| 1 | Dismantling of Demaged RCC Works including all cost of materoials and labour charges etc completed. |
| 2 | Dismantling of Demaged Brick or stone masonry in cement mortar, wall under 3m high up to 70cm Works including all cost of materoials and labour charges etc completed. |
| 3 | Hire charges for deploying earth moving machinery (JCB/Poclain) for earthwork including diesel, oil and labour charges etc., complete |
| 4 | Removal of Excavated Excess Earth away from the site to 5K.M including loading and transportation charges etc, complete as per standard specification. |
| 5 | Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete 10 cum |
| 6 | Footing |
| 7 | Plinth Bem |
| 8 | Supplying and filling in foundation and basement with Good Earth in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification. |
| 9 | Plain Cement Concrete 1:4:8 (one part of cement, four part of Crushed Stone Sand (M- Sand) and Eight part of coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification |
| 10 | Reinforced cement concrete M20 1:1.5:3 granite metal by volume, characteristic strength not less thab 20N/Sqmm machine mixed for all reinforced cement concrete works, including scaffolding, cost of all materials, machine mixing, vibrating, lifting, curing, labour charges for laying & finishing etc., but excluding the cost and fabrication of reinforcements and also excluding centering and formwork etc., complete complying with relevant standard specifications at all leads inside the building. |
| 11 | Footing |
| 12 | GROUND FLOOR |
| 13 | Supplying, cutting, bending and placing of reinforcement steel of MS, HYSD bars for all type of RCC works at all levels including cost of 18 guage GI binding wire cost, labour etc., as per design and details complete. |
| 14 | Supply and erecting shuttering including necessary supports for plane surfaces such as RCC column, footing, plinth beam, stair case etc., in all floors using mild steel sheets of 90cm X 60cm and 10 gauge stiffened with welded mild steel angle for boarding supported by casurina props at suitable intervals etc., completed complying with standard specification and as directed. Sl.No.122 |
| 15 | Supplying and erecting centering for sides soffits including supports and strutting upto 3.29m high for plain surface such as rectangular column top and bottom slabs of boxing, sill, slabs, sun shade etc., in all floors using mild steel slabs of sizes 90cm x 60cm and BG 10 stiffened with welded mild steel angles of size 25X25x3mm for boarding laid over country wood joists of size 10cm X 6.5cm spaced at about 90cm C/C and supported by casurina props of 10cm to 13cm dia spaced at 75cm C/C etc., complete as directed. Sl.No.123 C Part-II |
| 16 | Brick Work in Cement Mortor 1:5 Mix (one cement, five sand) using new best II Class Bricks of size 9 ” x 4 3/8 “x 2 3/4 ” from approved quarry including cost and conveyance of all materials to site. Loading and unloading charges and labour charges for mixing, laying and curing etc. complete. Complying with std. specifications |
| 17 | GROUND FLOOR |
| 18 | Brick Work in Cement Mortor 1:3 Mix (one cement, five sand) using new best II Class Bricks of size 9 ” x 4 3/8 “x 2 3/4 ” from approved quarry including cost and conveyance of all materials to site. Loading and unloading charges and labour charges for mixing, laying and curing etc. complete. Complying with std. specifications |
| 19 | GROUND FLOOR |
| 20 | Plastering in CM 1:3 mix 12mm thick including cost and conveyance of all materials and labour charges etc., complete |
| 21 | Plastering in CM 1:5 mix 12mm thick including cost and conveyance of all materials and labour charges etc., complete |
| 22 | Paving the floor with design Antiskirt ceramic tiles (colour and shade as directed) of size 305 mm x 305mm x 6 mm in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick laid in-situ and pointed with same coloured cement |
| 23 | Paving the floor with Double charged Vitrified tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer. The colour & quality of tiles should be got approved by Municipal Engineer before use on work |
| 24 | Daddoing the walls with first quality color glazed tiles of 300 x 450 x 6mm laid in CM 1:2 mix to 10mm thick and painting with white cement using 0.40kg/sqm includes joint finishing painting with tiles surface etc., complete. |
| 25 | Finishing the Floor with 20mm Cement concrete (Ellis pattern first sort - No sand to be used) etc., complete |
| 26 | Paving theTop of roof with Solar refelective ceramic tiles of size 305x 305x7mm thick of approved quality and colour laid in Cement mortar 1:3 (One cement and three crushed stones and )12mm thick and pointed with tile grout (Nitotile Groutor equivalent) and cement in the ratio of 1:3 for joint, curing etc., complete complying with standard specification and as directed by the departmental officers. |
| 27 | UPVC Ventilator Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of rame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work |
