| 1 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc completed all as specified. |
| 2 | M & L for rendering 15 mm thick on other than fair faces of brick wall finished fair & even in CM 1:6 complete all as specified and directed. |
| 3 | M & L for rendering 15 mm thick on fair faces of brick wall with mixing WPC @ 3% by wt of cement finished fair & even in CM 1:4 complete all as specified and directed. |
| 4 | M & L for rendering 10 mm thick on brick or concrete surface of ceiling finished fair & even in CM 1:3 complete all as specified and directed. |
| 5 | M&L Preparing of new surface of wall and applying two coats of Cement base paint over one coat of primer. |
| 6 | M & L preparation of newly plastered surfaces of wall and applying two coats of OBD over a coat of putty filling including preparation of surfaces on walls as specified and directed . |
| 7 | M & L preparation of newly plastered surfaces of ceiling and applying two coats of OBD over a coat of putty filling including preparation of surfaces on walls as specified and directed . |
| 8 | Dismantling/removing old damaged worn out APP of any thickness incl screed bed or plastering of any thickness and removing the rubish materials outside MOD land at a dumping place earmarked marked by any state govt/municipalities etc any distance complete all as specified and as directed. |
| 9 | Cleaning the surface and made free of dirt, foreign particles, laitance followed by grinding all protrusions to make surface modulated. Thereafter, inspection for cracks on the surface caused by thermal expantion contraction. Cutting the grooves with suitable cutter machine in \\"v\\" groove filled with Repair mortar/Microconcrete/General purpose grout as recommended proportionaly as per recommendation of manufacturer.Making of Gollas at all the corners with Polymer modified mortar(1:4 Cement:sand with 3.5% Acylic of cement weigth) and \\"Supplying and applying High build elastomeric waterproofing coating based on pure, hydrophobic polyurethane, cold applied of spray / brush applied, membrane with an elongation of 280% and tensile strength of 2.7 N/mm2 as per ASTM D 2370, crack bridging ability of 3mm, no leakage upto 5 bars of water pressure as per DIN 1048, min 88 % solid content. The system includes final base preparation, epoxy primer 1:1(Resin:hardner) application with 100 % water dilution and Pure polyurethane application in 2 coats with a total min consumption of 1.25 Kg per SQM .Application should be done with Graco sprayer by a company authorised applicator. \\" |
| 10 | 15mm thick rendering in cement mortar 1:4 on concrete/brick surfaces(when concrete is green) and rendering is to be even and fair with water proofing compound as per manufacturers instructions complete all as specified and directed by Engineer-in-Charge. |
| 11 | Mild steel framed work conforming to Fe-290 Gde E-165 quality-A as in grills, gratings etc. with ends of bars shouldered and/ or rivetted or forged into spikes; framed guard bars, walkways, railing, barred iron doors including side hung gates with pintel hinges, spops, hand made sliding bolts, framed work of water tanks, door chowkats and similar works including a shop coat of red oxide primer complete all as specified |
| 12 | S & F for Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws,clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required, Thickness of sheet in 1.25 mm, etc complete all as spd and directed. |
| 13 | M & L for 100 mm thick PCC 1:2:4 type B-1 (using 12.5mm graded stone aggregate) as in sub base floor complete all as specified and directed. |
| 14 | M&L for 75mm thick cement concrete1:3:6 type C1 using 20mm graded stone aggregate as in plinth protection joint filled with bitumen sand mixer 50mm thick finished even and smooth without using extra cement. |
| 15 | Cutting hole in brick wall built in cement mortar exceeding half brick but not exceeding one brick and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 , type B-1 all as specified and directed |
| 16 | S& F for Hand rails, half round or other steel section or core for wooden hand-rail straight portion,drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wiremesh etc.) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165etc complete all as spd and directed. |
| 17 | Excavation(soft/loose soil) in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface |
| 18 | M&L Cement concrete Type B2 1:3:6 (40 mm graded aggregate) as in foundation filling and mass concrete for column post |
| 19 | M & L Mild steel work as in roof trusses including special shaped washers etc complete using ERW or induction butt welded tubes coforming to IS 1161-1979 grade st-240 etc including a shop coat of red oxide primer complete all as speciied and directed. |
