| 1 | DT (Supply Part) |
| 2 | 400KVA, 11/0.433kV, 3-phase Distribution Transformers (OLTC Type) with Bimetallic Terminal Connectors Energy Level- 2, and with LV Cable Box having detachable Aluminium Gland plate |
| 3 | Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type |
| 4 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type |
| 5 | 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 6 | 400mm² (2Ckt) Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type |
| 7 | 9 Mtr. Long Pole,ST-410 SP33) |
| 8 | 33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 9 | GI Channel/Angle/Flat of sizes including clamps |
| 10 | Galvinized Nuts and Bolts. |
| 11 | Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
| 12 | 33kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm |
| 13 | LT Distribution Box for 400KVA DTR with TPN MCCB short ckt rating 16 KA for incomer 630Amp(400KVA) and suitable 3 sets of MCCBs for outgoing (3x360Amp) circuits with terminal extensions |
| 14 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
| 15 | Wedge Connectors/PG Clamps |
| 16 | Danger Plates with Clamps |
| 17 | GI Barbed Wire for Anti Climbing |
| 18 | 3-Phase, HT Meter with CT PT and all other accessories including HT Cables, Termination kits (0.2S class, CTR 30/5) complete set (Smart/Conventional bidirectional Meter) |
| 19 | Cement bottoming 1:2:4 mix as per REC standards.5cum/pole |
| 20 | Painting of Poles Red Oxide |
| 21 | Painting of Poles Aluminium Paint |
| 22 | Sundry items like aluminium lugs, jumper binding Tape |
| 23 | Transformer Fencing completely covering the boundaries with angle iron, laying of gravels on the floor inside fencing. (Fencing of mesh size 2'X2', fencing size 15\\"X12\\"X6\\", fencing gate size 3\\"X6\\" completely painted and angle iron size 50X50X5mm ) |
| 24 | Concrete Transformer bed 6'X6'X6' |
| 25 | DT Installation/Testing/Commissioning Part) |
| 26 | 400KVA, 11/0.433kV, 3-phase Distribution Transformers (OLTC Type) with Bimetallic Terminal Connectors Energy Level- 2, and with LV Cable Box having detachable Aluminium Gland plate |
| 27 | Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type |
| 28 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type |
| 29 | 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 30 | 400mm² (2Ckt) Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type |
| 31 | 9 Mtr. Long Pole,ST-410 SP33) |
| 32 | 33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 33 | GI Channel/Angle/Flat of sizes including clamps |
| 34 | Galvinized Nuts and Bolts. |
| 35 | Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
| 36 | 33kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm |
| 37 | LT Distribution Box for 400KVA DTR with TPN MCCB short ckt rating 16 KA for incomer 630Amp(400KVA) and suitable 3 sets of MCCBs for outgoing (3x360Amp) circuits with terminal extensions |
| 38 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
| 39 | Wedge Connectors/PG Clamps |
| 40 | Danger Plates with Clamps |
| 41 | GI Barbed Wire for Anti Climbing |
| 42 | 3-Phase, HT Meter with CT PT and all other accessories including HT Cables, Termination kits (0.2S class) complete set (Smart/Conventional Meter) |
| 43 | Cement bottoming 1:2:4 mix as per REC standards.5cum/pole |
| 44 | Painting of Poles Red Oxide |
| 45 | Painting of Poles Aluminium Paint |
| 46 | Sundry items like aluminium lugs, jumper binding Tape |
| 47 | Transformer Fencing completely covering the boundaries with angle iron, laying of gravels on the floor inside fencing. (Fencing of mesh size 2'X2', fencing size 15\\"X12\\"X6\\", fencing gate size 3\\"X6\\" completely painted and angle iron size 50X50X5mm ) |
| 48 | Concrete Transformer bed 6'X6'X6' |
| 49 | HT Line (Supply Part) |
| 50 | 13 Mtr. Long Pole,ST-410 SP72) |
| 51 | 11 Mtr. Long Pole,ST-410 SP56) |
| 52 | 9 Mtr. Long Pole,ST-410 SP33) |
| 53 | GI V cross-arm/side cross with top Bracket including clamp as per specification(26kg/complete V-set/side cross) for 13Mtr Pole and 11Mtr pole |
| 54 | GI V cross-arm with top Bracket including clamp as per specification(14.631Kg/complete V-set) |
| 55 | 50 mm² ACSR Conductor |
| 56 | 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm |
| 57 | 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm |
| 58 | Galvinized Nuts and Bolts |
| 59 | Danger Plates with Clamps |
| 60 | Anti-Climbing Device with Clamps |
| 61 | Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip. |
| 62 | Red Oxide |
| 63 | Aluminium Paint |
| 64 | Cement bottoming 1:2:4 mix as per REC standards 0.7cum/pole |
| 65 | Cement bottoming 1:2:4 mix as per REC standards 0.6cum/pole |
| 66 | Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole |
| 67 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type |
| 68 | HT Line (Installation/Testing/Commissioning Part) |
| 69 | 13 Mtr. Long Pole,ST-410 SP72) |
| 70 | 11 Mtr. Long Pole,ST-410 SP56) |
| 71 | 9 Mtr. Long Pole,ST-410 SP33) |
| 72 | GI V cross-arm/side cross with top Bracket including clamp as per specification(26kg/complete V-set/side cross) for 13Mtr Pole and 11Mtr pole |
| 73 | GI V cross-arm with top Bracket including clamp as per specification(14.631Kg/complete V-set) |
| 74 | 50 mm² ACSR Conductor |
| 75 | 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm |
| 76 | 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm |
| 77 | Galvinized Nuts and Bolts |
| 78 | Danger Plates with Clamps |
| 79 | Anti-Climbing Device with Clamps |
| 80 | Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip. |
| 81 | Red Oxide |
| 82 | Aluminium Paint |
| 83 | Cement bottoming 1:2:4 mix as per REC standards 0.7cum/pole |
| 84 | Cement bottoming 1:2:4 mix as per REC standards 0.6cum/pole |
| 85 | Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole |
| 86 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type Please Enable Macros to View BoQ information |