| 28 | FRP Door Sutter with FRP Door Frames made out of FRP Sheets of 3mm thick of over all size 65mm x 50mm with rebate suitably reinforced using MS Angle / Flats, cost of holdfasts and Solid Core FRP Shutter Panel of 5mm thick and hollow core frames of 3m wall thickness for styles and rails etc., of sizes specified by Engineers |
| 29 | Painting with plastic emulsion with paint two coats along with base coat of aprroval paint as per the standard specification. The paint to be used should be get approved by the Executive Engineer before use on work. |
| 30 | Painting new IRON WORKS for windows & Ventilators - Grills, steel bars screen, wire mesh and other similar works etc., with two coats of approval synthetic enamel paint over a base coat of red oxide primer in all floors and the rate inclusive cost of all materials & labours, brushes and scaffolding etc., complete complying with standard specification. The paint to be used should be get approved by the Executive Engineer before use on work. |
| 31 | Supply & fixing of European Water Closet with brand approval color including labour charges etc complete |
| 32 | Supply & fixing of Wash Basin of sizes 550 x 400 mm with all accessories such as cast iron brackets, 32mm dia CP wastage coupling, rubber plug and chain 32mm dia B class GI waste pipe, 15mm dia GM wheel valve 15mm dia Nylon connection, 15mm CP piller tap etc., complete |
| 33 | Supply & fixing of HDPE tank with approved brand and color etc., complete |
| 34 | Wiring with 2 x 15 Sq.mm (220/0.3) PVC insulated SC unsheathed CU conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush valve with 3mm thick hylum sheet cover with TW switch box and 5AFT switch with continous earth wire connection of 14 SWG TC wire for making good of concealed portion with suitable color PVC concealed light or fan point. (SD23) |
| 35 | Supply & fixing of single box tape 4'40W flu fitting complete with copper choke and condenser TW round blocks on wall ceiling with flu tube PVC unsheated copper test from terminals to be fitted etc., complete.(SD 88) |
| 36 | Wiring with 2 x 1.5 Sq.mm (220/0.3) PVC insulated SC unsheathed CU conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush valve with 150 x 100 x 113 mm with TW switch box with 3mm ticj hylum sheet cover for 5A.3Pln non inter locking CS plug with continuous earth wire connection of 14 SWG TC wire for making good of concealed portion with suitable color for concealed PV plug point etc., complete. (SD38) |
| 37 | Wiring with 2 x 4 Sq.mm (56/0.3) PVC insulated SC unsheathed CU conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush valve with 150 x 100 x 113 mm with TW switch box with 3mm ticj hylum sheet cover for 15A.3Pln non inter locking CS plug with continuous earth wire connection of 14 SWG TC wire for making good of concealed portion with suitable color for concealed PV power plug point etc., complete.(SD40) |
| 38 | Supply and fixing of WT bulk head fitting with guard suitable for 15 W LED Bulb of approved brand and quality with required materials like pipe, clamp etc., complete. |
| 39 | Supply & run off 2 x 1.5 sq.mm (22/0.3) pvc insulated SC unsheathed CU conductor of 1100V grade in rigid PVC pipe concealed in wall and ceiling with continous earth wire connection of 14SWG TC wire for making good of concealed portion with suitable color etc., complete. (SD 43) |
| 40 | Supply & run off 4 x 6 sq.mm (84/0.3) pvc insulated SC unsheathed CU conductor of 1100V grade in rigid PVC pipe concealed in wall and ceiling with continous earth wire connection of 14SWG TC wire for making good of concealed portion with suitable color etc., complete. (SD52) |
| 41 | Supply and fixing of grill with using 12mm dia square rod and iron flat all necessary material and labour charges for cutting,bending,welding and fixing etc complete |
| 42 | Supply & stacking of red earth at site to the departmental guage for pre-measurements which is of light textured, crystalline, porous and friable and of generally acidic or neutral but not alkaline and should be fertile, including seigniorage charges, cost of transportation, loading, unloading, stacking and inclusive of all taxes etc., complete. |
| 43 | Providing Plantation of Varieties of Flowering Plants incluidng etc complete as per the direction of the departmental officers incharge. |
| 44 | Supplying and laying in flooring with fully polished Sinthetic Grey colour Granite stone of 20mm thick (average) of 4' X 2' in size laid over base layer of cementmortar 1:3 (one cement and three Plastering sand) - 20 mm thick and applying cement slurry &pointed with white cement and colour pigments to the colour of stones and polished neatly as directed by the deparmental officers |
| 45 | Supplying and filling in foundation and basement with Good Earth in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification. |
| 46 | Supply and laying of 3 1/2 x 25 sq.mm PVC armoured Copper LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good etc completed. |
| 47 | Construction of Spong Park of Infletration Well including all cost of materials and labour charges etc completed. Please Enable Macros to View BoQ information |