| 1 | Taking down of existing Water Proofing treatment of any type i.e., APP Membrane,Cement or earthen tile,Mud phuska or lime concrete including cement plaster of any thickness and removing bitumen coating /mud pushka dirts etc over original RCC roof slab by grinding, picking, sweeping clean and washing down with water to remove dust to providing water prooling treatment complete.(Note : Rate includes for removing debris outside defence land of distance exc 500m but not exc 1000m) |
| 2 | M&L for Plain cement concrete (1:2:4) type B-0 using 12.50mm graded stone aggregate as in copings, parapets and railing upto 60cm height, leveling concrete for Roof slab, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including demolition & removal of debris outside MD land of any description and in any position not otherwise specifically provided for complete all as specified and as directed. directed |
| 3 | M & L for water proofingtreatment over RCC slabwith the following specification all as specified & directed :-(i) Removing all loose gravel, dirt, oil, grease and foreign materials by jet or dry air, cleaning the surfaces mechanically or by grinding to make it smooth (ii) Screed bed/rendering 10mm thick in CM (1:3) mixed with and including water proofing compound as per manufacturers instructions, finished even & smooth(iii) Applying compatible primer / bonding bitumen @ 0.40 Litre/Sq m (iv) Laying APP modified water proofing membrane as per IS 1654-2017/IS 16352-2017 , 3mm thick and weighing not less than 3.80kg/Sq m reinforced with non woven polyster/HMHDPE matt black finished over and torch applications of membrane with 75mm side overlap and 100mm end lap complete as per manufacturer's instructions (v) Applying a coat of solar reflective bituminous aluminum paint on top @ 0.10 litre/sq m (Note : Water ponding test shall be carried out for 48 hours for water proofing) |
| 4 | Disconnecting existing water tanks of capacity exc 250 & not exc 500litres , setting aside including necessary connections (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position including Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc.complete all as specified and as directed. |
| 5 | Disconnecting existing tanks of capacity exc 500 & not exc 1000 litres, setting aside including necessary connections (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position including Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc. .complete all as specified and as directed. |
| 6 | Taking down cement plaster of any description including raking out joints, hacking for key and disposal of debris to out side MD land all as specified and as directed. |
| 7 | M&L for Rendering 15mm thick cement mortar (1:6) on brick or concrete wall surfaces, finished even and smooth without using extra cement all as specified and as directed. |
| 8 | M&L for Rendering 5 mm thick cement mortar (1:3) on concrete ceiling surfaces , finished even and smooth without using extra cement all as specified and as directed. |
| 9 | M&L for rendering 15 mm thick cement mortar (1:4 ) on other than fair faces of brick work or concrete surfaces mixed with WPC, finished even and smooth without using extra cement all as specified and as directed.(Note :- WPC will be measured and paid separately) |
| 10 | Supply only liquid water proofing compound, ISI marked, all as specified and as directed. |
| 11 | M & L for Preparation of new plastered ceiling surfaces including in narrow widths / bands etc and applying three coats of white wash complete all specified and as directed. |
| 12 | M & L for Preparation of newly plastered wall surfaces including in narrow widths/ bands etc and finishing with the following specification all as specified & directed :- (i) Applying 1 mm thick wall care putty finished even & smooth (ii) Applying one coat of alkali resistant primer (iii) Applying two coats of Acrylic emulsion distemper |
| 13 | M & L for Preparation of newly plastered surfaces of wall / chajjas including filling the minor racks etc with crack filling material all as per manufacturers instructions etc and applying two coats of Anti fungal weather proof grade exterior acrylic emulsion paint of approved tint over a coat of weather proof grade self primer complete all as specified and as directed. |
| 14 | M & L for rotational moulded polythylene water storage tanks 500 litres capacity (cylindrical vertical with closed top), triple layered, hoisting and fixed in position on roofs including ball float valve 20 mm dia PTMT (Minimum weight 2 0 m m - 2 1 0 g m s) and fittings including dismantling existing water storage tank, complete all as specified & directed |
| 15 | M & L for rotational moulded polythylene water storage tanks 1000 litres capacity (cylindrical vertical with closed top), triple layered, hoisting and fixed in position on roofs including ball float valve 25 mm dia PTMT (Minimum weight 25mm-455gms ) and fittings including dismantling existing water storage tank, complete all as specified & directed |
