| 1 | Lumpsum price worked out by the tenderer for BUILDINGS AND STRUCTURES as listed in Schedule ‘A’ Part-I |
| 2 | Lumpsum price worked out by the tenderer for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-II |
| 3 | Lumpsum price worked out by the tenderer for INTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-III |
| 4 | Lumpsum price worked out by the tenderer for SITE CLEARANCE AND DEVELOPMENT as listed in Schedule ‘A’ Part-IV |
| 5 | Lumpsum price worked out by the tenderer for ROAD/ PATH/ CULVERT as listed in Schedule ‘A’ Part-V |
| 6 | Lumpsum price worked out by the tenderer for AREA DRAINAGE as listed in Schedule ‘A’ Part-VI |
| 7 | Lumpsum price worked out by the tenderer for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-VII |
| 8 | Lumpsum price worked out by the tenderer for RAIN WATER HARVESTING as listed in Schedule ‘A’ Part-VIII |
| 9 | Lumpsum price worked out by the tenderer for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-IX |
| 10 | Lumpsum price worked out by the tenderer for EXTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-X |
| 11 | Lumpsum price worked out by the tenderer for HOT WATER SUPPLY as listed in Schedule ‘A’ Part-XI |
| 12 | Lumpsum price worked out by the tenderer for COOLING APPLIANCES & ELECTRIC CHIMNEY as listed in Schedule ‘A’ Part-XII |
| 13 | Lumpsum price worked out by the tenderer for FIRE FIGHTING & FIRE ALARM SYSTEMS as listed in Schedule ‘A’ Part-XIII |
| 14 | SCHEDULE 'A' PART XIV (MISCELLANEOUS ITEMS)Note: This schedule is not pre-priced by MES |
| 15 | INTERNAL WATER SUPPLY |
| 16 | Supply & Fix 15mm bore concussive push button taps, brass, chromium plated screwed for iron pipe complete all as specified and directed. |
| 17 | Supply and fix health faucet (Hand shower) chromium plated with 1.0 metre long easy flex tube 8mm dia with wall hook as per screwed for 15mm stop cock etc complete all as specified and as directed.Make: Cat No. ALD-CHR-583 of Jaquar or T9940A1 of Parryware or F-8030105 -AB of CERA or equivalent model in other specified makes in PS |
| 18 | Supply and fix Two way angle cock 15mm bore, brass, chromium plated with wall flange, screwed down ,high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. |
| 19 | Supply and fix Sink cock 15mm bore, brass, chromium plated wall mounted type with wall flange, with regular swinging spout, screwed for iron pipe or for unions and fixed complete all as specified and directed.Make: Cat No. ALI-CHR-39347S of Jaquar or F650023CP of Hindware or K29308INCP of Kohler or equivalent model in other specified makes in PS |
| 20 | INTERNAL ELECTRIC SUPPLY |
| 21 | M&L for Point wiring complete with 1.5 sq mm single core PVC insulated FRLS unsheathed cable 1100 volts grade with multi stranded copper conductor confirming to IS-694 1990 wih ISI marked (for phase, neutral and earth) in and including PVC conduit with ISI Mark of minimum 20mm dia and all conduit accessories concealed in wall/ceiling etc and including factory made branded make embossed glvanised steel pressed terminal sunken boxes alongwith suitable size modular cover plates with frames for fixing modular switches and sockets, fan regulators etc. of suiable size modules and the earth wire to be connected to common earth dolly complete all as specified and directed for the following :- |
| 22 | One light point /Ceiling Fan Point /Exhaust fan Point controlled by one modular switch 6A |
| 23 | One light point controlled by two Nos. of two way modular switch 6A |
| 24 | One 3 pin socket outlet 6 A on same board with other switches |
| 25 | One 3 pin socket outlet 6 A on Independent board |
| 26 | M&L for Point wiring complete all a specified with 1100 Volts grade 2.5 sq mm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor conforming to IS 694 1990 with ISI marked (for phase, neutral and earth) in and including PVC conduit ISI Mark of minimum size 20mm dia all accessories concealed in wall/ceiling/fixed to roof/ truss/ columns etc and including factory made branded make embossed galvanised steel pressed terminal sunken boxes for fixing modular sockets of suitable size modules and the earth wire to be connected to common earty dolly for One three pin modular switch socket 16 amps outlet on independent board all as specified and as directed. |
| 27 | M&L for Point wiring complete all a specified with 1100 Volts grade 4 sq mm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor conforming to IS 694 1990 with ISI marked (for phase, neutral and earth)in and including PVC conduit ISI Mark of minimum size 20mm dia all accessories concealed in wall/ceiling/fixed to roof/ truss/ columns etc and including factory made branded make embossed galvanised steel pressed terminal sunken boxes for fixing modular sockets of suitable size modules and the earth wire to be connected to common earty dolly for One three pin modular switch socket 20 amps outlet on independent board all as specified and as directed. |
