| 1 | Dismantling fencing wire mesh, any type complete all as specified and directed. |
| 2 | Dismantling posts or struts (wood, steel or R.C.C.) embedded in concreteany section, including taking out embedded portion and making good disturbed ground complete all as specified and as directed. |
| 3 | Dismantling of wrought iron or mild steel work of any description not other wise provided for complete all as specified and directed. |
| 4 | S&F in repairs Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts,including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. Complete all as specified and as directed (each line wire to be measured). |
| 5 | S&F in repairs mild steel galvanised steel punched type concertina coil 600 mm dia (dia of coil when unstretched) and fix to angle iron with 3.15 mm dia GI wire complete all as specified and directed. |
| 6 | Excavating post holes or similar holes, each not exceeding 0.5 Cu. M, getting out in Soft/ Loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc 50m & making good surface complete all as specified and directed by Engr in Charge. |
| 7 | M&L for PCC 1:2:4 type B2 (using 40 mm graded crushed stone aggregate) as in foundation ,post, etc complete all as specified and directed by Engr in Charge. |
| 8 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc., including provision of binding wire. complete all as specified and directed by Engr in Charge. |
| 9 | Supply only Chain link MS galvanisd fencing, any size or type complete all as specified and directed. |
| 10 | S&F 10 mm dia mild steel TMT bar for fixing of chain link fencing with post complete all as specified and directed. |
| 11 | S&F 11 to 15mm dia of neck MS Screw bolts(Machine made ) with hexagonal or square heads at one end and screwed at other end or both end, and screwed end to be fitted with washer and one hexagonal or square n.exc 20 cm long etc complete all as specified and directed. |
| 12 | S&F mild steel framed work as in doors or gates of angle iron, door frame or other section with gusset plate, rails, braces etc complete, drilled for fixing of steel sheeting or other covering etc, to prepared for hanging or sliding with including either hooks and hinges also fastening grills, grating, hold fast of doors and windows chowkat etc, with ends of bars shouldered and or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walkways; railings; framework of water tanksand fixing and similar work confirming to fe 290 Gde E-165 including of dismantlinf of Timber structure if any complete all as specified and as directed. |
| 13 | S&F green/blue powder coated 4mm dia wire mesh fence system perimeter coated welded wire mesh fence steel panel of area n.exc 10 Sqm and mesh size as directed by Engr-in-Charge complete all as specified and as directed. |
| 14 | S&F powder coated post for 3D fence including all clamps,bolts, fittings,fixtures and size of post as decided by Engr-in-Charge complete all as specified and directed. |
| 15 | Demolition of cement concrete in ground floor and paving not exceeding 15cm thick (below or above ground level ) complete including removal of debries out side MD land complete all as specified and as directed. |
| 16 | M&L for PCC (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in sub base, levelling course, etc complete all as specified and as directed. |
| 17 | M&L for PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in sub base of floor, etc complete all as specified and directed. |
| 18 | M&L for 75mm thick cement concrete 1:3:6 type C1, with using 20mm graded stone aggregate as in floor/ plinth protection finish the surface even and smooth with using extra cement including filling the expansion joints with bitumen filler / filler boards and necessary form work etc complete all as specified and as directed. |
| 19 | Demolition of stone slabs and tiles of any description or thickness in floors complete all as specified and as directed. |
| 20 | M&L for chequered cement concrete tiles (glossy finished) with grey cement and pigment of size 25cmX25cmX25mm thick ,set and jointed and pointed in neat cement slurry in floor etc over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 21 | M&L for chequered cement concrete tiles (glossy finished) with grey cement and pigment of sizen.exc 0.16 sqm and 40mm thick ,set and jointed and pointed in neat cement slurry in floor etc over and including 15mm thick screed bed in CM 1:6 complete all as specified and as directed. |
| 22 | M&L for machine cut kota stone slab in flooring 20 to 25mm thick laid over and including 15mm thick screed bed in CM 1:6 & cement mixed with pigment to match the shade of slab including rubbing and laid over and including and polishing complete all as specified and as directed. |
