| 1 | Rewinding of VT Motor & Booster Motor (Centrifugal Motor) Kirloskaer make / Equivalent make as per original winding 415 volt with super enamelled copper wire as required gauge complete all respect as per direction of Engineer incharge. It is also include the dismentling / Refixing / Catage from site to workshop / factory and vice versa. The old material will the property of contractor (Old material rate already deducted in AOR) |
| 2 | 65 HP, 1440 RPM |
| 3 | 40 HP, 1440 RPM |
| 4 | Reapair /Rewinding of 75 HP NON Clog Submersible Motor pump (a) Motor Rewinding with \\"P\\" Calss insulation |
| 5 | winding thermostate 140+5 on/off auto cut |
| 6 | S/F Upper mechanical seal |
| 7 | S/F Lower mechanical seal |
| 8 | S/F cable protector |
| 9 | S/F O Ring |
| 10 | S/F Nilos ring |
| 11 | S/F DI Impeller |
| 12 | Spring washer |
| 13 | Plan head Screw |
| 14 | S/F Fasteners Set |
| 15 | Profile gasket |
| 16 | Motor pump dismantling,assembling i/c labour charge |
| 17 | S/F Submersible Motor Pump.(Make-Kirloskar, Ksb & CRI) ( 60 HP) |
| 18 | Supply, Erection, Testing and commissioning of Non clog submersible pump set complete in all respect as per direcction of engineer in charge. Technical specification of pump set shall be as given below. (1) Motor type:- SQ. Cage induction motor 960 RPM suitable for operation on 400/440 volts 3 phase, 50 HZ AC supply with F class insulation & IP-68 protection.(2) Pump:- (A) Body:- cast iron with 2% nickel. (B) IMPLELLER:- CF8M(SS3160) (C) SHAFT:- Stainless steel (SS304) (D) AUTO COUPLING STAND:- CF8M (SS316) (E) GUIDE PIPE:- Stainless Steel (SS316) (F) LIFTING CHAIN:- Alloy Steel @ 16 mtr (G) MECHANICAL SEAL:- Upper seal ( Carbon Chrome steel ) Lower seal ( Silicon carbide) (3) FIELD REQUIREMENT:- (A) TYPE:- Non Clog Sewage Submersible Pump (C) RPM:- 960 (D) HEAD:- 28mtr (E) COPPER CABLE FOR SEWAGE SUBMERSIBLE PUMP SUITABLE SIZE @ 25 MTR (F) SPECIFIC GRAVITY OF SEWAGE:-1.07 (G) SOLID HANDLING CAPACITY (DIA):- Not less than 100 mm Note:- Contractor shall be submitted G.T.P. & all company test certificate of the material used in pump set. (make- pullen pump industries pve ltd/ M/S Aqua Machineries Pvt. Ltd./ M/s Kishor Pumps Pvt. Ltd) NON CLOG SUBMERSIBLE PUMP SET Discharge 612 m3/hr. Head:- 28 mtr, Rating 90/120, Outlet size of pipe 200 mm dia cable- 2X50 sqmm x 3.50 core + 1.50 sqmm x 4.0 core |
| 19 | S/F 630 Amp 3 Pole MCCB uP Type, 50 KA (MAKE- L&T. C-POWER / D-SINE) / SIEMENS (3WL / VL) / SCHNIEDER (MASTERPACT / NSX) |
| 20 | S/F 400 Amp 3 Pole MCCB uP Type, 50 KA (MAKE- L&T. C-POWER / D-SINE) / SIEMENS (3WL / VL) / SCHNIEDER (MASTERPACT / NSX) |
| 21 | S/F 250 Amp 3 Pole MCCB uP Type, 50 KA (MAKE- L&T. C-POWER / D-SINE) / SIEMENS (3WL / VL) / SCHNIEDER (MASTERPACT / NSX) |
| 22 | S/F 100 Amp 3 Pole MCCB uP Type, 50 KA (MAKE- L&T. C-POWER / D-SINE) / SIEMENS (3WL / VL) / SCHNIEDER (MASTERPACT / NSX) |
| 23 | S/F of 3 Pole Power Contactor AC3 225 Amp. (MAKE- L&T / SIEMENS / SCHNIEDER) |
| 24 | S/F of 3 Pole Power Contactor AC3 110 Amp. (MAKE- L&T / SIEMENS / SCHNIEDER) |
| 25 | S/F of 3 Pole Power Contactor AC3 140 Amp. (MAKE- L&T / SIEMENS / SCHNIEDER) |
| 26 | S/F of Ampere meter (MAKE-AE/PROCOM/CONZERVE) |
| 27 | S/F of Voltmeter (MAKE-AE/PROCOM/CONZERVE) |
| 28 | S/F of APFCR Relay 5 Amp.,415 7 stage(MAKE-LT/IEMENS/ SCHNIEDER) |
| 29 | S/F of Under Voltage Coil(MAKE-LT/IEMENS/ SCHNIEDER) |
| 30 | S/F of Shunt Coile(MAKE-LT/IEMENS/ SCHNIEDER) |
| 31 | S/F of Cylindrical type heavy duty MPP Capacitor 15 KVAR @ 397 per KVAR( Make L & T/ SIEMENS/ SCHNIEDER) |
| 32 | S/F of Cylindrical type heavy duty MPP Capacitor 25 KVAR @ 388 per KVAR( Make L & T/ SIEMENS/ SCHNIEDER) |
| 33 | S/F of VPD Make soft Hard |
| 34 | S/F of MPD Make soft Hard |
| 35 | S/F WLC/seal monitor, make pump care/ kishor |
| 36 | S/F Control Transformer make Electra care/ Pioneer |
| 37 | S/F Winding Temp Relay Make Minilec |
| 38 | S/F Timer Make L & T Make |