| 16 | S & F in repairs Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe 25mm dia bore complete all as specified & directed.(Minimum weight 25mm-455gms) all as specified and as directed. |
| 17 | Supply & laying CPVC pipes 20 mm outer dia SDR 11 Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including all fittings and specials including taking down 15 mm GI tubing and connections complete all as specified & directed. |
| 18 | Supply & laying CPVC pipes 25 mm outer dia SDR 11 Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including all fittings and specials including taking down 20 mm GI tubing and connections complete all as specified & directed |
| 19 | S&F in repairs CPVC gate valves with lever, screwed both ends for iron pipe 20mm dia bore and fixed complete all as specified & directed |
| 20 | S&F in repairs CPVC gate valves with lever, screwed both ends for iron pipe 25mm dia bore and fixed complete all as specified & directed |
| 21 | Taking down shutters of any description exc 1 Sqm but not exc 2 Sqm and Re-fixing in same opening complete all as specified and directed |
| 22 | Resecuring or easing & adjusting without taking down shutters of any description exc 1 sqm but n.exc 2 sqm each complete all as specified and directed |
| 23 | Taking down chowkat (without taking of shutter from the frame) area not exc 1.5 sqm each including making good the disturbed surface in PCC 1:2:4 type B0 or CM 1:3 all as specified and directed |
| 24 | All as per Item No. 23 herein before but area exc 1.50 sqm and not exc 4.00 sqm each |
| 25 | Taking down shutters of any description area exc 1 Sqm but not exc 2 Sqm each all as specified and as directed |
| 26 | M & L for Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification complete all as specified and directed |
| 27 | M & L for Factory Made Solid PVC Moulded Door Shutter, wood free EPS, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site all as specified & directed |
| 28 | S&F Second class hard wood plain, solid, straight chowkats and frames, wrought, frame rebated on the solid, rounded or chamfered, put tegether with glue pinned at joints etc complete all as specified and as directed |
| 29 | S&F Flush door shutters 35mm thick, factory made as per IS:2202 (Part-I 1999) solid core construction, with block board core and plywood face panels, commercial type on both sides with lipping / frame to match fixed to chowkhats all as speified and directed |
| 30 | M & L for second class hard wood 35 mm thick glazed and skeleton shutters, open rebated and prepared to receive glass, gauze,etc. without sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass,etc, size of members of shutters as spe in SSR Part-1, Section 8, clause 8.24 (a) kiln seasoned and chemically pressure treated complete all as specified and as directed (Note: Supply & fixing of 4 mm thick sheet glass and wire mesh be measured and paid separately.) |
| 31 | S & F Plain framed, panelled shutter (two panel) of 35mm thick with lock rail and panel of 9mm BWP commercial ply or 12mm venereed particle board with commercial veneering on both faces, rail and style are of second class hardwood & the size of rail and stile as per IS:1003 (Part-I), kiln seasoned and chemically pressure treateds fixed to chowkhat all as specified and as directed. |
| 32 | S&F for mild steel work as in hold fast, small articles made with flat iron conforming to Fe-290 Gde-E-165 all as specified & directed |
| 33 | M & L for Powder coated (minimum thickness of powder coating 50 micron) aluminium frame for doors, windows, ventilators with one or more rebates including jointing cleat for fixing etc. complete all as specified & directed |
| 34 | M & L for Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws complete all as specified & directed.( Note: sheet glass and wire mesh will be measured and paid separately ) |
| 35 | M & L for powder coated aluminium grill ( powder coated or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design / pattern, with approved standard section, not less than 2.5 kg/sqm and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all as specified and as directed |
| 36 | Supply only Sheet glass 4mm thick ordinary quality and glazing with oil putty or in wooden /steel /aluminium /rubber beading in square not exceeding 0.5 Sqm in each pane and all as specified and as directed |
| 37 | Supply only Sheet glass 4mm thick ordinary quality and glazing with oil or in wooden /steel /aluminium /rubber beadingputty in square exceeding 0.5 Sqm in each pane and all as specified and as directed |
| 38 | Supply only stainless steel wire cloth 0.36mm nominal dia and average width of aperture 1.40mm and fixed with tinned tack or galvanized wire staple all as directed. |
