
| 38 | Supply and fixing in replacement of MCCB 630Amp rating, 4-pole 415V, Electronic release with overload and short circuit adjustable type breaking capacity 50 KA. |
| 39 | Supply and fixing in replacement of MCCB 400Amp rating, 4-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 36 KA. |
| 40 | Supply and fixing in replacement of MCCB 350 Amp rating, 4-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 36 KA. |
| 41 | Supply and fixing in replacement of MCCB 250 Amp rating, 4-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 36KA. |
| 42 | Supply and fixing in replacement of MCCB 200 Amp rating, 4-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 36KA. |
| 43 | Supply and fixing in replacement of MCCB 160 Amp rating, 4-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 16KA. |
| 44 | Supply and fixing in replacement of MCCB 100 Amp rating, 4-pole 415V, adjustable thermal adjustable megnetic type adjustable thermal adjustable megnetic type breaking capacity 16KA. |
| 45 | Supply and fixing in replacement of MCCB 63 Amp rating, 4-pole 415V, adjustable thermal adjustable megnetic type adjustable thermal adjustable megnetic type breaking capacity 16KA. |
| 46 | Supply and fixing in replacement of MCCB 250Amp rating, 3-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 35KA. |
| 47 | Supply and fixing in replacement of MCCB 200Amp rating, 3-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 35KA. |
| 48 | Supply and fixing in replacement of MCCB 160Amp rating, 3-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 16KA. |
| 49 | Supply and fixing in replacement of MCCB 125Amp rating, 3-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 16KA. |
| 50 | Supply and fixing in replacement of MCCB 100Amp rating, 3-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 16KA. |
| 51 | S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as per IS 15965: 2012 in roof covering /cladding to wall with self tapping screws complete. |
| 52 | S&F PVC sheet 0.50mm to 1 mm thick of any colour having water proof in roof covering /cladding to wall with self tapping screws complete all as specified and as directed by Engr-in-cgarge. |
| 53 | M&L for mild steel framed work angle iron flat, channels, etc including nut, bolts, welding drilling holes etc confirming to Fe-410-O or Fe 310-0 complete all as specified and as directed. |
| 54 | M&L for carrying out calibration of Air Circuit Breaker 630 Amp to 1000 Amps,over fault relay,earth fault relay,checking of alignment of ACB isolating contacts,servicing of electronic operating mechanism including tripping and closing system of the breakers,dehydrating,decorbonising of panel,bus section & circuit section. Removing perished monoplus compound cleaning and re-insulating with LT taps wherever necessary by authorised dealer/representative and refixing the ACB breaker in its original position and testing entire satisfaction of Engineer-in-charge. Note : (i) The major spare parts measeured and paid separetely against items at BOQ.(ii) Calibration of ACB shall be got carried out from autorised representative of OEM |
| 55 | Supply and Fixing in replacement of spring charging motor capacity 110/230 Volt suitable for ACB capacity upto 800 Amp, 4 pole,50 HZ,AC complete all as specified and as directed. |
| 56 | Supply only shunt trip coil suitable for ACB capacity upto 800 Amp ,4 pole,50 HZ, AC complete all as specified and as directed. |
| 57 | Supply only under voltage trip device suitable for ACB capacity upto 800 Amp, 4 pole,50 HZ,AC complete all as specified and as directed. |
| 58 | Supply only Adapter type terminal suitable for ACB capacity upto 800 Amp, 4 pole,50 HZ,AC complete all as specified and as directed. |
| 59 | Supply only in replacement of Spring charge indication switch suitable for ACB capacity upto 800 Amp, 4 pole,50 HZ,AC complete all as specified and as directed. |
| 60 | Supply only trip indication switch suitable for ACB capacity upto 800 Amp, 4 pole,50 HZ,AC complete all as specified and as directed. |
| 61 | Supply only position indication switch suitable for ACB capacity upto 800 Amp, 4 pole,50 HZ,AC complete all as specified and as directed. |
| 62 | Supply only on/off push button suitable for ACB capacity upto 800 Amp, 4 pole,50 HZ,AC complete all as specified and as directed. |
| 63 | Supply only on/off neutral CT suitable for ACB capacity upto 800 Amp, 4 pole,50 HZ,AC complete all as specified and as directed. Please Enable Macros to View BoQ information |