| 20 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 21 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft/loose soil complete all as specified. |
| 22 | M&L for plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation, filling & mass concrete, sub base complete all as specified. |
| 23 | Removal of surplus soil to a distance not exc 50 metre and depositing where directed at a level not exc 1.5 metre above the starting point complete all as specified and directed |
| 24 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick with soft/loose soil etc complete all as specified. |
| 25 | M&L for brick work with sub class ‘B’ bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 |
| 26 | S&F IN REPAIRS punched tape concertina coil 600 mm coil dia size of any type of standards, rails etc including provision of mild steel (annealed) binding wire complete all as specified and directed & by Engineer-in-Charge. |
| 27 | Galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings withand provision of galvanised mild steel wire, staples or steel pins etc IN REPLACEMENT as directed complete all as specified. |
| 28 | S&F punched tape concertina coil 600 mm coil dia size of any type of standards, rails etc including provision of mild steel (annealed) binding wire complete all as specified and directed & by Engineer-in-Charge. |
| 29 | Galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings withand provision of galvanised mild steel wire, staples or steel pins etC as directed complete all as specified. |
| 30 | Dismantling of wrought iron of mild steel work of any description in any position not otherwise specifically provided for all as specified. |
| 31 | M&L PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in coping,apex stones , bed plates etc including necessary formwork complete all as specifed and directed. |
| 32 | Demolition of brickwork built in cement mortar including all quoins, arches, pillars etc complete all as directed by EIC. |
| 33 | Demolition of cement concrete (unreinforced) in ground floors and pavings not excceding 15cm thickness (above or below ground level) all as specified. |
| 34 | M & L for 75 mm thick, Cement concrete type D-2, 1:4:8 (40mm graded aggregate), etc completed all as specified. |
| 35 | Providing and laying 60 mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved , design & pattern as in footpath , parks , lawns,drive ways or light traffic parking etc. of required strength , thickness & size/shape, made by table vibratory method using PU mould , laid in required colour & pattern over and including 25 mm thick compacted bed of fine sand , compacting and proper embedding/laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator,filling joints with sand andcutting of paver block as per required size and pattern,finishing and sweeping extra sand. |
| 36 | Cement concrete (1:2:4) type B-0 using 12.5mm graded stone aggregate as in coping including necessary formwork complete all as specified. |
| 37 | Supply and lay XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 4 core 25 sq mm |
| 38 | Excavation in trenches in hard/dense soil not exc. 1.5 metre wide and n'exc. 1.50m deep for laying cables/pipes/poles and getting out complete all as specified and directed. |
| 39 | Returning filling including spreading leveling watering and well ramming in layers not exc 25Cm in soft/ loose soil, complete all as specified and directed. |
| 40 | Removing excavated material in hard/dense soil n'exc 50M and depositing where directed at a level n'exc1.5M above the starting point, complete all as specified and directed. |
| 41 | M&L for filling approved fine crusted sand in trenches as cable cushion to the full width of excavated trench , under and over cable complete all as specified and as directed.(Note : Punned thickness of sand shall be measured) |
| 42 | Supply and lay well burnt brick class B of size 250 x 110 x 75 mm as protection to cable in cable trenches all as specified and directed |
| 43 | Taking down old u/s LT UG cable of size 10 sq mm 2 core complete all as specified and directed. |
| 44 | Supply laying and jointing GI pipe 'light grade' 40 mm bore in trenches/under floors or roads/ along poles/ on wall incl clamps for protection of cables incl fittings complete all as specified and directed. |
| 45 | Supply and fixing TPN DB's 4 way vertical type 415 V, double door suitable for housing of 100 Amps MCCB as main incoming. (Note) : 1. The cutting chases shall be finished with cement mortar (1:4) and surface shall be matched with existing surface by using putty, POP etc and applying finishing coat of existing treatment without any extra cost. |
