| 1 | Earth work in excavation for foundation, trenches for pipes / cables or drains etc. by mechanical means / manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides, disposal of excavated earthincludingofall lift and lead upto 50m. Disposed earth to be levelled and neatly dressed.All kinds of soil. Vol-2 SOR Item No 2.6.1 |
| 2 | Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering All work up to plinth level. Cement concrete gradeM-15 (Nominal Mix) with 20 mm maximum size of stone aggregate. Vol-2 SOR Item No 4.1.3 |
| 3 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :Cement concrete grade M-20 (Nominal Mix)with 20mm maximum size of stone aggregate. Vol-2 SOR Item No 5.1.1 |
| 4 | Centering and shuttering including strutting, propping stretching etc. complete for and removal of formwork by sheet plateor plywood shuttering for : Vol-2 SOR Item No 19.1 |
| 5 | Foundations, footings, bases of columns, etc. For mass concrete.Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 6 | Walls (any thickness) including attached pilasters, butteresses, plinthand string courses etc Plinth Slab |
| 7 | Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 8 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands,plain window sills, staircases and spiral staircases upto floor two level excluding the cost of centering, shuttering and reinforcement with Cement concrete grade M-20 (Nominal Mix) with 20mm maximum size of stone aggregate. Vol-2 SOR Item No 5.3 |
| 9 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, postsandstrutsetc.above plinth level and up to floor two level excluding cost of centering, shuttering and reinforcement etc. Cement concrete grade M-20 (Nominal Mix) with 20mm maximum size of stone aggregate. Vol-2 SOR Item No 5.2.1 |
| 10 | Brickwork with flyash lime bricks (FALG Bricks) conforming to IS:12894- 2002, class designation 50 (average compressive strength) in super structure above plinth level up to floor 2 level including thecost of scaffolding :Cement mortar 1:4 (1 cement : 4 coarse sand) Vol-2 SOR Item No 6.14.1 |
| 11 | 15mm cement plaster on the rough side of single or half brick wall of mix:1:6 (1 cement: 6 sand) Vol-2 SOR Item No 13.2.2 |
| 12 | Reinforcement for R.C.C. workincluding straightening, cutting,bending, placing in position and binding upto floor level including costof binding wire, wastage and over laps upto 12mm horizontal/ inclinedposition of reinforcement bars in slab and beams, plinth, chajjas,lintels, upto 4.5m vertical length of reinforcement in wall columns (overlaps shall be provided as per requirement of IS : 13920; IS 456 & SP :34) etc. complete. Thermo-Mechanically Treated bars. (Fe 500 D or more) |
| 13 | 12 mm cement plaster of 13.1.1 - 1:4 (1 cement: 4 sand) mix : |
| 14 | Finishing walls with textured exterior paint of required shade New work (Two or more coats applied @3.28 ltr/10sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm. Vol-2 SOR Item No 13.43.1 |
| 15 | Providing and fixing chicken mesh as per ISI specificationand in the required width with 50mm long Bombay nails on vertical and horizontal junctions of RCC and brickwall including scaffolding and all lead and lift etc. complete before plastering upt 10 meter height. Vol-2 SOR Item No 13.73 |
| 16 | Forming groove of uniform size in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to theunder layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge 20 mm wide and 15 mm deep groove Vol-2 SOR Item No 13.67.2 |
| 17 | Wall painting with plastic emulsion paint of approved brand andmanufacture to give an even shade: Two or more coats on new work |
| 18 | ProvidingandlayingvitrifiedfloortilesMulti/Dobulecharged(Minimumtop layerthickness2.0mm)NenoPolishedselfdesign,indifferentsizewithwaterabsorptionlessthan0.05%andconformingtoIS:15622ofapprovedmakeinallcolours&shadesIstpreminumqualityinflooringlaidon12mmthickcementmortar1:4(1cement:4sand)includinggroutingthejointswithwhitecementandmatchingpigmentsetc.complete. (thickness as per manufacturer specification) |
