| 1 | Schedule-A |
| 2 | Supply and fix in repairs MS pipe fitting as bends, tees, collar, branch pieces, cap & plug etc, both ends flange welded complete with replacement of nuts and bolts all as specified and directed by Engineer-in-Charge |
| 3 | Supply and fixing in replacement of MS ERW pipe C class of 300 mm dia including jointing and testing as per manufacturer's instructions complete all as specified and as directed. |
| 4 | Supply and fixing in replacement of MS ERW pipe C class of 150 mm dia including jointing and testing as per manufacturer's instructions complete all as specified and as directed. |
| 5 | Supply and fixing in replacement of MS ERW pipe C class of 100 mm dia including jointing and testing as per manufacturer's instructions complete all as specified and as directed. |
| 6 | Dismantling of existing water header of size 300 mm dia and length of 6.5 Rm including cutting and dismantling of welding from supply and distribution line ( Supply line 150 mm -04 Nos, Distribution line-150 mm -02 Nos and 100 mm -04 Nos) by arranging crane or suitable labour as required for lifting the unserviceable header aside including dismantling existing pcc and and supply and fixing of new header with necessary cutting in 300 mm line, 150 mm line, 100 mm line and necessary welding works including fixing of flanges with rubber gasket and nut bolts complete for wrater connection as dismantled above and as directed and making PCC foundation for support of Header (Note : MS pipe for header of different will be measured seperately) checking for satisfatory working all as directed by EIC. Note : Job for replacement of header shall be done with gurantee during the contract period and any defects after fixing shall be rectified by the contractor at his own cost. |
| 7 | (i) Dewatering the tank/UG Sump with portable submersible pump set with flow rate of 30,000 ltrs per hr. (ii) Removal of left over dirty water and sludge with special sludge removal pump set having capacity up to 1.7 lakh ltrs per hr. (iii) Cleaning of wall ceiling and floor by high pressure rotary water jet with the help of German equipment which create pressure of 80-120. (iv) Removing of remaining sludge from the floor with the help of industrial vaccum cleaner. (v) Spraying of non toxic biodegraded eco friendly anti bacterial agent certified by a Govt approved lab to disinfect the tank from harmful pathdons. The dose utilise should be as per OECD guide No 432 .(vi) Treatment of inside tank be exposing UV radiation kill the suspended or floating bacterial remaining in the tank(vii) The cleaning of water reservior will be done two times on half yearly basis.(viii) Cleaning and removing all scale & dirt from bottom & walls and from mouth of circulation pipes of overhead tank of any capacityat staging height exceeding 15 metre and not exceeding 21.5 metre and disinfecting chemical the same using disinfecting chemical (chlorine) complete. |
| 8 | (a) Service PVC tank of capacity of 10,000 Ltrs each. |
| 9 | (b) Under Ground Sump 2,000,00 gallons capacity |
| 10 | (c) Under Ground Sump 1,000,00 gallons capacity |
| 11 | (d) Under Ground Sump of 25,000 gallons capacity |
| 12 | (e) OH reservoir upto 50000 gallons capacity |
| 13 | (fe) OH reservoir upto 1.75 Lakhs gallon capacity |
| 14 | Supply and fix in replacement of water level indicator of electronic type with PVC insulated copper conuctor for indicating water level. |
| 15 | Supply and fix in replacement of water meter of analog type in 150mm CI pipeline line. |
| 16 | M & L for MS plate /sheet plain or chequered, cut to pieces as required and fixed to MS frame work by means of Electric arc/gas welding all as directed and specified. |
| 17 | Taking down cast iron /DI/GI water mains including burning out joints and recovering lead size of bore 150mm complete all as specified & directed by Engineer-in-charge. |
| 18 | Taking down cast iron water mains including burning out joints and recovering lead size of bore 100mm complete all as specified & directed by Engineer-in-charge. |
| 19 | Supplying, and laying and testing in trenches, jointing/ connecting and testing 150mm bore ductile iron pipe class 'k-7' with spigot and socketed ends, centrifugally cast suitable joint complete, all as specified and directed by Engineer-in-Charge. |