| 23 | M&L for 60mm thick factroy made precast concrete interlocking paver block of M-35 Gde of approved shape (glossy finished), size and colour conferming to IS 15658-2006 and including joints filled with sand and 50mm thick stone dust as in levelling course of interlocking complete all as specified and as directed. |
| 24 | M&L for 80mm thick factroy made precast concrete interlocking paver block of M-40 Gde of approved shape (glossy finished), size and colour conferming to IS 15658-2006 and including joints filled with sand and 50mm thick stone dust as in levelling course of interlocking complete all as specified and as directed. |
| 25 | Dismantling of Asbestos cement (corrugated, semi-corrugated, etc.) sheets in roof coverings etc complete all as specified and as directed. |
| 26 | S&F 0.50mm thick (including coated thickness) pre-colour pre- profiled (Galvalume / zinkalume) sheets of required colour and design having tensile strength of 550 Mpa as in roof sheeting/sunshade/ wall cladding, north light curves, fixed with zinc coated self drilling fastener including EPDM washer complete laid with one corrugation side laps and min 150mm end lap laid to slope all as per manufacturer / profile maker instruction complete all as specified and as directed. |
| 27 | S&F 0.50mm thick (including coated thickness) pre-painted pre- profiled (Galvalume / zinkalume) sheets of required colour and design having tensile strength of 550 Mpa Plain sheet as in roof sheeting/sunshade/ wall cladding, north light curves, fixed with zinc coated self drilling fastener including EPDM washer complete laid with one corrugation side laps and min 150mm end lap laid to slope all as per manufacturer / profile maker instruction complete all as specified and as directed. |
| 28 | Dismantling of timber scantlings as in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section in un-framed work complete all as specified and directed. |
| 29 | S&F mild steel Hollow sections in tubular trusses, purlins, rafters, tubular columns, common rafters, running rails and similar structural members, including cutting, bending, drilling, welding, grinding, hoisting and erecting in position, complete with angle cleats, gusset plates, connection plates, special shaped washers, nuts, bolts and all other accessories required for proper connections, using ERW/Induction Butt Welded steel tubes conforming to IS: 4923 (latest revision) and IS: 1161, Grade ST-240 including welding and all fitting complete in all respects as specified and as directed by the Engineer-in-Charge. |
| 30 | S&F mild steel joists, channels, angles or tee sections, fixed independently without connecting plates, cleats, gussets or similar fittings, including cutting to ordinary lengths (within ±20 mm of the length indicated), aligning, positioning, welding, grinding of welds, drilling wherever required, hoisting, erecting and securing in position, complete, using steel sections conforming to relevant IS specifications and steel tubes, where applicable, conforming to IS: 1161, Grade ST-240, including welding complete in all respects as specified and as directed by the Engineer-in-Charge. |
| 31 | S&F mild steel plates (plain or chequered) of grade Fe 410 WA, in shoe plates, base plates, gusset plates and similar components for roof framework, trusses, rafters and other structural steel works, including cutting to size, drilling/punching holes, edge preparation, fitting and fixing in position, complete with necessary welding and/or riveting, bolts, nuts and washers as required, and all associated labour, materials, tools and tackles complete in all respects, all as specified and directed by the Engineer-in-Charge. |
| 32 | S&F Mild Steel framed work such as grills, gratings, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings, framework for water tanks and similar steel works, including cutting, straightening, bending, shaping, drilling, punching, notching, welding, riveting and assembling, with ends of bars shouldered and/or riveted or forged into spikes as required, complete with all fittings, fasteners, brackets, cleats and fixtures necessary for proper installation, using steel conforming to Fe 290 Grade E 165, including hoisting, erecting in position, welding and all fittings complete in all respects as specified and as directed by the Engineer-in-Charge. |
| 33 | M&L for preparation of newly steel surfaces, of any description, over 10 cm width or girth, and applying two coats of synthetic enamel paint over a coat of red oxide complete complete all as specified and as directed. |
| 34 | Desilting and cleaning of open drains of any shape and size manually, including removal of silt, sludge, mud, rubbish, solid and semi-solid deposits, vegetation growth, weeds, roots and all other foreign materials from the drain bed and sides, dressing and cleaning the drain to restore its original section and flow capacity, including collection, loading, transportation and disposal of excavated/desilted material at an approved dumping location exceeding 5.00 km from the edge of the drain, complete with all labour, tools, tackles, equipment and incidental works complete in all respects as specified and as directed by the Engineer-in-Charge. |