| 19 | Providing and fixing pressed steel door frames confirming toIS: 4351manufactured from commercial mild steel sheet of 1.25mm thickness including hinges jamb, lock jamb, bead and if requiredangle threshold of mild steel angle of section 50x25mm, or baseties of 1.25mm pressed mild steel welded or rigidly fixedtogether by mechanical means, adjustable lugs with split end tailto each jamb including steel butt hinges 2.5mm thick with mortarguards, lock strike- plate and shock absorbers as specified andapplying a coat of approved steel primer after pre-treatment of thesurface as directed by Engineer-in-charge:Single rebate 100x50mm Vol-2 SOR Item No 10.12.2 |
| 20 | Providing and fixing ISI marked flush door shutters conforming to IS:2202 (Part I) decorative type, core of block board construction withframe of 1st class hard wood and well matched teak 3 plyveneering with vertical grains or cross bands and face veneers onboth faces of shutters using following hinges.35 mm thick including ISI marked Stainless Steel butt hinges withnecessary screws Vol-2 SOR Item No 9.18.1 |
| 21 | Providing and fixing factory made P.V.C. door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet mitred at corners and joined with 2 Nos. of 150mm long brackets of 15x15mm M.S. square tube, the vertical door profiles to be reinforced with 19x19mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100mm size complete as per manufacturers specification and direction of ngineer-in-Charge. Vol-2 SOR Item No 9.116 |
| 22 | 25mm thick PVC flush door shutters made out of a one piece Multichamber extruded PVC section of the size of 762mm X 25mm orless as per requirement with an average wall thickness of 1mm ± 0.3mm. PVC foam end cap of size 23x10mm are provided on both vertical edges to ensure the overall thickness of 25mm. An M.S. tube having dimensions 19mm x 19mm is inserted along the hinge side of the door. Core of the door shutter should be filled with High Density Polyurethane foam. The Top & Bottom edges of the shutter are covered with an end-cap of the size 25MM X 11MM. Door shutter shall be reinforced with special polymeric reinforcements as per manufactures' specification and direction of Engineer-in-charge to take up necessary hardware andfixtures. Stickers indicating the locations of hardware will be pasted at appropriate places Vol-2 SOR Item No 9.18.1 |
| 23 | Providing and fixing 16mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edge to give high gloss finish etc. complete at all levels.Granite of any colour and shade A rea of slab upto 0.50 sqm Vol-2 SOR Item No 8.2.6.1 |
| 24 | Steel work welded in built up sections/ framed work including cutting,hoisting, fixing in position and applying a priming coat of approvedsteel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gatesand similar works Vol-2 SOR Item No 10.14.1.2 |
| 25 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc. including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete i/c fixing the railing with necessary accessories and stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. ( for payment purpose only weight of stainless steel members shall be considered excluding fixing access) Vol-2 SOR Item No 11.43 |
| 26 | Structural steel work riveted, bolted or welded in builtupsections,trusses and framed work, including cutting, hoisting, fixingin position and applying a priming coa of approved steel primer allcomplete: |
| 27 | Providing corrugated G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.12.1.1 - 1.00mm thick with zinc coating not less than 275gm/m² |
| 28 | Circuit Wiring -Wiring for circuit wiring with PVC insulated cable FR with copper multistrand conductor ISI marked in concealed rigid P.V.C.conduit(HMS) ofISI marked suitable size including painting etc.as required as perspecification Vol-4 SORa) 2x2.5 Sq.mm. |
| 29 | Circuit Wiring -Wiring for circuit wiring with PVC insulated cable FR with copper multistrand conductor ISI marked in concealed rigid P.V.C.conduit(HMS) ofISI marked suitable size including painting etc.as required as perspecification Vol-4 SORb) 4x2.5 Sq.mm. |
| 30 | Light Point/Fan Points.a) Short point |
| 31 | Light Point/Fan Points.b) Medium point |
| 32 | Light Point/Fan Points.c) Long point |
| 33 | 3 Pin 6 Amp socket outlet on Separate Boarda) Short point |
| 34 | 3 Pin 6 Amp socket outlet on Separate Boardb) Medium point |
| 35 | 3 Pin 6 Amp socket outlet on Separate Boardc) Long point |