| 20 | Supplying, and laying and testing in trenches, jointing/ connecting and testing 100mm bore ductile iron pipe class 'k-7' with spigot and socketed ends, centrifugally cast suitable joint complete, all as specified and directed by Engineer-in-Charge. |
| 21 | Supply, laying, jointing & testing in replacement in trenches cast iron pipes 150 mm bore with spigot and socketed ends centrifugally cast (spun cast) class LA suitable for tyton joints complete all as specified and directed.Note:- Earth work, Joints and CI specials/ fittings of the pipes shall be measured and paid for separately under appropriate item. |
| 22 | Supply, laying, jointing & testing in replacement in trenches cast iron pipes 100 mm bore with spigot and socketed ends centrifugally cast (spun cast) class LA suitable for tyton joints complete all as specified.Note:- Earth work, Joints and CI specials/ fittings of the pipes shall be measured and paid for separately under appropriate item. |
| 23 | Excavation in trenches in any type of soil i.e. loose/soft not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in width and getting out complete all as specified and as directed by Engineer-In-Charge. |
| 24 | Returning, filling and including spreading, leveling and watering and well ramming in layers not exceeding 25 cm to achieve desired compactness as directed by Engineer-In-Charge. |
| 25 | Removing of excavated material/soil to a distance not exceeding 50 Mtrs and depositing at a level not exceeding 1.5 Mtr above the starting point all as directed by Engineer-In-Charge. |
| 26 | M &L for demolition of cement concrete in ground floors and pavings n.exc 15 cm thickness (below or above ground level) |
| 27 | M&L for PCC 1:3:6 type C-1 ( using 20 mm graded stone aggregates) for repairing of valve chamber foundation etc including filling in road cuts/ hard standing etc all as specified and as directed. |
| 28 | Supply, laying, jointing and testing in replacement in trenches, galvanized iron water tubing of sie 50 mm bore medium grade including provision of all necessary ISI marked GI fittings / accessories complete all as specified and directed . |
| 29 | Supply, laying, jointing and testing in replacement in trenches, galvanized iron water tubing of sie 40 mm bore medium grade including provision of all necessary ISI marked GI fittings / accessories complete all as specified and directed. |
| 30 | Supply, laying, jointing and testing in replacement in trenches, galvanized iron water tubing of sie 32 mm bore medium grade including provision of all necessary ISI marked GI fittings / accessories complete all as specified and directed. |
| 31 | Supply, laying, jointing and testing in replacement in trenches, galvanized iron water tubing of sie 25 mm bore medium grade including provision of all necessary ISI marked GI fittings / accessories complete all as specified and directed. |
| 32 | Supply, laying, jointing and testing in replacement in walls and ceilings or laid in floors , galvanized iron water tubing medium grade 25 mm bore including provision of all necessary ISI marked GI fittings / accessories complete all as specified and directed. |
| 33 | Supply, laying, jointing and testing in replacement in walls and ceilings or laid in floors , galvanized iron water tubing medium grade 20 mm bore including provision of all necessary ISI marked GI fittings / accessories complete all as specified and directed. |
| 34 | Supply, laying, jointing and testing in replacement in walls and ceilings or laid in floors , galvanized iron water tubing medium grade 15 mm bore including provision of all necessary ISI marked GI fittings / accessories complete all as specified and directed. |
| 35 | Supply, fixing, jointing and testing in replacement of ISI Marked, of approved quality, gun metal globe/gate valve of size 50 mm bore with iron wheel head, both ends screwed for iron pipe complete all as specified and directed. |
| 36 | Supply, fixing, jointing and testing in replacement of ISI Marked, of approved quality, gun metal globe/gate valve of size 40 mm bore with iron wheel head, both ends screwed for iron pipe complete all as specified and directed. |
| 37 | Supply, fixing, jointing and testing in replacement of ISI Marked, of approved quality, gun metal globe/gate valve of size 25 mm bore with iron wheel head, both ends screwed for iron pipe complete all as specified and directed. |