| 28 | Supply and fixing Modular type 1 module Co-Axial TV Socket complete all as specified and as directed. |
| 29 | Supply and fixing factory made epoxy powder coated MCB distribution board VTPN 6 ways with metal double door (IP-43 protection) fabricated with minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, stranded DIN rail, earth bar and cable ties for cable management, cable connection with copper lugs top and bottom removable gland plates with Knockouts and suitable for one FP MCCB upto 63 Amps as incomer and suitable for SP/TP MCBs (or any combination) outgoings complete all as specified & directed. |
| 30 | Supply and fixing LED down light fitting, surface type, 12W, 220V, AC having luminous efficiency of >100, input voltage range of 140-270 V, input frequency range 50-60 Hz connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified & directed. |
| 31 | Supply and fixing LED study light fitting 6W, 220V, AC having luminous efficiency of >100, input voltage range of 140-270 V, input frequency range 50-60 Hz connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified & directed. |
| 32 | Supply and fixing Flameproof LED tube light fitting, surface type, 12W, 220V, AC having luminous efficiency of >100, input voltage range of 140-240 V, input frequency range 50-60 Hz, surge voltage protection 4 KVA, CCT 5500 to 6500K CRI > 70%, Glass type Borosilicate, steel cable entries M20-2 Nos. Material of construction AI Die Cast, Area of classification Zone-1, Zone-2, Gas group, gas group IIA/ IIB/ IIC made of AI die cast, ingress protection IP 66, temperature class T6, Class Zone 1&2 certification CIMFR Dhanbad & PESO Nagpur, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified & directed. |
| 33 | Supply and fixing Flame proof Exhaust fan steel body, complete with louvers shutter, 300mm sweep, voltage 230V, 50 Hz, RPM 1200, Copper winding, gas group IIA/ IIB made of AI die cast, ingress protection IP 66, temperature class T6, Class Zone 1&2 certification CIMFR Dhanbad & PESO Nagpur, conforming to IS 1293: 2005 complete all as specified as directed. |
| 34 | Supplying, installing, testing and commissioning of MLTP Panel (TTA) |
| 35 | Supply and fixing sub main wiring in repairs with 2 runs of 2.5 sqmm and 1 run of 2.5 sqmm FRLS PVC insulated, 1100 volts grade single core multistranded copper conductor cable conforming to IS specifications for phase, neutral and earth wire drawn through & including medium grade PVC conduit of suitable size and conduit accessories concealed in wall or on wall surface, connecting to common earth dolly all as specified and directed.Note : Three single core 2.5 sqmm and PVC conduit shall be measured as one unit |
| 36 | Supply and fixing sub main wiring in repairs with 2 runs of 4 sqmm and 1 run of 4 sqmm FRLS PVC insulated, 1100 volts grade single core multistranded copper conductor cable conforming to IS specifications for phase, neutral and earth wire drawn through & including medium grade PVC conduit of suitable size and conduit accessories concealed in wall or on wall surface, connecting to common earth dolly all as specified and directed.Note : Three single core 4 sqmm and PVC conduit shall be measured as one unit |
| 37 | Supply and fixing sub main wiring in repairs with 2 runs of 6 sqmm and 1 run of 6 sqmm FRLS PVC insulated, 1100 volts grade single core multistranded copper conductor cable conforming to IS specifications for phase, neutral and earth wire drawn through & including medium grade PVC conduit of suitable size and conduit accessories concealed in wall or on wall surface, connecting to common earth dolly all as specified and directed.Note : Three single core 6 sqmm and PVC conduit shall be measured as one unit |
| 38 | Supply and fixing sub main wiring in repairs with 4 runs of 10 sqmm and 1 run of 10 sqmm FRLS PVC insulated, 1100 volts grade single core multistranded copper conductor cable conforming to IS specifications for phase, neutral and earth wire drawn through & including medium grade PVC conduit of suitable size and conduit accessories concealed in wall or on wall surface, connecting to common earth dolly all as specified and directed.Note : Five single core 10 sqmm and PVC conduit shall be measured as one unit |
| 39 | M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth lead wire 4 mm dia as earth lead with 15mm bore GI protection pipe up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 2010 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, 40mm thick pre cast RCC (1:2:4) type B1 cover slab with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 40 | M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth lead wire 4 mm dia as earth lead with 15mm bore GI protection pipe up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 2010 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, 40mm thick pre cast RCC (1:2:4) type B1 cover slab with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed. Please Enable Macros to View BoQ information |