| 46 | Supply and fixing MCCB 100 Amps, 4 Pole, 16 KA, fixed type, suitable to be fixed in 4 way TPN DB complete all as specified and directed |
| 47 | Suply and fixing 240 V, 10 KA, 'B' curve miniature circuit breaker (MCB) of single pole and current carrying capacity SP 40 Amps in the MCB DB complete with connection testing and commissioning. |
| 48 | M&L for earthing to switch gear/MCB DB with mild steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) connected to galvanised earth lead wire 4.0 mm dia by means of galvanised iron nuts, bolts and washer, earth lead connected to eqpt as directed, earth plate surrounded with adequate quantity of charcoal dust mixed with common salt to a packed thickness of 15 cm all around the plate including necessary earth work, PCC chamber and reinforced PCC cover made by PCC 1:3:6 type C-1 as in pit chamber and RCC pit cover 50 mm thick precast RCC 1:2:4 type B-1 duly reinforced with 6mm dia MS bar at 150mm c/c both ways with 10 mm dia MS round bar as handle, 20 mm bore GI pipe medium grade for watering and 15 mm dia GI pipe light grade for protection of earth lead up to 7.5 mtr with funnel, wire mesh etc with and including testing complete all as specified and as shown in electrical plate No 3 of MES sch Part I. (for TPN DB's) |
| 49 | S & F sub main wiring for circuit of size 6 sq mm 2 core (FRLS) alongwith earth wire of 6 sq mm single core of FRLS PVC insulated unsheathed cable, 1100 volts grade with multistranded copper conductor including PVC conduit of suitable size complete all as specified and directed by Engr-in-Charge. (FOR SPN DB's) |
| 50 | S & F in repair MCB DB double door SPN 8 Way with 200 Amps rated copper bus bar (Note) : 1. The cutting chases shall be finished with cement mortar (1:4) and surface shall be matched with existing surface by using putty, POP etc and applying finishing coat of existing treatment without any extra cost. |
| 51 | S & F MCB SP 6-32 Amps, 10 KA, 'C' Series |
| 52 | S & F MCB SPN 40 Amps, 10 KA, 'C' Series |
| 53 | Taking down old point wiring complete for light/fan/socket(5/15 Amps) bell point etc complete with all light fittings accessories, such as switch sockets 5/15 Amps ceiling rose etc including making good to the disturbed surface to match with the existing complete all as specified and directed by Engineer-in-Charge. |
| 54 | M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for the following :- |
| 55 | One light point control by one switch |
| 56 | One 3 pin socket outlet, 5 Amps independent |
| 57 | One 3 pin 5 amps socket outlet on the same board with other switches |
| 58 | ditto as per item No. 55 above but wire 4.0 sq mm cable for switch socket outlet 3 pin 15 Amps with 4.0 sq mm as earth continuity conductor. |
| 59 | S&F in replacement socket outlet 6A-2/3 Pin combined 2 module modular type complete all as specified and directed. |
| 60 | S&F in replacement socket outlet 6A/16A-2/3 pin combined 2 module modular type complete all as specified and directed. |
| 61 | S&F in replacement switch 6 amps modular type one one way complete all as directed. |
| 62 | S&F in replacement switch 16 amps modular type one one way complete all as directed. |
| 63 | Supply and fix ceiling rose three terminal |
| 64 | Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp |
| 65 | Supply and fixing LED tube light fitting box type with high output diffuser 4 feet, 25 watts 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete. Make : Havells/Philips/Crompton/Wipro |
| 66 | Supply and fixing in repair lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings complete all as specified and directed. |
| 67 | Supply in repair 12 watts, 6500 K, emergency bulb with high quality BIS approved Li-ion battery with 2600AH capacity, the bulb shall work as regular lamp with AC supply and emergency lamp with DC supply, the power backup in emergency mode is upto 4 hours and charging time shall be 8 hours, the deiver designed with wide voltage range of 150-300V AC complete all as specified and directed. Cat No. NE1201 of Make : Wipro or its equivalent in Philips/ Havells |
| 68 | Supply and fixing in repair LED security light fitting 90 watts 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including suitable size of GI bracket for mounting of security light to be bend as required shape, pipe bracket shall be made as per direction and site requirement and suitable size 02 Nos MS clamps and nuts and bolts. Make : Havells/Philips/Wirpo Please Enable Macros to View BoQ information |