| 1 | Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and directed. |
| 2 | S&F Mild steel Framed work of rolled mild steel plain angle cleats and plate for securing purlins to rafter and similar small articles confirming to Fe-410-0 or Fe -250- as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete complete all as specified and directed |
| 3 | Dismantling posts or struts (wood, steel or R.C.C.) any section embedded in concrete, including taking out embedded portion and making good disturbed ground complete all as specified and directed. |
| 4 | Excavating in post holes (or similar holes) each n exc 0.5 cum in hard /dense soil, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and directed. |
| 5 | M & L PCC 1:4:8 type D2 (using 40mm graded aggregate) in foundation for post holes complete all as specified and directed. |
| 6 | S & F Mild steel framed work such as MS grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 7 | Dismantling fencing wire mesh, any type complete all as specified and directed. |
| 8 | Supply only MS galvanised chain link fencing any size or type Complete all as specified. |
| 9 | Fixing only chain link fencing including MS galvanised with line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed. |
| 10 | M&L for 6 to 8 mm dia TMT bars cut to length and binding with mild steel wire (Annealed) not less than 0.9 mm dia complete all as specified. |
| 11 | S&F for 10 mm dia TMT bars cut to length and binding with mild steel wire (Annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 12 | S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 10 cm but n exc 15cm long dia of neck 16 mm to 20 mm complete alll as specified and directed. |
| 13 | S & F mild steel work in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or rivetting Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in , etc., and similar work conforming to Fe-290 Gde E-165 rails braces holdfast etc complete all as specified and directed. |
| 14 | Demolition of Cement Concrete of any description in ground floor & paving n.exc. 15 cm thick(below or above ground level) complete all as specified and directed. |
| 15 | M & L 75mm thick cement concrete type D-2, 1:4:8 (using 40mm graded stone aggregate) in sub base of flooring/hard standing complete all as specified and directed. |
| 16 | M &L for providing 25 mm Thick PCC 1 : 2 : 4, type B0, as in sub base of flooring/hard standing all as specified |
| 17 | M&L for plain cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) as in coping complete all as specified and directed. |
| 18 | M&L Providing precast cement concrete louvers and jallies Type B-0 (1:2:4) in CM 1:4, 25mm thick (measured solid), including all mouldings but excluding frame complete all as specified and directed. Please Enable Macros to View BoQ information |
| 19 | M&L Providing precast cement concrete louvers and jallies Type B-0 (1:2:4) in CM 1:4, 25mm thick (measured solid), including all mouldings but excluding frame complete all as specified and directed. Please Enable Macros to View BoQ information |