| 1 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc., separation of serviceable materials from the unserviceable, stacking the serviceable materials within 100 M and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100 M as directed by the Engineer in Charge. |
| 2 | M&L PCC 1:4:8 type D2 using 40mm graded stone agg as in filling and mass concrete, Sub base/flooring complete all as specified and directed. |
| 3 | M&L for Brick work with fly ash bricks laid dry straight or curved on plan exc 6 m mean radius complete all as specified and as directed. |
| 4 | M & L for brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar (1:6) but except bricks (Brick shall be obtained from demolition. Unit rate for cleaning of old bricks shall be included in this item) complete all as specified and directed |
| 5 | M&L for walling of random rub-ble, brought up to courses, well bonded, bedded and solidly hearted, built in CM 1:6 complete all as specified and directed |
| 6 | ditto- as above item No. 5 but except stone and complete all as specified and directed. |
| 7 | Raised pointing to RR masonry in CM 1:4 complete all as specified and directed |
| 8 | M/L for rendering 15mm thick in CM 1:4 on fair faces of bricks or concrete surfaces finished fair and even all as specified. |
| 9 | Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness, (Below or above ground level) and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100 M as directed by the Engineer in Charge. |
| 10 | M & L for cement concrete type C2 (1:3:6) (using 40 mm graded stone aggregate) in surface channels, drains and manhole foundation etc.complete all as specified and directed |
| 11 | M&L for PCC 1:2:4 type B1 (using 20mm graded aggregate) in copings, kerbs, channels, water, soucer drain through and the like including weathering, slightly rounded or chamfered angles and throating as directed chamfered necessary for work complete all as specified and directed |
| 12 | M&L, for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc complete all as specified and directed. |
| 13 | M & L 75 mm thick plain cement concrete 1:3:6, type B-2 (using 40mm graded stone aggregate) as in plinth protection etc, finishing cement concrete surface even and smooth with out using extra cement complete as specified and directed. |
| 14 | M&L for 75 mm thick cement concrete type C2, 1:3:6 (40 mm graded aggregate) as in floor/hardstanding finished even and smooth without using extra cement and complete all as specified and directed. |
| 15 | M&L 60 mm thick machine pressed precast concrete interlocking paver block any shape & size confirming to IS 15658-2006 of 60mm thickness, M-35 grade with grey cement & pigment complete all as specified and directed. |
| 16 | M&L 80 mm thick machine pressed precast concrete interlocking paver block any shape & size confirming to IS 15658-2006 of 60mm thickness, M-35 grade with grey cement & pigment complete all as specified and directed. |
| 17 | M&L 25 mm thick sand cushioning to under concrete interlocking paver block including watering & consolidation complete all as specified |
| 18 | M&L in repair for stone sett flooring with stone settts of size 200 to 250mm long, 150 to 200 mm wide and 150mm deep and sides dressed, bedded in cement mortar 1:3, Joints 20mm thick, grouted in cement mortar 1;2 with an admixture of metallic floor hardner 5% by weight of cement and struck flush complete all as specified and directed. |
| 19 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises and complete all as specified and as directed. |
| 20 | M&L 25mm thk PCC 1:2:4 type B-0 using 12.5 mm graded agg as in flooring finished fair and even without using extra cement complete all as specified and as directed. |
| 21 | M&L, screed bed or bedding layer of mortar 15 mm thick in cement mortar 1: 6 to receive tiles etc finished rough complete all as specified and directed. |
| 22 | M&L for light/dark shed Glazed ceramic tiles 7-8 mm thick (square/ rectangular), area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm,polished, in floors etc.jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 23 | Material & Labour glazed ceramic coloured tiles 1200x600x7-8 mm thick on skiriting/dado, set & jointed in neat cement slurry & pointed with white/coloured to match over 10mm thick bedding layer of mortar to wall in cm (1:4) for laying tiles on skirting/dadocomplete all as specified and as directed. |
| 24 | M&L for Vitrified ceramic tiles 7-8mm thick (square/rectangular) polished area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match to floor etc complete all as specified and directed. |
| 25 | M&L non skid ceramic colour tiles 400x400mm, 7 to 8 mm thick (square/rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm set and jointed in neat cement slurry and pointed in colour cement to match as in floor complete all as specified and as directed |
| 26 | Supply only rough dressed Stone slab of any size for cover on manhole,drain etc complete all as specified and directed. |
| 27 | Material and labour for colour printed glazed ceramic tiles (300x 450mm, 6 to 7mm thick as in wall,dado/skirtings set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick cement plaster in cement mortar (1:4) complete all as specified and as directed by the Engr-in-Charge. |
| 28 | Dismantling of asbestos/ CGI cement (corrugated, semi-corrugated) etc sheets in roof covering including ridges etc complete all as directed. |
| 29 | S & F for pre-painted galvalume aluminum zinc coating GI based double ribbed trapezoidal profile steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 30 | Dismantling of timber scantling 40 sqcm and over for framed work and over in section, in any position |
| 31 | S&F Roof trusses (Framed), trussed, purlin, crane gantries, rails and fastenings and heavy brackets framing (Beam, tee, angle Channel or flat sections) including distance pieces cleats etc of Fe-410-W (Gde -E-250) Quality B complete. |
| 32 | Dismantling cast iron work / structural steel work of any description and in any position including doors, gates etc. complete all as specified and directed. |
| 33 | S&F mild steel framed work such as grills, gratings, etc with ends of bars shouldered and or riveted or forged into spikes, framed, barred iron door, ladders, fencing work ect. conforming to Fe-290 Gde E-165 complete all as specified and directed. |