| 1 | Dismantling of wrought iron or mild steel of any description not otherswise provide for etc, complete all as specified and directed. |
| 2 | Dismantling of post or struts (wood /steel or RCC) any section including taking out embedded portion & making good disturbed ground, complete all as specified and directed. |
| 3 | Dismantling of barbed wire fencing of any description, complete all as specified and directed. |
| 4 | M&L for brick work with sub class 'B' bricks in straight or curved on plan exc 6m mean radius built in CM 1:6, including demolition of brickwork or stone/ boulder masonry, built in cement mortar, complete all as specified and directed.Note :- Work involves head load, no extra cost shall be borne by govt exchequer in r/o labour involved in this regard and if any sort of clearence from bushes is required. |
| 5 | All as per item No 4.00 here-in-before but except bricks. |
| 6 | M&L for stone walling of random rubble uncoursed well bonded bedded and solidly hearted in CM 1:6, including demolition of brickwork or stone/ boulder masonry, built in cement mortar, complete all as specified and directed |
| 7 | All as per item No 6.00 here-in-before but except stone. |
| 8 | M&L for reinforced cement concrete M-25 design mix (using 20mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc basement slabs, under-reamed piles and mass concrete and including demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for, complete all as specified and directed. |
| 9 | M&L for reinforced cement concrete M-25 design mix (using 20mm graded stone aggregate) for columns pillars, piers, posts and struts, and including demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for, complete all as specified and directed. |
| 10 | M&L for reinforced cement concrete M-25 design mix (using 20mm graded stone aggregate) for beams, cantilever, lintel over 1.5m span and including demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for, complete all as specified and directed |
| 11 | Use and waste for formwork of concrete foundation, footings, bases of coloumns, raft and rafts beams, sides soffits (if any) foundation and plinth beams and similar works for ruough finished of flate concrete surface etc, complete all as specified and directed. |
| 12 | Use and waste for formwork to sides and soffits of floor or roof beams beam haunching, lintel, cantilever etc, complete all as specified and directed. |
| 13 | Use and waste for formwork to sides of pillers, posts, struts, piers, coloumns, fair finished of surface concrete , square/rectangur etc, complete all as specified and directed. |
| 14 | S&F mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. |
| 15 | All as per item No 14.00 here-in-before but except 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders. |
| 16 | S&F of mild steel work in framed work such as in doors or gates grills, gratings, framed guard bars, ladders etc with ends of bars shouldered and/or riveted or forged into spikes and similar work confirming to Fe-410 as in framed and hung gates including pintle hinges, stops, hand made sliding bolts etc and similar work confirming to Fe-410-W, complete all as specified and directed. |
| 17 | M&L for rendering 15 mm thick in cm 1:4 on brick or concrete surfaces of wall, finished even and smooth without using extra cement and including taking down cement plaster etc including racking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed. Note:- Work involves head load, no extra cost shall be borne by Govt Exchequer in r/o labour involved in this regard and if any sort of clearence from bushes is required. |
| 18 | M&L for rendering 15 mm thick in cm 1:4 on fair faces of brick or concrete surfaces of wall, finished even and smooth without using extra cement, complete all as sepcifeid and directed.Note :- Work involves head load, no extra cost shall be borne by Govt Exchequer in r/o labour involved in this regard and if any sort of clearence from bushes is required. |
| 19 | M&L for rendering 15mm thick in cm 1:4 on stone masonry external surfces of wall, finished even and smooth without using extra cement, complete all as sepcifeid and directed. |
| 20 | Excavation in post holes (or similar holes) each n exc 0.5 cum getting out, returning filling in and ramming earth or broken rubble mixed with earh around in layer n exc 25cm watering & removing surplus soil to a distance n exc 50m & making good surface in soft/loose soil, complete all as sepcifeid and directed. |
| 21 | M&L for providing cement concrete type B-2 1:2:4 (using 40 mm graded stone aggregate) in foundation, filling and mass concrete as in posts, complete all as sepcifeid and directed. Please Enable Macros to View BoQ information |
| 22 | M&L for providing cement concrete type B-2 1:2:4 (using 40 mm graded stone aggregate) in foundation, filling and mass concrete as in posts, complete all as sepcifeid and directed. Please Enable Macros to View BoQ information |