| 1 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting outin soft/loose soil, complete all as specified and directed. |
| 2 | Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed. |
| 3 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and directed. |
| 4 | M&L Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified and directed. |
| 5 | M&l For Sand filling under floors or in foundations including watering and consolidation, complete all as specified and directed. |
| 6 | M&L Cement concrete in foundations, filling and mass concreteType D2 1:4:8 (40 mm graded Stone aggregate), complete all as specified and directed |
| 7 | M&L for RCC design mix M25 using 20 mm graded aggrgate for Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass co, complete all as specified and directed. |
| 8 | M&L RCC design mix M25 using 20 mm graded aggregate for Columns, pillars, piers, posts and struts complete all as specified and directed. |
| 9 | M&L RCC design mix M25 using 20 mm graded aggregate for Beams, cantilevers, bressummers, lintels over 1.5m span complete ,complete all as specified and directed |
| 10 | M&L RCC design mix M25 using 20 mm graded aggregate for Slabs supported on walls,beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 11 | M&L Form work for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, flat, rought finished surfaces of concerete complete all as specified and directed. |
| 12 | M&L Formwork to sides of pillars,posts, struts, piers, columns and stanchions. Square,rectangular or polygonal, roughed finished surfaces, complete all as specified and as directed. |
| 13 | M&L Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc flat, rought finished surfaces of concerete complete all as specified and directed. |
| 14 | M&L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) flat, rought finished surfaces of concerete complete all as specified and directed. |
| 15 | Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed. |
| 16 | M&L TMT bar 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 17 | All as per item no 16 but 5 mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and as directed. |
| 18 | M&L brick work with sub class 'B' bricks, old size bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar (1:6) complete all as specified and directed. |
| 19 | M&L Brickwork with burnt old size bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and as directed. |
| 20 | M&L rendering 15mm thick on other than fair faces of brick or concrete Surfaces in cement mortar 1:6 finished even and smooth, without using extra cement, complete all as specified and directed. |
| 21 | M&L rendering 20mm thick with cement mortar 1:4 on fair faces of brick work in two layers (10mm and 10mm) sperately mixed with and including water proofing compund in top layer as per manufacturers instruction and finishing the surfaces even and fair complete all as specified and directed. |
| 22 | M&L preperation of new plastered surfaces and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed. |
| 23 | M&L preperation of new plastered surfaces of walls and applying three coats of white wash,complete all as specified and as directed. |
| 24 | M&L preperation of new plastered surfaces in ceilings and applying three coats of white wash,complete all as specified and as directed. |
| 25 | M&L 100mm thick cement concrete type D-2 (1:4:8) using 40 mm graded stone aggregate as sub base of floor finished even and fair complete all as specified and directed. |
| 26 | S&F Glazed ceramic coloured tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in adhesive compound as per manufacturers instruction and pointed in white or colour cement to match the surface complete all as specified and directed. |
| 27 | M&L Non - skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in adhesive compound as per manufacturer instructions and pointed in white or coloured including 15 mm thick Screed bed or bedding layer of cement mortar 1:6, for laying floor finishes, complete all as specified and directed. |
| 28 | M&L Rendering 10mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces complete all as specified and directed. |
| 29 | M&LRendering 5mm thick in ceiling surface cement mortar 1:3 on fair faces of brick work or concrete surfaces and finishing the surface even and smooth without using extra cement complete all as specified and directed. |
| 30 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, fixed in opening as specified in SSR Part I, Section 8 complete all as specified and as directed. |
