| 1 | Replacement of light fitting with 19/20 Watt LED batten light fitting complete i/c connection testing etc as reqd.(M/sHavells or S/S make) |
| 2 | Replacement/repairing of following electrical accesseries i/c connection testing etc as reqd. (Approved make of BSNL) -- 5 amp piano type switch |
| 3 | 5 amp socket |
| 4 | 15 amp piano type switch |
| 5 | 15 amp socket |
| 6 | Ceiling fan condenser |
| 7 | Exhaust fan condenser |
| 8 | SP MCB C Series 5-32 Amp. |
| 9 | 40 A DP Isolator |
| 10 | Step type electronic fan regulator |
| 11 | 9 watt LED bulb with holder (M/s Havells/Anchor or S/S make) |
| 12 | 12 watt recess type LED type down light fitting complete |
| 13 | Rewinding of 18\\" exhaust fan i/c replacement of bearings etc |
| 14 | Rewinding of ceiling fan/wall fan i/c replacement of bearings etc |
| 15 | Replacement of faulty MCCBs/FN Switch and other electrical accesseries in MV/LT panel/Power room panel and EI panel i/c connection and testing etc as required.(Approved make of BSNL)---LED type Indication lamp |
| 16 | Three Phase Digital Ampere meter CT operated |
| 17 | Three Phase Digital Votmeter |
| 18 | FN 63 amp TPN switch with HRC fuse Cylinder fuse link Type HF ( M/s L&T or S/S make) |
| 19 | FN 200 amp FP switch with HRC fuse DIN type Fuse link Type HN ( M/s L&T or S/S make) |
| 20 | 400 Amp. Al. Bus Bar for MV Panel with colour sleeve i/c insulators etc |
| 21 | 200 Amp. TP MCCB 36 KA Th.range (134-200) Amp. (250 D) |
| 22 | 630 Amp. 4 Pole Change Over Switch (M/s L&T CO4-630 or S/S make) |
| 23 | Replacement of Heat detector i/c connection and testing etec as required (Approved make of BSNL) |
| 24 | Replacement of Photo type smoke detector i/c connection and testing etec as required (Approved make of BSNL) |
| 25 | Repairing/replacement of following faulty accesseries in AFD system i/c connection and testing etc as required (Approved make of BSNL) ----Control card |
| 26 | Zone card |
| 27 | Reasponse Indicator |
| 28 | 20 Watt Hooter |
| 29 | Manual Call Point |
| 30 | 18 AH sealed mntce. free battery |
| 31 | Replacement of following faulty accesseries of 1.5 TR Window/Splt AC unit for Small T.E. Bldgs.i/c connection, testing etc as reqd---Condensor |
| 32 | Blower motor for Split AC |
| 33 | Condensor motor for Split AC |
| 34 | Motor for Window AC |
| 35 | PCB card repairing |
| 36 | Charging of R-22 gas as per requirement including testing and commissioning etc. as required. |
| 37 | Replacement of existing HPSV fitting with 100 Watt Warm White Flood Light 240 Volt including connection with 2x 2.5 Sq.mm flexible cable etc. as required . (M/s Philips or S/S make) Please Enable Macros to View BoQ information |