| 39 | M&L for Preparing new wooden surface of any description, not other wise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer etc complete all as specified and as directed |
| 40 | S & F Butt hinges stainless steel 100mm long and fixed to door frame and shutter duly welded/screwed complete all as specified and as directed |
| 41 | S & F Butt hinges medium weight, cold rolled mild steel 100mm long and fixed to door frame and shutter duly welded / screwed complete all as specified and as directed |
| 42 | S&F Aluminium anodised tower bolt 150mm long of extruded section etc complete all as specified and as directed |
| 43 | S&F Aluminium anodised tower bolt 200 mm long of extruded section etc complete all as specified and as directed |
| 44 | S&F Aluminium handle 125 mm size, cast type, anodised etc complete all as specified and as directed |
| 45 | S&F Aluminium handle 150 mm size, cast type, anodised etc complete all as specified and as directed |
| 46 | S&F Aluminium alloy, anodised sliding door bolt 300 mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy etc complete all as specified and as directed |
| 47 | S & F Floor door stopper of aluminium alloy powder coated, with hard down steel spring, length of plate 140 mm all as specified and as directed. |
| 48 | S&F mild steel 300mm ordinary rat tail rod pattern springs,including roller and roller plate complete |
| 49 | M & L for figured glass 4 mm thick, pin head type and glazing with oil putty/wooden or steel beading in squares not exc 0.5 sqm in each pane, including hacking out old broken glass of any thickness, size, quality or description from metal frame including punching or drilling out old glazing pins/spring clips etc complete all as specified and as directed. |
| 50 | M&L for Sheet glass 3mm thick ordinary quality and glazing with oil putty / wooden or steel beading in squares not exc 0.5 sqm in each pane including hacking out old broken glass of any thickness, size, quality or description from metal frame including punching or drilling out old glazing pins/spring clips etc complete all as specified and as directed. |
| 51 | S & F in repairs stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.18 mm fixed with MS screw or nut bolts with or without wooden or steel beading in repairs all as specified and as directed. |
| 52 | S&F in repairs door closer hydraulically regulated designation No.3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 Kg of aluminium (extruded section)body in repairs complete all as specified and as directed. |
| 53 | M & L for PVC sheet fillet 5mm thick & width 35mm for wall panelling including fixing on to wall to make PVC Frame as per specification and drawing complete all as specified |
| 54 | M & L for Prelam PVC sheet 5mm thick in strips & channel feathered at the edges for fixing on Solid PVC Wall Lining, Insulated PVC Wall Lining, and Solid PVC Partitions inclusive of Solvent Cement and fixing at site including dismantling of old wall boarding including cover fillet complete all as specified |
| 55 | S&F Non asbestos fibre cement building boards 4 mm thick including anodised aluminium snap grid frame work of size 605 x 605mm including hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long for false ceiling fixed or laid/ inserted to timber/GI/Aluminium framework with screws in ceiling flat or slopping complete all as specified and directed. |
| 56 | M & L for Granite slab 20 mm thick (of any type) work (table rubbed and polished) in steps,riser,tread, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, including cutting and polishing laid on screed bed 15 mm thick in CM (1:4) set and jointed including dismantling of old stone slabs laid bedded and pointed in any mortar complete all as specified & directed. |
| 57 | M & L for Edge moulding to 18-20mm thick granite stone any description of counters vanities etc. including machine polishing to edge to give high gloss finish etc. complete all as specified & directed. |
| 58 | S & F in repairs Prelaminated particle board 18/19mm thick, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work, alround 6mm th teak fillets fixed in kitchen Cabinet or cupboards all as specified & directed. |
| 59 | M&L for Plain fillets square, rectangular or triangular in section clean sawn , secured with nails or brads of second class hard wood exc 6 & n exc 13 sqcm cross section area fixed to cupboard shutter including taking down old fillets all as specified and directed. |
| 60 | S&F Continuous piano hinges, 30mm width of flaps (when open) , mild steel, bright finish or electro galvanised all as specified and directed. |
| 61 | S&F Hasp and staple 100 mm size, safety type, aluminium anodized with mild steel hinge pin including bolt to hinge plate and fixed with screws /fixed in repairs. |