| 36 | Point wiring including metallic switch box, sheet, for 3 Pin 16 Amp. Socket Outlet Point With 4Sq.mm. PVC insulated cable FR with copper multi strand conductor ISI marked in Surface rigid P.V.C. Conduit (MMS) ISI Marked of suitable size including painting etc. with 16Amp. F.T. Switch & Socket /S.S. Combined 16Amp. of ISI Marked and 4Sq.mm. PVC insulated copper earth continuity conduct or of green colour inside conduit as per specification for On Separate Board |
| 37 | A. Short Point |
| 38 | B. Medium Point |
| 39 | C. Long Point |
| 40 | D. Extra Long -I |
| 41 | E. Extra Long -II |
| 42 | F. Extra Long -III |
| 43 | Same board socket 16 Amp. Vol-4 SOR Item No 1.5.4 |
| 44 | Modular switch boxes. Vol-4 sor item no 2.9Supplying and fixing of approved make modular type metal box withmodular frame / base plate and cover plate including fixing in concealed/ surface excluding switch, socket etc. as required for:- |
| 45 | 1 Or 2 Module |
| 46 | 4 Module |
| 47 | 6 Module |
| 48 | 8 Module |
| 49 | 12 Module |
| 50 | Circuit wiring in existing conduit / pvc casing capping. Vol-4 sor item no 4.3Supplying and drawing single core PVC insulated cable FR with copper multistrand conductor ISI marked in existing rigid conduit in surface or concealed as per specification |
| 51 | 2.5 Sq mm cable |
| 52 | 1 X 2.5 sq mm |
| 53 | 2 X 2.5 sq mm |
| 54 | 3 X 2.5 sq mm |
| 55 | 4.00 Sq mm cable |
| 56 | 1 X 4.00 sq mm |
| 57 | 2 X 4.00 sq mm |
| 58 | 3 X 4.00 sq mm |
| 59 | Sub mains in surface rigid steel conduit in copper conductor. Vol-4 sor item no 5.1 |
| 60 | Wiring for sub-mains with PVC insulated cable FR with copper multistrand conductor ISI marked insurface rigid steel ISI marked conduitof suitable size(conduit in cluded)including connection painting etc,asrequired as per specification3 WIRE SUB MAIN 6.0 sq mm cable in 25 mm conduit |
| 61 | Supplying of ISI Marked and accepted standard of Miniature Circuit Breaker (MCB) of 'C' series suitable for 240/415Volts, 50Cycle, 10 kA Value AC supply confirming to IS:8828:1996, IEC:60898 :2002 but without enclosures. Vol-4 SOR Item No 8.5 SINGLE POLE (SP)6 Amp to 32 Amp Rating |
| 62 | SINGLE POLE & NEUTRAL(SPN) 6 Amp to 32 Amp Rating |
| 63 | Supply of approved make powder coated sheet steel encloser SPN MCBDB inclusive of Busbar, Neutralbar, Earthbar & two earth terminal setc.complete as per IS:13032 (exclusive of MCB & isolator)- Vol-4 SOR Item No 8.5(B) 12 way double door |
| 64 | Supplying and installing of RCBOs (Residual current circuit breaker with over load and short circuit protection) ISI marked complete as per I.S. standard confirming to IEC:61009-2-1&IS:12640- 2:2001, 240/415V 50 Hz with 10kA short circuit with stand capacity for earth leakage, overload & short circuit protection including connection in existing enclosure in approved manner as per specification. Vol-4 SOR Item No 8.122 pole 32 Amps, 30 mA sensitivity |
| 65 | Fixing of MCB /MCCB/ Isolator. Vol-4 SOR Item No 8.16 Fixing of MCB / Isolator SP/DP in sheet steel enclosure as required as per accepted practice,includingmountingonbusbarandcableconnection etc. complete (Labour only ) |
| 66 | Labour charges for fixing sheet steel enclosure, MCBDB surface mounting type, as per accepted practice on 25x5mm flat iron clamps duly embedded in wall,cable connection etc. complete Vol-4 SOR Item No 8.17 |
| 67 | 8.5 (1) to 8.5 (4) |
| 68 | 8.5 (5) & 8.5 to 8.6 (2) |
| 69 | 8.6 (3), 8.6(4) & 8.7 (1) |
| 70 | Labour charges for fixing sheet steel enclosures, MCBDB flushmounting type, as per accepted practice, duly embedded and end plate completely flushed in wall, cable connection etc.completemounting type,as per accepted practice on 25x25x5mm angle ironclamp, including supplying and fixing of clamps duly embedded inwall, cable connection etc. complete. Vol-4 SOR Item No 8.19 |
| 71 | 8.5(1) to 8.5(5), 8.6(1) to 8.6 (5) & 8.7(1 |
| 72 | Suppling and fixing of approved make step type Modular electronic, Fan regulator single / double module including connection etc. as required on existing board. Vol-4 SOR Item No 9.31 450 Watt |
| 73 | Supplying, erection and testing of approved make electric Ceiling fan ofdouble ball bearing complete with standard down rod, canopy, hangingshackle, Aluminium blades, without regulator, A.C.230-250volts including connections with all necessary material completed as required confirming to IS :374/1979 with upto date ammendments. Vol-4 SOR Item No 9.32Ceiling Fan (Energy Saver 50 W)-1200 mm Sweep |
