| 1 | Taking down and dismantling of defective parts of geysers of any capacity by unscrewing the nuts from the mounting bolts and disconnection of electric and water connection including transportation the same to workshop and reinstallation/Reassembling complete of geysers after repair.NOTE(i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new/ repaired items are deemed to be included under this item.(ii) Minor parts such as nuts and bolts reqd for fixing inner tank is deemed to be included under this item. |
| 2 | S&F in replacement of inner stainless steel container thick dully shaped and welded for 50 Ltrs Geysers complete all as specified and directed. |
| 3 | S&F in replacement of inner stainless steel container thick dully shaped and welded for 25 Ltrs Geysers complete all as specified and directed. |
| 4 | Supply pressure release valve for geysers |
| 5 | Supply heating element 1.5 KW triangle type for Geysers. |
| 6 | Supply heating element 1.5 KW round type for Geysers. |
| 7 | Supply heating element 2.0 KW triangle type for Geysers. |
| 8 | Supply heating element 2.0 KW round type for Geysers. |
| 9 | Supply thermostat of geysers |
| 10 | Supply geyser assy 6/9 holes including, rubber rings, clamps, nuts & bolts etc for 25 Ltrs capacity geysers. |
| 11 | Supply geyser assy 6/9 holes including, rubber rings, clamps, nuts & bolts etc for 50 Ltrs capacity geysers. |
| 12 | Supply base plate of geysers of 25 Ltrs capacity. |
| 13 | Supply base plate of geysers of 50 Ltrs capacity. |
| 14 | Supply and fix in replacement PVC connection ½” heavy duty 450mm long for cold water. |
| 15 | Supply and fix in replacement PVC connection ½” heavy duty 450mm long for Hot water. |
| 16 | Supply and fix in situ PVC cable 40/.0076 three core for geysers |
| 17 | Supply & fix anchor Fastner for fixing of Geysers and exhaust fan. |
| 18 | Supply and fix in situ indication lamp for Geysers |
| 19 | Supply and fix in situ plug top 3 pin 15 Amp for Geysers |
| 20 | Supply & fix single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole mcb 10 amps. |
| 21 | Taking down ceiling fan from any position dismantling the blades, cutting damaged winding and taking the fans to contractor wksp for rewinding of ceiling fan motor single phase 220/230 volts 50 c/s 1200/1400 mm sweep of any type with suitable size super enameled copper winding wire with allied winding material varnishing with air dry insulation carrying complete servicing of fan by cleaning greasing the bearing, oiling of moving parts, washer packing including replacement of split pin, twin flexible copper wire of size 0.5 Sqmm length upto 1 Mtr length, reassembling and testing on load and fixing in existing position,complete all as directed. unserviceable parts/components require for replacement shall be paid under separate item as “supplied only” . Note (i) The rates for above items are deemed to include for transportation to & from of Fan/Eaxhaust fan to workshop as approved by Engineer-in-charge for necessary repairs and testing of fan at workshop . |
| 22 | All as per Sl item No.21 herein before but for exhaust fans 300mm sweep. |
| 23 | All as per Sl item No.21 here in before but for exhaust fan 450mm sweep |
| 24 | Supply only ball bearing of suitable size for 1200/1400mm sweep ceiling fan. |
| 25 | Supply & fix Fan blade (Metalic Body) of suitable size for 250/300/450 mm sweep Exhaust fan. |
| 26 | Supply only ball bearing suitable for exhaust fan of 300/450 mm sweep. |
| 27 | Supply only condenser 2.5/3.15 MFD. |
| 28 | Supply only condenser 4 MFD |
| 29 | Spray painting to all exposed surfaces of ceiling fan 1200/1400 mm sweep after cleaning all dust and scratching of old paint and painting with one coat of synthetic enameled paint and writing Numbering in capital letter complete, all as directed by Engr-in-Charge. |
| 30 | All as per ser item No 29 herein before but exhaust fan of 300/450 mm sweep |
| 31 | Supply & Fix Rubber real with nut, bolts clamp and washers of suitable size for ceiling fan. |
| 32 | Supply and fix in situ Top and bottom canopy of ceiling fan 1200/1400 mm sweep as approved by Engr-in-Charge |
| 33 | Supply and fixing stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc as required |
| 34 | Supply and fix Ceiling fan blade suitable 1200/1400 mm sweep and to match with the existing fan and as approved by Engr-in-Charge |
| 35 | Supply& fix Down rod of mild steel of standard dia upto 0.5 mtrs length suitable for ceiling fan 1200/1400 mm sweep |
| 36 | Supply & fix Fan hook 15\\" long made out of 8mm MS bar 'S' hook including suitable clamp made out of 25 x 3mm MS flat iron and also including nuts, bolts etc. complete all directed. |
| 37 | Supply and Fix in replacement of Building Security Light fitting LED 35 W 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver,lamp bracket with impact and corrosion resistant including thermal managment in multiple optics complete with IP 65/66 protections complete all assessories/ electric connectins all as specified. |
| 38 | Supply and Fix in replacement of Building Security Light fitting LED 60 W 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver,lamp bracket with impact and corrosion resistant including thermal managment in multiple optics complete with IP 65/66 protections complete all assessories/ electric connectins all as specified. |
| 39 | Supply and fix in replacement of MCB SP- 6 to 32 Amp, 240 volts 'C' series, complete all as specified. |
| 40 | Supply and fix in replacement of MCB SP-32 to 40 Amp, 240 volts 'C' series, 50Hz AC supply, complete all specified. |
| 41 | Supply and fix in replacement of MCB SPN-6 to 32 Amp, 240 volts 'C' series, 50Hz AC supply, complete all specified. |
| 42 | Supply and fix in replacement of MCB SPN-40 to 63 Amp, 240 volts 'C' series, 50Hz AC supply, complete all specified. |
| 43 | Supply and fix in replacement MCB TPN 40 to 63 Amp 240 volts 'C' series complete all specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information |