| 31 | S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes far top and bottom rails, MS frame shall be covered with heat moulded plain colour PVC “C” channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail; Paneling of plain colour PVC sheets to be fitted in the MS frame welded / sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement complete all as specified in SSR Part I, Section 8 complete all as specified and as directed. |
| 32 | S&F Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified |
| 33 | S&F Powder coated Anodised aluminium (minimum thickness of powder coating 50 micron) window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.), hinges type B-21 100mm long (2 no.) suitable handle (1no.) complete all as specifiedNote:-(i)Glass/wire guage/Particle board as required shall be measured and paid seperately under appropiate item(ii) Design/pattern, profile sizes and other dimensions shall be of standard sizes and as directed |
| 34 | S&F 4mm thick plain frosted glass, ordinary quality and glazing with oil putty in square n. exc 0.5 sqm in each pane complete all as specified and as directed. |
| 35 | S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 36 | S&F 100mm Butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified and directed . |
| 37 | S & F 150 mm long Extruded Aluminium alloy handles, fabricated type, anodised,complete all as specified and directed. |
| 38 | S & F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section,complete all as specified and directed. |
| 39 | S&F 600x450mm bevelled edge mirror of selcted quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers all as specified complete all as specified and as directed |
| 40 | S&F Grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as specified and as directed. |
| 41 | S&F PVC connection 15mm size with PTMT nuts, 600mm long complete all as specified and directed. |
| 42 | S&F 110 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 43 | S&F 75 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete complete all as specified and directed. |
| 44 | S&F 110 mm bore PVC (SWR) bends of any radius,complete all as specified and directed. |
| 45 | S&F PVC (SWR) 110mm bore (dia) PVC (SWR) branch piece, single (double Y) equal or unequal Jointing with Solvent Cement complete all as specified and directed. |
| 46 | S&F 110mm bore PVC (SWR) junction single, (Single T) equal or unequal with access door complete all as specified and directed. |
| 47 | S&F 110mm bore PVC (SWR) Vent Cowl complete all as specified and directed. |
| 48 | S&F 110 mm bore dia PVC (SWR) 'P’ trap complete all as specipied and directed |
| 49 | S&F 75mm dia of outlet, PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed. |
| 50 | M&L High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in trenches 50 mm bore of pipe complete complete all as specified and as directed. |
| 51 | S&F 15mm bore Bib taps, chromimum plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed. |
| 52 | S&F 15mm bore pillar taps, cast copper alloy with capston heads, chromium plated, fancy type, screwed down high pressure, with or without lettered hot or cold with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and as directed |
| 53 | S&F 15mm bore chromium plated angular Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete as specified and as directed. |
| 54 | S&F 15mm bore angular Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete as specified and as directed. |
| 55 | S&F 15mm bore stop valves fancy type cast copper alloy, chromium plated with long shank and cup (concealed type), screwed both ends including necessary fittings such as sockets for pipe or for union all complete as specified and as directed. |
| 56 | Cutting into existing manholes of 150 mm dia for connecting new drains making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 round section) in cement concrete 1:2:4 type B1, smooth finished and reforming benching as required, complete all as specified and directed. |
| 57 | S&F vitreous China wash basin, white, flat back, size 550x400mm including brackets cutting for and pinning in ends of brackets or erecting stand, and 32 mm bore Waste coupling of PTMT (half or full hreaded) .(Minimum weight 32mm-45gms) complete all as specified and as directed. |
| 58 | S&F 125mm Brass chromium plated shower rose with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed. |
| 59 | S&F Vitreous China wash down water closet pan, pedestal pattern white (excluding fixing bolts, flushing cistern and flush pipe) including Plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed. |
| 60 | S&F, Vitreous China squatting pan \\"Orissa\\" pattern size 580 x 440mm white with integral foot rest , including S or P traps (Excluding flushing cistern & flush pipe), complete all as specified and directed. |