| 62 | S&F Magntet door catcher made of stainless steel complete all as specified and directed |
| 63 | S & F Cupboard knobs 40 mm dia fixed with nut, screw and washer of Brass, polished complete all as specified and as directed. |
| 64 | M & L for toughned frosted 10 mm thick glass (as design approved by GE ) as in hinged doors, including stainless steel handle 300 mm long, door buffer, SS U clip, locking arrangement as in automatic doors / partition and similar works including cutting to shape , drilling holes required complete all as specified and as directed. |
| 65 | Dismantling of floor, hearth or wall tilling including cement mortar bedding (but not backing) and removing rubbish off from premises all as specified and as directed. |
| 66 | M&L for Non Skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including Screed bed or bedding layer 15 mm thick CM (1:4) all as specified and as directed. |
| 67 | M&L Non Skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed or bedding layer 15 mm thick CM (1:4) all as specified and as directed. |
| 68 | M & L for Glazed ceramic coloured tiles 350 x 250x 7 mm/ 450 x 350 x 7 mm/ 300x450x7 mm thick in vertical surfaces, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over & including backing coat 10mm thick CM (1:4) on brick work or concrete surfaces all as specified and as directed. |
| 69 | M&L for Vitrified coloured tiles 10mm thick (square / rectangular), light shade, polished, tiles of size 600mm x 600mm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 10 mm screed bed in CM 1:4, complete all as specified and as directed |
| 70 | S & F in repair kitchen sink with drainage board made of stainless steel 1mm thick kitchen or laborotry with plugs, washers and wastes including bedding in mortar on to dwarf wall or including fixing cantilever brackets and connecting union pipes, overall size 915x460mm, bowl size 410x330x160mm complete all as specified and directed. |
| 71 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 72 | M&L for Pre-cast cement concrete (1:3:6) type C-1 using 20mm graded stone aggregate as in solid block masonry, exc. 10 cm in width and setting in cement mortar (1:6) complete all as specified and as directed |
| 73 | S & F PVC (SWR) pipes 75 mm dia bore single socketed in any length with rubber ring joints fixed to walls including necessary fittings all as specified and as directed. |
| 74 | All as per item No 73 herein before but 110 mm dia bore . |
| 75 | S&F in repair PVC (SWR) Bends 75mm dia bore with access door of any radius all as specified and as directed. |
| 76 | All as per item No 75 herein before but 110mm dia |
| 77 | M & L for Preparation of old treated ceiling surfaces including in narrow widths/ bands etc and applying one coat of white wash complete all specified and as directed. |
| 78 | M & L for Preparation of old treated ceiling surfaces including in narrow widths/ bands etc and applying one coat of Acrylic emulsion distemper complete all specified and as directed. |
| 79 | M & L for Preparation of old painted / treated steel and iron surfaces over 10cm width or girth and applying one coat of synthetic enamel paint all as specified and as directed. |
| 80 | M & L for Preparation of old painted / treated wood and wood based surfaces over 10cm width or girth and applying one coat of synthetic enamel paint all as specified and as directed. |
| 81 | M & L for Preparation of old decorated / treated wall surfaces including washing, rubbing down and stopping including necessary putty filling in cracks etc and applying two coats of acrylic emulsion distemper all as specified and directed. |
| 82 | M & L for Complete removal of existing treatment on walls of any description including in narrow widths/ bands etc and finishing as per following specification complete all specified and as directed :-(i) Applying one coat of 1 mm thick wall care putty finished to smooth surface (ii) Applying one coat of alkali resistant primer(iii) Applying two coats of acrylic emulsion distemper |
| 83 | M & L for Complete removal of existing treatment on wall surfaces chajjas etc of any description including brooming down with steel wire brushing, scrapping down smoke soot's , moulds, moss and efflorescence, salts, trading oil and greasy spots, including filling the minor racks etc with crack filling material all as per manufacturers instructions etc complete and applying two coats of Anti fungal weather proof grade exterior acrylic emulsion paint of approved tint over a coat of weather proof grade self primer complete all as specified and as directed. |
| 84 | Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar complete all as specified and as directed. |
| 85 | Surface excavation not exceeding 30cm deep and averaging 15 cm deep and getting out in hard/dense soil all as specified and as directed. |
