| 1 | Taking down cement or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. |
| 2 | M&L for rendering 15 mm thick on surface other than fair face of brick work or concrete surfaces or stone masonry work in cement mortar 1:4, finished even and smooth without using extra cement complete all as specified and as directed by Enge-in-Charge |
| 3 | M&L Rendering 5mm thick on fair faces of brick work or concrete surfaces in CM (1:3) in ceiling complete all as specified and as directed by Enge-in-Charge. |
| 4 | M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces or stone masonry work in cement mortar 1:6, finished even and smooth without using extra cement complete all as specified and as directed by Enge-in-Charge. |
| 5 | M&L for preparation of new plastered surfaces and applying two coats of oil bound distemper over a coat of primer on walls/ceiling including a coat of cement based wall care putty complete all as specified and as directed by Enge-in-Charge. |
| 6 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed |
| 7 | M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete. |
| 8 | Removal of existing roof treatment consisting of screed bed, tar felts of any description etc, and removal of debris out side MD land complete including edges of slab all as directed and as specified |
| 9 | M&L for screed bed or bedding layer of mortar 10 mm thick in cement mortar 1:4 including mixing only liquid water proofing compound as per manufacturers' instructions and finishing the surface fair and even.Note:- WPC will be measured & Paid separately |
| 10 | Demolition of existing lime concrete/PCC padding of any thickness and description laid over RCC roof/Chajjas etc, cleaning and washing of roof with water to remove dust etc to receive waterproofing treatment including removal of debris out side MD land complete. |
| 11 | M&L for PCC in roof pading, filling and mass concrete type B1, 1:2:4 (using 12.5 mm graded stone aggregate) complete all as specified and directed |
| 12 | M&L for repairing the edge/corner of Chaja/roof projection and similar work by removing plaster width/girth exc 200mm but not exc 300mm and making good with 10mm thick rendering in cement mortar 1:3 to match with existing surface complete all as specified |
| 13 | Supply only liquid water proofing compound |
| 14 | Material and labour for water proofing treatment by applying one coat of oil base bituminous primer @ 0.3 Kg / Sqm with brush / roller, laying of 3 mm thick APP based polymer modified membrane (mineral finish) reinforced non-woven polyester, weight not less than 3.50 Kg / Sqm and sealing all the over laps 150 mm in length side and 100 mm in width side of membranes laid with torch application complete all as specified and as directed. |
| 15 | Refixing old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) of 15 or 20mm bore including taking town existing tubing complete all as specified and as directed by Engr-in-Charge. |
| 16 | Disconnecting existing 500 lit tanks capacity, setting aside (or lowering if required) for repairs, cleaning,including all fitting such as connection pieces with Gl tank nipple for inlet, outlet, washout and overflow etc and including 20 mm size Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipeetc. and hositing if required reconnecting and re-fixing in position. (cleaning repairing,etc. measured seperately) |
| 17 | Disconnecting existing 1000 lit tanks capacity, setting aside (or lowering if required) for repairs,cleaning,including all fitting such as connection pieces with Gl tank nipple for inlet, outlet, washout and overflow etc and including 20 mm size Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipeetc. and hositing if required reconnecting and re-fixing in position. (cleaning repairing,etc.measured seperately) |
| 18 | Cleaning and removing of 1000 lit capacity of tank all scale and from mouths of circulating pipes, etc. |
| 19 | Cleaning and removing of 500 lit capacity of tank all scale and from mouths of circulating pipes, etc. |
| 20 | Supply and fix in repair 500 liters capacity white colour triplellayer, rotational moulded, polythene water storage tank (Cylindrical vertical with closed top) hoisted and fixed on roof in position, including all fitting such as connection pieces with Gl tank nipple for inlet, outlet, washout and overflow etc and including 20 mm size Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe complete. |
| 21 | Supply and fix in repair 1000 liters capacity white colour triple layer, rotational moulded, polythene water storage tank (Cylindrical vertical with closed top) hoisted and fixed on roof in position, including all fitting such as connection pieces with Gl tank nipple for inlet, outlet, washout and overflow etc and including 20 mm size Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe complete. Please Enable Macros to View BoQ information |