| 38 | Supply, fixing, jointing and testing in replacement of ISI Marked, of approved quality, gun metal globe/gate valve of size 20 mm bore with iron wheel head, both ends screwed for iron pipe complete all as specified and directed. |
| 39 | Supply, fixing, jointing and testing in replacement of ISI Marked, of approved quality, gun metal globe/gate valve of size 15 mm bore with iron wheel head, both ends screwed for iron pipe complete all as specified and directed. |
| 40 | M&L for cutting the existing bitumen us road/payment/footpath upto 0.75 mtr in depth, 0.45 mtr in width and getting out excavated material and making good the damaged portion after laying the pipe, returning filling in mass concrete PCC 1:2:4 type B2 upto top of the road all as directed by Engr-in-Charge. Note :-(i) M&L for laying of pipe shall be measured and paid separately. |
| 41 | M&L for complete rewinding of electric motor with super enameled copper wire of superior quality as per existing gauge including vanishing, insulating material complete all as directed and greasing, oiling etc and including reassembling fixing in position making connection testing, commissioning & transporting complete. Note :- rewinding shall be done with gurantee during the contract period. Any defects after rewinding shall be rectified by the contractor at his own expanses. |
| 42 | Supply, connection and testing of submersible cable copper conductor 3 core 1100 Volt grade 4 sq mm nominal cross sectional area including disconnecting the old u/s cable complete all as specified and directed by Engr-in-charge. |
| 43 | M&L for Annual maintance contract visit for RO plant capacity 5000 Ltr/hr, at 13 BRD domestic area including servicing, overhauling & repair if any required with replacement of all unserviceable parts complete all as specified and as directed by Engineer-In-Charhe. Note:- The RO plant maintained in serviceable condition through out the contrat period and any complaint regarding unserviceablilty of shall be rectified within 48 hrs panelty @ Rs 2000/- day shall be deducted from contractors dues till rectification on complaint. (A) Comprehensive AMC for RO Plant & its Equipment Capacity 5000 Ltr/hr :- (i) MGF -01 No (ii) Dosing Pump -01 (iii) RO Plant Complete 5000 ltr/hr -01 (B) scope to be covered under AMC :- (i) Provision of training to operate the above System (ii) Submission of the preventive Maintenance Chart for the Month (iii) Cleaning operation for RO Membrane with all consumable/Chemicals (iv) Monthly cheacking of Cartidge, If cartridge shall be required, the supplier will arrange the same (v) Arrangment for probing of RO inter stage once in a month, resetting of 'O' ring in board connector etc to be arranged, if Required (vi) Maintenance/trouble shooting of high pressure pump Necessary spares will be arranged by Suppliers,if Required (vii) Fault detection procon Pump/high prssure pump Please Enable Macros to View BoQ information |
| 44 | M&L for Annual maintance contract visit for RO plant capacity 5000 Ltr/hr, at 13 BRD domestic area including servicing, overhauling & repair if any required with replacement of all unserviceable parts complete all as specified and as directed by Engineer-In-Charhe. Note:- The RO plant maintained in serviceable condition through out the contrat period and any complaint regarding unserviceablilty of shall be rectified within 48 hrs panelty @ Rs 2000/- day shall be deducted from contractors dues till rectification on complaint. (A) Comprehensive AMC for RO Plant & its Equipment Capacity 5000 Ltr/hr :- (i) MGF -01 No (ii) Dosing Pump -01 (iii) RO Plant Complete 5000 ltr/hr -01 (B) scope to be covered under AMC :- (i) Provision of training to operate the above System (ii) Submission of the preventive Maintenance Chart for the Month (iii) Cleaning operation for RO Membrane with all consumable/Chemicals (iv) Monthly cheacking of Cartidge, If cartridge shall be required, the supplier will arrange the same (v) Arrangment for probing of RO inter stage once in a month, resetting of 'O' ring in board connector etc to be arranged, if Required (vi) Maintenance/trouble shooting of high pressure pump Necessary spares will be arranged by Suppliers,if Required (vii) Fault detection procon Pump/high prssure pump Please Enable Macros to View BoQ information |