| 61 | S&F 10 ltrs capacity low level valve less PVC syphonic action type flushing cistern white with inlet ball valve float and handle, PVC flush pipe, complete all as specified and as directed. |
| 62 | Supplying and laying of 20mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings laid in floors fixed to walls and ceilings or laid in floors complete all as specified and as directed. |
| 63 | Supplying and laying of 25mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings laid in floors fixed to walls and ceilings or laid in floors complete all as specified and as directed. |
| 64 | S&F 1000 Ltrs. Capacity rotational moulded polyethylene water storage tanks four layer in white colour (cylinder vertical with class top) hoisted and fixed in position all as specified including 20mm bore ball brass valves, high pressure, with polythene float and flynut complete screwed for iron pipe or brass ferrule and fixed,complete all as specified and as directed. |
| 65 | M&L for water proofing treatment to RCC roof slab, including parapet comprising with the following course of treatment/specification from bottom to top, complete all as specified and directed:-(i) Applying one coat of bituminous primer @ 0.40 Ltr/Sqm.(ii) Supply and laying 3mm thick APP based olymeric membrane of approved manufacturer with weight not less than 3.50 Kgs per Sqm, reinforced with non-woven polyester febric weight not less than 160gms per Sqm. Polymeric membrane shall be taken to a height of 30cm (minimum) and than inserted inside the groove of parapet wall and shall be finished by a membrane flashing.(iii) One coat of Solar reflective bituminious Aluminium paint of approved brand to be provided over the APP membrane as per manufacturers instructions. Note : (a) Work shall be carried out through specialized applicator approved by GE. Contractor shall submit sufficent documents/Credentials in support of Applicator whom he wants the work excuted.(b) Laying APP based polymeric membrane shall be done torch on method as per manufactures instructions. (c) A minimum overlap of 100mm and 75mm should be made at the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as per manufacturers instruction |
| 66 | M&L 75mm thick cement concrete (1:3:6) type C-2( using 40mm graded crushed stone aggregate) as in plinth protection laid in alternate bays (not exceeding 2 Sqm each) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and as directed. |
| 67 | S&F 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. |
| 68 | M&L Concrete bed to drain pipes of 150mm bore pipe including packing under, and haunching against the sides of pipes after they are laid and tested; in 1:3:6 type C2 (40mm graded aggregate) complete all as specified and directed. |
| 69 | Supplying, laying and testing of 150 mm internal dia of double wall corrugaed (DWC) high density polythylene pipe (HDPE) and stiffness classes 8 (SN-8) with ISI marked (With CML No ) with and including all fittings & jointing materials for connection of sewage line complete all as specified and directed. |
| 70 | M&L precast cement concrete 1:2:4 (using 20mm graded stone aggregate) type B1 as in landings, cover slabs(for man holes etc) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces and set in cement mortar 1:4 complete all as specified and as directed. |
| 71 | M&L concealed point wiring for One light point/Ceiling fan/Exhaut fan/bell point controlled by one way switch 5/6 amps complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated suken terminal box made out of MS sheet steel not less than 1.22 mm thick for boxes duly painted with aluminum inside and anticorrosive paint outside,(clear depth of the box not less than 60mm and this shall be increased suitably to accomadiate flush type regulators) concealed in walls, with 3mm thick bakelite/plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed complete all as specified and as directed.Notes:-(i) Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles. (ii) Where concealing of conduit is not feasible i.e. on surface of RCC roof slab, beam etc, conduit shall be fixed on surface with necessary saddles at no extra cost. |
| 72 | S&F Modular Switch 1 way 6 Amps, 1 module, complete all as specified and directed. |
| 73 | S&F Modular Switch Socket 6 A/ 16 Amps, 6 pin combined 2 module, complete all as specified and directed |
| 74 | S&F ceiling rose, 3 phase PVC/ polycarbonate, insulated body, three terminals, complete all as specified and as directed |