| 35 | Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles including removing debris outside MD land complete all as specified and directed. |
| 36 | M&L for brick work with flyash brick modular size, straight or curved on plan exc 6 m mean radius built in cm (1:6) complete all as specified and directed. |
| 37 | M&L for brick work with flyash brick modular size, straight or curved on plan any radius in half bricks thick wall built in cm (1:4) complete all as specified and directed. |
| 38 | M&L for stone walling of squared rubble, regular coursed,well bonded,bedded and solidly hearted, built in CM 1:4 complete all as specified and as directed. |
| 39 | M&L for PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in coping, cills, string courses, apex stone, bed plates, kerbs, bands, lintels n.exc 1.50m length etc including necessary form work, weathering, slightly rounded or chamfered angles and throating all as specified and directed. |
| 40 | M&L for 15 mm thick rendering with CM 1:4 on concrete surface finished with even and smooth without using extra cement complete all as specified and directed. |
| 41 | M&L for applying two coats of white wash on walls including preparation of newly plastered surfaces of wall/ceiling of any description complete all as specified and as directed. |
| 42 | M&L for cement concrete in surface channels and drains Type B2 1:2:4 (using 40 mm graded crushed stone aggregate) complete all as specified and as direced. |
| 43 | Extra for forming fair finished drain or channel of 30cm inner girth in cement concrete using extra cement including forms moulds etc all as specified. |
| 44 | S&F factory made steel fibre reinforced (SFRC) man holes covers with frame including necessary hold fast/hooks (medium duty) of 560 mm dia or rectangular of equivalent area including fixing with CM 1:4 and not less than 50mm thickness complete all as specified and directed. |
| 45 | S&F factory made steel fibre reinforced (SFRC) man holes covers without frame incl necessary hold fast/hooks (medium duty) of 560 mm dia or rectangular of equivalent area including fixing with CM 1:4 and not less than 50mm thickness complete all as specified and directed. |
| 46 | Dismantaling of floor hearth or wall tiling including cement mortar bedding (but not backing) and rubbish of the premisescomplete all as specified and directed. |
| 47 | M&L for coloured glazed ceramic joint free tiles area exc 0.11 sqm but n.exc 0.16 sqm and 8mm thick in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over & including 15mm thick screed bed in CM 1:6 complete all as approved and directed. |
| 48 | M&L for glazed coloured joint free ceramic tiles exc 0.11 sqm but n.exc 0.16 sqm and 8 mm thick, on vertical surfaces of wall such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 10mm thick rendering on stone masonry surfaces or surfaces other than fair faces of brick work in CM 1:4 complete all as specified and directed. |
| 49 | Taking down cement plaster on brick or stone or concrete surfaces of wall/ceiling etc , including raking out joints , hacking for key, scrubbing down with water etc. complete all as specified and directed. |
| 50 | M&L for stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the marble stone 10mm nominal size complete all as specified and directed.Note : (i) Payment for providing grooves shall be made separately (ii) Rate includes for any colour of marble stone and cement. |
| 51 | M&L for forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge. |
| 52 | Demolation of precast RCC jallies including raming of any description any in any position set in cement mortar complete all as specified and directed. |
| 53 | S&F precast cement concrete (1:2:4) louvers and jallies 25mm thick (measured solid) including all mouldings but excluding frame & set in CM 1:4 complete all as specified and directed. |
| 54 | M&L for preparation of new plastered wall surfaces and applying two coats of cement base paint on wall/RCC Jallies complete all as specified and directed. |
| 55 | M&L for precast reinforced cement concrete slab type B1, 1:2:4 (using 20mm graded stone aggregate) as in landing, drain cover slab ( for manholes etc ), chajjas, drain cover and shelves and similar articles with plain faces. (Reinforcement shall be measured & paid separatel) complete all as specified and directed. Please Enable Macros to View BoQ information |
| 56 | M&L for precast reinforced cement concrete slab type B1, 1:2:4 (using 20mm graded stone aggregate) as in landing, drain cover slab ( for manholes etc ), chajjas, drain cover and shelves and similar articles with plain faces. (Reinforcement shall be measured & paid separatel) complete all as specified and directed. Please Enable Macros to View BoQ information |