| 74 | Supplying, erecting and testing of approved make Exhaust Fan heavy dutywith mounting frame, blades AC230-250 complete connection and including, frame bolt/ Anchor hole fastners etc. complete finished and as required. Vol-4 SOR Item No 9.36380mm sweep 900 RPM |
| 75 | Supplying, fixing and testing of approved make fluorescent tube fitting 36/40 watt,rust resistant, stove enamelled paint, boxtype channel with cover, complete with electronic ballast (HF complete duly wired (without tuberod) as per specification & fixing as below: Vol-4 SOR Item No 9.38I)Fixing on wall / Ceiling on wooden round block with 'J' hook / Anchorhole fastners / hollow bow with rod fixed in Ceiling and other necessary materials including connections etc. and as required. |
| 76 | BULK HEAD Supplying, fixing and testing of approved make bulk head luminaire consisting of pressure die aluminium housing lamp holder, prismatic glass cover, rubber gasket and wire guard, delux type, including fixing on wall as required, with necessary material complete Fitting(sutiable for GLS w/o lamp upto 11 watt Retorted CFLVol-4 SOR Item No 9.45 |
| 77 | Supplying, fixing and testing of approved make high pressure M.V. fitting, consisting of cast aluminium cotrol gear housing, highly polished reflector, highly transparent acrylic hinged cover, complete with taped polyster choke, capacitor, connectoretc. suaitable for end mounting duly wired (without lamp) including fixing with 25/30 mm dia G.I. pipe medium class of required length upto 2 Meter for mounting on wall / existing pole /on existing 'D' bracket, including bending the pipe to required shape and connections including all materials as required. Vol-4 SOR Item No 9.46125 Watt |
| 78 | Supplying, fixing & testing of approved make of T-5 lamp channel luminaire with plastic extruded housing within- built electronic control gear with decorative end caps with necessary materials connection etc.complete as required (with lamp). Vol-4 SOR Item No 9.57 T - 5 Lamp 1 X 28 watt |
| 79 | Supply of XLPE Insulated power cable (conforming IS-7098) 1100 Volt grade / Heavy duty power cable conforming to IS 1554-1100 Volts grade, 2core / 3½core / 4core ISI MARKED with Alu. Stranded /solid conductor. Vol-4 SOR Item No 14.1 ARMOURED 3 Core 10 Sq.mm.(XLPE |
| 80 | Providing and erecting expoxy resin end termination / joint for low tension P.V.C. / XPLE insulated cable of 1100Volt grade complete with cable jointing compound, Harner, Plastic mould adhesive cum solvent expoxy putty, spacer, tapes etc. as per I.S. specification 8438.1977 for cable duty erected on existing pole / support / switch gears and connection to supply for all core cable as under. Vol-4 SOR Item No 14.5.1id/od epoxy resin end terminationa. 10-50 sq.mm. 2 / 3 / 3/½ |
| 81 | BRASS COMPRESSION GLAND. Vol-4 SOR Item No 14.6Gland Size 22mm suitable for cable 2, 3, 3½, 4 x 10Sq.mmor 2x 16 Sq.mm |
| 82 | Supplying and fixing cramping type Alum. lugs as per I.S.S. Specification suitable for following size of cable with Alu. / Copper solid / stranded conductor evently cramped with high/pressure tool and connected to switch gear / Bus / M.C.C.B. / M.C.B. etc. as required complete. For Conductor Size. Vol-4 SOR Item No 14.86mm to 16 Sq.mmEach5.00 |
| 83 | Providing & Erecting PVC surface or pendent mounting LED bulk type 9 watt lighting fitting with electronic driver. And lumen output from luminaire 720 lm, input voltage range 90-300VAC, 50 Hz cool white (3000 to 6500k), in-built driver, -20 Degree to +60 Degree working temperature, AL frame with beam angle 120 deg. |
| 84 | Supplying and erecting LED street light / Flood light fittings with High power White LEDs wattage of 3 Watt and above assembled on single MCPCB, efficiency more than 130 lm/w and corrosion free High pressure die cast aluminum housing with smooth finish powder coated and heat sink extruded aluminium with diffuser and Polycarbonate optics/ lenses, with toughened glass with company mark/name engraved or embossed 160 to 270 V,Power Factor more than 0.95, THD < 10 %, CCT 3000 K to 5700K,Uniformity ratio >0.45, Luminaire efficacy> 100 lumens/watt . LED driver efficiency > 85 %.( fittings required LM-79 & LM-80 certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity between the ranges shown.)(A) Street Light (IP-65), Surge protection -4KV integral and ,Light must have 440VAC line supply with over-voltage protection. 6mm to 16 Sq.mmEach5.00 Please Enable Macros to View BoQ information |