| 86 | Surface excavation not exceeding 30cm deep and averaging 21 cm deep and getting out in hard/dense soil all as specified and as directed. |
| 87 | M&L for Hardcore of guage 63mm, broken stone or boulders, deposited, spread and levelled in layers n.exc 15cm thick, watered and rammed to a true surface all as specified and as directed. |
| 88 | M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in 75mm thcik sub base of pavement complete all as specified and as directed . |
| 89 | M&L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in 75mm thcik sub base of floor complete all as specified and as directed . |
| 90 | M&L for chequered cement concrete tiles 300 x 300mm x 25mm thick, set, jointed and pointed in neat cement slurry with grey pigment cement and pigment over & including screed bedding layer 20mm thick cement mortar (1:6), in flooring complete all as specified and as directed . |
| 91 | M&L for PCC (1:2:4) type B-0 using 12.5mm graded stone aggregate as in 40mm thick floor finished even and smooth without using extra cement all as specified and as directed . |
| 92 | M & L for Forming 40mm deep x 10mm wide construction joints filled with sealing compound Grade `A' all as specified and as directed. |
| 93 | M & L for Plain cement concrete (1:2:4) type B-0 using 12.5mm graded stone aggregate as in kerbs or mud stops, rounded or chamfered on edges all as specified and as directed |
| 94 | M & L for Point Wiring with single core PVC insulated unsheathed 1.5 Sqmm cable 1100 volts grade multi stranded FRLS copper conductor conforming to IS 694 drawn through and including non-metalic rigid PVC conduit medium grade ISI marked with accessories including GI / MS branded sunken boxes of suitable module concealed on walls including modular frame and cover of suitable module fixed with cadmium plated iron screws for housing modular type switches, switch socket outlets, fan regulators etc., including 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed for the following :- |
| 95 | One light point controlled by one switch |
| 96 | One fan / exhaust point controlled by one switch / regulator |
| 97 | One 3 pin socket out let 5 Amps on independent board |
| 98 | One 3 pin socket out let 5 Amps on same board |
| 99 | M & L for Point Wiring with single core PVC insulated unsheathed 2.5 Sqmm cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and including non-metalic rigid PVC conduit medium grade ISI marked with accessories concealed wiring including GI / MS branded sunken boxes of suitable module concealed on walls including modular frame and cover of suitable module fixed with cadmium plated iron screws for housing modular type switches, switch socket outlets, fan regulators etc., including 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed. |
| 100 | Note for Item No 94 & 95 :-(i) The earth wire for the points in the same circuit can be looped from point to point(ii) Earth wire shall be taken inside the conduit(iii) Cost of terminal box is deemed to be included in the item rate quoted for point wiring(iv) Cost of a circuit of any length of cable from DB to any switch/ socket board to be included in point wiring. |
| 101 | S&F LED batten with luminaire suitable for indoor applications 20 Watts capacity, 4 feet long with extruded aluminium housing & integrated LED channel rectangular white arcylic cover complete with all accessories all as specified and directed. |
| 102 | S&F in repairs Recess mounted LED Luminaire of size 600mm x 600mm, 36 Watts capacity white powder coated CRCA housing with LEDs seamless front frame with flat white high transmission arcylic cover complete with all accessories all as specified and directed. |
| 103 | Supply and Fix Modular switch 1 way 6Amps,1 module 230volts all as specified and directed. |
| 104 | Supply and fix Modular switch 1 way 16Amps, 1 module 230volts all as specified and directed. |
| 105 | Supply and fix modular Socket, 6Amps - 2/3 pin combined 2 module 230volts all as specified and directed. |
| 106 | Supply and fix modular Socket 6Amps /16Amps - 2/3 pin combined 2 module, 230volts all as specified and directed. |
| 107 | Supply and fix modular type Fan step regulator, 120W - 2 module 230volts all as specified and directed. |
| 108 | S&F Ceiling rose, surface bakelite type 65 x 50 mm, 2 to 3 terminals all as specified and as directed |
| 109 | S&F MCB Distribution board, SPN 8 way, double door type 240 volts with 200 Amps rated bus bar as specified and as directed. |
| 110 | S&F MCB SPN 240 volts 32 Amps 10KA, C curves complete all as specified and as directed |
| 111 | S&F MCB single pole 240 volts, 10 to 20 Amps, 10KA, C curves complete all as specified and as directed |