| 39 | S/F of fully Automatic Control panel with 100 HP Auto Transformer for Submersible/VT Pump sets with following features No-Volt, Under voltage, Over voltage protection, Microprocesser based over load protection, Unbalancing protection, winding temperature controller, seal monitor, reverse rotation trip device and the automatic start/stop device according to the levels in the sump. The Contractor panels are provided with normal indications such as Digital voltmeter, digital Ammeter and indicating lamps. Above panel is dust and vermin proof made out of 14 SWG CRV sheet with powder coating paint as per directions of E/I( Make Contractor-L& T, MCCB-L &T, WTC Minilec, Auto Transformer- Electracare, VPd & MPD softhard,WLC/SM-Pump care C.T.-AE, Indicating Lught & Push Button-L & T, Control Fuse-EE, Fuse Base-EE, Timer- L & T. |
| 40 | Repair of 400 KVA Transformer including changing of HV & LV Coil, bushing Gaskit & fresh transfoemr oil without returning of old & unserclable material complete in all respects as per direction of E/I. |
| 41 | 250 KVA |
| 42 | S/L of aluminium conductor PVC insulated armoured served, sheathed cable 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75mm thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on MS clamps etc. of suitable size or as directed by Engineer-Incharge complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 400 sqmm 3½ core |
| 43 | 300 sqmm 3½ core |
| 44 | 120 sqmm 3½ core |
| 45 | 70 sqmm 3½ core |
| 46 | 50 sqmm 3½ core |
| 47 | S/F of palm or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tap and making connection etc. complete in all respect as per direction of E/I. 120 Sqmm |
| 48 | 300 Sqmm |
| 49 | 400 Sqmm |
| 50 | 70 Sqmm |
| 51 | 50 Sqmm |
| 52 | S/F Flat Cable of size copper finolex make : 25 Sqmm. 3 Core |
| 53 | S/F Flat Cable of size copper finolex make : 35 Sqmm. 3 Core |
| 54 | S/L of 3 core standered aluminium conductor XLPE (cross linked polythene) insulated PVC bedded, Galvanised flat steel strip aroured cable confirming to IS : 7098 (Part-II with latest amendmrnts) 11 KV grade at a depth of 900 mm below ground level over a cushion of 100 mm thick fine river sand alround and protected with well burnt bricks on sides and on top put across. The armourning of cable shall be properly connected with earth conductor by clamps etc. 95 sqmm 3 core |
| 55 | Providing & laying of M.S. pipes including collor for joint (Excluding flange) confirming to IS :3589 with latest amendment Gr.330/410/450 as situation of work at site according to IS code .Including cutting & welding as per site requirement complete in all respect as per direction o E/I. |
| 56 | 150mm dia, 4.5 mm thickness |
| 57 | 200mm dia, 6.3 mm thickness |
| 58 | 250mm dia, 6.3 mm thickness |
| 59 | 300mm dia, 7.3 mm thickness |
| 60 | Supply and laying of 1800 mmx900 mmx12 mm thick chequered rubber matting of tested quality. (PS No.-1136) |
| 61 | Supply and making indoor cable end termination with heat shrinkable jointing kit complete will all accessories inluding lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 120 Sqmm (indoor) |
| 62 | Supply and making outdoor cable end termination with heat shrinkable jointing kit complete will all accessories inluding lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 120 Sqmm (outdoor) |
| 63 | Supply and making outdoor cable end termination with heat shrinkable jointing kit complete will all accessories inluding lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 240 Sqmm (outdoor) |
| 64 | Supply and making indoor cable end termination with heat shrinkable jointing kit complete will all accessories inluding lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 240 Sqmm (indoor) |
| 65 | S/F of 11 KV TPMO Relco/Rama make 9 Nos. insulator of Jai shree/BHEL/Rama/ Rastriya make complete in all respects as per direction of E/I (UPERC-2019, I.No.-13, P.No.-48) |
| 66 | S/F of Steet tubular pole 11.0 Mtrs. Designated 410-Sp-56 in 1:3:6 cement, concrete graded stone aggregate of 40 mm n.s. & foundation i/c excavation, back filling complete in all respects as per direction of e/l at site.(UPERC-2019, I.No.-13, P.No.-24) Please Enable Macros to View BoQ information |