| 75 | S&F LED luminarie tube light fitting basic all purpose surface/wall mounted decrotative slim with polycarbonate housing & integrated electronic driver, 4 feet LED with high efficient LEDs 20 watt, (or nearest next higher wattage) with all accessories, suitable for operation on AC, single phase 220/230 Volts, 50 Hz, 6500K complete all as specified and as directed. |
| 76 | S&F LED luminarie tube light fitting basic all purpose surface/wall mounted 2 feet LED batton with polycarbonate housing & integrated electronic driver, with high efficient LEDs 10 watt, (or next nearer higher watt) with all accessories, suitable for operation on Ac, single phase 220 / 230 Volts, 50 Hz supply, complete all as specified and as directed. |
| 77 | S&F in repair, energy saving & environment friendly long life 35/36 Watt,(or nearest next higher wattage) CT ≥ 6500 K, LED building security light made up of pressure die-cast aluminium housing with acrylic cover as diffuser with IP 66 protection & impact resistance not less than IK-07 complete with integrated type, with high efficiency electronic driver, surge suppressor of 5 KV or more & high brightness LEDs, luminaire efficacy > 110 lumens/Watt, power factor ≥ 0.90, operating range 140 to 270 V, 50 Hz complete including GI pipe bracket of adequate size as required (Light Grade) of length 1.2 mtrs bent to shape and fixed with 40mm x 5mm MS flat with necessary nuts, bolts, washers etc, painting with two coats of syntheic enamel paint over a coat of primer and connecting up with and including three core twisted flexible copper conductor cable of suitable size all as specified & as directed. |
| 78 | S&F exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers and connecting up with and including three core twisted flexible copper conductor cable of suitable size all as specified & as directed. |
| 79 | S&F Sheet metal enclosure for 4 way Distribution Boards (DB’s), IP-43 double door with magnetic locking system, Single pole & neutral with 200 Amps rated bus bar,240 Volts, IP-43 protection, complete including. blanking plates as required & flush to wall/other surface complete all as specified and as directed |
| 80 | S&F MCB, DP, C Series 240 Volts, 32 Amps 50 HZ, 10KA complete all as specified and as directed. |
| 81 | S&F MCB, SP, C Series 240 Volts, 6-32 Amps 50 HZ, 10KA complete all as specified and as directed. |
| 82 | M&L Concealed sub-main wiring alongwith earth wire of size of 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of suitable size with all fittings and accessories (ISI marked) of suitable size with all fittings and accessories ISI marked including cutting chases in wall, floor etc and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE : (i)Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (ii) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED |
| 83 | Supply, lay, & testing cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core. |
| 84 | Supply & Laying well burnt brick , locally available best quality (sub class \\"B\\" bricks ) laid in trences perpendicular to UG Cable protection complete all as specified. |
| 85 | Supply & lay GI tubing light grade in protection of cable at road crossing /hard standing/pole protection fixed with clamps as per site requirement etc of size 40 mm dia bore complete all as specified and directed . |
| 86 | M&L sand cushioning in cable trenches over & under the cable, with river washed coarse sand, as per standard practice with proper compaction complete all as specified and directed. |
| 87 | Boring of holes horizontally under road without damaging the surface of road (minimum 1.0 metre below the road surface incl GI tubing not exc. 80mm bore for passing of UG cable, complete all as specified and directed. NOTE: GI pipe will be measured and paid seperately. |
| 88 | Supply and laying 3 layer ( inner antimicrobial, outer UV stabilized) ISI marked,IS-15801, PP-R pipes SDR 7.4 (PN-16) and PP-R plain fittings in trenches/walls/cellings or laying in floors complete of size outer dia 32mm ,including fittings, ISI marked, complete all as specified & directed. |
| 89 | Supply and laying 3 layer ( inner antimicrobial, outer UV stabilized) ISI marked,IS-15801, PP-R pipes SDR 7.4 (PN-16) and PP-R plain fittings in trenches/walls/cellings or laying in floors complete of size outer dia 40mm ,including fittings , ISI marked, complete all as specified & directed. |
| 90 | Cutting and screwing of existing steel tubing Pipe of any dia for taking branch connection or addition or alteration complete all as specified & directed. |
| 91 | Supply and fix PPR Gate Valves (Brass Insert) of 32 mm bore complete all as specified and directed. |
| 92 | Supply and fix PPR Gate Valves (Brass Insert) of 40 mm bore complete all as specified and directed. Please Enable Macros to View BoQ information |