| 112 | M&L for Sub main wiring 1100 volts grade multistranded FRLS copper conductors, two runs of single core 6 Sqmm along with 6 Sqm PVC insulated single core multistranded copper conductor cable as earth continuity conductor run through & including suitable size PVC conduit with accessories all as specified and as directed.(Note : Three run of 6sqmm cable and one run of conduit altogether measured as one unit) |
| 113 | M&L for Earthing with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I and as specified or indicated and testing on completion including earth work and excavation in any type of soil, PCC (1:3:6) type C1 chamber, pre cast slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia TMT bars reinforced at 10 cm centre to centre both ways, funnel with watering pipe wire mesh and lugs, test point complete all as specified and as directed. |
| 114 | S&F Ceiling fans with complete accessories, 230Volts, SP 1200 mm Sweep with BEE 5 Star rating complete with all accessories and fixing the fan from ceiling rose with 3 core flexible copper wire 24/0.20 sqmm, etc all as specified and as directed. |
| 115 | S&F Exhaust fan 300 mm sweep with louvers fixed outside, AC single phase 230/ 240 Volts with all accessories and fixing the exhaust fan from ceiling rose with 3 core flexible copper wire 24/0.20 sqmm, etc all as specified & directed. |
| 116 | Excavation in trenches in hard/dense soil not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying of cables / erection of pole etc complete all as specified and as directed. |
| 117 | Returning, filling in trenches including spreading leveling watering and well ramming in layers with soil not exc 25 cm thick in each layer complete as specified and as directed |
| 118 | Removing excavated soil to a distance not exc 50m and depositing n. exc 1.5 mtr above the starting point complete all as specified and as directed |
| 119 | M&L for sand cushioning under and above the cable all as per Para 19.75 SSR part-I complete all as specified and as directed.(Note : Punned thickness will be measured for payment) |
| 120 | Supply & Laying sub class burnt 'B' bricks for cable protection complete as specified as directed |
| 121 | S&L XLPE insulated, screened, PVC bedded, galvanised steen strip or wire armouned power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 35 Sqmm, 3.5 core laid in trenches / wall all as specified and as directed |
| 122 | S&F GI tubing light grade 50 mm bore with all fitting laid in trenches/walls/Roads for cable protection all as specified and as directed . |
| 123 | M&L for Earthing with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized strip 25x4 mm as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I and as specified or indicated and testing on completion including earth work and excavation in any type of soil, PCC (1:3:6) type C1 chamber, pre cast slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia TMT bars reinforced at 10 cm centre to centre both ways, funnel with watering pipe wire mesh and lugs, test point complete all as specified and as directed. |
| 124 | Supply, installtion, testing commisioning in replacment of weather and wermin proof LT panel board of size not less than 120cm x 45 cm x130 cm, CPRI approved factory made out door type, platform mounted, totally enclosed, dust and vermin proof, openable from both front and rear side, made out of 3.15 mm thick CRCA sheet complete including inner chambers/partitions to mount the following electrical accessories and built upon 50x50x6mm angle iron frame work, having front & rear hinged doors, lifting lugs 2 Nos, provision for earth strip connection, bottom detachable gland plates, connecting using suitable size of zinc plated and passivated nut, bolts and washers. The cabinet & all members should be chemically treated with anti-corrosive chemicals and spray paint with two coats of synethetic enamel paint over a coat of red oxide primer and busbar for phase & neutral 200 Amps 35 KA capacity and IP 54 protection mountend on epoxy insulator 01 set including mounting the panel board on ground with PCC (1:2:4) type B-2 bedding ( Contd/-.....) |
| 125 | upto a height of 50 cm above ground leval. The internal connection of MCCB should be provided with Aluminium strip of suitable size and necessary grouting / foundation as required at site with & including following items etc complete all as specified & directed:-(a) On load change over of 100 Amps- 01 No (b) INCOMER - MCCB, 4 pole 63 Amps with breaking capacity of 25 KA . - 01 No.(c) Outgoing- (i) MCCB, 4 pole 41 amps with breaking capacity of 25 KA . - 03 No. (ii) MCCB, 4 pole of capacity 32 amps with breaking capacity of 25 KA . - 02 No.(d) Digital Voltmeter 0-500 V with selector Switch - 01 No(e) Timer switch forswitching ON/ OFF Street light daily astronomical calculation of sunrise/sunset timesbased on intered loc or loc coordinates. Nos-01(f) Phase Indicator Lamp RYB with sheds LED Type - 01 Set of three Please Enable Macros to View BoQ information |